drive_time monitor - SNMP OIDs

MIBs list

OIDs - drive_time

The objects described here can be monitored with the IPHost Network Monitor. You can start SNMP monitoring using free 30-day trial version of IPHost right now.

OID list for drive time

Compaq Fibre Array Fibre Channel Array Log Drive Blink Time
cpqFcaLogDrvBlinkTime 1.3.6.1.4.1.232.16.2.3.1.1.14 (defined in CPQFCA)
External Array Logical Drive Physical Drive Blink Time Count. The logical drive blink time variable allows the drive tray LEDs of all physical drives in a logical drive to blink. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs will continue to blink. A value of zero indicates the drive LEDs are not blinking. If the value cannot be determined or no drive in this logical drive is in a hot plug tray, 4,294,967,295 is returned. To blink the drive LEDs on all physical drives in this logical drive (including any configured spare drives), set this value to the time to blink in tenths of seconds. To stop the drive LEDs from blinking, set this value to 0.
Compaq Fibre Array Fibre Channel Array Physical Drive Spin up Time
cpqFcaPhyDrvSpinupTime 1.3.6.1.4.1.232.16.2.5.1.1.21 (defined in CPQFCA)
Spin up Time in tenths of seconds. This is the time it takes for a physical drive to spin up to full speed. Disks require time to gain momentum and reach operating speed. As cars are tested to go from 0 mph to 60 mph in x number of seconds, drive manufacturers have preset expectations for the time it takes the drive to spin to full speed. Drives that do not meet these expectations may have problems. The value may be zero (0) under one of the following conditions: * If you are monitoring a physical drive that is part of the monitored system's internal drive array storage, and you use a warm boot to reset the monitored system. During a warm boot, the drives continue to spin. * If you have a Compaq Drive Array but have a version of the physical controller ROM that is less than version 1.00. If you have used an upgrade utility on versions less than 1.00, the value may still be zero. * If you are monitoring a physical drive in an Intelligent Array Expansion System and you reset the monitored system but not the Intelligent Array Expansion System. If you suspect a problem, schedule server down time to run Compaq Diagnostics and select the Drive Monitoring Diagnostics option to verify that a problem exists. If the value cannot be determined, -1 is returned.
Compaq Fibre Array Fibre Channel Array Physical Drive Blink Time
cpqFcaPhyDrvBlinkTime 1.3.6.1.4.1.232.16.2.5.1.1.48 (defined in CPQFCA)
Physical Drive LED Blink Time. This value is the amount of time remaining for the drive LEDs to blink in tenths of seconds. A value of zero means the drive LEDs are not blinking. If the value cannot be determined or the drive is not in a hot plug tray, 4,294,967,295 is returned. To blink the drive LEDs, set this value to the time to blink in tenths of seconds. To stop the drive LEDs from blinking, set this value to 0.
Compaq Fibre Array Fibre Channel Array Physical Drive Threshold Spin up Time
cpqFcaPhyDrvThrSpinupTime 1.3.6.1.4.1.232.16.2.6.1.1.4 (defined in CPQFCA)
Spin up Time Maximum Threshold in tenths of seconds. This shows the maximum of time it takes for a physical drive to spin up to full speed. This threshold is associated with the cpqFcaPhyDrvSpinupTime object in the Physical Drive Table. If the value cannot be determined, -1 is returned.
Compaq Fibre Array Fibre Channel Array Physical Drive Threshold Violation Spin up Time
cpqFcaPhyDrvThrViSpinupTime 1.3.6.1.4.1.232.16.2.6.1.1.9 (defined in CPQFCA)
Spin up Time in tenths of seconds Threshold Has Been Violated. This is used to indicate whether the time it took for a physical drive to spin up to full speed has ever exceeded the maximum allowable threshold. The valid values are: false (1) Indicates that the Spin up Time object (cpqFcaPhyDrvSpinupTime) value has not exceeded the maximum threshold (cpqFcaPhyDrvThrSpinupTime). true (2) Indicates that the Spin up Time object (cpqFcaPhyDrvSpinupTime) value has exceeded the maximum threshold (cpqFcaPhyDrvThrSpinupTime). unknown (3) The agent is unable to determine if the drive has a threshold violation.
Compaq Drive Array Nw3x Poll Time
cpqDaNw3xPollTime 1.3.6.1.4.1.232.3.2.1.1.4 (defined in CPQIDA)
Compaq Array Controller Driver Interface Poll Time. If the Poll Type is Polled, this value shows how frequently, in seconds, the instrument agent requests Information from the device driver. For example, if the Poll Type is Polled and the Poll Time is two, the instrument agent will poll the device driver every two seconds. To change the Poll Time for NetWare, unload and then reload the instrument agent using the following commands: UNLOAD CPQDSKSA LOAD CPQDSKSA [/Un] The parameter /U specifies the frequency of updates in seconds. The variable n represents the number of seconds that the NLM should wait before collecting new data. The minimum value is one second. The maximum value is 300 seconds (five minutes).
Compaq Drive Array Controller Blink Time
cpqDaCntlrBlinkTime 1.3.6.1.4.1.232.3.2.2.1.1.22 (defined in CPQIDA)
