ADTRAN-FRPerform-MIB DEFINITIONS ::= BEGIN -- TITLE: ADTRAN FRPerform MIB -- VERSION: 3.0 -- DATE: 98/09/22 IMPORTS enterprises, Counter, IpAddress, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, ifIndex FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 adProdPhysAddress, adProducts, adMgmt, adtran FROM ADTRAN-MIB; -- OBJECT IDENTIFIERS adPerform OBJECT IDENTIFIER ::= { adtran 4 } adFRPerformmg OBJECT IDENTIFIER ::= { adPerform 1 } adFRPerformHistoryControl OBJECT IDENTIFIER ::= { adFRPerformmg 1 } adFRPerformCurrentPvcStatus OBJECT IDENTIFIER ::= { adFRPerformmg 2 } adFRPerformIntPvcStatus OBJECT IDENTIFIER ::= { adFRPerformmg 3 } adFRPerformIntPortStatus OBJECT IDENTIFIER ::= { adFRPerformmg 4 } adFRPerformIntPortError OBJECT IDENTIFIER ::= { adFRPerformmg 5 } adFRPerformIntHistoryTime OBJECT IDENTIFIER ::= { adFRPerformmg 6 } adFRPerformDayPvcStatus OBJECT IDENTIFIER ::= { adFRPerformmg 7 } adFRPerformDayPortStatus OBJECT IDENTIFIER ::= { adFRPerformmg 8 } adFRPerformDayPortError OBJECT IDENTIFIER ::= { adFRPerformmg 9 } adFRPerformDayHistoryTime OBJECT IDENTIFIER ::= { adFRPerformmg 10 } -- --The FRPerform history control -- adFRPerformHistoryIntLength OBJECT-TYPE SYNTAX INTEGER { min5(1), min10(2), min15(3), min20(4), min30(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This value selects the sampling interval period for data collected in the interval tables." ::= { adFRPerformHistoryControl 1 } adFRPerformCurrentIntTimeRemaining OBJECT-TYPE SYNTAX INTEGER (0..1800) ACCESS read-only STATUS mandatory DESCRIPTION "Seconds remaining in current Interval." ::= { adFRPerformHistoryControl 2 } adFRPerformCompletedInts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of completed intervals in interval tables." ::= { adFRPerformHistoryControl 3 } adFRPerformCompletedDays OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of completed days in day table." ::= { adFRPerformHistoryControl 4 } -- --The FRPerform current PVC status table -- adFRPerformCurrentPvcStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformCurrentPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformCurrentPvcStatus 1 } adFRPerformCurrentPvcStatusEntry OBJECT-TYPE SYNTAX AdFRPerformCurrentPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformCurrentPvcIfIndex, adFRPerformCurrentPvcStatusIndex } ::= { adFRPerformCurrentPvcStatusTable 1 } AdFRPerformCurrentPvcStatusEntry ::= SEQUENCE { adFRPerformCurrentPvcIfIndex INTEGER, adFRPerformCurrentPvcStatusIndex INTEGER, adFRPerformCurrentPvcState INTEGER, adFRPerformCurrentPvcStatistics INTEGER } adFRPerformCurrentPvcIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformCurrentPvcStatusEntry 1 } adFRPerformCurrentPvcStatusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformCurrentPvcStatusEntry 2 } adFRPerformCurrentPvcState OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Current state for this PVC." ::= { adFRPerformCurrentPvcStatusEntry 3 } adFRPerformCurrentPvcStatistics OBJECT-TYPE SYNTAX INTEGER { available(1), not-available(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether this PVC is managed and has statistics available or is not managed." ::= { adFRPerformCurrentPvcStatusEntry 4 } -- --The FRPerform interval PVC status table -- adFRPerformIntPvcStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformIntPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPvcStatus 1 } adFRPerformIntPvcStatusEntry OBJECT-TYPE SYNTAX AdFRPerformIntPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformIntPvcIfIndex, adFRPerformIntPvcIndex, adFRPerformIntPvcSlotIndex } ::= { adFRPerformIntPvcStatusTable 1 } AdFRPerformIntPvcStatusEntry ::= SEQUENCE { adFRPerformIntPvcIfIndex INTEGER, adFRPerformIntPvcIndex INTEGER, adFRPerformIntPvcSlotIndex INTEGER, adFRPerformIntPVCStateChange Counter, adFRPerformIntPVCInactiveTime Counter, adFRPerformIntPVCFramesRx Counter, adFRPerformIntPVCFramesTx Counter, adFRPerformIntPVCBytesRx Counter, adFRPerformIntPVCBytesTx Counter, adFRPerformIntPVCAvgThruputTx Gauge, adFRPerformIntPVCAvgThruputRx Gauge, adFRPerformIntPVCMaxThruputTx Counter, adFRPerformIntPVCMaxThruputRx Counter, adFRPerformIntPVCAvgUtilizationTx Gauge, adFRPerformIntPVCAvgUtilizationRx Gauge, adFRPerformIntPVCMaxUtilizationTx Counter, adFRPerformIntPVCMaxUtilizationRx Counter, adFRPerformIntPVCBurstTx Counter, adFRPerformIntPVCBurstRx Counter, adFRPerformIntPVCFecnRx Counter, adFRPerformIntPVCFecnTx Counter, adFRPerformIntPVCBecnRx Counter, adFRPerformIntPVCBecnTx Counter, adFRPerformIntPVCDeRx Counter, adFRPerformIntPVCDeTx Counter, adFRPerformIntPVCCrRx Counter, adFRPerformIntPVCCrTx Counter, adFRPerformIntPVCMinFrameSizeRx Counter, adFRPerformIntPVCMinFrameSizeTx Counter, adFRPerformIntPVCMaxFrameSizeRx Counter, adFRPerformIntPVCMaxFrameSizeTx Counter, adFRPerformIntPVCAvgFrameSizeRx Gauge, adFRPerformIntPVCAvgFrameSizeTx Gauge, adFRPerformIntPVCLostFrames Counter, adFRPerformIntPVCRemoteLostFrames Counter, adFRPerformIntPVCMaxDelay Gauge, adFRPerformIntPVCMinDelay Gauge, adFRPerformIntPVCAvgDelay Gauge, adFRPerformIntPVCTimeInDBU Counter, adFRPerformIntPVCIdleUtilRx Counter, adFRPerformIntPVCIdleUtilTx Counter, adFRPerformIntPVCLTTwntyPercUtilRx Counter, adFRPerformIntPVCLTTwntyPercUtilTx Counter, adFRPerformIntPVCTwntyToThrtyNinePercUtilRx Counter, adFRPerformIntPVCTwntyToThrtyNinePercUtilTx Counter, adFRPerformIntPVCFortyToFiftyNinePercUtilRx Counter, adFRPerformIntPVCFortyToFiftyNinePercUtilTx Counter, adFRPerformIntPVCSixtyToSeventyNinePercUtilRx Counter, adFRPerformIntPVCSixtyToSeventyNinePercUtilTx Counter, adFRPerformIntPVCGTEightyPercUtilRx Counter, adFRPerformIntPVCGTEightyPercUtilTx Counter } adFRPerformIntPvcIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPvcStatusEntry 