Nortel-Magellan-Passport-AtmIispMIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 passportMIBs FROM Nortel-Magellan-Passport-UsefulDefinitionsMIB Counter32, DisplayString, StorageType, RowStatus, Gauge32, Integer32, Unsigned32 FROM Nortel-Magellan-Passport-StandardTextualConventionsMIB Hex, NonReplicated, AsciiStringIndex FROM Nortel-Magellan-Passport-TextualConventionsMIB atmIfVptIndex, atmIfVpt, atmIfIndex, atmIf FROM Nortel-Magellan-Passport-AtmCoreMIB; -- LAST-UPDATED "9808030000Z" -- ORGANIZATION "Nortel" -- CONTACT-INFO " -- Nortel Magellan Network Management -- -- Postal: P.O. Box 5080, Station F -- Ottawa, Ontario -- Canada K2C 3T1 -- -- Email: nm_plm@nt.com" -- DESCRIPTION -- "The module describing the Nortel Magellan Passport -- AtmIisp Enterprise MIB." atmIispMIB OBJECT IDENTIFIER ::= { passportMIBs 70 } -- AtmIf/n Iisp -- This component represents an ATM Interim Inter-switch Signaling -- Protocol (IISP) interface. If this component is provisioned, the Uni -- component can not be provisioned under the same AtmIf -- component. If this component is deleted, then all associated Vcc -- components are deleted. atmIfIisp OBJECT IDENTIFIER ::= { atmIf 7 } atmIfIispRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfIisp components." ::= { atmIfIisp 1 } atmIfIispRowStatusEntry OBJECT-TYPE SYNTAX AtmIfIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfIisp component." INDEX { atmIfIndex, atmIfIispIndex } ::= { atmIfIispRowStatusTable 1 } AtmIfIispRowStatusEntry ::= SEQUENCE { atmIfIispRowStatus RowStatus, atmIfIispComponentName DisplayString, atmIfIispStorageType StorageType, atmIfIispIndex NonReplicated } atmIfIispRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfIisp components. These components can be added and deleted." ::= { atmIfIispRowStatusEntry 1 } atmIfIispComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfIispRowStatusEntry 2 } atmIfIispStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfIisp tables." ::= { atmIfIispRowStatusEntry 4 } atmIfIispIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfIisp tables." ::= { atmIfIispRowStatusEntry 10 } atmIfIispProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the Iisp component." ::= { atmIfIisp 10 } atmIfIispProvEntry OBJECT-TYPE SYNTAX AtmIfIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispProvTable." INDEX { atmIfIndex, atmIfIispIndex } ::= { atmIfIispProvTable 1 } AtmIfIispProvEntry ::= SEQUENCE { atmIfIispVersion INTEGER, atmIfIispSide INTEGER, atmIfIispSoftPvcRetryPeriod Unsigned32, atmIfIispSoftPvpAndPvcRetryPeriod Unsigned32, atmIfIispSoftPvpAndPvcHoldOffTime Unsigned32 } atmIfIispVersion OBJECT-TYPE SYNTAX INTEGER { iisp10Sig30(2), iisp10Sig31(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which specification the IISP interface complies with. The options are iisp10Sig30 which refers to IISP version 1.0 with 3.0 signalling and iisp10Sig31 which refers to IISP version 1.0 with 3.1 signalling. If this attribute is changed, all switched Vcc components in this interface are cleared due to the fact that the two versions are incompatible." DEFVAL { iisp10Sig31 } ::= { atmIfIispProvEntry 1 } atmIfIispSide OBJECT-TYPE SYNTAX INTEGER { networkSide(0), userSide(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which side the interface is, user or network." DEFVAL { networkSide } ::= { atmIfIispProvEntry 2 } atmIfIispSoftPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute specifies the time to wait between call set up retries. The resolution is to the nearest 10 seconds. This attribute has been obsoleted and is replaced by the softPvpAndPvcRetryPeriod attribute." DEFVAL { 60 } ::= { atmIfIispProvEntry 3 } atmIfIispSoftPvpAndPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the time to wait between soft PVP or soft PVC call setup retries. The resolution is to the nearest 10 seconds." DEFVAL { 60 } ::= { atmIfIispProvEntry 4 } atmIfIispSoftPvpAndPvcHoldOffTime OBJECT-TYPE SYNTAX Unsigned32 (0 | 50..20000) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies how long to hold off retries following a release or the connection. The resolution is to the nearest 50 ms." DEFVAL { 0 } ::= { atmIfIispProvEntry 5 } atmIfIispAcctOptTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for accounting." ::= { atmIfIisp 11 } atmIfIispAcctOptEntry OBJECT-TYPE SYNTAX AtmIfIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispAcctOptTable." INDEX { atmIfIndex, atmIfIispIndex } ::= { atmIfIispAcctOptTable 1 } AtmIfIispAcctOptEntry ::= SEQUENCE { atmIfIispAccountCollection OCTET STRING, atmIfIispAccountConnectionType INTEGER, atmIfIispAccountClass Unsigned32, atmIfIispServiceExchange Unsigned32 } atmIfIispAccountCollection OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to turn accounting on or off for SVC and SPVC connections. It also specifies the reason(s) for which accounting data is collected: billing, test, study, audit, or force. If the set of reasons is not empty then accounting records will be generated by this interface in the following situations: - on a TODA changeover if TODA is enabled; - every 12 hours (per connection) if TODA is disabled; - on every call clear (a call record with final cell counts). If none of the reasons is present, then accounting will be suppressed. The reason for collection is recorded in the accounting record, in the attribute callingCollectReason or calledCollectReason as appropriate. Description of bits: bill(0) test(1) study(2) audit(3) force(4)" ::= { atmIfIispAcctOptEntry 1 } atmIfIispAccountConnectionType OBJECT-TYPE SYNTAX INTEGER { origTerm(0), intermediate(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether accounting records generated by this interface should be marked as originating, terminating or intermediate. This attribute, in combination with the direction of the call, determines the value of attribute connPointType of the accounting record and may be used by downstream accounting processes to correlate the records. If the value is origTerm then records generated for incoming calls will be marked as originating and records generated for outgoing calls will be marked as terminating. If the value is intermediate then records generated for all calls will be marked as intermediate." DEFVAL { intermediate } ::= { atmIfIispAcctOptEntry 2 } atmIfIispAccountClass OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the accounting class associated with the interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingServiceType or calledServiceType as appropriate." DEFVAL { 0 } ::= { atmIfIispAcctOptEntry 3 } atmIfIispServiceExchange OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the data service exchange associated with this interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingDse or calledDse as appropriate." DEFVAL { 0 } ::= { atmIfIispAcctOptEntry 4 } -- AtmIf/n Iisp Signalling -- AtmIf/n Uni Signalling -- AtmIf/n Pnni Signalling -- AtmIf/n Vpt/m Iisp Signalling -- AtmIf/n Vpt/m Uni Signalling -- AtmIf/n Vpt/m Pnni Signalling -- -- This component represents the signalling entities for the interface. atmIfIispSig OBJECT IDENTIFIER ::= { atmIfIisp 3 } atmIfIispSigRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfIispSig components." ::= { atmIfIispSig 1 } atmIfIispSigRowStatusEntry OBJECT-TYPE SYNTAX AtmIfIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfIispSig component." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex } ::= { atmIfIispSigRowStatusTable 1 } AtmIfIispSigRowStatusEntry ::= SEQUENCE { atmIfIispSigRowStatus RowStatus, atmIfIispSigComponentName DisplayString, atmIfIispSigStorageType StorageType, atmIfIispSigIndex NonReplicated } atmIfIispSigRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfIispSig components. These components cannot be added nor deleted." ::= { atmIfIispSigRowStatusEntry 1 } atmIfIispSigComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfIispSigRowStatusEntry 2 } atmIfIispSigStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfIispSig tables." ::= { atmIfIispSigRowStatusEntry 4 } atmIfIispSigIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfIispSig tables." ::= { atmIfIispSigRowStatusEntry 10 } atmIfIispSigProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the Signalling component." ::= { atmIfIispSig 10 } atmIfIispSigProvEntry OBJECT-TYPE SYNTAX AtmIfIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispSigProvTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex } ::= { atmIfIispSigProvTable 1 } AtmIfIispSigProvEntry ::= SEQUENCE { atmIfIispSigVci Unsigned32, atmIfIispSigAddressConversion INTEGER } atmIfIispSigVci OBJECT-TYPE SYNTAX Unsigned32 (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the signalling channel number." DEFVAL { 5 } ::= { atmIfIispSigProvEntry 1 } atmIfIispSigAddressConversion OBJECT-TYPE SYNTAX INTEGER { none(0), nativeE164(1), nsap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the address conversion on the outgoing signalling PDUs. The options are none, nativeE164, or nsap. The none option is the default and if this option is chosen then nothing