CTRON-SFCS-MIB DEFINITIONS ::= BEGIN -- ctron-sfcs-mib.txt -- Revision: 1.00.01 -- Date: March 23, 1999 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for Cabletron's -- enterprise specific Secure Fast Cell Switching MIB. -- -- This module will be extended, as required. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright October 98 Cabletron Systems -- IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB enterprises, IpAddress, TimeTicks FROM RFC1155-SMI TruthValue FROM SNMPv2-TC atmVcCrossConnectIndex, atmVcCrossConnectLowIfIndex, atmVcCrossConnectLowVpi, atmVcCrossConnectLowVci, atmVcCrossConnectHighIfIndex, atmVcCrossConnectHighVpi, atmVcCrossConnectHighVci FROM ATM-MIB; cabletron OBJECT IDENTIFIER ::= { enterprises 52 } mibs OBJECT IDENTIFIER ::= { cabletron 4 } ctron OBJECT IDENTIFIER ::= { mibs 1 } ctDataLink OBJECT IDENTIFIER ::= { ctron 2 } ctSwitch OBJECT IDENTIFIER ::= { ctDataLink 11 } ctsfSwitch OBJECT IDENTIFIER ::= { ctSwitch 1 } ctSFCS OBJECT IDENTIFIER ::= { ctsfSwitch 1 } -- The SFCS Groups. -- The SFCS System Groups (switch system) sfcsSystem OBJECT IDENTIFIER ::= { ctSFCS 1 } sfcsSysConfig OBJECT IDENTIFIER ::= { sfcsSystem 1 } sfcsSysStatus OBJECT IDENTIFIER ::= { sfcsSystem 2 } sfcsSysSystemCfg OBJECT IDENTIFIER ::= { sfcsSystem 3 } sfcsSysBPCfg OBJECT IDENTIFIER ::= { sfcsSystem 4 } -- All groups from here on represent a single switch module -- The SFCS Engine Groups sfcsEngine OBJECT IDENTIFIER ::= { ctSFCS 2 } sfcsConfig OBJECT IDENTIFIER ::= { sfcsEngine 1 } sfcsStatus OBJECT IDENTIFIER ::= { sfcsEngine 2 } sfcsUPCEngine OBJECT IDENTIFIER ::= { sfcsEngine 3 } sfcsStatisticsEngine OBJECT IDENTIFIER ::= { sfcsEngine 4 } sfcsPacketDiscardEngine OBJECT IDENTIFIER ::= { sfcsEngine 5 } -- The SFCS ANIM Groups sfcsANIM OBJECT IDENTIFIER ::= { ctSFCS 3 } sfcsANIMConfig OBJECT IDENTIFIER ::= { sfcsANIM 1 } sfcsANIMStatistics OBJECT IDENTIFIER ::= { sfcsANIM 2 } sfcsANIMPic OBJECT IDENTIFIER ::= { sfcsANIM 3 } -- The SFCS Interface Groups sfcsInterface OBJECT IDENTIFIER ::= { ctSFCS 4 } sfcsInterfaceConfig OBJECT IDENTIFIER ::= { sfcsInterface 1 } sfcsInterfaceStatistics OBJECT IDENTIFIER ::= { sfcsInterface 2 } -- The SFCS Queue Groups sfcsQueue OBJECT IDENTIFIER ::= { ctSFCS 5 } sfcsQueueConfig OBJECT IDENTIFIER ::= { sfcsQueue 1 } sfcsQueueStatistics OBJECT IDENTIFIER ::= { sfcsQueue 2 } -- The SFCS Connection Groups sfcsConnection OBJECT IDENTIFIER ::= { ctSFCS 7 } sfcsConnectionConfig OBJECT IDENTIFIER ::= { sfcsConnection 1 } sfcsConnectionStatistics OBJECT IDENTIFIER ::= { sfcsConnection 2 } sfcsConnectionError OBJECT IDENTIFIER ::= { sfcsConnection 3 } -- The SFCS Connection API Group sfcsConnectionAPI OBJECT IDENTIFIER ::= { ctSFCS 8 } -- The SFCS CTM Groups sfcsCTM OBJECT IDENTIFIER ::= { ctSFCS 9 } sfcsCTMInterfaceConfig OBJECT IDENTIFIER ::= { sfcsCTM 1 } sfcsCTMInterfaceStatistics OBJECT IDENTIFIER ::= { sfcsCTM 2 } sfcsCTMQueueConfig OBJECT IDENTIFIER ::= { sfcsCTM 3 } sfcsCTMQueueStatistics OBJECT IDENTIFIER ::= { sfcsCTM 4 } -- The SFCS Bandwidth Managment Groups sfcsBWMgr OBJECT IDENTIFIER ::= { ctSFCS 12 } sfcsBwNims OBJECT IDENTIFIER ::= { sfcsBWMgr 1 } sfcsBwPorts OBJECT IDENTIFIER ::= { sfcsBWMgr 2 } sfcsBwPortPools OBJECT IDENTIFIER ::= { sfcsBWMgr 3 } sfcsBuffPools OBJECT IDENTIFIER ::= { sfcsBWMgr 4 } -- The ANIM Proxy Groups sfcsProxy OBJECT IDENTIFIER ::= { ctSFCS 13 } sfcsProxyConfig OBJECT IDENTIFIER ::= { sfcsProxy 1 } sfcsProxyTrans OBJECT IDENTIFIER ::= { sfcsProxy 2 } sfcsProxyRead OBJECT IDENTIFIER ::= { sfcsProxy 3 } sfcsSysConfigTable OBJECT IDENTIFIER ::= { sfcsSysConfig 1 } sfcsSysConfigEnt OBJECT IDENTIFIER ::= { sfcsSysConfigTable 1 } sfcsSysConfigAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- startup the SFCS disabled(2), -- shutdown the SFCS other(3) -- none of the following } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SFCS switching services for this virtual switch. This controls the SFCS state at a chassis level. Regardless of the per-interface state of each SFCS switching element and the state of active connections, writing the value disabled(2) will cause the entire switch to immediately shutdown. enabled(1) -- startup the SFCS disabled(2) -- shutdown the SFCS other(3) -- none of the following" ::= { sfcsSysConfigEnt 1 } sfcsSysConfigOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- running disabled(2), -- not running other(3), -- none of the following pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of this