1 } adFRPerformIntPvcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPvcStatusEntry 2 } adFRPerformIntPvcSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPvcStatusEntry 3 } adFRPerformIntPVCStateChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of state changes for this PVC for the interval." ::= { adFRPerformIntPvcStatusEntry 4 } adFRPerformIntPVCInactiveTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the PVC has been in the inactive state for the interval." ::= { adFRPerformIntPvcStatusEntry 5 } adFRPerformIntPVCFramesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 6 } adFRPerformIntPVCFramesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 7 } adFRPerformIntPVCBytesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 8 } adFRPerformIntPVCBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 9 } adFRPerformIntPVCAvgThruputTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Average Throughput the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 10 } adFRPerformIntPVCAvgThruputRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Average throughput the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 11 } adFRPerformIntPVCMaxThruputTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 12 } adFRPerformIntPVCMaxThruputRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 13 } adFRPerformIntPVCAvgUtilizationTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 14 } adFRPerformIntPVCAvgUtilizationRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 15 } adFRPerformIntPVCMaxUtilizationTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 16 } adFRPerformIntPVCMaxUtilizationRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 17 } adFRPerformIntPVCBurstTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "n/a" ::= { adFRPerformIntPvcStatusEntry 18 } adFRPerformIntPVCBurstRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "n/a" ::= { adFRPerformIntPvcStatusEntry 19 } adFRPerformIntPVCFecnRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FECNs the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 20 } adFRPerformIntPVCFecnTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FECNs the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 21 } adFRPerformIntPVCBecnRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BECNs the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 22 } adFRPerformIntPVCBecnTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BECNs the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 23 } adFRPerformIntPVCDeRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DEs the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 24 } adFRPerformIntPVCDeTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DEs the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 25 } adFRPerformIntPVCCrRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRs the PVC has received for the interval." ::= { adFRPerformIntPvcStatusEntry 26 } adFRPerformIntPVCCrTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRs the PVC has transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 27 } adFRPerformIntPVCMinFrameSizeRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Minimum Frame Size the PVC received for the interval." ::= { adFRPerformIntPvcStatusEntry 28 } adFRPerformIntPVCMinFrameSizeTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Minimum Frame Size the PVC transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 29 } adFRPerformIntPVCMaxFrameSizeRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Frame Size the PVC received for the interval." ::= { adFRPerformIntPvcStatusEntry 30 } adFRPerformIntPVCMaxFrameSizeTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Frame Size the PVC transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 31 } adFRPerformIntPVCAvgFrameSizeRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Frame Size the PVC received for the interval." ::= { adFRPerformIntPvcStatusEntry 32 } adFRPerformIntPVCAvgFrameSizeTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Frame Size the PVC transmitted for the interval." ::= { adFRPerformIntPvcStatusEntry 33 } adFRPerformIntPVCLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Lost Frames on the PVC for the interval. Applies only if Sequence Numbering is Enabled on the PVC." ::= { adFRPerformIntPvcStatusEntry 34 } adFRPerformIntPVCRemoteLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Remote Lost Frames on the PVC for the interval. Applies only if Sequence Numbering is Enabled on the PVC." ::= { adFRPerformIntPvcStatusEntry 35 } adFRPerformIntPVCMaxDelay OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Delay in milliseconds on the PVC for the interval. Applies only if Delay Measurement is Enabled for the PVC or PVC Diagnostics are being performed." ::= { adFRPerformIntPvcStatusEntry 36 } adFRPerformIntPVCMinDelay OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Minimum Delay in milliseconds on the PVC for the interval. Applies only if Delay Measurement is Enabled for the PVC or PVC Diagnostics are being performed." ::= { adFRPerformIntPvcStatusEntry 37 } adFRPerformIntPVCAvgDelay OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Delay in milliseconds on the PVC for the interval. Applies only if Delay Measurement is Enabled for the PVC or PVC Diagnostics are being performed." ::= { adFRPerformIntPvcStatusEntry 38 } adFRPerformIntPVCTimeInDBU OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the PVC is in the DBU state." ::= { adFRPerformIntPvcStatusEntry 39 } adFRPerformIntPVCIdleUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was received." ::= { adFRPerformIntPvcStatusEntry 40 } adFRPerformIntPVCIdleUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was