is done to the address information element (IE) in the outgoing signalling message. If nativeE164 option is chosen, then only NSAP encapsulated E.164 addresses with zeros in the ESI are converted to native E.164 format in the outgoing signalling message. If the NSAP address is not encapsulated E.164 or the ESI field is not zeros and the nativeE164 option is chosen, then the call is cleared. If the nsap option is chosen, then native E.164 addresses are converted to NSAP E.164 with zeros in the ESI field; otherwise the address is in NSAP format and is not changed." DEFVAL { none } ::= { atmIfIispSigProvEntry 2 } atmIfIispSigStateTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { atmIfIispSig 11 } atmIfIispSigStateEntry OBJECT-TYPE SYNTAX AtmIfIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispSigStateTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex } ::= { atmIfIispSigStateTable 1 } AtmIfIispSigStateEntry ::= SEQUENCE { atmIfIispSigAdminState INTEGER, atmIfIispSigOperationalState INTEGER, atmIfIispSigUsageState INTEGER } atmIfIispSigAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { atmIfIispSigStateEntry 1 } atmIfIispSigOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { atmIfIispSigStateEntry 2 } atmIfIispSigUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { atmIfIispSigStateEntry 3 } atmIfIispSigOperTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute contains the operational attributes for the AtmSignalling component." ::= { atmIfIispSig 12 } atmIfIispSigOperEntry OBJECT-TYPE SYNTAX AtmIfIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispSigOperTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex } ::= { atmIfIispSigOperTable 1 } AtmIfIispSigOperEntry ::= SEQUENCE { atmIfIispSigLastTxCauseCode Unsigned32, atmIfIispSigLastTxDiagCode Hex, atmIfIispSigLastRxCauseCode Unsigned32, atmIfIispSigLastRxDiagCode Hex } atmIfIispSigLastTxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the cause code in the last transmitted signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { atmIfIispSigOperEntry 1 } atmIfIispSigLastTxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last transmitted signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { atmIfIispSigOperEntry 2 } atmIfIispSigLastRxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the cause code in the last received signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { atmIfIispSigOperEntry 3 } atmIfIispSigLastRxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last received signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { atmIfIispSigOperEntry 4 } atmIfIispSigStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the statistics associated with the AtmSignalling component." ::= { atmIfIispSig 13 } atmIfIispSigStatsEntry OBJECT-TYPE SYNTAX AtmIfIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispSigStatsTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex } ::= { atmIfIispSigStatsTable 1 } AtmIfIispSigStatsEntry ::= SEQUENCE { atmIfIispSigCurrentConnections Counter32, atmIfIispSigPeakConnections Gauge32, atmIfIispSigSuccessfulConnections Counter32, atmIfIispSigFailedConnections Counter32, atmIfIispSigTxPdus Counter32, atmIfIispSigRxPdus Counter32, atmIfIispSigCurrentPmpConnections Gauge32, atmIfIispSigPeakPmpConnections Gauge32, atmIfIispSigSuccessfulPmpConnections Counter32, atmIfIispSigFailedPmpConnections Counter32, atmIfIispSigNewCurrentConnections Gauge32 } atmIfIispSigCurrentConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "This attribute indicates the total number of currently active connections." ::= { atmIfIispSigStatsEntry 1 } atmIfIispSigPeakConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- point and point-to-multipoint connections." ::= { atmIfIispSigStatsEntry 2 } atmIfIispSigSuccessfulConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- point and point-to-multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfIispSigStatsEntry 3 } atmIfIispSigFailedConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfIispSigStatsEntry 4 } atmIfIispSigTxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of transmitted signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfIispSigStatsEntry 5 } atmIfIispSigRxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of received signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfIispSigStatsEntry 6 } atmIfIispSigCurrentPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of currently active point-to- multipoint connections." ::= { atmIfIispSigStatsEntry 7 } atmIfIispSigPeakPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- multipoint connections." ::= { atmIfIispSigStatsEntry 8 } atmIfIispSigSuccessfulPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfIispSigStatsEntry 9 } atmIfIispSigFailedPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of switched point-to- multipoint connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfIispSigStatsEntry 10 } atmIfIispSigNewCurrentConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the total number of currently active point-to- point and point-to-multipoint connections." ::= { atmIfIispSigStatsEntry 11 } -- AtmIf/n Uni Sig VirtualChannelDescriptor -- AtmIf/n Uni Ilmi VirtualChannelDescriptor -- AtmIf/n Iisp Sig VirtualChannelDescriptor -- AtmIf/n Pnni Sig VirtualChannelDescriptor -- AtmIf/n Pnni Rcc VirtualChannelDescriptor -- AtmIf/n Vpt/m Uni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Iisp Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Rcc VirtualChannelDescriptor -- -- This component contains the provisionable traffic parameters for a -- control channel (Sig, Ilmi or Rcc component). atmIfIispSigVcd OBJECT IDENTIFIER ::= { atmIfIispSig 2 } atmIfIispSigVcdRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfIispSigVcd components." ::= { atmIfIispSigVcd 1 } atmIfIispSigVcdRowStatusEntry OBJECT-TYPE SYNTAX AtmIfIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfIispSigVcd component." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex, atmIfIispSigVcdIndex } ::= { atmIfIispSigVcdRowStatusTable 1 } AtmIfIispSigVcdRowStatusEntry ::= SEQUENCE { atmIfIispSigVcdRowStatus RowStatus, atmIfIispSigVcdComponentName DisplayString, atmIfIispSigVcdStorageType StorageType, atmIfIispSigVcdIndex NonReplicated } atmIfIispSigVcdRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfIispSigVcd components. These components can be added and deleted." ::= { atmIfIispSigVcdRowStatusEntry 1 } atmIfIispSigVcdComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfIispSigVcdRowStatusEntry 2 } atmIfIispSigVcdStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfIispSigVcd tables." ::= { atmIfIispSigVcdRowStatusEntry 4 } atmIfIispSigVcdIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfIispSigVcd tables." ::= { atmIfIispSigVcdRowStatusEntry 10 } atmIfIispSigVcdProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable traffic attributes for a control channel." ::= { atmIfIispSigVcd 10 } atmIfIispSigVcdProvEntry OBJECT-TYPE SYNTAX AtmIfIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispSigVcdProvTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex, atmIfIispSigVcdIndex } ::= { atmIfIispSigVcdProvTable 1 } AtmIfIispSigVcdProvEntry ::= SEQUENCE { atmIfIispSigVcdTrafficDescType INTEGER, atmIfIispSigVcdAtmServiceCategory INTEGER, atmIfIispSigVcdQosClass INTEGER, atmIfIispSigVcdTrafficShaping INTEGER, atmIfIispSigVcdUnshapedTransmitQueueing INTEGER, atmIfIispSigVcdUsageParameterControl INTEGER } atmIfIispSigVcdTrafficDescType OBJECT-TYPE SYNTAX INTEGER { n3(3), n6(6), n7(7), n8(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the type of traffic management which is applied to both the transmit and receive direction of this connection as defined in the ATM Forum. The trafficDescType determines the number and meaning of the parameters in the trafficDescParm attribute." DEFVAL { n6 } ::= { atmIfIispSigVcdProvEntry 1 } atmIfIispSigVcdAtmServiceCategory OBJECT-TYPE SYNTAX INTEGER { unspecifiedBitRate(0), constantBitRate(1), rtVariableBitRate(2), nrtVariableBitRate(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the ATM service category for both directions of the connection. The constantBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. The consistent availability of a fixed quantity of bandwidth is considered appropriate for CBR service. Cells which are delayed beyond the value specified by CellTransfer Delay are assumed to be of significantly reduce value to the application. The rtVariableBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. Sources are expected to transmit at a rate which varies with time. Equivalently, the source can be described as 'bursty'. Cells which are delayed beyond the value specified by CTD are assumed to be of significantly reduced value to the application. Real time VBR service may support statistical multiplexing of real time sources. The nrtVariableBitRate service category is intended for non-real time applications which have bursty traffic characteristics and which can be characterized in terms of a PCR, SCR, and