server_fail monitor - SNMP OIDs

MIBs list

OIDs - server_fail monitor

The objects described here can be monitored with the IPHost Network Monitor. You can start SNMP monitoring using free 30-day trial version of IPHost right now.

OID list for server fail

Compaq Server Health Asr Boot Fail
cpqHeAsrBootFail 1.3.6.1.4.1.232.6.2.5.16 (defined in CPQHLTH)
The action to be taken if an ASR reboot failure occurs.
trap Sntp Server Fail
trapSntpServerFail 1.3.6.1.4.1.52.4.13.5.2.20 (defined in ctron-ap3000-mib)
The administrative enable/disable state for SNMP sntpServerFail trap.
Enterasys Load Sharing Network Address Translation Real Server Fail Detect Type
etsysLsnatRealServerFailDetectType 1.3.6.1.4.1.5624.1.2.74.2.3.1.6 (defined in enterasys-lsnat-mib)
This object contains the fail detect type assigned to this Real server. - `none', indicates there is no fail detection used to verify the operational state of the Real Server. - `probe', indicates that probes are used to verify the operational state or the Real server.
Enterasys Load Sharing Network Address Translation Real Server Fail Detect Probe One
etsysLsnatRealServerFailDetectProbeOne 1.3.6.1.4.1.5624.1.2.74.2.3.1.7 (defined in enterasys-lsnat-mib)
The name of probe one assigned to the Real Server. Probes are used to verify the operational state of the Real Server. A null string indicates that probe one is not assigned.
Enterasys Load Sharing Network Address Translation Real Server Fail Detect Probe Two
etsysLsnatRealServerFailDetectProbeTwo 1.3.6.1.4.1.5624.1.2.74.2.3.1.8 (defined in enterasys-lsnat-mib)
The name of probe two assigned to the Real Server. Probes are used to verify the operational state of the Real Server. A null string indicates that probe two is not assigned.
Enterasys Twcb Cache Server Fail Detect Type
etsysTwcbCacheServerFailDetectType 1.3.6.1.4.1.5624.1.2.76.2.3.1.5 (defined in enterasys-twcb-mib-2)
This object contains the fail detect type assigned to this Cache server. - `none', indicates there is no fail detection used to verify the operational state of the Cache Server. - `probe', indicates that probes are used to verify the operational state or the Cache server.
Enterasys Twcb Cache Server Fail Detect Probe One
etsysTwcbCacheServerFailDetectProbeOne 1.3.6.1.4.1.5624.1.2.76.2.3.1.6 (defined in enterasys-twcb-mib-2)
The name of probe one assigned to the Cache Server. Probes are used to verify the operational state of the Cache Server. A null string indicates that probe one is not assigned.
Enterasys Twcb Cache Server Fail Detect Probe Two
etsysTwcbCacheServerFailDetectProbeTwo 1.3.6.1.4.1.5624.1.2.76.2.3.1.7 (defined in enterasys-twcb-mib-2)
The name of probe two assigned to the Cache Server. Probes are used to verify the operational state of the Cache Server. A null string indicates that probe two is not assigned.
Enterasys Twcb Cache Server Fail Detect Application Port
etsysTwcbCacheServerFailDetectAppPort 1.3.6.1.4.1.5624.1.2.76.2.3.1.8 (defined in enterasys-twcb-mib-2)
The service port used when an application TCP probe session is configured in etsysTwcbCacheServerFailDetectProbeOne or etsysTwcbCacheServerFailDetectProbeTwo for this Cache server.
Cisco Content Service Net Server Response Fail Alarm Threshold
ccsNetServerResponseFailAlarmThreshold 1.3.6.1.4.1.9.9.597.1.1.1.1.6 (defined in CISCO-CONTENT-SERVICES-MIB)
This object specifies the alarm threshold of the number of the failed responses specified by ccsNetServerResponseFailCountNotifInfo from the network server in the time interval (ccsAdControlAlarmUpdateTimer). When ccsAdControlNotifEnabled is set to 'true', the count is greater than the threshold, and no alarm notification specified by ciscoContentServicesNetServerResponseFailExceeded has been issued within the timer interval, the alarm notification will be generated and the timer will be re-started. The threshold should be greater than the clear threshold ccsNetServerResponseFailClearThreshold. When the threshold is changed, the counter will be reset, the alarm will be cleared, and the timer will be re-started.