switch. enabled(1) -- running disabled(2) -- not running other(3) -- none of the following pending-disable(4) -- shut-down in progress pending-enable(5) -- start-up in progress invalid-config(6) -- not running,invalid config" ::= { sfcsSysConfigEnt 2 } sfcsSysConfigOperTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time (# of time ticks) that this switch system has been in its current operational state." ::= { sfcsSysConfigEnt 3 } sfcsSysConfigLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the last time a change was made to the configuration entry for this switch." ::= { sfcsSysConfigEnt 4 } sfcsSysConfigSwitchCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum front panel bandwidth based on current hardware configuration of the switch in Mbps" ::= { sfcsSysConfigEnt 5 } sfcsSysConfigMaxCnxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of connections which can be established on this switch." ::= { sfcsSysConfigEnt 6 } sfcsSysConfigMaxStatEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of stats enabled VCs for this switch." ::= { sfcsSysConfigEnt 7 } sfcsSysConfigMaxUpcEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of UPC enabled VCs for this switch." ::= { sfcsSysConfigEnt 8 } sfcsSysConfigNumberANIMS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of ATM Network Inteface Modules currently configured on this switch." ::= { sfcsSysConfigEnt 9 } sfcsSysConfigInterfaceCapability OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total bandwidth capability(of the engine) for this switch expressed in Mbps." ::= { sfcsSysConfigEnt 10 } sfcsSysConfigTypeofSwitch OBJECT-TYPE SYNTAX INTEGER { other (1), sfcellswitch (2), sfpacketswitch (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates what type of switch this is. other(1) sfcellswitch(2) sfpacketswitch(3)" ::= { sfcsSysConfigEnt 11 } sfcsSysConfigPolicingSupport OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether or not this switch supports policing. supported(1) not supported(2)" ::= { sfcsSysConfigEnt 12 } sfcsSysConfigPnniNsapPrefix OBJECT-TYPE SYNTAX OCTET STRING (SIZE(13)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the 13 byte NSAP prefix to use with address registration." ::= { sfcsSysConfigEnt 13 } sfcsSysConfigPnniNodeLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the PNNI node level value. The range can be from 0 to 104." ::= { sfcsSysConfigEnt 14 } sfcsSysConfigPnniAddessingMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the PNNI addressing mode - that can range from 0 to 2. 0 - Auto Mode using MAC 1 - Auto Mode using board# 2 - Manual " ::= { sfcsSysConfigEnt 15 } sfcsSysConfigPnniAddessingAdmnStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the PNNI addressing admn status. Down - 2. Up - 1." ::= { sfcsSysConfigEnt 16 } sfcsSysConfigFMVer OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the Firmware Revision of the switch." ::= { sfcsSysConfigEnt 17 } sfcsSysConfigCTMSlotMask OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the slot mask for all ctm boards in the chassis. The least significant bit represents slot 1." ::= { sfcsSysConfigEnt 18 } sfcsSysConfigMaxfreecva OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum number of CAC connection blocks that CAC will allow on its free list. The default is 1024. If too low CAC performance will degrade (thrashing control blocks), If too high, memory exhaustion may occur. " ::= { sfcsSysConfigEnt 19 } sfcsSysConfigUBR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "For the set operation: UBR_Cfg is set across all boards in the chassis (that are operational and manageable). For the get operation: UBR_Cfg setting is retrived from the current chassis manager only (one slot only). IF boards are introduced or re-introduced to the chassis their UBR value will be 0. In order to insure a required UBR_Cfg value the set operation should be proformed after slot insertions or re-insertions are completed to the chassis. " ::= { sfcsSysConfigEnt 20 } -- SFCS System Status Table -- This table contains the objects that pertain to the operational status -- of a virtual switch. sfcsSysStatusTable OBJECT IDENTIFIER ::= { sfcsSysStatus 1 } sfcsSysStatusEnt OBJECT IDENTIFIER ::= { sfcsSysStatusTable 1 } sfcsSysStatusTdmCellCount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of cells being transfered across the TDM for the entire switch." ::= { sfcsSysStatusEnt 1 } sfcsSysStatusTdmUtilization OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total