a3ComSysPowerSupplyStatus - Sys Power Supply Status - A3COM-SWITCHING-SYSTEMS-MIB

MIBs list

a3ComSysPowerSupplyStatus

Sys Power Supply Status
1.3.6.1.4.1.43.29.4.4.2.1.2

This object represents the power supply status. The value is a sum. It initially takes on the value 0, then for each type which is active, 2 raised to a power is added to the sum. The powers are according to the following table. For the 6000 Backbone Aggregator an over temp for power supply 1 and power supply 2 will be reported as a power supply 1 Over Temperature Failure, and a fan failure will be reported as a power supply 2 Over Temperature Failure. Failure Type Power AC Failure 0 Plus 5 Failure 1 Plus 12 Failure 2 Over Temperature Failure 3 Power Supply Inserted 4 Power Supply Extracted 5

Back to A3COM-SWITCHING-SYSTEMS-MIB MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of a3ComSysPowerSupplyStatus with IPHost tools

MIBs list