Controller Physical Drive Blink Time Count. The controller blink time variable allows the drive tray LEDs of all physical drives attached to this controller to blink. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs will continue to blink. A value of zero indicates the drive LEDs are not blinking. If the value cannot be determined or no drive on this controller is in a hot plug tray, 4,294,967,295 is returned. To blink the drive LEDs on all physical drives attached to this controller, set this value to the time to blink in tenths of seconds. To stop the drive LEDs from blinking, set this value to 0.
Compaq Drive Array Log Drive Blink Time
cpqDaLogDrvBlinkTime 1.3.6.1.4.1.232.3.2.3.1.1.15 (defined in CPQIDA)
Logical Drive Physical Drive Blink Time Count. The logical drive blink time variable allows the drive tray LEDs of all physical drives in a logical drive to blink. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs will continue to blink. A value of zero indicates the drive LEDs are not blinking. If the value cannot be determined or no drive in this logical drive is in a hot plug tray, 4,294,967,295 is returned. To blink the drive LEDs on all physical drives in this logical drive (including any configured spare drives), set this value to the time to blink in tenths of seconds. To stop the drive LEDs from blinking, set this value to 0.
Compaq Drive Array Physical Drive Spin up Time
cpqDaPhyDrvSpinupTime 1.3.6.1.4.1.232.3.2.5.1.1.22 (defined in CPQIDA)
Spin up Time in tenths of seconds. This is the time it takes for a physical drive to spin up to full speed. Disks require time to gain momentum and reach operating speed. As cars are tested to go from 0 mph to 60 mph in x number of seconds, drive manufacturers have preset expectations for the time it takes the drive to spin to full speed. Drives that do not meet these expectations may have problems. The value may be zero (0) under one of the following conditions: * If you are monitoring a physical drive that is part of the monitored system's internal drive array storage, and you use a warm boot to reset the monitored system. During a warm boot, the drives continue to spin. * If you have a Compaq Drive Array but have a version of the physical controller ROM that is less than version 1.00. If you have used an upgrade utility on versions less than 1.00, the value may still be zero. * If you are monitoring a physical drive in an Intelligent Array Expansion System and you reset the monitored system but not the Intelligent Array Expansion System. If you suspect a problem, schedule server down time to run Compaq Diagnostics and select the Drive Monitoring Diagnostics option to verify that a problem exists.
Compaq Drive Array Physical Drive Blink Time
cpqDaPhyDrvBlinkTime 1.3.6.1.4.1.232.3.2.5.1.1.56 (defined in CPQIDA)
Physical Drive Blink Time Count. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs will continue to blink. A value of zero indicates the drive LEDs are not blinking. If the value cannot be determined or the drive is not in a hot plug tray, 4,294,967,295 is returned. To blink the drive LEDs, set this value to the time to blink in tenths of seconds. To stop the drive LEDs from blinking, set this value to 0.
Compaq Drive Array Physical Drive Time
cpqDaPhyDrvTime 1.3.6.1.4.1.232.3.2.5.2.1.13 (defined in CPQIDA)
Physical Drive Error Log Reference Time. This gives a relative time stamp as to when the error log entry occurred. The Reference Time shows the number of hours that a physical drive has been spinning since the drive was initialized for monitor and performance.
Compaq Drive Array Physical Drive Threshold Spin up Time
cpqDaPhyDrvThrSpinupTime 1.3.6.1.4.1.232.3.2.6.1.1.11 (defined in CPQIDA)
Spin up Time Maximum Threshold in tenths of seconds. This shows the maximum of time it takes for a physical drive to spin up to full speed. This threshold is associated with the cpqDaPhyDrvSpinupTime object in the Physical Drive Table.
Compaq Drive Array Physical Drive Threshold Violation Spin up Time
cpqDaPhyDrvThrViSpinupTime 1.3.6.1.4.1.232.3.2.6.1.1.31 (defined in CPQIDA)
Spin up Time in tenths of seconds Threshold Has Been Violated. This is used to indicate whether the time it took for a physical drive to spin up to full speed has ever exceeded the maximum allowable threshold. The valid values are: false (1) Indicates that the Spin up Time object (cpqDaPhyDrvSpinupTime) value has not exceeded the maximum threshold (cpqDaPhyDrvThrSpinupTime). true (2) Indicates that the Spin up Time object (cpqDaPhyDrvSpinupTime) value has exceeded the maximum threshold (cpqDaPhyDrvThrSpinupTime). unknown (4294967295) The agent is unable to determine if the drive has a threshold violation.
Compaq Drive Array Trap Time
cpqDaTrapTime 1.3.6.1.4.1.232.3.3.3.1.3 (defined in CPQIDA)
The time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Each octet gives the value in BCD.
Compaq Scsi Physical Drive Spin up Time
cpqScsiPhyDrvSpinupTime 1.3.6.1.4.1.232.5.2.4.1.1.21 (defined in CPQSCSI)
Compaq SCSI Physical Drive Spin up Time (tenths of seconds). This is the time it takes for a physical drive to spin up to full speed. Disks require time to gain momentum and reach operating speed. As cars are tested to go from 0 mph to 60 mph in x number of seconds, drive manufacturers have preset expectations for the time it takes the drive to spin to full speed. Drives that do not meet these expectations may have problems. If the drive is having problems spinning up, this value will increase over time. Eventually, the drive may fail to spin up altogether. If you see a large increase in this value over time, you may want to replace the drive as a precaution.

MIBs list