transmitted." ::= { adFRPerformIntPvcStatusEntry 41 } adFRPerformIntPVCLTTwntyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are less than 20 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 42 } adFRPerformIntPVCLTTwntyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are less than 20 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 43 } adFRPerformIntPVCTwntyToThrtyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 20-39 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 44 } adFRPerformIntPVCTwntyToThrtyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 20-39 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 45 } adFRPerformIntPVCFortyToFiftyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 40-59 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 46 } adFRPerformIntPVCFortyToFiftyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 40-59 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 47 } adFRPerformIntPVCSixtyToSeventyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 60-79 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 48 } adFRPerformIntPVCSixtyToSeventyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 60-79 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 49 } adFRPerformIntPVCGTEightyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are greater than 80 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 50 } adFRPerformIntPVCGTEightyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are greater than 80 percent of the bandwidth ." ::= { adFRPerformIntPvcStatusEntry 51 } -- --The FRPerform interval Port status table -- adFRPerformIntPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformIntPortStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPortStatus 1 } adFRPerformIntPortStatusEntry OBJECT-TYPE SYNTAX AdFRPerformIntPortStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformIntIfIndex, adFRPerformIntPortSlotIndex } ::= { adFRPerformIntPortStatusTable 1 } AdFRPerformIntPortStatusEntry ::= SEQUENCE { adFRPerformIntIfIndex INTEGER, adFRPerformIntPortSlotIndex INTEGER, adFRPerformIntPortFramesRx Counter, adFRPerformIntPortFramesTx Counter, adFRPerformIntPortBytesRx Counter, adFRPerformIntPortBytesTx Counter, adFRPerformIntPortAvgThruputTx Gauge, adFRPerformIntPortAvgThruputRx Gauge, adFRPerformIntPortMaxThruputTx Counter, adFRPerformIntPortMaxThruputRx Counter, adFRPerformIntPortAvgUtilizationTx Gauge, adFRPerformIntPortAvgUtilizationRx Gauge, adFRPerformIntPortMaxUtilizationTx Counter, adFRPerformIntPortMaxUtilizationRx Counter, adFRPerformIntPortFullStatusRX Counter, adFRPerformIntPortFullStatusTx Counter, adFRPerformIntPortLIOnlyRX Counter, adFRPerformIntPortLIOnlyTx Counter, adFRPerformIntPortAsyncStatusFrame Counter, adFRPerformIntPortIdleUtilRx Counter, adFRPerformIntPortIdleUtilTx Counter, adFRPerformIntPortLTTwntyPercUtilRx Counter, adFRPerformIntPortLTTwntyPercUtilTx Counter, adFRPerformIntPortTwntyToThrtyNinePercUtilRx Counter, adFRPerformIntPortTwntyToThrtyNinePercUtilTx Counter, adFRPerformIntPortFortyToFiftyNinePercUtilRx Counter, adFRPerformIntPortFortyToFiftyNinePercUtilTx Counter, adFRPerformIntPortSixtyToSeventyNinePercUtilRx Counter, adFRPerformIntPortSixtyToSeventyNinePercUtilTx Counter, adFRPerformIntPortGTEightyPercUtilRx Counter, adFRPerformIntPortGTEightyPercUtilTx Counter } adFRPerformIntIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPortStatusEntry 1 } adFRPerformIntPortSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPortStatusEntry 2 } adFRPerformIntPortFramesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the Port received for the interval." ::= { adFRPerformIntPortStatusEntry 3 } adFRPerformIntPortFramesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the Port transmitted for the interval." ::= { adFRPerformIntPortStatusEntry 4 } adFRPerformIntPortBytesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes the Port received for the interrval." ::= { adFRPerformIntPortStatusEntry 5 } adFRPerformIntPortBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes the Port transmitted for the interrval." ::= { adFRPerformIntPortStatusEntry 6 } adFRPerformIntPortAvgThruputTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Throughput the Port transmitted for the interval." ::= { adFRPerformIntPortStatusEntry 7 } adFRPerformIntPortAvgThruputRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Throughput the Port received for the interval." ::= { adFRPerformIntPortStatusEntry 8 } adFRPerformIntPortMaxThruputTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the Port transmitted for the interval." ::= { adFRPerformIntPortStatusEntry 9 } adFRPerformIntPortMaxThruputRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the Port received for the interval." ::= { adFRPerformIntPortStatusEntry 10 } adFRPerformIntPortAvgUtilizationTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the Port transmitted for the interval." ::= { adFRPerformIntPortStatusEntry 11 } adFRPerformIntPortAvgUtilizationRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the Port received for the interval." ::= { adFRPerformIntPortStatusEntry 12 } adFRPerformIntPortMaxUtilizationTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the Port transmitted for the interval." ::= { adFRPerformIntPortStatusEntry 13 } adFRPerformIntPortMaxUtilizationRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the Port received for the interval." ::= { adFRPerformIntPortStatusEntry 14 } adFRPerformIntPortFullStatusRX OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling full status frames received." ::= { adFRPerformIntPortStatusEntry 15 } adFRPerformIntPortFullStatusTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling full status frames transmitted." ::= { adFRPerformIntPortStatusEntry 16 } adFRPerformIntPortLIOnlyRX OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling link integrity only frames received." ::= { adFRPerformIntPortStatusEntry 17 } adFRPerformIntPortLIOnlyTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling link integrity only frames transmitted." ::= { adFRPerformIntPortStatusEntry 18 } adFRPerformIntPortAsyncStatusFrame OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of single PVC status frames received." ::= { adFRPerformIntPortStatusEntry 19 } adFRPerformIntPortIdleUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was received." ::= { adFRPerformIntPortStatusEntry 20 } adFRPerformIntPortIdleUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was transmitted." ::= { adFRPerformIntPortStatusEntry 21 } adFRPerformIntPortLTTwntyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are less than 20 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 22 } adFRPerformIntPortLTTwntyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are less than 20 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 23 } adFRPerformIntPortTwntyToThrtyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 20-39 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 24 } adFRPerformIntPortTwntyToThrtyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 20-39 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 25 } adFRPerformIntPortFortyToFiftyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 40-59 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 26 } adFRPerformIntPortFortyToFiftyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 40-59 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 27 } adFRPerformIntPortSixtyToSeventyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 60-79 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 28 } adFRPerformIntPortSixtyToSeventyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 60-79 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 29 } adFRPerformIntPortGTEightyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are greater than 80 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 30 } adFRPerformIntPortGTEightyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are greater than 80 percent of the bandwidth ." ::= { adFRPerformIntPortStatusEntry 31 } -- --The FRPerform interval port error table -- adFRPerformIntPortErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformIntPortErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPortError 1 } adFRPerformIntPortErrorEntry OBJECT-TYPE SYNTAX AdFRPerformIntPortErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformIntPortIndex, adFRPerformIntPortErrorSlotIndex } ::= { adFRPerformIntPortErrorTable 1 } AdFRPerformIntPortErrorEntry ::= SEQUENCE { adFRPerformIntPortIndex INTEGER, adFRPerformIntPortErrorSlotIndex INTEGER, adFRPerformIntPortUnavailableTime Counter, adFRPerformIntCrcErrors Counter, adFRPerformIntAbortFrames Counter, adFRPerformIntOctectViolations Counter, adFRPerformIntDiscardFrames Counter, adFRPerformIntLengthErrors Counter, adFRPerformIntEAViolations Counter, adFRPerformIntEncapsulationErrors Counter, adFRPerformIntInactiveDLCI Counter, adFRPerformIntInvalidDLCI Counter, adFRPerformIntUnroutable Counter, adFRPerformIntSignalDownTime Counter, adFRPerformIntSignalErrors Counter, adFRPerformIntSignalTimeOut Counter, adFRPerformIntSignalStateChange Counter } adFRPerformIntPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPortErrorEntry 1 } adFRPerformIntPortErrorSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntPortErrorEntry 2 } adFRPerformIntPortUnavailableTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the port is unavailable due to a physical or frame relay outage." ::= { adFRPerformIntPortErrorEntry 3 } adFRPerformIntCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with CRC errors." ::= { adFRPerformIntPortErrorEntry 4 } adFRPerformIntAbortFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received without proper flag termination." ::= { adFRPerformIntPortErrorEntry 5 } adFRPerformIntOctectViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with a bit count not divisible by eigth." ::= { adFRPerformIntPortErrorEntry 6 } adFRPerformIntDiscardFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames discarded by the IQ unit" ::= { adFRPerformIntPortErrorEntry 7 } adFRPerformIntLengthErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received that is less than 5 bytes or greater than 4500 bytes." ::= { adFRPerformIntPortErrorEntry 8 } adFRPerformIntEAViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with errors in the EA field of the frame relay header." ::= { adFRPerformIntPortErrorEntry 9 } adFRPerformIntEncapsulationErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames destined for the IQ IP stack with that does not meet the FRF.3 IA." ::= { adFRPerformIntPortErrorEntry 10 } adFRPerformIntInactiveDLCI OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received while the PVC is in the inactive state." ::= { adFRPerformIntPortErrorEntry 11 } adFRPerformIntInvalidDLCI OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with a DLCI value less than 16 or greater than 1007 not including PVC signaling frames." ::= { adFRPerformIntPortErrorEntry 12 } adFRPerformIntUnroutable OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received on a management DLCI destined for the IQ unit and have the wrong IP address." ::= { adFRPerformIntPortErrorEntry 13 } adFRPerformIntSignalDownTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the signaling state has been down." ::= { adFRPerformIntPortErrorEntry 14 } adFRPerformIntSignalErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling frames received with protocol violations." ::= { adFRPerformIntPortErrorEntry 15 } adFRPerformIntSignalTimeOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signal timeouts. Either T391 seconds elapsed without receiving a response to a poll or T392 elapsed seconds with receiving a poll." ::= { adFRPerformIntPortErrorEntry 16 } adFRPerformIntSignalStateChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of state changes for the PVC signaling protocol. This includes transitions from down state to up state and vice versa." ::= { adFRPerformIntPortErrorEntry 17 } -- --The FRPerform interval time stamp table -- adFRPerformIntHistoryTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformIntHistoryTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntHistoryTime 1 } adFRPerformIntHistoryTimeEntry OBJECT-TYPE SYNTAX AdFRPerformIntHistoryTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformIntHistoryTimeSlotIndex } ::= { adFRPerformIntHistoryTimeTable 1 } AdFRPerformIntHistoryTimeEntry ::= SEQUENCE { adFRPerformIntHistoryTimeSlotIndex INTEGER, adFRPerformIntHistorySlotTotalTime INTEGER, adFRPerformIntHistoryTimeStamp DisplayString } adFRPerformIntHistoryTimeSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformIntHistoryTimeEntry 1 } adFRPerformIntHistorySlotTotalTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total time in seconds this interval slot represents." ::= { adFRPerformIntHistoryTimeEntry 2 } adFRPerformIntHistoryTimeStamp OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time interval started. Format H:M if not midnight else M-D" ::= { adFRPerformIntHistoryTimeEntry 3 } -- --The FRPerform day PVC status table -- adFRPerformDayPvcStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformDayPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPvcStatus 1 } adFRPerformDayPvcStatusEntry OBJECT-TYPE SYNTAX AdFRPerformDayPvcStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformDayPvcIfIndex, adFRPerformDayPvcIndex, adFRPerformDayPvcSlotIndex } ::={ adFRPerformDayPvcStatusTable 1 } AdFRPerformDayPvcStatusEntry ::= SEQUENCE { adFRPerformDayPvcIfIndex INTEGER, adFRPerformDayPvcIndex INTEGER, adFRPerformDayPvcSlotIndex INTEGER, adFRPerformDayPVCStateChange Counter, adFRPerformDayPVCInactiveTime Counter, adFRPerformDayPVCFramesRx Counter, adFRPerformDayPVCFramesTx Counter, adFRPerformDayPVCBytesRx Counter, adFRPerformDayPVCBytesTx Counter, adFRPerformDayPVCAvgThruputTx Gauge, adFRPerformDayPVCAvgThruputRx Gauge, adFRPerformDayPVCMaxThruputTx Counter, adFRPerformDayPVCMaxThruputRx Counter, adFRPerformDayPVCAvgUtilizationTx Gauge, adFRPerformDayPVCAvgUtilizationRx Gauge, adFRPerformDayPVCMaxUtilizationTx Counter, adFRPerformDayPVCMaxUtilizationRx Counter, adFRPerformDayPVCBurstTx Counter, adFRPerformDayPVCBurstRx Counter, adFRPerformDayPVCFecnRx Counter, adFRPerformDayPVCFecnTx Counter, adFRPerformDayPVCBecnRx Counter, adFRPerformDayPVCBecnTx Counter, adFRPerformDayPVCDeRx Counter, adFRPerformDayPVCDeTx Counter, adFRPerformDayPVCCrRx Counter, adFRPerformDayPVCCrTx Counter, adFRPerformDayPVCMinFrameSizeRx Counter, adFRPerformDayPVCMinFrameSizeTx Counter, adFRPerformDayPVCMaxFrameSizeRx Counter, adFRPerformDayPVCMaxFrameSizeTx Counter, adFRPerformDayPVCAvgFrameSizeRx Gauge, adFRPerformDayPVCAvgFrameSizeTx Gauge, adFRPerformDayPVCLostFrames Counter, adFRPerformDayPVCRemoteLostFrames Counter, adFRPerformDayPVCMaxDelay Gauge, adFRPerformDayPVCMinDelay Gauge, adFRPerformDayPVCAvgDelay Gauge, adFRPerformDayPVCTimeInDBU Counter, adFRPerformDayPVCIdleUtilRx Counter, adFRPerformDayPVCIdleUtilTx Counter, adFRPerformDayPVCLTTwntyPercUtilRx Counter, adFRPerformDayPVCLTTwntyPercUtilTx Counter, adFRPerformDayPVCTwntyToThrtyNinePercUtilRx Counter, adFRPerformDayPVCTwntyToThrtyNinePercUtilTx Counter, adFRPerformDayPVCFortyToFiftyNinePercUtilRx Counter, adFRPerformDayPVCFortyToFiftyNinePercUtilTx Counter, adFRPerformDayPVCSixtyToSeventyNinePercUtilRx Counter, adFRPerformDayPVCSixtyToSeventyNinePercUtilTx Counter, adFRPerformDayPVCGTEightyPercUtilRx Counter, adFRPerformDayPVCGTEightyPercUtilTx Counter } adFRPerformDayPvcIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPvcStatusEntry 1 } adFRPerformDayPvcIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPvcStatusEntry 2 } adFRPerformDayPvcSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPvcStatusEntry 3 } adFRPerformDayPVCStateChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of State Changes on the PVC for the day." ::= { adFRPerformDayPvcStatusEntry 4 } adFRPerformDayPVCInactiveTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the PVC has been in the inactive state." ::= { adFRPerformDayPvcStatusEntry 5 } adFRPerformDayPVCFramesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 6 } adFRPerformDayPVCFramesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 7 } adFRPerformDayPVCBytesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 8 } adFRPerformDayPVCBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 9 } adFRPerformDayPVCAvgThruputTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Throughput the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 10 } adFRPerformDayPVCAvgThruputRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Throughput the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 11 } adFRPerformDayPVCMaxThruputTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 12 } adFRPerformDayPVCMaxThruputRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 13 } adFRPerformDayPVCAvgUtilizationTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 14 } adFRPerformDayPVCAvgUtilizationRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 15 } adFRPerformDayPVCMaxUtilizationTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 