cpqFcaAccelBadData - Compaq Fibre Array Fibre Channel Array Accelerator Bad Data - CPQFCA

MIBs list

cpqFcaAccelBadData

Compaq Fibre Array Fibre Channel Array Accelerator Bad Data
1.3.6.1.4.1.232.16.2.2.2.1.4

Array Accelerator Board Bad Data. The following values are valid: None (2) Indicates that no data loss occurred. The battery packs were properly charged when the system was initialized. Possible (3) Indicates that at power up, the battery packs were not sufficiently charged. Because the batteries did not retain sufficient charge when the system resumed power, the board has not retained any data that may have been stored. If no data was on the board, no data was lost. Several things may have caused this condition: * If the system was without power for eight days, and the battery packs were on (battery packs only activate if system looses power unexpectedly), any data that may have been stored in the cache was lost. * There may be a problem with the battery pack. See the Battery Status for more information. * This status will also appear if the Array Accelerator board is replaced with a new board that has discharged batteries. No data has been lost in this case, and posted writes will automatically be enabled when the batteries reach full charge.

Back to CPQFCA MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).