SNMP falling_threshold monitoring

MIBs list

SNMP falling_threshold monitoring

The objects described here can be monitored with the IPHost Network Monitor. You can start SNMP monitoring using free 30-day trial version of IPHost right now.

OID list for falling threshold

alarm Falling Threshold
alarmFallingThreshold 1.3.6.1.2.1.16.3.1.1.8 (defined in RMON-MIB)
A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the alarmRisingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1).
mte Trigger Threshold Falling
mteTriggerThresholdFalling 1.3.6.1.2.1.88.1.2.6.1.3 (defined in DISMAN-EVENT-MIB)
A threshold value to check against if mteTriggerType is 'threshold'. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, one mteTriggerThresholdFallingEvent is triggered. That event is also triggered if the first sample after this entry becomes active is less than or equal to this threshold and mteTriggerThresholdStartup is equal to 'falling' or 'risingOrFalling'. After a falling event is generated, another such event is not triggered until the sampled value rises above this threshold and reaches mteTriggerThresholdRising.
mte Trigger Threshold Delta Falling
mteTriggerThresholdDeltaFalling 1.3.6.1.2.1.88.1.2.6.1.5 (defined in DISMAN-EVENT-MIB)
A threshold value to check against if mteTriggerType is 'threshold'. When the delta value (difference) between the current sampled value (value(n)) and the previous sampled value (value(n-1)) is less than or equal to this threshold, and the delta value calculated at the last sampling interval (i.e. value(n-1) - value(n-2)) was greater than this threshold, one mteTriggerThresholdDeltaFallingEvent is triggered. That event is also triggered if the first delta value calculated after this entry becomes active, i.e. value(2) - value(1), where value(1) is the first sample taken of that instance, is less than or equal to this threshold. After a falling event is generated, another such event is not triggered until the delta value falls below this threshold and reaches mteTriggerThresholdDeltaRising.
mte Trigger Threshold Falling Event Owner
mteTriggerThresholdFallingEventOwner 1.3.6.1.2.1.88.1.2.6.1.10 (defined in DISMAN-EVENT-MIB)
To go with mteTriggerThresholdFallingEvent, the mteOwner of an event entry from mteEventTable.
mte Trigger Threshold Falling Event
mteTriggerThresholdFallingEvent 1.3.6.1.2.1.88.1.2.6.1.11 (defined in DISMAN-EVENT-MIB)
The mteEventName of the event to invoke when mteTriggerType is 'threshold' and this trigger fires based on mteTriggerThresholdFalling. A length of 0 indicates no event.
mte Trigger Threshold Delta Falling Event Owner
mteTriggerThresholdDeltaFallingEventOwner 1.3.6.1.2.1.88.1.2.6.1.14 (defined in DISMAN-EVENT-MIB)
To go with mteTriggerThresholdDeltaFallingEvent, the mteOwner of an event entry from mteEventTable.
mte Trigger Threshold Delta Falling Event
mteTriggerThresholdDeltaFallingEvent 1.3.6.1.2.1.88.1.2.6.1.15 (defined in DISMAN-EVENT-MIB)
The mteEventName of the event to invoke when mteTriggerType is 'threshold' and this trigger fires based on mteTriggerThresholdDeltaFalling. A length of 0 indicates no event.
alarm Falling Threshold
alarmFallingThreshold 1.3.6.1.2.1.16.3.1.1.8 (defined in rfc1271)
A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the alarmRisingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1).
alarm Falling Threshold
alarmFallingThreshold 1.3.6.1.2.1.16.3.1.1.8 (defined in rfc1757)
A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the alarmRisingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1).
Compaq Me Alarm Falling Threshold
cpqMeAlarmFallingThreshold 1.3.6.1.4.1.232.10.2.2.2.1.8 (defined in CPQTHRSH)
A threshold for the sampled object identifier (cpqMeAlarmVariable). If the sample type (cpqMeAlarmSampleType) is absoluteValue(1), then the following describes the comparison. When the current sampled value is less than or equal to this threshold, and the value (cpqMeAlarmValue) at the last sampling interval was greater than this threshold, a single event will be generated. If cpqMeAlarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3), then a single event will be generated if the first sample after this entry becomes valid is less than or equal to this threshold. After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the rising threshold (cpaMeAlarmRisingThreshold). If the sample type (cpqMeAlarmSampleType) is deltaValue(2), then the following describes the comparison. When the most recently sampled value minus the previous sampled value is less than or equal to the threshold (cpqMeAlarmFallingThreshold), and the current alarm value (cpqMeAlarmValue) is greater than the threshold value (cpqMeAlarmFallingThreshold) a single event will be generated. After a falling event is generated, another such event will not be generated until the most recently sampled value minus the previous sampled value rises above this threshold (cpqMeAlarmFallingThreshold) and reaches the rising threshold (cpqMeAlarmRisingThreshold). This object may not be modified if the associated cpqMeAlarmStatus object is equal to valid(1).