16 } adFRPerformDayPVCMaxUtilizationRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 17 } adFRPerformDayPVCBurstTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "n/a" ::= { adFRPerformDayPvcStatusEntry 18 } adFRPerformDayPVCBurstRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "n/a" ::= { adFRPerformDayPvcStatusEntry 19 } adFRPerformDayPVCFecnRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FECNs the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 20 } adFRPerformDayPVCFecnTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FECNs the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 21 } adFRPerformDayPVCBecnRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BECNs the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 22 } adFRPerformDayPVCBecnTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of BECNs the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 23 } adFRPerformDayPVCDeRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DEs the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 24 } adFRPerformDayPVCDeTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DEs the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 25 } adFRPerformDayPVCCrRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRs the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 26 } adFRPerformDayPVCCrTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRs the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 27 } adFRPerformDayPVCMinFrameSizeRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Minimum Frame Size the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 28 } adFRPerformDayPVCMinFrameSizeTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Minimum Frame Size the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 29 } adFRPerformDayPVCMaxFrameSizeRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Frame Size the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 30 } adFRPerformDayPVCMaxFrameSizeTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Frame Size the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 31 } adFRPerformDayPVCAvgFrameSizeRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Frame Size the PVC received for the day." ::= { adFRPerformDayPvcStatusEntry 32 } adFRPerformDayPVCAvgFrameSizeTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Frame Size the PVC transmitted for the day." ::= { adFRPerformDayPvcStatusEntry 33 } adFRPerformDayPVCLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Lost Frames on the PVC for the day. Applies only if Sequence Numbering is Enabled for the PVC." ::= { adFRPerformDayPvcStatusEntry 34 } adFRPerformDayPVCRemoteLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Remote Lost Frames on the PVC for the day. Applies only if Sequence Numbering is Enabled for the PVC." ::= { adFRPerformDayPvcStatusEntry 35 } adFRPerformDayPVCMaxDelay OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Delay on the PVC for the day. Applies only if Delay Measurement or PVC Diagnostics are Enabled for the PVC." ::= { adFRPerformDayPvcStatusEntry 36 } adFRPerformDayPVCMinDelay OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Minimum Delay on the PVC for the day. Applies only if Delay Measurement or PVC Diagnostics are Enabled for the PVC." ::= { adFRPerformDayPvcStatusEntry 37 } adFRPerformDayPVCAvgDelay OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Delay on the PVC for the day. Applies only if Delay Measurement or PVC Diagnostics are Enabled for the PVC." ::= { adFRPerformDayPvcStatusEntry 38 } adFRPerformDayPVCTimeInDBU OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the PVC is in the DBU state." ::= { adFRPerformDayPvcStatusEntry 39 } adFRPerformDayPVCIdleUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was received." ::= { adFRPerformDayPvcStatusEntry 40 } adFRPerformDayPVCIdleUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was transmitted." ::= { adFRPerformDayPvcStatusEntry 41 } adFRPerformDayPVCLTTwntyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are less than 20 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 42 } adFRPerformDayPVCLTTwntyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are less than 20 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 43 } adFRPerformDayPVCTwntyToThrtyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 20-39 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 44 } adFRPerformDayPVCTwntyToThrtyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 20-39 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 45 } adFRPerformDayPVCFortyToFiftyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 40-59 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 46 } adFRPerformDayPVCFortyToFiftyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 40-59 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 47 } adFRPerformDayPVCSixtyToSeventyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 60-79 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 48 } adFRPerformDayPVCSixtyToSeventyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 60-79 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 49 } adFRPerformDayPVCGTEightyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are greater than 80 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 50 } adFRPerformDayPVCGTEightyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are greater than 80 percent of the bandwidth ." ::= { adFRPerformDayPvcStatusEntry 51 } -- --The FRPerform day port status table -- adFRPerformDayPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformDayPortStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPortStatus 1 } adFRPerformDayPortStatusEntry