MBS. For those cells which are transferred within the traffic contract, the application expects a low cell loss ratio. For all connections, it expects a bound on the mean cell transfer delay. Non-real time VBR service may support statistical multiplexing of connections. The unspecifiedBitRate service is intended for non-real time applications; that is, those not requiring tightly constrained delay and delay variation. UBR sources are expected to be bursty. UBR service supports a high degree of statistical multiplexing among sources. UBR service does not specify traffic related service guarantees. No numerical commitments are made with respect to the cell loss ratio experienced by a UBR connection, or as to the cell transfer delay experienced by cells on the connection." DEFVAL { rtVariableBitRate } ::= { atmIfIispSigVcdProvEntry 3 } atmIfIispSigVcdQosClass OBJECT-TYPE SYNTAX INTEGER { n0(0), n1(1), n2(2), n3(3), n4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the quality of service for both the forward and backward direction for this connection. Class 1 supports a QOS that meets Service Class A performance requirements (Circuit emulation, constant bit rate video). Class 2 supports a QOS that meets Service Class B performance requirements (Variable bit rate audio and video). Class 3 supports a QOS that meets Service Class C performance requirements (Connection-Oriented Data Transfer). Class 4 supports a QOS that meets Service Class D performance requirements (Connectionless Data Transfer). Class 0 is the unspecified bit rate QOS class; no objective is specified for the performance parameters." DEFVAL { n2 } ::= { atmIfIispSigVcdProvEntry 21 } atmIfIispSigVcdTrafficShaping OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection uses traffic shaping when transmitting traffic to the ATM interface. When sameAsCa is selected, traffic shaping for this connection is based on the trafficShaping attribute of the connection's service category component under the AtmIf CA. If the service category has traffic shaping enabled, then traffic shaping is enabled for the connection. Note that enabling traffic shaping may have no effect under certain cases. These cases are listed in the description of the trafficShaping operational attribute, which is under the Vcc Tm and Vpc Tm components. When disabled is selected, traffic shaping for this connection is disabled." DEFVAL { disabled } ::= { atmIfIispSigVcdProvEntry 50 } atmIfIispSigVcdUnshapedTransmitQueueing OBJECT-TYPE SYNTAX INTEGER { common(1), sameAsCa(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute only applies when this connection is unshaped. This attribute specifies the transmit queueing method for this connection if it is unshaped. Refer to the unshapedTransmitQueueing attribute under the AtmIf CA service category subcomponent for more details on the meaning of this attribute. When this attribute is set to sameAsCa, the transmit queueing method for the connection is based on the unshapedTransmitQueueing attribute of the connection's service category component under the ConnectionAdministrator. When this attribute is set to common, transmit traffic on this unshaped connection is destined for the common queue. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { sameAsCa } ::= { atmIfIispSigVcdProvEntry 60 } atmIfIispSigVcdUsageParameterControl OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection enforces usage parameter control when receiving traffic from the ATM interface. When sameAsCa is selected, UPC for the connection is based on the usageParameterControl attribute of the connection's service category component under the ConnectionAdministrator. If the service category has UPC enabled, then UPC is enabled for the connection. Note that enabling UPC may have no effect under certain cases. These cases are listed in the description of the usageParameterControl operational attribute, which is under the Vcc Tm or Vpc Tm component. When disabled is selected, UPC for this connection is disabled. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { disabled } ::= { atmIfIispSigVcdProvEntry 70 } atmIfIispSigVcdTdpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of five traffic parameters whose meanings are defined by the trafficDescType attribute. The values of peak cell rate (PCR), sustained cell rate (SCR) and requested shaping rate are expressed in cell/s. Maximum burst size (MBS) is expressed in cells. CDVT is expressed in microseconds. The values of PCR, SCR, MBS and CDVT are used for connection admission control (CAC). The value of CDVT is only used for connections where the atmServiceCategory is constantBitRate. For all other values of atmServiceCategory, CDVT is ignored. The values of PCR, SCR and requested shaping rate are used to determine the actual shaping rate where traffic shaping is enabled. When trafficDescType is 3, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameter 1 must be non-zero. Parameters 2 and 3 must be zero. When trafficDescType is 6, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 7, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 with cell discard; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 8, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 traffic with cell tagging; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. Whenever it is valid for PCR to be specified, parameter 5 may also be used to specify a requested shaping rate. A non-zero value in parameter 5 overrides the value in parameter 1 and is used as the peak cell rate in calculations of CAC and shaping rate. For trafficDescType 3 the traffic is shaped at the next rate less than the PCR. For trafficDescType 6, 7, and 8, the traffic is shaped at the highest available rate which is between PCR and SCR. However, if there is no available shaping rate between PCR and SCR, traffic is shaped at the next rate above the PCR." ::= { atmIfIispSigVcd 387 } atmIfIispSigVcdTdpEntry OBJECT-TYPE SYNTAX AtmIfIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispSigVcdTdpTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispSigIndex, atmIfIispSigVcdIndex, atmIfIispSigVcdTdpIndex } ::= { atmIfIispSigVcdTdpTable 1 } AtmIfIispSigVcdTdpEntry ::= SEQUENCE { atmIfIispSigVcdTdpIndex Integer32, atmIfIispSigVcdTdpValue Unsigned32 } atmIfIispSigVcdTdpIndex OBJECT-TYPE SYNTAX Integer32 (1..5) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the atmIfIispSigVcdTdpTable specific index for the atmIfIispSigVcdTdpTable." ::= { atmIfIispSigVcdTdpEntry 1 } atmIfIispSigVcdTdpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the atmIfIispSigVcdTdpTable." ::= { atmIfIispSigVcdTdpEntry 2 } -- AtmIf/n Iisp Address/address,type -- AtmIf/n Uni Address/address,type -- AtmIf/n Pnni Address/address,type -- AtmIf/n Vpt/m Iisp Address/address,type -- AtmIf/n Vpt/m Uni Address/address,type -- AtmIf/n Vpt/m Pnni Address/address,type -- -- This component represents an address (dynamic or static) -- associated with the interface. The index is a string of 1 to 40 hex -- digits or a single wildcard ('?'), and a type. The type identifies -- whether the Address component is for a primary, alternate, -- registered, or default address. -- -- The types primary and alternate are used for provisioned addresses. -- The type registered is used for dynamic addresses registered -- through ILMI. The type default is used for Soft PVP and Soft PVC -- addresses.Virtual interfaces do not have addresses of -- type default. -- -- The wildcard is only valid for provisioned addresses. If the address -- is a single wildcard, then that indicates that the interface supports -- all addresses. If there is no better match, then this interface may be -- chosen in the routing. If there is more than one interface with a -- single wildcard static address, then the choice is driven through a -- round robin algorithm. -- -- The round robin algorithm tries the primary routes and then the -- alternate routes if none of the primary routes succeed. -- If this node participates in a PNNI hierarchy, then a PnniInfo -- subcomponent can be provisioned under the AtmAddress -- component to specify the level to which this address will be -- advertised. atmIfIispAddr OBJECT IDENTIFIER ::= { atmIfIisp 4 } atmIfIispAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfIispAddr components." ::= { atmIfIispAddr 1 } atmIfIispAddrRowStatusEntry OBJECT-TYPE SYNTAX AtmIfIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfIispAddr component." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispAddrAddressIndex, atmIfIispAddrAddressTypeIndex } ::= { atmIfIispAddrRowStatusTable 1 } AtmIfIispAddrRowStatusEntry ::= SEQUENCE { atmIfIispAddrRowStatus RowStatus, atmIfIispAddrComponentName DisplayString, atmIfIispAddrStorageType StorageType, atmIfIispAddrAddressIndex AsciiStringIndex, atmIfIispAddrAddressTypeIndex INTEGER } atmIfIispAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfIispAddr components. These components can be added and deleted." ::= { atmIfIispAddrRowStatusEntry 1 } atmIfIispAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfIispAddrRowStatusEntry 2 } atmIfIispAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfIispAddr tables." ::= { atmIfIispAddrRowStatusEntry 4 } atmIfIispAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the atmIfIispAddr tables." ::= { atmIfIispAddrRowStatusEntry 10 } atmIfIispAddrAddressTypeIndex OBJECT-TYPE SYNTAX INTEGER { primary(0), alternate(1), default(3) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the atmIfIispAddr tables." ::= { atmIfIispAddrRowStatusEntry 11 } atmIfIispAddrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the Address component." ::= { atmIfIispAddr 10 } atmIfIispAddrOperEntry OBJECT-TYPE SYNTAX AtmIfIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispAddrOperTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispAddrAddressIndex, atmIfIispAddrAddressTypeIndex } ::= { atmIfIispAddrOperTable 1 } AtmIfIispAddrOperEntry ::= SEQUENCE { atmIfIispAddrScope INTEGER, atmIfIispAddrReachability INTEGER } atmIfIispAddrScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the scope of the ATM address, which is the highest level to which this address will be advertised in the PNNI hierarchy. If no PnniInfo subcomponent has been provisioned, then the scope will default to the level of this node in the PNNI hierarchy. If this node does not participate in a PNNI hierarchy, then this attribute will have the value of -1." ::= { atmIfIispAddrOperEntry 1 } atmIfIispAddrReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." ::= { atmIfIispAddrOperEntry 2 } -- AtmIf/n Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Pnni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Pnni Address/address,type TerminateSPvpAndSPvc -- -- The presence of this subcomponent indicates that SPvp and SPvc -- call setups terminate at this node if the destination address of the -- SPVP or SPVC matches the Address instance. atmIfIispAddrTermSP OBJECT IDENTIFIER ::= { atmIfIispAddr 2 } atmIfIispAddrTermSPRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfIispAddrTermSP components." ::= { atmIfIispAddrTermSP 1 } atmIfIispAddrTermSPRowStatusEntry OBJECT-TYPE SYNTAX AtmIfIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfIispAddrTermSP component." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispAddrAddressIndex, atmIfIispAddrAddressTypeIndex, atmIfIispAddrTermSPIndex } ::= { atmIfIispAddrTermSPRowStatusTable 1 } AtmIfIispAddrTermSPRowStatusEntry ::= SEQUENCE { atmIfIispAddrTermSPRowStatus RowStatus, atmIfIispAddrTermSPComponentName DisplayString, atmIfIispAddrTermSPStorageType StorageType, atmIfIispAddrTermSPIndex NonReplicated } atmIfIispAddrTermSPRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfIispAddrTermSP components. These components can be added and deleted." ::= { atmIfIispAddrTermSPRowStatusEntry 1 } atmIfIispAddrTermSPComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfIispAddrTermSPRowStatusEntry 2 } atmIfIispAddrTermSPStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfIispAddrTermSP tables." ::= { atmIfIispAddrTermSPRowStatusEntry 4 } atmIfIispAddrTermSPIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfIispAddrTermSP tables." ::= { atmIfIispAddrTermSPRowStatusEntry 10 } -- AtmIf/n Iisp Addr/address,type PnniInfo -- AtmIf/n Uni Addr/address,type PnniInfo -- AtmIf/n Pnni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Iisp Addr/address,type PnniInfo -- AtmIf/n Vpt/m Uni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Pnni Addr/address,type PnniInfo -- -- This component contains provisioned information associated with -- the ATM address related to PNNI. This component appears only -- under provisioned Address components. atmIfIispAddrPnniInfo OBJECT IDENTIFIER ::= { atmIfIispAddr 3 } atmIfIispAddrPnniInfoRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfIispAddrPnniInfo components." ::= { atmIfIispAddrPnniInfo 1 } atmIfIispAddrPnniInfoRowStatusEntry OBJECT-TYPE SYNTAX AtmIfIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfIispAddrPnniInfo component." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispAddrAddressIndex, atmIfIispAddrAddressTypeIndex, atmIfIispAddrPnniInfoIndex } ::= { atmIfIispAddrPnniInfoRowStatusTable 1 } AtmIfIispAddrPnniInfoRowStatusEntry ::= SEQUENCE { atmIfIispAddrPnniInfoRowStatus RowStatus, atmIfIispAddrPnniInfoComponentName DisplayString, atmIfIispAddrPnniInfoStorageType StorageType, atmIfIispAddrPnniInfoIndex NonReplicated } atmIfIispAddrPnniInfoRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfIispAddrPnniInfo components. These components can be added and deleted." ::= { atmIfIispAddrPnniInfoRowStatusEntry 1 } atmIfIispAddrPnniInfoComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfIispAddrPnniInfoRowStatusEntry 2 } atmIfIispAddrPnniInfoStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfIispAddrPnniInfo tables." ::= { atmIfIispAddrPnniInfoRowStatusEntry 4 } atmIfIispAddrPnniInfoIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfIispAddrPnniInfo tables." ::= { atmIfIispAddrPnniInfoRowStatusEntry 10 } atmIfIispAddrPnniInfoProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisioned attributes relating to PNNI for a PnniInfo component." ::= { atmIfIispAddrPnniInfo 10 } atmIfIispAddrPnniInfoProvEntry OBJECT-TYPE SYNTAX AtmIfIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfIispAddrPnniInfoProvTable." INDEX { atmIfIndex, atmIfIispIndex, atmIfIispAddrAddressIndex, atmIfIispAddrAddressTypeIndex, atmIfIispAddrPnniInfoIndex } ::= { atmIfIispAddrPnniInfoProvTable 1 } AtmIfIispAddrPnniInfoProvEntry ::= SEQUENCE { atmIfIispAddrPnniInfoScope INTEGER, atmIfIispAddrPnniInfoReachability INTEGER } atmIfIispAddrPnniInfoScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the scope of the ATM address, which is the highest level up to which this address will be advertised in the PNNI hierarchy. The scope must be set to a value numerically less than or equal to the level of the lowest level peer group containing this node. Setting the scope to 0 will cause the address to be advertised globally within this PNNI routing domain." DEFVAL { -1 } ::= { atmIfIispAddrPnniInfoProvEntry 1 } atmIfIispAddrPnniInfoReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." DEFVAL { internal } ::= { atmIfIispAddrPnniInfoProvEntry 2 } -- AtmIf/n VirtualPathTerminator/m Iisp -- This component represents a virtual ATM Interim Inter-switch -- Signaling Protocol (IISP) interface. If this component is -- provisioned, neither a Uni component nor a Pnni component can be -- provisioned under the same Vpt component. If this component is -- deleted, then all associated Vcc components are deleted. atmIfVptIisp OBJECT IDENTIFIER ::= { atmIfVpt 6 } atmIfVptIispRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfVptIisp components." ::= { atmIfVptIisp 1 } atmIfVptIispRowStatusEntry OBJECT-TYPE SYNTAX AtmIfVptIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfVptIisp component." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex } ::= { atmIfVptIispRowStatusTable 1 } AtmIfVptIispRowStatusEntry ::= SEQUENCE { atmIfVptIispRowStatus RowStatus, atmIfVptIispComponentName DisplayString, atmIfVptIispStorageType StorageType, atmIfVptIispIndex NonReplicated } atmIfVptIispRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfVptIisp components. These components can be added and deleted." ::= { atmIfVptIispRowStatusEntry 1 } atmIfVptIispComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfVptIispRowStatusEntry 2 } atmIfVptIispStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfVptIisp tables." ::= { atmIfVptIispRowStatusEntry 4 } atmIfVptIispIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfVptIisp tables." ::= { atmIfVptIispRowStatusEntry 10 } atmIfVptIispProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the Iisp component." ::= { atmIfVptIisp 10 } atmIfVptIispProvEntry OBJECT-TYPE SYNTAX AtmIfVptIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispProvTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex } ::= { atmIfVptIispProvTable 1 } AtmIfVptIispProvEntry ::= SEQUENCE { atmIfVptIispVersion INTEGER, atmIfVptIispSide INTEGER, atmIfVptIispSoftPvcRetryPeriod Unsigned32, atmIfVptIispSoftPvpAndPvcRetryPeriod Unsigned32, atmIfVptIispSoftPvpAndPvcHoldOffTime Unsigned32 } atmIfVptIispVersion OBJECT-TYPE SYNTAX INTEGER { iisp10Sig30(2), iisp10Sig31(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which specification the IISP interface complies with. The options are iisp10Sig30 which refers to IISP version 1.0 with 3.0 signalling and iisp10Sig31 which refers to IISP version 1.0 with 3.1 signalling. If this attribute is changed, all switched Vcc components in this interface are cleared due to the fact that the two versions are incompatible." DEFVAL { iisp10Sig31 } ::= { atmIfVptIispProvEntry 1 } atmIfVptIispSide OBJECT-TYPE SYNTAX INTEGER { networkSide(0), userSide(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which side the interface is, user or network." DEFVAL { networkSide } ::= { atmIfVptIispProvEntry 2 } atmIfVptIispSoftPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute specifies the time