-- -- "@(#)swmib.smiv1 1.20 99/01/07" -- -- Title: Fibre Channel Switch MIB, Version 1.6a -- -- Significant changes (since V1.6): -- o added Event Group -- -- This is specified based on SMIv1, mainly to ensure that the specification -- can be parsed easily by off-the-shelf network management product in -- the market. -- SW-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Counter, NetworkAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC1212; -- additional textual conventions -- DisplayString: comment out the next line if your MIB compiler complains -- that it is already defined. DisplayString ::= OCTET STRING -- containing displayable octets (aka ASCII) FcWwn ::= OCTET STRING (SIZE(8)) SwDomainIndex ::= INTEGER (0..31) SwNbIndex ::= INTEGER (0..2048) SwSensorIndex ::= INTEGER (1..1024) bcsi OBJECT IDENTIFIER ::= { enterprises 1588 } -- Product Lines or Generic Product information -- { bcsi 1 } is reserved commDev OBJECT IDENTIFIER ::= { bcsi 2 } -- communication devices fibrechannel OBJECT IDENTIFIER ::= { commDev 1 } fcSwitch OBJECT IDENTIFIER ::= { fibrechannel 1 } sw OBJECT IDENTIFIER ::= { fcSwitch 1 } -- various groups swSystem OBJECT IDENTIFIER ::= { sw 1 } swFabric OBJECT IDENTIFIER ::= { sw 2 } swModule OBJECT IDENTIFIER ::= { sw 3 } swAgtCfg OBJECT IDENTIFIER ::= { sw 4 } -- { sw 5 } is reserved swFCport OBJECT IDENTIFIER ::= { sw 6 } swNs OBJECT IDENTIFIER ::= { sw 7 } swEvent OBJECT IDENTIFIER ::= { sw 8 } -- -- the System Group (sw) -- swCurrentDate OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "The current date information in displayable textual format." ::= { swSystem 1 } swBootDate OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "The date and time when the system last booted, in displaybale textual format." ::= { swSystem 2 } swFWLastUpdated OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "The information indicates the date when the firmware was last updated, in displayable textual format." ::= { swSystem 3 } swFlashLastUpdated OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The information indicates the date when the FLASH was last updated, in displayable textual format." ::= { swSystem 4 } swBootPromLastUpdated OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "The information indicates the date when the boot PROM was last updated, in displayable textual format." ::= { swSystem 5 } swFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (24)) ACCESS read-only STATUS mandatory DESCRIPTION "The current version of the firwmare." ::= { swSystem 6 } swOperStatus OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2), testing (3), faulty (4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational status of the switch. The states are as follow: o online(1) means the switch is accessible by an external Fibre Channel port; o offline(2) means the switch is not accesible; o testing(3) means the switch is in a built-in test mode and is not accessible by an external Fibre Channel port; o faulty(4) means the switch is not operational." ::= { swSystem 7 } swAdmStatus OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2), testing (3), faulty (4), reboot (5), fastboot(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired administrative status of the switch. A management station may place the switch in a desired state by setting this object accordingly. The states are as follow: o online(1) means set the switch to be accessible by an external Fibre Channel port; o offline(2) means set the switch to be inaccesible; o testing(3) means set the switch to run the built-in test; o faulty(4) means set the switch to a 'soft' faulty condition; o reboot(5) means set the switch to reboot in 1 second. o fastboot(6) means set the switch to fastboot in 1 second. Fastboot would cause the switch to boot but skip over the POST. When the switch is in faulty state, only two states can be set: faulty and reboot/fastboot." ::= { swSystem 8 } -- 9..10 are reserved -- FLASH administration -- the next 5 objects are related to FlashDownload -- -- 2 steps to download a new firmware into the switch FLASH, -- (A) set swFlashDLHost.0, swFlashDLUser.0 and swFlashDLFile.0 to -- appropriate -- host IP address in user dot notation (e.g. 192.168.1.7), -- user name (e.g. "administrator"), and -- file name of the firmware (e.g. "/home/fcswitch/v2.0") -- respectively; -- (B) set swFlashDLAdmStatus.0 to sw-upgraded(2) swFlashDLOperStatus