Nortel-Magellan-Passport-DisdnNI2MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 passportMIBs FROM Nortel-Magellan-Passport-UsefulDefinitionsMIB DisplayString, StorageType, RowStatus, Unsigned32 FROM Nortel-Magellan-Passport-StandardTextualConventionsMIB NonReplicated, Link FROM Nortel-Magellan-Passport-TextualConventionsMIB dataSigChanIndex, dataSigChan FROM Nortel-Magellan-Passport-DataIsdnMIB; -- LAST-UPDATED "9808030000Z" -- ORGANIZATION "Nortel" -- CONTACT-INFO " -- Nortel Magellan Network Management -- -- Postal: P.O. Box 5080, Station F -- Ottawa, Ontario -- Canada K2C 3T1 -- -- Email: nm_plm@nt.com" -- DESCRIPTION -- "The module describing the Nortel Magellan Passport -- DisdnNI2 Enterprise MIB." disdnNI2MIB OBJECT IDENTIFIER ::= { passportMIBs 126 } -- DataSigChan/n NationalIsdn2 -- The Ni2 component defines the operational characteristics of the -- signalling channel's connection to the external equipment. dataSigChanNi2 OBJECT IDENTIFIER ::= { dataSigChan 12 } dataSigChanNi2RowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2RowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of dataSigChanNi2 components." ::= { dataSigChanNi2 1 } dataSigChanNi2RowStatusEntry OBJECT-TYPE SYNTAX DataSigChanNi2RowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single dataSigChanNi2 component." INDEX { dataSigChanIndex, dataSigChanNi2Index } ::= { dataSigChanNi2RowStatusTable 1 } DataSigChanNi2RowStatusEntry ::= SEQUENCE { dataSigChanNi2RowStatus RowStatus, dataSigChanNi2ComponentName DisplayString, dataSigChanNi2StorageType StorageType, dataSigChanNi2Index NonReplicated } dataSigChanNi2RowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of dataSigChanNi2 components. These components can be added and deleted." ::= { dataSigChanNi2RowStatusEntry 1 } dataSigChanNi2ComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { dataSigChanNi2RowStatusEntry 2 } dataSigChanNi2StorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the dataSigChanNi2 tables." ::= { dataSigChanNi2RowStatusEntry 4 } dataSigChanNi2Index OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the dataSigChanNi2 tables." ::= { dataSigChanNi2RowStatusEntry 10 } dataSigChanNi2L2Table OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2L2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group represents the provisionable Layer 2 attributes of the Q931 CCITT protocol." ::= { dataSigChanNi2 11 } dataSigChanNi2L2Entry OBJECT-TYPE SYNTAX DataSigChanNi2L2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dataSigChanNi2L2Table." INDEX { dataSigChanIndex, dataSigChanNi2Index } ::= { dataSigChanNi2L2Table 1 } DataSigChanNi2L2Entry ::= SEQUENCE { dataSigChanNi2T23 Unsigned32, dataSigChanNi2T200 Unsigned32, dataSigChanNi2N200 Unsigned32, dataSigChanNi2T203 Unsigned32, dataSigChanNi2N201 Unsigned32, dataSigChanNi2CircuitSwitchedK Unsigned32 } dataSigChanNi2T23 OBJECT-TYPE SYNTAX Unsigned32 (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the layer2 enable request timer." DEFVAL { 10 } ::= { dataSigChanNi2L2Entry 1 } dataSigChanNi2T200 OBJECT-TYPE SYNTAX Unsigned32 (1..20) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum time between a layer 2 frame and its acknowledgement" DEFVAL { 2 } ::= { dataSigChanNi2L2Entry 2 } dataSigChanNi2N200 OBJECT-TYPE SYNTAX Unsigned32 (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of re-transmissions of a layer2 frame." DEFVAL { 3 } ::= { dataSigChanNi2L2Entry 3 } dataSigChanNi2T203 OBJECT-TYPE SYNTAX Unsigned32 (2..40) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum time that a no layer 2 traffic situation can last. Expiry triggers a