OID list for battery status

ups Battery Status
upsBatteryStatus 1.3.6.1.2.1.33.1.2.1 (defined in rfc1628)
The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
Compaq Fibre Array Fibre Channel Array Accelerator Battery Status
cpqFcaAccelBatteryStatus 1.3.6.1.4.1.232.16.2.2.2.1.6 (defined in CPQFCA)
Array Accelerator Board Battery Status. This monitors the status of each battery pack on the board. The batteries can only recharge when the system has power applied. The following values are valid: Other (1) Indicates that the instrument agent does not recognize battery status. You may need to update your software. Ok (2) Indicates that a particular battery pack is fully charged. Charging (3) The battery power is less than 75%. The array controller is attempting to recharge the battery. A battery can take as long as 36 hours to fully recharge. After 36 hours, if the battery has not recharged, it is considered failed. Failed (4) The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Your Array Accelerator board needs to be serviced. Degraded (5) The battery is still operating, however, one of the batteries in the pack has failed to recharge properly. Your Array Accelerator board should be serviced as soon as possible. NotPresent (6) There are no batteries associated with this controller.
Compaq Specific PC Server Sys Battery Status
cpqSiSysBatteryStatus 1.3.6.1.4.1.232.2.2.10.2.1.9 (defined in CPQSINFO)
This provides the current status of the battery. The following status values are supported: other(1): This battery does not support status reporting. ok(2): The battery is operating ok. User Action: No action required. capacityDegraded(3): Significant battery degradation has occurred. The battery can no longer be fully recharged. User Action: If using multiple batteries, run Compaq Power Conservation Utility to identify the battery location. Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery. chargeFault(4): One or more batteries are not functioning properly. User Action: Make sure all batteries are operating in the recommended temperature range. Check for foreign objects in the battery slots. Remove and reinsert all batteries to resume normal battery operation. Contact your System Administrator or Compaq Authorized Reseller if you are still experiencing problems. batteryFailure(5): The battery has failed and must be replaced. User Action: Contact your System Administrator or Compaq Authorized Reseller to order a replacement battery. Recycle your old battery. For proper disposal information, refer to the documentation that came with your computer.
Compaq Sm2 Controller Battery Status
cpqSm2CntlrBatteryStatus 1.3.6.1.4.1.232.9.2.2.5 (defined in CPQSM2)
Remote Insight Battery Status. The following values are defined: other(1) The Insight Agent is unable to determine if the battery needs replacement. batteryOk(2) The Remote Insight battery is OK. batteryFailed(3) The Remote Insight battery needs replacement. batteryDisconnected(4) The Remote Insight battery is disconnected.
bsn Tag Battery Status
bsnTagBatteryStatus 1.3.6.1.4.1.14179.2.1.18.1.4 (defined in AIRESPACE-WIRELESS-MIB)
Battery Status of the RF ID Tag.