to wait between call set up retries. The resolution is to the nearest 10 seconds. This attribute has been obsoleted and is replaced by the softPvpAndPvcRetryPeriod attribute." DEFVAL { 60 } ::= { atmIfVptIispProvEntry 3 } atmIfVptIispSoftPvpAndPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the time to wait between soft PVP or soft PVC call setup retries. The resolution is to the nearest 10 seconds." DEFVAL { 60 } ::= { atmIfVptIispProvEntry 4 } atmIfVptIispSoftPvpAndPvcHoldOffTime OBJECT-TYPE SYNTAX Unsigned32 (0 | 50..20000) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies how long to hold off retries following a release or the connection. The resolution is to the nearest 50 ms." DEFVAL { 0 } ::= { atmIfVptIispProvEntry 5 } atmIfVptIispAcctOptTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for accounting." ::= { atmIfVptIisp 11 } atmIfVptIispAcctOptEntry OBJECT-TYPE SYNTAX AtmIfVptIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispAcctOptTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex } ::= { atmIfVptIispAcctOptTable 1 } AtmIfVptIispAcctOptEntry ::= SEQUENCE { atmIfVptIispAccountCollection OCTET STRING, atmIfVptIispAccountConnectionType INTEGER, atmIfVptIispAccountClass Unsigned32, atmIfVptIispServiceExchange Unsigned32 } atmIfVptIispAccountCollection OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to turn accounting on or off for SVC and SPVC connections. It also specifies the reason(s) for which accounting data is collected: billing, test, study, audit, or force. If the set of reasons is not empty then accounting records will be generated by this interface in the following situations: - on a TODA changeover if TODA is enabled; - every 12 hours (per connection) if TODA is disabled; - on every call clear (a call record with final cell counts). If none of the reasons is present, then accounting will be suppressed. The reason for collection is recorded in the accounting record, in the attribute callingCollectReason or calledCollectReason as appropriate. Description of bits: bill(0) test(1) study(2) audit(3) force(4)" ::= { atmIfVptIispAcctOptEntry 1 } atmIfVptIispAccountConnectionType OBJECT-TYPE SYNTAX INTEGER { origTerm(0), intermediate(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether accounting records generated by this interface should be marked as originating, terminating or intermediate. This attribute, in combination with the direction of the call, determines the value of attribute connPointType of the accounting record and may be used by downstream accounting processes to correlate the records. If the value is origTerm then records generated for incoming calls will be marked as originating and records generated for outgoing calls will be marked as terminating. If the value is intermediate then records generated for all calls will be marked as intermediate." DEFVAL { intermediate } ::= { atmIfVptIispAcctOptEntry 2 } atmIfVptIispAccountClass OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the accounting class associated with the interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingServiceType or calledServiceType as appropriate." DEFVAL { 0 } ::= { atmIfVptIispAcctOptEntry 3 } atmIfVptIispServiceExchange OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the data service exchange associated with this interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingDse or calledDse as appropriate." DEFVAL { 0 } ::= { atmIfVptIispAcctOptEntry 4 } atmIfVptIispVProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispVProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the Iisp component which are specific to virtual IISP interfaces." ::= { atmIfVptIisp 12 } atmIfVptIispVProvEntry OBJECT-TYPE SYNTAX AtmIfVptIispVProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispVProvTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex } ::= { atmIfVptIispVProvTable 1 } AtmIfVptIispVProvEntry ::= SEQUENCE { atmIfVptIispVpci Unsigned32 } atmIfVptIispVpci OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the Virtual Path Connection Identifier (VPCI) to be used between this signalling entity and its peer. The VPCI of the peer virtual IISP must have the same value for switched connections to be set up across the interface." DEFVAL { 0 } ::= { atmIfVptIispVProvEntry 1 } -- AtmIf/n Iisp Signalling -- AtmIf/n Uni Signalling -- AtmIf/n Pnni Signalling -- AtmIf/n Vpt/m Iisp Signalling -- AtmIf/n Vpt/m Uni Signalling -- AtmIf/n Vpt/m Pnni Signalling -- -- This component represents the signalling entities for the interface. atmIfVptIispSig OBJECT IDENTIFIER ::= { atmIfVptIisp 3 } atmIfVptIispSigRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfVptIispSig components." ::= { atmIfVptIispSig 1 } atmIfVptIispSigRowStatusEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfVptIispSig component." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex } ::= { atmIfVptIispSigRowStatusTable 1 } AtmIfVptIispSigRowStatusEntry ::= SEQUENCE { atmIfVptIispSigRowStatus RowStatus, atmIfVptIispSigComponentName DisplayString, atmIfVptIispSigStorageType StorageType, atmIfVptIispSigIndex NonReplicated } atmIfVptIispSigRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfVptIispSig components. These components cannot be added nor deleted." ::= { atmIfVptIispSigRowStatusEntry 1 } atmIfVptIispSigComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfVptIispSigRowStatusEntry 2 } atmIfVptIispSigStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfVptIispSig tables." ::= { atmIfVptIispSigRowStatusEntry 4 } atmIfVptIispSigIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfVptIispSig tables." ::= { atmIfVptIispSigRowStatusEntry 10 } atmIfVptIispSigProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the Signalling component." ::= { atmIfVptIispSig 10 } atmIfVptIispSigProvEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispSigProvTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex } ::= { atmIfVptIispSigProvTable 1 } AtmIfVptIispSigProvEntry ::= SEQUENCE { atmIfVptIispSigVci Unsigned32, atmIfVptIispSigAddressConversion INTEGER } atmIfVptIispSigVci OBJECT-TYPE SYNTAX Unsigned32 (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the signalling channel number." DEFVAL { 5 } ::= { atmIfVptIispSigProvEntry 1 } atmIfVptIispSigAddressConversion OBJECT-TYPE SYNTAX INTEGER { none(0), nativeE164(1), nsap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the address conversion on the outgoing signalling PDUs. The options are none, nativeE164, or nsap. The none option is the default and if this option is chosen then nothing is done to the address information element (IE) in the outgoing signalling message. If nativeE164 option is chosen, then only NSAP encapsulated E.164 addresses with zeros in the ESI are converted to native E.164 format in the outgoing signalling message. If the NSAP address is not encapsulated E.164 or the ESI field is not zeros and the nativeE164 option is chosen, then the call is cleared. If the nsap option is chosen, then native E.164 addresses are converted to NSAP E.164 with zeros in the ESI field; otherwise the address is in NSAP format and is not changed." DEFVAL { none } ::= { atmIfVptIispSigProvEntry 2 } atmIfVptIispSigStateTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { atmIfVptIispSig 11 } atmIfVptIispSigStateEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispSigStateTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex } ::= { atmIfVptIispSigStateTable 1 } AtmIfVptIispSigStateEntry ::= SEQUENCE { atmIfVptIispSigAdminState INTEGER, atmIfVptIispSigOperationalState INTEGER, atmIfVptIispSigUsageState INTEGER } atmIfVptIispSigAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { atmIfVptIispSigStateEntry 1 } atmIfVptIispSigOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { atmIfVptIispSigStateEntry 2 } atmIfVptIispSigUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { atmIfVptIispSigStateEntry 3 } atmIfVptIispSigOperTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute contains the operational attributes for the AtmSignalling component." ::= { atmIfVptIispSig 12 } atmIfVptIispSigOperEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispSigOperTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex } ::= { atmIfVptIispSigOperTable 1 } AtmIfVptIispSigOperEntry ::= SEQUENCE { atmIfVptIispSigLastTxCauseCode Unsigned32, atmIfVptIispSigLastTxDiagCode Hex, atmIfVptIispSigLastRxCauseCode Unsigned32, atmIfVptIispSigLastRxDiagCode Hex } atmIfVptIispSigLastTxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the cause code in the last transmitted signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { atmIfVptIispSigOperEntry 1 } atmIfVptIispSigLastTxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last transmitted signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { atmIfVptIispSigOperEntry 2 } atmIfVptIispSigLastRxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the cause code in the last received signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { atmIfVptIispSigOperEntry 3 } atmIfVptIispSigLastRxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last received signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { atmIfVptIispSigOperEntry 4 } atmIfVptIispSigStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the statistics associated with the AtmSignalling component." ::= { atmIfVptIispSig 13 } atmIfVptIispSigStatsEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispSigStatsTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex } ::= { atmIfVptIispSigStatsTable 1 } AtmIfVptIispSigStatsEntry ::= SEQUENCE { atmIfVptIispSigCurrentConnections Counter32, atmIfVptIispSigPeakConnections Gauge32, atmIfVptIispSigSuccessfulConnections Counter32, atmIfVptIispSigFailedConnections Counter32, atmIfVptIispSigTxPdus Counter32, atmIfVptIispSigRxPdus Counter32, atmIfVptIispSigCurrentPmpConnections Gauge32, atmIfVptIispSigPeakPmpConnections Gauge32, atmIfVptIispSigSuccessfulPmpConnections Counter32, atmIfVptIispSigFailedPmpConnections Counter32, atmIfVptIispSigNewCurrentConnections Gauge32 } atmIfVptIispSigCurrentConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "This attribute indicates the total number of currently active connections." ::= { atmIfVptIispSigStatsEntry 1 } atmIfVptIispSigPeakConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- point and point-to-multipoint connections." ::= { atmIfVptIispSigStatsEntry 2 } atmIfVptIispSigSuccessfulConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- point and point-to-multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfVptIispSigStatsEntry 3 } atmIfVptIispSigFailedConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfVptIispSigStatsEntry 4 } atmIfVptIispSigTxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of transmitted signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfVptIispSigStatsEntry 5 } atmIfVptIispSigRxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of received signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfVptIispSigStatsEntry 6 } atmIfVptIispSigCurrentPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of currently active point-to- multipoint connections." ::= { atmIfVptIispSigStatsEntry 7 } atmIfVptIispSigPeakPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- multipoint connections." ::= { atmIfVptIispSigStatsEntry 8 } atmIfVptIispSigSuccessfulPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfVptIispSigStatsEntry 9 } atmIfVptIispSigFailedPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of switched point-to- multipoint connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { atmIfVptIispSigStatsEntry 10 } atmIfVptIispSigNewCurrentConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the total number of currently active point-to- point and point-to-multipoint connections." ::= { atmIfVptIispSigStatsEntry 11 } -- AtmIf/n Uni Sig VirtualChannelDescriptor -- AtmIf/n Uni Ilmi VirtualChannelDescriptor -- AtmIf/n Iisp Sig VirtualChannelDescriptor -- AtmIf/n Pnni Sig VirtualChannelDescriptor -- AtmIf/n Pnni Rcc VirtualChannelDescriptor -- AtmIf/n Vpt/m Uni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Iisp Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Rcc VirtualChannelDescriptor -- -- This component contains the provisionable traffic parameters for a -- control channel (Sig, Ilmi or Rcc component). atmIfVptIispSigVcd OBJECT IDENTIFIER ::= { atmIfVptIispSig 2 } atmIfVptIispSigVcdRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfVptIispSigVcd components." ::= { atmIfVptIispSigVcd 1 } atmIfVptIispSigVcdRowStatusEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfVptIispSigVcd component." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex, atmIfVptIispSigVcdIndex } ::= { atmIfVptIispSigVcdRowStatusTable 1 } AtmIfVptIispSigVcdRowStatusEntry ::= SEQUENCE { atmIfVptIispSigVcdRowStatus RowStatus, atmIfVptIispSigVcdComponentName DisplayString, atmIfVptIispSigVcdStorageType StorageType, atmIfVptIispSigVcdIndex NonReplicated } atmIfVptIispSigVcdRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfVptIispSigVcd components. These components can be added and deleted." ::= { atmIfVptIispSigVcdRowStatusEntry 1 } atmIfVptIispSigVcdComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfVptIispSigVcdRowStatusEntry 2 } atmIfVptIispSigVcdStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfVptIispSigVcd tables." ::= { atmIfVptIispSigVcdRowStatusEntry 4 } atmIfVptIispSigVcdIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfVptIispSigVcd tables." ::= { atmIfVptIispSigVcdRowStatusEntry 10 } atmIfVptIispSigVcdProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable traffic attributes for a control channel." ::= { atmIfVptIispSigVcd 10 } atmIfVptIispSigVcdProvEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispSigVcdProvTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex, atmIfVptIispSigVcdIndex } ::= { atmIfVptIispSigVcdProvTable 1 } AtmIfVptIispSigVcdProvEntry ::= SEQUENCE { atmIfVptIispSigVcdTrafficDescType INTEGER, atmIfVptIispSigVcdAtmServiceCategory INTEGER, atmIfVptIispSigVcdQosClass INTEGER, atmIfVptIispSigVcdTrafficShaping INTEGER, atmIfVptIispSigVcdUnshapedTransmitQueueing INTEGER, atmIfVptIispSigVcdUsageParameterControl INTEGER } atmIfVptIispSigVcdTrafficDescType OBJECT-TYPE SYNTAX INTEGER { n3(3), n6(6), n7(7), n8(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the type of traffic management which is applied to both the transmit and receive direction of this connection as defined in the ATM Forum. The trafficDescType determines the number and meaning of the parameters in the trafficDescParm attribute." DEFVAL { n6 } ::= { atmIfVptIispSigVcdProvEntry 1 } atmIfVptIispSigVcdAtmServiceCategory OBJECT-TYPE SYNTAX INTEGER { unspecifiedBitRate(0), constantBitRate(1), rtVariableBitRate(2), nrtVariableBitRate(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the ATM service category for both directions of the connection. The constantBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. The consistent availability of a fixed quantity of bandwidth is considered appropriate for CBR service. Cells which are delayed beyond the value specified by CellTransfer Delay are assumed to be of significantly reduce value to the application. The rtVariableBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. Sources are expected to transmit at a rate which varies with time. Equivalently, the source can be described as 'bursty'. Cells which are delayed beyond the value specified by CTD are assumed to be of significantly reduced value to the application. Real time VBR service may support statistical multiplexing of real time sources. The nrtVariableBitRate service category is intended for non-real time applications which have bursty traffic characteristics and which can be characterized in terms of a PCR, SCR, and MBS. For those cells which are transferred within the traffic contract, the application expects a low cell loss ratio. For all connections, it expects a bound on the mean cell transfer delay. Non-real time VBR service may support statistical multiplexing of connections. The unspecifiedBitRate service is intended for non-real time applications; that is, those not requiring tightly constrained delay and delay variation. UBR sources are expected to be bursty. UBR service supports a high degree of statistical multiplexing among sources. UBR service does not specify traffic related service guarantees. No numerical commitments are made with respect to the cell loss ratio experienced by a UBR connection, or as to the cell transfer delay experienced by cells on the connection." DEFVAL { rtVariableBitRate } ::= { atmIfVptIispSigVcdProvEntry 3 } atmIfVptIispSigVcdQosClass OBJECT-TYPE SYNTAX INTEGER { n0(0), n1(1), n2(2), n3(3), n4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the quality of service for both the forward and backward direction for this connection. Class 1 supports a QOS that meets Service Class A performance requirements (Circuit emulation, constant bit rate video). Class 2 supports a QOS that meets Service Class B performance requirements (Variable bit rate audio and video). Class 3 supports a QOS that meets Service Class C performance requirements (Connection-Oriented Data Transfer). Class 4 supports a QOS that meets Service Class D performance requirements (Connectionless Data Transfer). Class 0 is the unspecified bit rate QOS class; no objective is specified for the performance parameters." DEFVAL { n2 } ::= { atmIfVptIispSigVcdProvEntry 21 } atmIfVptIispSigVcdTrafficShaping OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection uses traffic shaping when transmitting traffic to the ATM interface. When sameAsCa is selected, traffic shaping for this connection is based on the trafficShaping attribute of the connection's service category component under the AtmIf CA. If the service category has traffic shaping enabled, then traffic shaping is enabled for the connection. Note that enabling traffic shaping may have no effect under certain cases. These cases are listed in the description of the trafficShaping operational attribute, which is under the Vcc Tm and Vpc Tm components. When disabled is selected, traffic shaping for this connection is disabled." DEFVAL { disabled } ::= { atmIfVptIispSigVcdProvEntry 50 } atmIfVptIispSigVcdUnshapedTransmitQueueing OBJECT-TYPE SYNTAX INTEGER { common(1), sameAsCa(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute only applies when this connection is unshaped. This attribute specifies the transmit queueing method for this connection if it is unshaped. Refer to the unshapedTransmitQueueing attribute under the AtmIf CA service category subcomponent for more details on the meaning of this attribute. When this attribute is set to sameAsCa, the transmit queueing method for the connection is based on the unshapedTransmitQueueing attribute of the connection's service category component under the ConnectionAdministrator. When this attribute is set to common, transmit traffic on this unshaped connection is destined for the common queue. