cpqFcaAccelErrCode - Compaq Fibre Array Fibre Channel Array Accelerator Error Code - CPQFCA

MIBs list

cpqFcaAccelErrCode

Compaq Fibre Array Fibre Channel Array Accelerator Error Code
1.3.6.1.4.1.232.16.2.2.2.1.5

Array Accelerator Board Error Code. Use this to determine the status of the write cache operations. The status can be: Other (1) Indicates that the instrument agent does not recognize the error code. You may need to update your software. Invalid (2) Indicates that write cache operations are currently configured and enabled for at least one logical drive. No write cache errors have occurred. Bad Configuration (3) Indicates that write cache operations are temporarily disabled. The Array Accelerator board was configured for a different controller. This error could be caused if boards were switched from one system to another. Rerun the Compaq EISA Configuration Utility and ensure that the board has been properly configured for this system. Note: If data from another system was stored on the board, rerunning EISA Configuration will cause the data to be lost. Low Battery Power (4) Indicates that write cache operations are temporarily disabled due to insufficient battery power. Please view the Battery Status object instance for more information. Disable Command Issued (5) Indicates that write cache operations are temporarily disabled. The device driver issues this command when the server is taken down. This condition should not exist when the system regains power. No Resources Available (6) Indicates that write cache operations are temporarily disabled. The controller does not have sufficient resources to perform write cache operations. For example, when a replaced drive is being rebuilt, there will not be sufficient resources. Once the operation that requires the resources has completed, this condition will clear and write cache operations will resume. Board Not Connected (7) Indicates that write cache operations are temporarily disabled. The Array Accelerator board has been configured but is not currently attached to the controller. Check the alignment of the board and connections. Bad Mirror Data (8) Indicates that write cache operations have been permanently disabled. The Array Accelerator board stores mirrored copies of all data. If data exists on the board when the system is first powered up, the board performs a data compare test between the mirrored copies. If the data does not match, an error has occurred. Data may have been lost. Your board may need servicing. Read Failure (9) Indicates that write cache operations have been permanently disabled. The Array Accelerator board stores mirror copies of all data. While reading the data from the board, memory parity errors have occurred. Both copies were corrupted and cannot be retrieved. Data has been lost, and you should service the board. Write Failure (10) Indicates that write cache operations have been permanently disabled. This error occurs when an unsuccessful attempt was made to write data to the Array Accelerator board. Data could not be written to write cache memory in duplicate due to the detection of parity errors. This error does not indicate data loss. You should service the Array Accelerator board. Config Command (11) Indicates that write cache operations have been permanently disabled. The configuration of the logical drives has changed. You need to reconfigure the Array Accelerator board. Expand In Progress (12) Indicates that cache operations are temporarily disabled due to an expand of a logical drive. When the expand operation completes, the accelerator will be enabled. Snapshot In Progress (13) Indicates that cache operations are temporarily disabled due to a snapshot operation that is queued up or in progress. When the snapshot operation completes, the accelerator will be enabled. Redundant Low Battery (14) Indicates that cache operations are temporarily disabled. The redundant controller has insufficient cache battery power. Redundant Size Mismatch (15) Indicates that cache operations are temporarily disabled. The cache sizes on the redundant controllers do not match. Redundant Cache Failure (16) Indicates that cache operations are temporarily disabled. The cache on the redundant controller has failed. Excessive ECC Errors (17) Indicates that write cache operations have been permanently disabled. The number of cache lines experiencing excessive ECC errors has reached a preset limit. Power On Self Test (Post) ECC Errors (19) Indicates that write cache operations have been permanently disabled. The cache has been disabled due to a large number of ECC errors detected while testing the cache during Power On Self Test (Post).

Back to CPQFCA MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqFcaAccelErrCode with IPHost tools

MIBs list