check on whether the far end is a live." DEFVAL { 10 } ::= { dataSigChanNi2L2Entry 4 } dataSigChanNi2N201 OBJECT-TYPE SYNTAX Unsigned32 (4..260) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of octets in an information field." DEFVAL { 260 } ::= { dataSigChanNi2L2Entry 5 } dataSigChanNi2CircuitSwitchedK OBJECT-TYPE SYNTAX Unsigned32 (1..632) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the maximum number of frames for B channel use." DEFVAL { 7 } ::= { dataSigChanNi2L2Entry 6 } dataSigChanNi2ProvTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2ProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group defines the general options of the d-channel signalling link." ::= { dataSigChanNi2 13 } dataSigChanNi2ProvEntry OBJECT-TYPE SYNTAX DataSigChanNi2ProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dataSigChanNi2ProvTable." INDEX { dataSigChanIndex, dataSigChanNi2Index } ::= { dataSigChanNi2ProvTable 1 } DataSigChanNi2ProvEntry ::= SEQUENCE { dataSigChanNi2Side INTEGER } dataSigChanNi2Side OBJECT-TYPE SYNTAX INTEGER { network(1), user(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether the layer 2 HDLC interface is the network or user side of the connection." DEFVAL { user } ::= { dataSigChanNi2ProvEntry 1 } dataSigChanNi2OperTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2OperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group provides the operational attributes for the signalling protocol." ::= { dataSigChanNi2 15 } dataSigChanNi2OperEntry OBJECT-TYPE SYNTAX DataSigChanNi2OperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dataSigChanNi2OperTable." INDEX { dataSigChanIndex, dataSigChanNi2Index } ::= { dataSigChanNi2OperTable 1 } DataSigChanNi2OperEntry ::= SEQUENCE { dataSigChanNi2ActiveChannels Unsigned32, dataSigChanNi2PeakActiveChannels Unsigned32, dataSigChanNi2DChanStatus INTEGER } dataSigChanNi2ActiveChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of currently active channels. This includes data and voice channels." DEFVAL { 0 } ::= { dataSigChanNi2OperEntry 1 } dataSigChanNi2PeakActiveChannels OBJECT-TYPE SYNTAX Unsigned32 (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period." DEFVAL { 0 } ::= { dataSigChanNi2OperEntry 4 } dataSigChanNi2DChanStatus OBJECT-TYPE SYNTAX INTEGER { outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei- initialized." ::= { dataSigChanNi2OperEntry 7 } dataSigChanNi2ToolsTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2ToolsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains a series of operational attributes which turn on and off several kinds of tracing." ::= { dataSigChanNi2 16 } dataSigChanNi2ToolsEntry OBJECT-TYPE SYNTAX DataSigChanNi2ToolsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dataSigChanNi2ToolsTable." INDEX { dataSigChanIndex, dataSigChanNi2Index } ::= { dataSigChanNi2ToolsTable 1 } DataSigChanNi2ToolsEntry ::= SEQUENCE { dataSigChanNi2Tracing OCTET STRING } dataSigChanNi2Tracing OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)" ::= { dataSigChanNi2ToolsEntry 1 } -- -- DataSigChan/n ts014 Framer -- -- The Framer component controls link layer framing for application -- components sending and receiving data on a link interface. It is also -- through Framer, that an application component is associated with a -- specific hardware link interface. -- -- The Framer component provides provisionable attributes related to -- datapath aspects of the hardware interface (such as crc and frame -- length). The Framer component also provides a provisionable -- attribute which binds the application component to a specific -- hardware