cpqDaPhyDrvSeekErrs - Compaq Drive Array Physical Drive Seek Errors - CPQIDA

MIBs list

cpqDaPhyDrvSeekErrs

Compaq Drive Array Physical Drive Seek Errors
1.3.6.1.4.1.232.3.2.5.1.1.21

Seek Errors (low). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk drive detected a seek error during the reference hours (phyDrvRefHours). The actual number of seek errors equals the phyDrvHSeekErrs times 2^32 plus the phyDrvWriteSeekErrs. Over time, a disk drive usually produces these errors. If you notice a rapid increase in the value shown for Seek Errors, this physical drive may be failing. The value increases every time the physical drive produces another error. Only an unusually rapid increase in these errors indicates a problem. If you suspect that a problem exists, schedule server down time to run Compaq Diagnostics.

Back to CPQIDA MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqDaPhyDrvSeekErrs with IPHost tools

MIBs list