cpqDaPhyDrvDrqTimeouts - Compaq Drive Array Physical Drive Drq Timeouts - CPQIDA

MIBs list

cpqDaPhyDrvDrqTimeouts

Compaq Drive Array Physical Drive Drq Timeouts
1.3.6.1.4.1.232.3.2.5.1.1.26

DRQ Timeouts. The number of times that a physical drive continued to request data, but did not get a command completion during the reference time (phyDrvRefTime). This value increases every time a DRQ timeout occurs for the physical drive. A defective drive or cable may cause DRQ timeouts to occur. If you see an increase in these errors, complete the following steps for the monitored system: 1. Check the cables connecting the drive to ensure that they are intact. 2. If the cables are properly connected, schedule server down time to run Compaq Diagnostics to verify that a problem exists.

Back to CPQIDA MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqDaPhyDrvDrqTimeouts with IPHost tools

MIBs list