Cisco 2900 Port Broadcast Falling Threshold
c2900PortBroadcastFallingThreshold 1.3.6.1.4.1.9.9.87.1.4.1.1.21 (defined in CISCO-C2900-MIB)
The broadcast falling threshold is measured in number of broadcast frames received on a port in a second. When the falling threshold is crossed and the c2900PortBroadcastStormAction was stopBroadcastForwarding(1) then broadcast forwarding will be re-enabled on the port. For the other values of c2900PortBroadcastStormAction, crossing the falling threshold has no affect.
Cisco Entity Performance Config Falling Threshold
cepConfigFallingThreshold 1.3.6.1.4.1.9.9.756.1.2.1.5 (defined in CISCO-ENTITY-PERFORMANCE-MIB)
This object contains the falling threshold value for a specific performance measurement type at a specific performance interval. The value of this object must be less than cepConfigRisingThreshold. The supported range of this object can be identified by the object 'cepConfigPerfRange'. The value of zero indicates that no comparison is being made between the cepStatsMeasurement object value and the threshold value, therefore no event action will be generated.
Cisco Entity Quantum Flow Processors Memory Resource Falling Threshold
ceqfpMemoryResFallingThreshold 1.3.6.1.4.1.9.9.715.1.1.7.1.7 (defined in CISCO-ENTITY-QFP-MIB)
This object represents the falling threshold value for this memory resource. A value of zero means that the falling threshold is not supported for this memory resource. The value of this object can not be set to higher than or equal to ceqfpMemoryResRisingThreshold. A falling (ceqfpMemoryResRisingThreshNotif) notification will be generated, whenever the memory resource usage (ceqfpMemoryResInUse) is equal to or lesser than this value. After a falling notification is generated, another such notification will not be generated until the ceqfpMemoryResInUse rises above this value and reaches the ceqfpMemoryResRisingThreshold.
Cisco Embedded Resource Manager Policy Falling Threshold
cermPolicyFallingThreshold 1.3.6.1.4.1.9.9.510.1.3.2.1.9 (defined in CISCO-ERM-MIB)
This object indicates the falling threshold value set for the threshold configuration. Lets assume that system global threshold value (in percentage) for 'io' memory resource owner is set to 10% as minor falling threshold value, 20% as major falling threshold value and 30% as critical falling threshold value. When the total 'io' memory utilization falls below 10%, a minor 'down' notification will be sent to relevant resource user(s). When the total 'io' memory utilization falls below 20%, a major 'down' notification will be sent to relevant resource user(s). When it falls below 30%, a critical 'down' notification will be sent to relevant resource user(s). The 'down' notification will be sent only if corresponding 'up' notification has already been sent to relevant resource user(s). Zero value for this object indicates that the falling threshold value is not configured.
Switch Safe Guard Falling Threshold
swSafeGuardFallingThreshold 1.3.6.1.4.1.171.12.19.2.2 (defined in SAFEGUARD-ENGINE-MIB)
The object indicates safe guard engine falling threshold in percentage. the range is between 20%-100% , if the CPU utilization is lower than the falling threshold, the switch enters normal mode.
Round Trip Time Monitor React Admin Threshold Falling
rttMonReactAdminThresholdFalling 1.3.6.1.4.1.9.9.42.1.2.6.1.4 (defined in CISCO-RTTMON-MIB)
This object defines a threshold limit. If the RTT operation time falls below this limit and if the conditions specified in rttMonReactAdminThresholdType are satisfied, an threshold is generated.
Round Trip Time Monitor React Threshold Falling
rttMonReactThresholdFalling 1.3.6.1.4.1.9.9.42.1.2.19.1.6 (defined in CISCO-RTTMON-MIB)
This object defines a lower threshold limit. If the value ( e.g rtt, jitterAvg, packetLossSD etc ) falls below this limit and if the conditions specified in rttMonReactThresholdType are satisfied, a trap is generated. Default value of rttMonReactThresholdFalling 'rtt' is 3000 'jitterAvg' is 100. 'jitterSDAvg' is 100. 'jitterDSAvg' 100. 'packetLossSD' is 10000. 'packetLossDS' is 10000. 'mos' is 500. 'icpif' is 93. 'packetMIA' is 10000. 'packetLateArrival' is 10000. 'packetOutOfSequence' is 10000. 'maxOfPositiveSD' is 10000. 'maxOfNegativeSD' is 10000. 'maxOfPositiveDS' is 10000. 'maxOfNegativeDS' is 10000. 'iaJitterDS' is 20. 'frameLossDS' is 10000. 'mosLQDS' is 310. 'mosCQDS' is 310. 'rFactorDS' is 60. 'successivePacketLoss' is 1000. 'maxOfLatencyDS' is 3000. 'maxOfLatencySD' is 3000. 'latencyDSAvg' is 3000. 'latencySDAvg' is 3000. 'packetLoss' is 10000. 'iaJitterSD' is 20. 'mosCQSD' is 310. 'rFactorSD' is 60. This object is not applicable if the rttMonReactVar is 'timeout', 'connectionLoss' or 'verifyError'. For 'timeout', 'connectionLoss' and 'verifyError' default value of rttMonReactThresholdFalling will be 0.

MIBs list