cpqDaPhyDrvNotReadyErrs - Compaq Drive Array Physical Drive Not Ready Errors - CPQIDA

MIBs list

cpqDaPhyDrvNotReadyErrs

Compaq Drive Array Physical Drive Not Ready Errors
1.3.6.1.4.1.232.3.2.5.1.1.33

Drive Not Ready Errors. The number of times the physical drive failed after the spin up command was issued during the reference time (phyDrvRefTime). When the spin up command was issued, the drive failed to reach its ready state. If the current value is zero, the drive has not failed. If the current value is greater than zero, at least one failure occurred. This error could be caused because the physical drive has failed to spin. If you suspect a problem: 1. Check the cables connecting the drive to ensure that they are intact. 2. If the cables are properly connected, schedule server down time to run Compaq Diagnostics to verify that a problem exists.

Back to CPQIDA MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqDaPhyDrvNotReadyErrs with IPHost tools

MIBs list