OBJECT-TYPE SYNTAX INTEGER { sw-current (1), sw-upgraded (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the boot FLASH. The operational states are as follow: o current(1) indicates that the boot FLASH contains the current firmware image; and o upgraded(2) state indicates that it contains the image upgraded from the swFlashDLHost.0." ::= { swSystem 11 } swFlashDLAdmStatus OBJECT-TYPE SYNTAX INTEGER { sw-current (1), sw-upgraded (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of the boot FLASH. A management station may place the boot FLASH in a desired state by setting this object accordingly. The sw-upgraded(2) state indicates that the boot FLASH shall be upgraded from the host specified in swFlashDLHost.0, with the user name specified in swFlashDLUser.0, and the new firmware image file specified in swFlashDLFile.0." ::= { swSystem 12 } swFlashDLHost OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "The name or IP address (in dot notation) of the host to download the firmware image to the FLASH." ::= { swSystem 13 } swFlashDLUser OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "The user name on the host to download the firmware image to the boot FLASH." ::= { swSystem 14 } swFlashDLFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) ACCESS read-write STATUS mandatory DESCRIPTION "The file name of the firmware image." ::= { swSystem 15 } -- 16..19 are reserved swDiagResult OBJECT-TYPE SYNTAX INTEGER { sw-ok (1), sw-central-memory-fault (2), sw-embedded-port-fault (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The result of the power-on startup (POST) diagnostics." ::= { swSystem 20 } -- operating environment sensors (temperature, fan, power supply...) swNumSensors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of sensors inside the switch." ::= { swSystem 21 } swSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF SwSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of sensor entries." ::= { swSystem 22 } swSensorEntry OBJECT-TYPE SYNTAX SwSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the sensor information." INDEX { swSensorIndex } ::= { swSensorTable 1 } SwSensorEntry ::= SEQUENCE { swSensorIndex SwSensorIndex, swSensorType INTEGER, swSensorStatus INTEGER, swSensorValue INTEGER, swSensorInfo DisplayString (SIZE(256)) } swSensorIndex OBJECT-TYPE SYNTAX SwSensorIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the sensor." ::= { swSensorEntry 1 } swSensorType OBJECT-TYPE SYNTAX INTEGER { temperature (1), fan (2), power-supply (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the sensor type." ::= { swSensorEntry 2 } swSensorStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), faulty (2), below-min (3), nominal (4), above-max (5), absent (6) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the sensor." ::= { swSensorEntry 3 } swSensorValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current value of the sensor. The value, -2147483648, represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value. In V1.6, the temperature sensor value will be in Celsius; the fan and power supply sensor reading will be unknown." ::= { swSensorEntry 4 } swSensorInfo OBJECT-TYPE SYNTAX DisplayString (SIZE(256)) ACCESS read-only STATUS mandatory DESCRIPTION "Additional displayable information on the sensor. In V1.6, it contains the sensor type and number in textual format. For example, 'Temp 3', 'Fan 6'." ::= { swSensorEntry 5 } -- -- End of System Group -- -- -- Fabric Group -- swDomainID OBJECT-TYPE SYNTAX SwDomainIndex ACCESS read-write STATUS mandatory DESCRIPTION "The current Fibre Channel domain ID of the switch. To set a new value, the switch (swAdmStatus) must be in offline or testing state." ::= { swFabric 1 } swPrincipalSwitch OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates whether the switch is the Principal switch as per FC-SW." ::= { swFabric 2 } -- swFabric 3..7 are reserved -- (immediate) Neighborhood ISL family -- swNumNbs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Inter-Switch Links in the (immediate) neighborhood." ::= { swFabric 8 } swNbTable OBJECT-TYPE SYNTAX SEQUENCE OF SwNbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the ISLs in the immediate neighorhood of the switch." ::= { swFabric 9 } swNbEntry OBJECT-TYPE SYNTAX SwNbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing each neighbor ISL parameters." INDEX { swNbIndex } ::= { swNbTable 1 } SwNbEntry ::= SEQUENCE { swNbIndex SwNbIndex, swNbMyPort INTEGER, swNbRemDomain SwDomainIndex, swNbRemPort INTEGER, swNbBaudRate INTEGER, swNbIslState INTEGER } swNbIndex OBJECT-TYPE SYNTAX SwNbIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the neighbour ISL entry." ::= { swNbEntry 1 } swNbMyPort OBJECT-TYPE SYNTAX INTEGER { portNum-0 (1), portNum-1 (2), portNum-2 (3), portNum-3 (4), portNum-4 (5), portNum-5 (6), portNum-6 (7), portNum-7 (8), portNum-8 (9), portNum-9 (10), portNum-10 (11), portNum-11 (12), portNum-12 (13), portNum-13 (14), portNum-14 (15), portNum-15 (16) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the port that has an ISL to another switch." ::= { swNbEntry 2 } swNbRemDomain OBJECT-TYPE SYNTAX SwDomainIndex ACCESS read-only STATUS mandatory DESCRIPTION "This is the Fibre Channel domain on the other end of the ISL." ::= { swNbEntry 3 } swNbRemPort OBJECT-TYPE SYNTAX INTEGER { portNum-0 (1), portNum-1 (2), portNum-2 (3), portNum-3 (4), portNum-4 (5), portNum-5 (6), portNum-6 (7), portNum-7 (8), portNum-8 (9), portNum-9 (10), portNum-10 (11), portNum-11 (12), portNum-12 (13), portNum-13 (14), portNum-14 (15), portNum-15 (16) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the port index on the other end of the ISL." ::= { swNbEntry 4 } swNbBaudRate OBJECT-TYPE SYNTAX INTEGER { other (1), -- none of below oneEighth (2), -- 155 Mbaud quarter (4), -- 266 Mbaud half (8), -- 532 Mbaud full (16), -- 1 Gbaud double (32), -- 2 Gbaud quadruple (64) -- 4 Gbaud } ACCESS read-only STATUS mandatory DESCRIPTION "The baud rate of the ISL." ::= { swNbEntry 5 } swNbIslState OBJECT-TYPE SYNTAX INTEGER { -- sw-down (0), sw-init (1), sw-internal2 (2), sw-internal3 (3), sw-internal4 (4), sw-active (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the ISL." ::= { swNbEntry 6 } -- -- SNMP Agent Configuration -- -- swAgtCfg 1..10 are reserved swAgtCmtyTable OBJECT-TYPE SYNTAX SEQUENCE OF SwAgtCmtyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each Community, the access control and parameters of the Community." ::= { swAgtCfg 11 } swAgtCmtyEntry OBJECT-TYPE SYNTAX SwAgtCmtyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the Community parameters." INDEX { swAgtCmtyIdx } ::= { swAgtCmtyTable 1 } SwAgtCmtyEntry ::= SEQUENCE { swAgtCmtyIdx INTEGER (1..6), swAgtCmtyStr DisplayString (SIZE (16)), swAgtTrapRcp NetworkAddress } swAgtCmtyIdx OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the SNMPv1 Community entry." ::= { swAgtCmtyEntry 1 } swAgtCmtyStr OBJECT-TYPE SYNTAX DisplayString (SIZE (16)) ACCESS read-write STATUS mandatory DESCRIPTION "This is a Community string supported by the agent. If a new value is set successfully, it takes effect immediately." ::= { swAgtCmtyEntry 2 } swAgtTrapRcp OBJECT-TYPE SYNTAX NetworkAddress ACCESS read-write STATUS mandatory DESCRIPTION "This is the trap recipient associated with the Community. If a new value is set successfully, it takes effect immediately." ::= { swAgtCmtyEntry 3 } -- -- End of SNMP Agent Configuration Group -- -- -- Fibre Channel Port Group -- This group contains information about the physical state, -- operational status, performance and error statistics of each -- Fibre Channel port on the switch. A Fibre Channel port is one which -- supports the Fibre Channel protocol. E.g. F_Port, E_Port, FL_Port. -- swFCPortCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of Fibre Channel ports on this switch. It includes G_Port, F_Port, FL_Port and any other types of Fibre Channel port." ::= { swFCport 1 } swFCPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SwFCPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains, one entry for each switch port, configuration and service parameters of the port." ::= { swFCport 2 } swFCPortEntry OBJECT-TYPE SYNTAX SwFCPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the configuration and service parameters of the switch port." INDEX { swFCPortIndex } ::= { swFCPortTable 1 } SwFCPortEntry ::= SEQUENCE { swFCPortIndex INTEGER, swFCPortType INTEGER, swFCPortPhyState INTEGER, swFCPortOpStatus INTEGER, swFCPortAdmStatus INTEGER, -- the rest is mapped to gstat_t swFCPortTxWords Counter, swFCPortRxWords Counter, swFCPortTxFrames Counter, swFCPortRxFrames Counter, swFCPortTxC2Frames Counter, swFCPortRxC3Frames Counter, swFCPortRxLCs Counter, swFCPortRxMcasts Counter, swFCPortTooManyRdys Counter, swFCPortNoTxCredits Counter, swFCPortRxEncInFrs