Cisco Content Service Net Server Response Fail Clear Threshold
ccsNetServerResponseFailClearThreshold 1.3.6.1.4.1.9.9.597.1.1.1.1.7 (defined in CISCO-CONTENT-SERVICES-MIB)
This object specifies the clear threshold associated with ccsNetServerResponseFailAlarmThreshold. If ccsAdControlNotifEnabled is set to 'true', the count (ccsNetServerResponseFailCountNotifInfo) is equal to or lower than the threshold when the timer (ccsAlarmUpdateTimer) expires and the alarm specified by ciscoContentServicesNetServerResponseFailExceeded exists, the clear notification specified by ciscoContentServicesNetServerResponseFailAlarmCleared is generated. The threshold should be less than the alarm threshold specified by ccsNetServerResponseFailAlarmThreshold. When the threshold is changed, the counter will be reset, the alarm will be cleared if exists, and the timer will be re-started.
Cisco Content Service Net Server Response Time Fail Alarm Threshold
ccsNetServerResponseTimeFailAlarmThreshold 1.3.6.1.4.1.9.9.597.1.1.1.1.9 (defined in CISCO-CONTENT-SERVICES-MIB)
This object specifies the alarm threshold of the number of the responses specified by ccsNetServerResponseTimeFailCountNotifInfo for the first payload packet from the network server exceeds the response time ccsNetServerFirstPayloadResponseTime within the time interval (ccsAdControlAlarmUpdateTimer). When ccsAdControlNotifEnabled is set to 'true', the count is greater than the threshold and no alarm notification specified by ciscoContentServicesNetServerResponseTimeExceeded has been issued, the alarm notification will be generated and the timer will be re-started. The threshold should be greater than the clear threshold ccsNetServerResponseTimeFailClearThreshold. When the threshold is changed, the counter will be reset, the alarm will be cleared if exists, and the timer will be re-started.
Cisco Content Service Net Server Response Time Fail Clear Threshold
ccsNetServerResponseTimeFailClearThreshold 1.3.6.1.4.1.9.9.597.1.1.1.1.10 (defined in CISCO-CONTENT-SERVICES-MIB)
This object specifies the clear threshold associated with ccsNetServerResponseTimeFailAlarmThreshold. If ccsAdControlNotifEnabled is set to 'true', the count (ccsNetServerResponseTimeFailCountNotifInfo) is equal to or lower than the threshold when the timer (ccsAdControlAlarmUpdateTimer) expires and the alarm specified by ciscoContentServicesNetServerResponseTimeExceeded exists, the clear notification specified by ciscoContentServicesNetServerResponseTimeAlarmCleared is generated. The threshold should be less than the alarm threshold specified by ccsNetServerResponseTimeFailAlarmThreshold. When the threshold is changed, the counter will be reset, the alarm will be cleared, and the timer will be re-started.
Cisco Content Service Net Server Response Fail Count Notification Info
ccsNetServerResponseFailCountNotifInfo 1.3.6.1.4.1.9.9.597.1.4.11 (defined in CISCO-CONTENT-SERVICES-MIB)
This object specifies the number of the failed response from the network server.
Cisco Content Service Net Server Response Time Fail Count Notification Info
ccsNetServerResponseTimeFailCountNotifInfo 1.3.6.1.4.1.9.9.597.1.4.12 (defined in CISCO-CONTENT-SERVICES-MIB)
This object specifies the number of the response for the first payload packet from the network server exceeds the response time specified by ccsNetServerFirstPayloadResponseTime.
Cisco Dns Ha Response Server Fail counts
cDnsHaResponseServFailCnts 1.3.6.1.4.1.9.9.405.1.12.21 (defined in CISCO-DNS-SERVER-MIB)
Total number of HA responses reporting a server failure error.
Cisco Dns Ha Interval Response Server Fail counts
cDnsHaIntResponseServFailCnts 1.3.6.1.4.1.9.9.405.1.13.21 (defined in CISCO-DNS-SERVER-MIB)
Number of HA responses reporting a server failure error during reporting interval.

MIBs list