OBJECT-TYPE SYNTAX AdFRPerformDayPortStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformDayIfIndex, adFRPerformDayPortSlotIndex } ::= { adFRPerformDayPortStatusTable 1 } AdFRPerformDayPortStatusEntry ::= SEQUENCE { adFRPerformDayIfIndex INTEGER, adFRPerformDayPortSlotIndex INTEGER, adFRPerformDayPortFramesRx Counter, adFRPerformDayPortFramesTx Counter, adFRPerformDayPortBytesRx Counter, adFRPerformDayPortBytesTx Counter, adFRPerformDayPortAvgThruputTx Gauge, adFRPerformDayPortAvgThruputRx Gauge, adFRPerformDayPortMaxThruputTx Counter, adFRPerformDayPortMaxThruputRx Counter, adFRPerformDayPortAvgUtilizationTx Gauge, adFRPerformDayPortAvgUtilizationRx Gauge, adFRPerformDayPortMaxUtilizationTx Counter, adFRPerformDayPortMaxUtilizationRx Counter, adFRPerformDayPortFullStatusRX Counter, adFRPerformDayPortFullStatusTx Counter, adFRPerformDayPortLIOnlyRX Counter, adFRPerformDayPortLIOnlyTx Counter, adFRPerformDayPortAsyncStatusFrame Counter, adFRPerformDayPortIdleUtilRx Counter, adFRPerformDayPortIdleUtilTx Counter, adFRPerformDayPortLTTwntyPercUtilRx Counter, adFRPerformDayPortLTTwntyPercUtilTx Counter, adFRPerformDayPortTwntyToThrtyNinePercUtilRx Counter, adFRPerformDayPortTwntyToThrtyNinePercUtilTx Counter, adFRPerformDayPortFortyToFiftyNinePercUtilRx Counter, adFRPerformDayPortFortyToFiftyNinePercUtilTx Counter, adFRPerformDayPortSixtyToSeventyNinePercUtilRx Counter, adFRPerformDayPortSixtyToSeventyNinePercUtilTx Counter, adFRPerformDayPortGTEightyPercUtilRx Counter, adFRPerformDayPortGTEightyPercUtilTx Counter } adFRPerformDayIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPortStatusEntry 1 } adFRPerformDayPortSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPortStatusEntry 2 } adFRPerformDayPortFramesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the Port received for the day." ::= { adFRPerformDayPortStatusEntry 3 } adFRPerformDayPortFramesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Frames the Port transmitted for the day." ::= { adFRPerformDayPortStatusEntry 4 } adFRPerformDayPortBytesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes the Port received for the day." ::= { adFRPerformDayPortStatusEntry 5 } adFRPerformDayPortBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "he number of Bytes the Port transmitted for the day." ::= { adFRPerformDayPortStatusEntry 6 } adFRPerformDayPortAvgThruputTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Throughput the Port transmitted for the day." ::= { adFRPerformDayPortStatusEntry 7 } adFRPerformDayPortAvgThruputRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Throughput the Port received for the day." ::= { adFRPerformDayPortStatusEntry 8 } adFRPerformDayPortMaxThruputTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the Port transmitted for the day." ::= { adFRPerformDayPortStatusEntry 9 } adFRPerformDayPortMaxThruputRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Throughput the Port received for the day." ::= { adFRPerformDayPortStatusEntry 10 } adFRPerformDayPortAvgUtilizationTx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the Port transmitted for the day." ::= { adFRPerformDayPortStatusEntry 11 } adFRPerformDayPortAvgUtilizationRx OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The Average Utilization the Port received for the day." ::= { adFRPerformDayPortStatusEntry 12 } adFRPerformDayPortMaxUtilizationTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the Port transmitted for the day." ::= { adFRPerformDayPortStatusEntry 13 } adFRPerformDayPortMaxUtilizationRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Maximum Utilization the Port received for the day." ::= { adFRPerformDayPortStatusEntry 14 } adFRPerformDayPortFullStatusRX OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling full status frames received." ::= { adFRPerformDayPortStatusEntry 15 } adFRPerformDayPortFullStatusTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling full status frames transmitted." ::= { adFRPerformDayPortStatusEntry 16 } adFRPerformDayPortLIOnlyRX OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling link integrity only frames received." ::= { adFRPerformDayPortStatusEntry 17 } adFRPerformDayPortLIOnlyTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling link integrity only frames transmitted." ::= { adFRPerformDayPortStatusEntry 18 } adFRPerformDayPortAsyncStatusFrame OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of single PVC status frames received." ::= { adFRPerformDayPortStatusEntry 19 } adFRPerformDayPortIdleUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was received." ::= { adFRPerformDayPortStatusEntry 20 } adFRPerformDayPortIdleUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples that no data was transmitted." ::= { adFRPerformDayPortStatusEntry 21 } adFRPerformDayPortLTTwntyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are less than 20 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 22 } adFRPerformDayPortLTTwntyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are less than 20 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 23 } adFRPerformDayPortTwntyToThrtyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 20-39 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 24 } adFRPerformDayPortTwntyToThrtyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 20-39 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 25 } adFRPerformDayPortFortyToFiftyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 40-59 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 26 } adFRPerformDayPortFortyToFiftyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 40-59 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 27 } adFRPerformDayPortSixtyToSeventyNinePercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are in 60-79 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 28 } adFRPerformDayPortSixtyToSeventyNinePercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are in 60-79 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 29 } adFRPerformDayPortGTEightyPercUtilRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples received that are greater than 80 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 30 } adFRPerformDayPortGTEightyPercUtilTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of (bytes/sec) samples transmitted that are greater than 80 percent of the bandwidth ." ::= { adFRPerformDayPortStatusEntry 31 } -- --The FRPerform day port error table -- adFRPerformDayPortErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformDayPortErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPortError 1 } adFRPerformDayPortErrorEntry OBJECT-TYPE SYNTAX AdFRPerformDayPortErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformDayPortIndex, adFRPerformDayPortErrorSlotIndex } ::= { adFRPerformDayPortErrorTable 1 } AdFRPerformDayPortErrorEntry ::= SEQUENCE { adFRPerformDayPortIndex INTEGER, adFRPerformDayPortErrorSlotIndex INTEGER, adFRPerformDayPortUnavailableTime Counter, adFRPerformDayCrcErrors Counter, adFRPerformDayAbortFrames Counter, adFRPerformDayOctectViolations Counter, adFRPerformDayDiscardFrames Counter, adFRPerformDayLengthErrors Counter, adFRPerformDayEAViolations Counter, adFRPerformDayEncapsulationErrors Counter, adFRPerformDayInactiveDLCI Counter, adFRPerformDayInvalidDLCI Counter, adFRPerformDayUnroutable Counter, adFRPerformDaySignalDownTime Counter, adFRPerformDaySignalErrors Counter, adFRPerformDaySignalTimeOut Counter, adFRPerformDaySignalStateChange Counter } adFRPerformDayPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPortErrorEntry 1 } adFRPerformDayPortErrorSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayPortErrorEntry 2 } adFRPerformDayPortUnavailableTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the port is unavailable due to a physical or frame relay outage." ::= { adFRPerformDayPortErrorEntry 3 } adFRPerformDayCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with CRC errors." ::= { adFRPerformDayPortErrorEntry 4 } adFRPerformDayAbortFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received without proper flag termination." ::= { adFRPerformDayPortErrorEntry 5 } adFRPerformDayOctectViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with a bit count not divisible by eigth." ::= { adFRPerformDayPortErrorEntry 6 } adFRPerformDayDiscardFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames discarded by the IQ unit" ::= { adFRPerformDayPortErrorEntry 7 } adFRPerformDayLengthErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received that is less than 5 bytes or greater than 4500 bytes." ::= { adFRPerformDayPortErrorEntry 8 } adFRPerformDayEAViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with errors in the EA field of the frame relay header." ::= { adFRPerformDayPortErrorEntry 9 } adFRPerformDayEncapsulationErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames destined for the IQ IP stack with that does not meet the FRF.3 IA." ::= { adFRPerformDayPortErrorEntry 10 } adFRPerformDayInactiveDLCI OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received while the PVC is in the inactive state." ::= { adFRPerformDayPortErrorEntry 11 } adFRPerformDayInvalidDLCI OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with a DLCI value less than 16 or greater than 1007 not including PVC signaling frames." ::= { adFRPerformDayPortErrorEntry 12 } adFRPerformDayUnroutable OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received on a management DLCI destined for the IQ unit and have the wrong IP address." ::= { adFRPerformDayPortErrorEntry 13 } adFRPerformDaySignalDownTime OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds the signaling state has been down." ::= { adFRPerformDayPortErrorEntry 14 } adFRPerformDaySignalErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signaling frames received with protocol violations." ::= { adFRPerformDayPortErrorEntry 15 } adFRPerformDaySignalTimeOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of PVC signal timeouts. Either T391 seconds elapsed without receiving a response to a poll or T392 elapsed seconds with receiving a poll." ::= { adFRPerformDayPortErrorEntry 16 } adFRPerformDaySignalStateChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of state changes for the PVC signaling protocol. This includes transitions from down state to up state and vice versa." ::= { adFRPerformDayPortErrorEntry 17 } -- --The FRPerform day time stamp table -- adFRPerformDayHistoryTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF AdFRPerformDayHistoryTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayHistoryTime 1 } adFRPerformDayHistoryTimeEntry OBJECT-TYPE SYNTAX AdFRPerformDayHistoryTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "n/a" INDEX { adFRPerformDayHistoryTimeSlotIndex } ::= { adFRPerformDayHistoryTimeTable 1 } AdFRPerformDayHistoryTimeEntry ::= SEQUENCE { adFRPerformDayHistoryTimeSlotIndex INTEGER, adFRPerformDayHistorySlotTotalTime INTEGER, adFRPerformDayHistoryTimeStamp DisplayString } adFRPerformDayHistoryTimeSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "n/a." ::= { adFRPerformDayHistoryTimeEntry 1 } adFRPerformDayHistorySlotTotalTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds this day slot represents." ::= { adFRPerformDayHistoryTimeEntry 2 } adFRPerformDayHistoryTimeStamp OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Date the day slot started. Format M-D" ::= { adFRPerformDayHistoryTimeEntry 3 } END