Counter, swFCPortRxCrcs Counter, swFCPortRxTruncs Counter, swFCPortRxTooLongs Counter, swFCPortRxBadEofs Counter, swFCPortRxEncOutFrs Counter, swFCPortRxBadOs Counter, swFCPortC3Discards Counter, swFCPortMcastTimedOuts Counter, swFCPortTxMcasts Counter, -- LIP statistics swFCPortLipIns Counter, swFCPortLipOuts Counter, swFCPortLipLastAlpa OCTET STRING (SIZE(4)) } swFCPortIndex OBJECT-TYPE SYNTAX INTEGER { portNum-0 (1), portNum-1 (2), portNum-2 (3), portNum-3 (4), portNum-4 (5), portNum-5 (6), portNum-6 (7), portNum-7 (8), portNum-8 (9), portNum-9 (10), portNum-10 (11), portNum-11 (12), portNum-12 (13), portNum-13 (14), portNum-14 (15), portNum-15 (16) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the switch port index. Note that the value of a port index is 1 higher than the port number labeled on the front panel. E.g. port index 1 correspond to port number 0." ::= { swFCPortEntry 1 } swFCPortType OBJECT-TYPE SYNTAX INTEGER { stitch (1), flannel (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the type of switch port. It may be of type stitch(1) or flannel(2)." ::= { swFCPortEntry 2 } swFCPortPhyState OBJECT-TYPE SYNTAX INTEGER { noCard (1), noGbic (2), laserFault (3), noLight (4), noSync (5), inSync (6), portFault (7), diagFault (8), lockRef (9) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the physical state of the port: noCard(1) no card present in this switch slot; noGbic(2) no GBIC module in this port; laserFault(3) the module is signaling a laser fault (defective GBIC); noLight(4) the module is not receiving light; noSync(5) the module is receiving light but is out of sync; inSync(6) the module is receiving light and is in sync; portFault(7) the port is marked faulty (defective GBIC, cable or device); diagFault(8) the port failed diagnostics (defective G_Port or FL_Port card or motherboard); lockRef(9) the port is locking to the reference signal. " ::= { swFCPortEntry 3 } swFCPortOpStatus OBJECT-TYPE SYNTAX INTEGER { unknown (0), online (1), offline (2), testing (3), faulty (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the operational status of the port. The online(1) state indicates that user frames can be passed. The unknown(0) state indicates that likely the port module is physically absent (see swFCPortPhyState)." ::= { swFCPortEntry 4 } swFCPortAdmStatus OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2), testing (3), faulty (4) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates that no user frames can be passed. As the result of either explicit management action or per configuration information accessible by the switch, swFCPortAdmStatus is then changed to either the online(1) or testing(3) states, or remains in the offline(2) state." ::= { swFCPortEntry 5 } swFCPortTxWords OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Fibre Channel words that the port has transmitted." ::= { swFCPortEntry 11 } swFCPortRxWords OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Fibre Channel words that the port has received." ::= { swFCPortEntry 12 } swFCPortTxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of (Fibre Channel) frames that the port has transmitted." ::= { swFCPortEntry 13 } swFCPortRxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of (Fibre Channel) frames that the port has received." ::= { swFCPortEntry 14 } swFCPortTxC2Frames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Class 2 frames that the port has transmitted." ::= { swFCPortEntry 15 } swFCPortRxC3Frames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Class 3 frames that the port has received." ::= { swFCPortEntry 16 } swFCPortRxLCs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Link Control frames that the port has received." ::= { swFCPortEntry 17 } swFCPortRxMcasts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Multicast frames that the port has received." ::= { swFCPortEntry 18 } swFCPortTooManyRdys OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of times when RDYs exceeds the frames received." ::= { swFCPortEntry 19 } swFCPortNoTxCredits OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of times when the transmit credit has reached zero." ::= { swFCPortEntry 20 } swFCPortRxEncInFrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of encoding error or disparity error inside frames received." ::= { swFCPortEntry 21 } swFCPortRxCrcs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of CRC