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { sameAsCa } ::= { atmIfVptIispSigVcdProvEntry 60 } atmIfVptIispSigVcdUsageParameterControl OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection enforces usage parameter control when receiving traffic from the ATM interface. When sameAsCa is selected, UPC for the connection is based on the usageParameterControl attribute of the connection's service category component under the ConnectionAdministrator. If the service category has UPC enabled, then UPC is enabled for the connection. Note that enabling UPC may have no effect under certain cases. These cases are listed in the description of the usageParameterControl operational attribute, which is under the Vcc Tm or Vpc Tm component. When disabled is selected, UPC for this connection is disabled. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { disabled } ::= { atmIfVptIispSigVcdProvEntry 70 } atmIfVptIispSigVcdTdpTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of five traffic parameters whose meanings are defined by the trafficDescType attribute. The values of peak cell rate (PCR), sustained cell rate (SCR) and requested shaping rate are expressed in cell/s. Maximum burst size (MBS) is expressed in cells. CDVT is expressed in microseconds. The values of PCR, SCR, MBS and CDVT are used for connection admission control (CAC). The value of CDVT is only used for connections where the atmServiceCategory is constantBitRate. For all other values of atmServiceCategory, CDVT is ignored. The values of PCR, SCR and requested shaping rate are used to determine the actual shaping rate where traffic shaping is enabled. When trafficDescType is 3, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameter 1 must be non-zero. Parameters 2 and 3 must be zero. When trafficDescType is 6, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 7, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 with cell discard; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 8, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 traffic with cell tagging; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. Whenever it is valid for PCR to be specified, parameter 5 may also be used to specify a requested shaping rate. A non-zero value in parameter 5 overrides the value in parameter 1 and is used as the peak cell rate in calculations of CAC and shaping rate. For trafficDescType 3 the traffic is shaped at the next rate less than the PCR. For trafficDescType 6, 7, and 8, the traffic is shaped at the highest available rate which is between PCR and SCR. However, if there is no available shaping rate between PCR and SCR, traffic is shaped at the next rate above the PCR." ::= { atmIfVptIispSigVcd 387 } atmIfVptIispSigVcdTdpEntry OBJECT-TYPE SYNTAX AtmIfVptIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispSigVcdTdpTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispSigIndex, atmIfVptIispSigVcdIndex, atmIfVptIispSigVcdTdpIndex } ::= { atmIfVptIispSigVcdTdpTable 1 } AtmIfVptIispSigVcdTdpEntry ::= SEQUENCE { atmIfVptIispSigVcdTdpIndex Integer32, atmIfVptIispSigVcdTdpValue Unsigned32 } atmIfVptIispSigVcdTdpIndex OBJECT-TYPE SYNTAX Integer32 (1..5) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the atmIfVptIispSigVcdTdpTable specific index for the atmIfVptIispSigVcdTdpTable." ::= { atmIfVptIispSigVcdTdpEntry 1 } atmIfVptIispSigVcdTdpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the atmIfVptIispSigVcdTdpTable." ::= { atmIfVptIispSigVcdTdpEntry 2 } -- AtmIf/n Iisp Address/address,type -- AtmIf/n Uni Address/address,type -- AtmIf/n Pnni Address/address,type -- AtmIf/n Vpt/m Iisp Address/address,type -- AtmIf/n Vpt/m Uni Address/address,type -- AtmIf/n Vpt/m Pnni Address/address,type -- -- This component represents an address (dynamic or static) -- associated with the interface. The index is a string of 1 to 40 hex -- digits or a single wildcard ('?'), and a type. The type identifies -- whether the Address component is for a primary, alternate, -- registered, or default address. -- -- The types primary and alternate are used for provisioned addresses. -- The type registered is used for dynamic addresses registered -- through ILMI. The type default is used for Soft PVP and Soft PVC -- addresses.Virtual interfaces do not have addresses of -- type default. -- -- The wildcard is only valid for provisioned addresses. If the address -- is a single wildcard, then that indicates that the interface supports -- all addresses. If there is no better match, then this interface may be -- chosen in the routing. If there is more than one interface with a -- single wildcard static address, then the choice is driven through a -- round robin algorithm. -- -- The round robin algorithm tries the primary routes and then the -- alternate routes if none of the primary routes succeed. -- If this node participates in a PNNI hierarchy, then a PnniInfo -- subcomponent can be provisioned under the AtmAddress -- component to specify the level to which this address will be -- advertised. atmIfVptIispAddr OBJECT IDENTIFIER ::= { atmIfVptIisp 4 } atmIfVptIispAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfVptIispAddr components." ::= { atmIfVptIispAddr 1 } atmIfVptIispAddrRowStatusEntry OBJECT-TYPE SYNTAX AtmIfVptIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfVptIispAddr component." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispAddrAddressIndex, atmIfVptIispAddrAddressTypeIndex } ::= { atmIfVptIispAddrRowStatusTable 1 } AtmIfVptIispAddrRowStatusEntry ::= SEQUENCE { atmIfVptIispAddrRowStatus RowStatus, atmIfVptIispAddrComponentName DisplayString, atmIfVptIispAddrStorageType StorageType, atmIfVptIispAddrAddressIndex AsciiStringIndex, atmIfVptIispAddrAddressTypeIndex INTEGER } atmIfVptIispAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfVptIispAddr components. These components can be added and deleted." ::= { atmIfVptIispAddrRowStatusEntry 1 } atmIfVptIispAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfVptIispAddrRowStatusEntry 2 } atmIfVptIispAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfVptIispAddr tables." ::= { atmIfVptIispAddrRowStatusEntry 4 } atmIfVptIispAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the atmIfVptIispAddr tables." ::= { atmIfVptIispAddrRowStatusEntry 10 } atmIfVptIispAddrAddressTypeIndex OBJECT-TYPE SYNTAX INTEGER { primary(0), alternate(1), default(3) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the atmIfVptIispAddr tables." ::= { atmIfVptIispAddrRowStatusEntry 11 } atmIfVptIispAddrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the Address component." ::= { atmIfVptIispAddr 10 } atmIfVptIispAddrOperEntry OBJECT-TYPE SYNTAX AtmIfVptIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispAddrOperTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispAddrAddressIndex, atmIfVptIispAddrAddressTypeIndex } ::= { atmIfVptIispAddrOperTable 1 } AtmIfVptIispAddrOperEntry ::= SEQUENCE { atmIfVptIispAddrScope INTEGER, atmIfVptIispAddrReachability INTEGER } atmIfVptIispAddrScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the scope of the ATM address, which is the highest level to which this address will be advertised in the PNNI hierarchy. If no PnniInfo subcomponent has been provisioned, then the scope will default to the level of this node in the PNNI hierarchy. If this node does not participate in a PNNI hierarchy, then this attribute will have the value of -1." ::= { atmIfVptIispAddrOperEntry 1 } atmIfVptIispAddrReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." ::= { atmIfVptIispAddrOperEntry 2 } -- AtmIf/n Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Pnni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Pnni Address/address,type TerminateSPvpAndSPvc -- -- The presence of this subcomponent indicates that SPvp and SPvc -- call setups terminate at this node if the destination address of the -- SPVP or SPVC matches the Address instance. atmIfVptIispAddrTermSP OBJECT IDENTIFIER ::= { atmIfVptIispAddr 2 } atmIfVptIispAddrTermSPRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfVptIispAddrTermSP components." ::= { atmIfVptIispAddrTermSP 1 } atmIfVptIispAddrTermSPRowStatusEntry OBJECT-TYPE SYNTAX AtmIfVptIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfVptIispAddrTermSP component." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispAddrAddressIndex, atmIfVptIispAddrAddressTypeIndex, atmIfVptIispAddrTermSPIndex } ::= { atmIfVptIispAddrTermSPRowStatusTable 1 } AtmIfVptIispAddrTermSPRowStatusEntry ::= SEQUENCE { atmIfVptIispAddrTermSPRowStatus RowStatus, atmIfVptIispAddrTermSPComponentName DisplayString, atmIfVptIispAddrTermSPStorageType StorageType, atmIfVptIispAddrTermSPIndex NonReplicated } atmIfVptIispAddrTermSPRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfVptIispAddrTermSP components. These components can be added and deleted." ::= { atmIfVptIispAddrTermSPRowStatusEntry 1 } atmIfVptIispAddrTermSPComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfVptIispAddrTermSPRowStatusEntry 2 } atmIfVptIispAddrTermSPStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfVptIispAddrTermSP tables." ::= { atmIfVptIispAddrTermSPRowStatusEntry 4 } atmIfVptIispAddrTermSPIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfVptIispAddrTermSP tables." ::= { atmIfVptIispAddrTermSPRowStatusEntry 10 } -- AtmIf/n Iisp Addr/address,type PnniInfo -- AtmIf/n Uni Addr/address,type PnniInfo -- AtmIf/n Pnni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Iisp Addr/address,type PnniInfo -- AtmIf/n Vpt/m Uni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Pnni Addr/address,type PnniInfo -- -- This component contains provisioned information associated with -- the ATM address related to PNNI. This component appears only -- under provisioned Address components. atmIfVptIispAddrPnniInfo OBJECT IDENTIFIER ::= { atmIfVptIispAddr 3 } atmIfVptIispAddrPnniInfoRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of atmIfVptIispAddrPnniInfo components." ::= { atmIfVptIispAddrPnniInfo 1 } atmIfVptIispAddrPnniInfoRowStatusEntry OBJECT-TYPE SYNTAX AtmIfVptIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single atmIfVptIispAddrPnniInfo component." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispAddrAddressIndex, atmIfVptIispAddrAddressTypeIndex, atmIfVptIispAddrPnniInfoIndex } ::= { atmIfVptIispAddrPnniInfoRowStatusTable 1 } AtmIfVptIispAddrPnniInfoRowStatusEntry ::= SEQUENCE { atmIfVptIispAddrPnniInfoRowStatus RowStatus, atmIfVptIispAddrPnniInfoComponentName DisplayString, atmIfVptIispAddrPnniInfoStorageType StorageType, atmIfVptIispAddrPnniInfoIndex NonReplicated } atmIfVptIispAddrPnniInfoRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of atmIfVptIispAddrPnniInfo components. These components can be added and deleted." ::= { atmIfVptIispAddrPnniInfoRowStatusEntry 1 } atmIfVptIispAddrPnniInfoComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { atmIfVptIispAddrPnniInfoRowStatusEntry 2 } atmIfVptIispAddrPnniInfoStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the atmIfVptIispAddrPnniInfo tables." ::= { atmIfVptIispAddrPnniInfoRowStatusEntry 4 } atmIfVptIispAddrPnniInfoIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the atmIfVptIispAddrPnniInfo tables." ::= { atmIfVptIispAddrPnniInfoRowStatusEntry 10 } atmIfVptIispAddrPnniInfoProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmIfVptIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisioned attributes relating to PNNI for a PnniInfo component." ::= { atmIfVptIispAddrPnniInfo 10 } atmIfVptIispAddrPnniInfoProvEntry OBJECT-TYPE SYNTAX AtmIfVptIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the atmIfVptIispAddrPnniInfoProvTable." INDEX { atmIfIndex, atmIfVptIndex, atmIfVptIispIndex, atmIfVptIispAddrAddressIndex, atmIfVptIispAddrAddressTypeIndex, atmIfVptIispAddrPnniInfoIndex } ::= { atmIfVptIispAddrPnniInfoProvTable 1 } AtmIfVptIispAddrPnniInfoProvEntry ::= SEQUENCE { atmIfVptIispAddrPnniInfoScope INTEGER, atmIfVptIispAddrPnniInfoReachability INTEGER } atmIfVptIispAddrPnniInfoScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the scope of the ATM address, which is the highest level up to which this address will be advertised in the PNNI hierarchy. The scope must be set to a value numerically less than or equal to the level of the lowest level peer group containing this node. Setting the scope to 0 will cause the address to be advertised globally within this PNNI routing domain." DEFVAL { -1 } ::= { atmIfVptIispAddrPnniInfoProvEntry 1 } atmIfVptIispAddrPnniInfoReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." DEFVAL { internal } ::= { atmIfVptIispAddrPnniInfoProvEntry 2 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { atmIfIispAccountConnectionType, -- atmIfIispAddrPnniInfoStorageType, -- atmIfIispSigFailedPmpConnections, -- atmIfVptIispSigTxPdus, -- atmIfVptIispSigFailedConnections, -- atmIfVptIispAddrScope, -- atmIfVptIispSigUsageState, -- atmIfIispSigAddressConversion, -- atmIfVptIispSigVcdQosClass, -- atmIfIispAddrPnniInfoReachability, -- atmIfIispAddrTermSPRowStatus, -- atmIfIispSigComponentName, -- atmIfIispSigVcdRowStatus, -- atmIfVptIispAddrPnniInfoReachability, -- atmIfVptIispSigCurrentPmpConnections, -- atmIfIispAddrTermSPStorageType, -- atmIfVptIispSigVcdComponentName, -- atmIfIispAddrPnniInfoRowStatus, -- atmIfVptIispSigVcdUsageParameterControl, -- atmIfVptIispSoftPvpAndPvcRetryPeriod, -- atmIfVptIispAddrPnniInfoComponentName, -- atmIfIispAccountCollection, -- atmIfVptIispSigRxPdus, -- atmIfIispVersion, -- atmIfIispAddrStorageType, -- atmIfIispStorageType, -- atmIfVptIispSigLastTxDiagCode, -- atmIfVptIispSigLastRxDiagCode, -- atmIfVptIispSigLastTxCauseCode, -- atmIfVptIispSigPeakPmpConnections, -- atmIfIispSigSuccessfulPmpConnections, -- atmIfIispAddrReachability, -- atmIfVptIispAddrPnniInfoStorageType, -- atmIfVptIispSigSuccessfulConnections, -- atmIfVptIispSigNewCurrentConnections, -- atmIfIispAddrRowStatus, -- atmIfIispRowStatus, -- atmIfIispSigStorageType, -- atmIfVptIispSide, -- atmIfVptIispSigAddressConversion, -- atmIfVptIispComponentName, -- atmIfVptIispAccountClass, -- atmIfVptIispSigVcdTrafficShaping, -- atmIfVptIispSigLastRxCauseCode, -- atmIfVptIispVpci, -- atmIfVptIispSigVcdStorageType, -- atmIfIispAddrPnniInfoScope, -- atmIfIispSigVcdUnshapedTransmitQueueing, -- atmIfVptIispAccountConnectionType, -- atmIfVptIispSigVcdTdpValue, -- atmIfIispSigAdminState, -- atmIfVptIispSigFailedPmpConnections, -- atmIfIispSigRowStatus, -- atmIfIispServiceExchange, -- atmIfIispSigPeakConnections, -- atmIfVptIispSigVci, -- atmIfIispSigTxPdus, -- atmIfVptIispAddrComponentName, -- atmIfVptIispSigVcdUnshapedTransmitQueueing, -- atmIfVptIispAddrTermSPRowStatus, -- atmIfVptIispSigComponentName, -- atmIfVptIispSigVcdRowStatus, -- atmIfIispSigRxPdus, -- atmIfIispSigUsageState, -- atmIfVptIispAddrPnniInfoRowStatus, -- atmIfIispSoftPvpAndPvcHoldOffTime, -- atmIfIispSigFailedConnections, -- atmIfIispAddrScope, -- atmIfIispSigVcdUsageParameterControl, -- atmIfIispSigVcdQosClass, -- atmIfIispSigVcdAtmServiceCategory, -- atmIfIispSigLastTxDiagCode, -- atmIfIispSoftPvpAndPvcRetryPeriod, -- atmIfIispSigOperationalState, -- atmIfVptIispAddrStorageType, -- atmIfVptIispStorageType, -- atmIfIispSigCurrentPmpConnections, -- atmIfIispAddrTermSPComponentName, -- atmIfIispSigVcdComponentName, -- atmIfVptIispSigSuccessfulPmpConnections, -- atmIfVptIispVersion, -- atmIfVptIispAddrReachability, -- atmIfIispAddrPnniInfoComponentName, -- atmIfVptIispSigVcdTrafficDescType, -- atmIfIispSigVcdTrafficShaping, -- atmIfVptIispAccountCollection, -- atmIfVptIispSigOperationalState, -- atmIfIispSigLastRxDiagCode, -- atmIfVptIispRowStatus, -- atmIfIispSigLastTxCauseCode, -- atmIfIispSigPeakPmpConnections, -- atmIfVptIispSoftPvpAndPvcHoldOffTime, -- atmIfVptIispSigPeakConnections, -- atmIfIispSigSuccessfulConnections, -- atmIfVptIispSigVcdAtmServiceCategory, -- atmIfVptIispAddrPnniInfoScope, -- atmIfIispSigVci, -- atmIfVptIispAddrTermSPStorageType, -- atmIfVptIispServiceExchange, -- atmIfIispSigNewCurrentConnections, -- atmIfVptIispAddrTermSPComponentName, -- atmIfVptIispSigAdminState, -- atmIfIispAccountClass, -- atmIfVptIispAddrRowStatus, -- atmIfIispSide, -- atmIfIispSigVcdTdpValue, -- atmIfIispAddrComponentName, -- atmIfIispComponentName, -- atmIfVptIispSigRowStatus, -- atmIfIispSigVcdTrafficDescType, -- atmIfIispSigLastRxCauseCode, -- atmIfIispSigVcdStorageType, -- atmIfVptIispSigStorageType } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." atmIispGroup OBJECT IDENTIFIER ::= { atmIispMIB 1 } atmIispGroupBE OBJECT IDENTIFIER ::= { atmIispGroup 5 } atmIispGroupBE00 OBJECT IDENTIFIER ::= { atmIispGroupBE 1 } atmIispGroupBE00A OBJECT IDENTIFIER ::= { atmIispGroupBE00 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "Passport Release 7.0 AtmIisp." -- STATUS mandatory -- DESCRIPTION "AtmIisp MIB: MIB Version BE00A, -- Software Version BG00S4C." -- SUPPORTS Nortel-Magellan-Passport-AtmIispMIB -- INCLUDES { atmIispGroupBE00A } atmIispCapabilities OBJECT IDENTIFIER ::= { atmIispMIB 3 } atmIispCapabilitiesBE OBJECT IDENTIFIER ::= { atmIispCapabilities 5 } atmIispCapabilitiesBE00 OBJECT IDENTIFIER ::= { atmIispCapabilitiesBE 1 } atmIispCapabilitiesBE00A OBJECT IDENTIFIER ::= { atmIispCapabilitiesBE00 2 } END