component. -- -- The Framer component contains operational attributes for link -- interface datapath statistics (such as frame counts and aborts). -- dataSigChanNi2Framer OBJECT IDENTIFIER ::= { dataSigChanNi2 2 } dataSigChanNi2FramerRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2FramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of dataSigChanNi2Framer components." ::= { dataSigChanNi2Framer 1 } dataSigChanNi2FramerRowStatusEntry OBJECT-TYPE SYNTAX DataSigChanNi2FramerRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single dataSigChanNi2Framer component." INDEX { dataSigChanIndex, dataSigChanNi2Index, dataSigChanNi2FramerIndex } ::= { dataSigChanNi2FramerRowStatusTable 1 } DataSigChanNi2FramerRowStatusEntry ::= SEQUENCE { dataSigChanNi2FramerRowStatus RowStatus, dataSigChanNi2FramerComponentName DisplayString, dataSigChanNi2FramerStorageType StorageType, dataSigChanNi2FramerIndex NonReplicated } dataSigChanNi2FramerRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of dataSigChanNi2Framer components. These components cannot be added nor deleted." ::= { dataSigChanNi2FramerRowStatusEntry 1 } dataSigChanNi2FramerComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { dataSigChanNi2FramerRowStatusEntry 2 } dataSigChanNi2FramerStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the dataSigChanNi2Framer tables." ::= { dataSigChanNi2FramerRowStatusEntry 4 } dataSigChanNi2FramerIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the dataSigChanNi2Framer tables." ::= { dataSigChanNi2FramerRowStatusEntry 10 } dataSigChanNi2FramerProvTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2FramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups." ::= { dataSigChanNi2Framer 10 } dataSigChanNi2FramerProvEntry OBJECT-TYPE SYNTAX DataSigChanNi2FramerProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dataSigChanNi2FramerProvTable." INDEX { dataSigChanIndex, dataSigChanNi2Index, dataSigChanNi2FramerIndex } ::= { dataSigChanNi2FramerProvTable 1 } DataSigChanNi2FramerProvEntry ::= SEQUENCE { dataSigChanNi2FramerInterfaceName Link } dataSigChanNi2FramerInterfaceName OBJECT-TYPE SYNTAX Link ACCESS read-write STATUS mandatory DESCRIPTION "This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run." ::= { dataSigChanNi2FramerProvEntry 1 } dataSigChanNi2FramerStateTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2FramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { dataSigChanNi2Framer 12 } dataSigChanNi2FramerStateEntry OBJECT-TYPE SYNTAX DataSigChanNi2FramerStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dataSigChanNi2FramerStateTable." INDEX { dataSigChanIndex, dataSigChanNi2Index, dataSigChanNi2FramerIndex } ::= { dataSigChanNi2FramerStateTable 1 } DataSigChanNi2FramerStateEntry ::= SEQUENCE { dataSigChanNi2FramerAdminState INTEGER, dataSigChanNi2FramerOperationalState INTEGER, dataSigChanNi2FramerUsageState INTEGER } dataSigChanNi2FramerAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { dataSigChanNi2FramerStateEntry 1 } dataSigChanNi2FramerOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { dataSigChanNi2FramerStateEntry 2 } dataSigChanNi2FramerUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { dataSigChanNi2FramerStateEntry 3 } dataSigChanNi2FramerStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF DataSigChanNi2FramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the operational statistics data for a Framer component." ::= { dataSigChanNi2Framer 13 } dataSigChanNi2FramerStatsEntry OBJECT-TYPE SYNTAX DataSigChanNi2FramerStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dataSigChanNi2FramerStatsTable." INDEX { dataSigChanIndex, dataSigChanNi2Index, dataSigChanNi2FramerIndex } ::= { dataSigChanNi2FramerStatsTable 1 } DataSigChanNi2FramerStatsEntry ::= SEQUENCE { dataSigChanNi2FramerFrmToIf Unsigned32, dataSigChanNi2FramerFrmFromIf Unsigned32, dataSigChanNi2FramerOctetFromIf Unsigned32, dataSigChanNi2FramerAborts Unsigned32, dataSigChanNi2FramerCrcErrors Unsigned32, dataSigChanNi2FramerLrcErrors Unsigned32, dataSigChanNi2FramerNonOctetErrors Unsigned32, dataSigChanNi2FramerOverruns Unsigned32, dataSigChanNi2FramerUnderruns Unsigned32, dataSigChanNi2FramerLargeFrmErrors Unsigned32 } dataSigChanNi2FramerFrmToIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 1 } dataSigChanNi2FramerFrmFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 2 } dataSigChanNi2FramerOctetFromIf OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received from the link interface by Framer." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 3 } dataSigChanNi2FramerAborts OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 4 } dataSigChanNi2FramerCrcErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 5 } dataSigChanNi2FramerLrcErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 6 } dataSigChanNi2FramerNonOctetErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 7 } dataSigChanNi2FramerOverruns OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 8 } dataSigChanNi2FramerUnderruns OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 9 } dataSigChanNi2FramerLargeFrmErrors OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of frames received which were too large. The frame was longer than 500 bytes. This count wraps to zero after reaching its maximum value." DEFVAL { 0 } ::= { dataSigChanNi2FramerStatsEntry 10 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { dataSigChanNi2N200, -- dataSigChanNi2Side, -- dataSigChanNi2ComponentName, -- dataSigChanNi2FramerInterfaceName, -- dataSigChanNi2FramerFrmToIf, -- dataSigChanNi2T23, -- dataSigChanNi2FramerUnderruns, -- dataSigChanNi2CircuitSwitchedK, -- dataSigChanNi2FramerCrcErrors, -- dataSigChanNi2StorageType, -- dataSigChanNi2FramerOperationalState, -- dataSigChanNi2T200, -- dataSigChanNi2FramerLrcErrors, -- dataSigChanNi2FramerAborts, -- dataSigChanNi2FramerOctetFromIf, -- dataSigChanNi2T203, -- dataSigChanNi2DChanStatus, -- dataSigChanNi2FramerAdminState, -- dataSigChanNi2Tracing, -- dataSigChanNi2FramerStorageType, -- dataSigChanNi2FramerLargeFrmErrors, -- dataSigChanNi2RowStatus, -- dataSigChanNi2FramerRowStatus, -- dataSigChanNi2ActiveChannels, -- dataSigChanNi2FramerFrmFromIf, -- dataSigChanNi2N201, -- dataSigChanNi2FramerOverruns, -- dataSigChanNi2FramerNonOctetErrors, -- dataSigChanNi2PeakActiveChannels, -- dataSigChanNi2FramerUsageState, -- dataSigChanNi2FramerComponentName } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." disdnNI2Group OBJECT IDENTIFIER ::= { disdnNI2MIB 1 } disdnNI2GroupBE OBJECT IDENTIFIER ::= { disdnNI2Group 5 } disdnNI2GroupBE00 OBJECT IDENTIFIER ::= { disdnNI2GroupBE 1 } disdnNI2GroupBE00A OBJECT IDENTIFIER ::= { disdnNI2GroupBE00 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "Passport Release 7.0 DisdnNI2." -- STATUS mandatory -- DESCRIPTION "DisdnNI2 MIB: MIB Version BE00A, -- Software Version BG00S4C." -- SUPPORTS Nortel-Magellan-Passport-DisdnNI2MIB -- INCLUDES { disdnNI2GroupBE00A } disdnNI2Capabilities OBJECT IDENTIFIER ::= { disdnNI2MIB 3 } disdnNI2CapabilitiesBE OBJECT IDENTIFIER ::= { disdnNI2Capabilities 5 } disdnNI2CapabilitiesBE00 OBJECT IDENTIFIER ::= { disdnNI2CapabilitiesBE 1 } disdnNI2CapabilitiesBE00A OBJECT IDENTIFIER ::= { disdnNI2CapabilitiesBE00 2 } END