errors detected for frames received." ::= { swFCPortEntry 22 } swFCPortRxTruncs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of truncated frames that the port has received." ::= { swFCPortEntry 23 } swFCPortRxTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of received frames that are too long." ::= { swFCPortEntry 24 } swFCPortRxBadEofs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of received frames that have bad EOF delimiter." ::= { swFCPortEntry 25 } swFCPortRxEncOutFrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of encoding error or disparity error outside frames received." ::= { swFCPortEntry 26 } swFCPortRxBadOs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of invalid Ordered Sets received." ::= { swFCPortEntry 27 } swFCPortC3Discards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Class 3 frames that the port has discarded." ::= { swFCPortEntry 28 } swFCPortMcastTimedOuts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Multicast frames that has been timed out." ::= { swFCPortEntry 29 } swFCPortTxMcasts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Multicast frames that has been transmitted." ::= { swFCPortEntry 30 } -- LIP statistics swFCPortLipIns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Loop Initializations that has been initiated by loop devices attached." ::= { swFCPortEntry 31 } swFCPortLipOuts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Loop Initializations that has been initiated by the port." ::= { swFCPortEntry 32 } swFCPortLipLastAlpa OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the Physical Address (AL_PA) of the loop device that initiated the last Loop Initialization." ::= { swFCPortEntry 33 } -- -- End of Fibre Channel Port group -- -- -- The Name Server Database group -- swNsLocalNumEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of local Name Server entries." ::= { swNs 1 } swNsLocalTable OBJECT-TYPE SYNTAX SEQUENCE OF SwNsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of local Name Server entries." ::= { swNs 2 } swNsLocalEntry OBJECT-TYPE SYNTAX SwNsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the local Name Server database." INDEX { swNsPortIndex } ::= { swNsLocalTable 1 } SwNsEntry ::= SEQUENCE { swNsPortIndex INTEGER, swNsPortID OCTET STRING(SIZE(4)), swNsPortType INTEGER, swNsPortName FcWwn, swNsPortSymb OCTET STRING, swNsNodeName FcWwn, swNsNodeSymb OCTET STRING, swNsIPA OCTET STRING, swNsIpAddress OCTET STRING, swNsCos INTEGER, swNsFc4 OCTET STRING } swNsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the Name Server database entry." ::= { swNsLocalEntry 1 } swNsPortID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the Fibre Channel port address ID of the entry." ::= { swNsLocalEntry 2 } swNsPortType OBJECT-TYPE SYNTAX INTEGER { -- unknown (0), nPort (1), nlPort (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the type of port: N_Port, NL_Port, etc., for this entry. The type is defined in FC-GS-2." ::= { swNsLocalEntry 3 } swNsPortName OBJECT-TYPE SYNTAX FcWwn ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the Fibre Channel World_wide Name of the port entry." ::= { swNsLocalEntry 4 } swNsPortSymb OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the contents of a Symbolic Name of the port entry. In FC-GS-2, a Symbolic Name consists of a byte array of 1 through 256 bytes, and the first byte of the array specifies the length of its 'contents'. This object variable corresponds to the 'contents' of the Symbolic Name, without the first byte." ::= { swNsLocalEntry 5 } swNsNodeName OBJECT-TYPE SYNTAX FcWwn ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the Fibre Channel World_wide Name of the associated node as defined in FC-GS-2." ::= { swNsLocalEntry 6 } swNsNodeSymb OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the contents of a Symbolic Name of the the node associated with the entry. In FC-GS-2, a Symbolic Name consists of a byte array of 1 through 256 bytes, and the first byte of the array specifies the length of its 'contents'. This object variable corresponds to the 'contents' of the Symbolic Name, without the first byte (specifying the length)." ::= { swNsLocalEntry 7 } swNsIPA OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the Initial Process Associator of the node for the entry as defined in FC-GS-2." ::= { swNsLocalEntry 8 } swNsIpAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the