cpqDaCntlrModel - Compaq Drive Array Controller Model - CPQIDA

MIBs list

cpqDaCntlrModel

Compaq Drive Array Controller Model
1.3.6.1.4.1.232.3.2.2.1.1.2

Compaq Array Controller Model. The type of controller card. The valid types are: Other (1) You may need to upgrade your driver software and\or instrument agent(s). You have a drive array controller in the system that the instrument agent does not recognize. IDA (2) Compaq 32-Bit Intelligent Drive Array Controller. The physical drives are located inside the system. IDA Expansion (3) Compaq 32-Bit Intelligent Drive Array Expansion Controller. The physical drives are located in the Array Expansion System that is connected to the system by a cable. IDA - 2 (4) Compaq Intelligent Drive Array Controller-2 (IDA-2). The physical drives are located inside the system. SMART (5) Compaq SMART Array Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. SMART - 2/E (6) Compaq SMART-2/E Array Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. SMART - 2/P (7) Compaq SMART-2/P Array Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. SMART - 2SL (8) Compaq SMART-2SL Array Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. Smart - 3100ES (9) Compaq Smart Array 3100ES Controller. The physical drives are located inside the system. Smart - 3200 (10) Compaq Smart Array 3200 Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. SMART - 2DH (11) Compaq SMART-2DH Array Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. Smart - 221 (12) Compaq Smart Array 221 Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. Smart Array 4250ES (13) Compaq Smart Array 4250ES Controller. The physical drives are located inside the system. Smart Array 4200 (14) Compaq Smart Array 4200 Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. Integrated Smart Array (15) Compaq Integrated Smart Array Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. Smart Array 431 (16) Compaq Smart Array 431 Controller. The physical drives can be located inside the system or outside the system in a Compaq ProLiant Storage System that is connected to the system by a cable. Smart Array 5300 (17) Compaq Smart Array 5300 Controller. RAID LC2 Controller (18) Compaq RAID LC2 Controller. Smart Array 5i (19) Compaq Smart Array 5i Controller. Smart Array 532 (20) Compaq Smart Array 532 Controller. Smart Array 5312 (21) Compaq Smart Array 5312 Controller.

Back to CPQIDA MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqDaCntlrModel with IPHost tools

MIBs list