IP address of the node for the entry as defined in FC-GS-2. The format of the address is in IPv6." ::= { swNsLocalEntry 9 } swNsCos OBJECT-TYPE SYNTAX INTEGER { -- class-unknown (0), class-F (1), class-1 (2), class-F-1 (3), class-2 (4), class-F-2 (5), class-1-2 (6), class-F-1-2 (7), class-3 (8), class-F-3 (9), class-1-3 (10), class-F-1-3 (11), class-2-3 (12), class-F-2-3 (13), class-1-2-3 (14), class-F-1-2-3 (15) -- more to enumerate in future. } ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the class of services supported by the port. The value is a bit-map defined as follows: o bit 0 is class F, o bit 1 is class 1, o bit 2 is class 2, o bit 3 is class 3, o bit 4 is class 4, etc." ::= { swNsLocalEntry 10 } swNsFc4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) ACCESS read-only STATUS mandatory DESCRIPTION "The object identifies the FC-4s supported by the port as defined in FC-GS-2." ::= { swNsLocalEntry 11 } -- -- End of Fibre Channel Name Server group -- -- ####################################################################### -- -- Event Group - to map the errLog initially -- -- NOTE -- The initial implementation of this group has a restriction on the size -- of the swEventTable: it would have at most one entry; and the value of -- the swEventNumEntries will be 1. -- Logically, swEventTable is separate from the error log since it is -- essentially a view of the error log within a particular time window. -- Due to the way the error log is implemented, and the way a MIB table -- may be retrieved via SNMP, it is our recommendation that the size -- of this view be restricted to 1 entry at this time. -- The value of swEventIndex shall indicate the event number that has -- occurred since the switch booted. The value will range from 1 through -- 2147383647 (2^31 - 1). -- -- This table size restriction may be removed in future firmware release. -- It's recommended that the SNMP management application makes use of -- the value of swEventNumEntries such that when the restriction is -- removed in future, it will adapt seamlessly to the table size if it -- were to retrieve the table. -- -- ####################################################################### swEventTrapLevel OBJECT-TYPE SYNTAX INTEGER { critical (1), error (2), warning (3), informational (4), debug (5) } ACCESS read-write STATUS mandatory DESCRIPTION "The level at or below which events whose severity level will be sent as a trap, swEventTrap, to configured trap recipients." ::= { swEvent 1 } -- { swEvent 2..3 are reserved } swEventNumEntries OBJECT-TYPE SYNTAX INTEGER (1..30) ACCESS read-only STATUS mandatory DESCRIPTION "The number of entries in the Event Table." ::= { swEvent 4 } -- ******************************************************************* -- -- The Event Table is an abstraction of the error log table -- within the switch. -- Due to the difficulty in mapping the event index to the actual -- error log entry, this table will only have one entry - the latest -- error log entry. -- This restriction may be removed in future enhancement. -- -- ******************************************************************* swEventTable OBJECT-TYPE SYNTAX SEQUENCE OF SwEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of event entries." ::= { swEvent 5 } swEventEntry OBJECT-TYPE SYNTAX SwEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the event table." INDEX { swEventIndex } ::= { swEventTable 1 } SwEventEntry ::= SEQUENCE { swEventIndex INTEGER, swEventTimeInfo DisplayString, swEventLevel INTEGER, swEventRepeatCount INTEGER, swEventDescr DisplayString } swEventIndex OBJECT-TYPE SYNTAX INTEGER (1..30) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the event entry." ::= { swEventEntry 1 } swEventTimeInfo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the date and time when this event occurred, in textual format." ::= { swEventEntry 2 } swEventLevel OBJECT-TYPE SYNTAX INTEGER { critical (1), error (2), warning (3), informational (4), debug (5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the severity level of this event entry." ::= { swEventEntry 3 } swEventRepeatCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies how many times this particular event has occurred." ::= { swEventEntry 4 } swEventDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the textual description of the event." ::= { swEventEntry 5 } -- -- End of Fibre Channel Event Group -- END