percentage TDM utilization for the switch." ::= { sfcsSysStatusEnt 2 } sfcsSysStatusCurrCnxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current number of connection entries for this switch." ::= { sfcsSysStatusEnt 3 } sfcsSysStatusCurrUPCEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current number of UPC entries for this switch." ::= { sfcsSysStatusEnt 4 } sfcsSysStatusCurrStatsEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current number of statistics entries for this switch." ::= { sfcsSysStatusEnt 5 } sfcsSysStatusAllocatedBw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current allocated bandwidth of the switch in bits per second." ::= { sfcsSysStatusEnt 6 } -- SFCS System Configuration Table set up as a SYSTEM MIB -- This table contains the objects that pertain to the setup and -- configuration of the virtual switch. sfcsSysSystemCfgTable OBJECT IDENTIFIER ::= { sfcsSysSystemCfg 1 } sfcsSysSystemCfgEnt OBJECT IDENTIFIER ::= { sfcsSysSystemCfgTable 1 } sfcsSysConfigAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets this virtual switch. Writing a value of reset(2) will force a restart of the entire switch, without any graceful shutdown. Any active connections or services will be interrupted. other(1) -- none of the following reset(2) -- force a reset" ::= { sfcsSysSystemCfgEnt 1 } sfcsSysConfigATOMPersistance OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables or disables ATOM mib persistance. enabled(1) disabled(2)" ::= { sfcsSysSystemCfgEnt 2 } sfcsSysConfigVcSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This entry is the size of VCs allocated for all VPs in the switch." ::= { sfcsSysSystemCfgEnt 3 } sfcsSysConfigPowerUpDiags OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables or disables power up diags. enabled(1) disabled(2)" ::= { sfcsSysSystemCfgEnt 4 } -- SFCS System Back Plane Table set up as a SYSTEM MIB -- This table contains the objects that pertain to the setup and -- configuration of the virtual switch. sfcsSysBPTable OBJECT IDENTIFIER ::= { sfcsSysBPCfg 1 } sfcsSysBPEnt OBJECT IDENTIFIER ::= { sfcsSysBPTable 1 } sfcsSysBPClkSelect OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This enables one of two backplane clocks from any slot. A valid entry is any number that correspond to a slot having a board supporting this mib. A write to this mib will fail if the board with the number selected is deriving its clock from the backplane. A value of 0 indicates that no board is driving the backplane." ::= { sfcsSysBPEnt 1 } -- From here forward, all objects represent the switch modules. -- SFCS Engine Group -- This group contains the objects that pertain to switching engines at -- a switch module, slot-instanced level. This group contains four sub-groups: -- configuration status, statistics, UPC Engine, and statistics engine. -- SFCS Engine Configuration Table -- This table contains the objects that pertain to the setup and -- configuration of a single SFCS module. sfcsConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the configuration and administrative information for each SFCS module. Essentially, a separate SFCS instance exists for each switch module. If SFCS is not configured on a module, than an entry will not exist." ::= { sfcsConfig 1 } sfcsConfigEntry OBJECT-TYPE SYNTAX SfcsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the SFCS configuration for the SFCS module." INDEX { sfcsConfigSlotIndex } ::= { sfcsConfigTable 1 } SfcsConfigEntry ::= SEQUENCE { sfcsConfigSlotIndex INTEGER, sfcsConfigAdminStatus INTEGER, sfcsConfigAdminReset INTEGER, sfcsConfigOperStatus INTEGER, sfcsConfigOperTime TimeTicks, sfcsConfigLastChange TimeTicks, sfcsConfigVersion INTEGER, sfcsConfigMibRev DisplayString, sfcsConfigSwitchHostPort INTEGER, sfcsConfigHostCtrlATMAddr OCTET STRING, sfcsConfigSwitchCapacity INTEGER, sfcsConfigMaxCnxEntries INTEGER, sfcsConfigMaxStatEntries INTEGER, sfcsConfigMaxUpcEntries INTEGER, sfcsConfigNumberANIMS INTEGER, sfcsConfigBwCapability INTEGER, sfcsConfigMasterClock1Source INTEGER, sfcsConfigMasterClock2Source INTEGER, sfcsConfigMasterClock1Standby INTEGER, sfcsConfigMasterClock2Standby INTEGER } sfcsConfigSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary index to the SFCS switch table. This identifies the chassis slot number for this switch module." ::= { sfcsConfigEntry 1 } sfcsConfigAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- startup the SFCS disabled(2), -- shutdown the SFCS other(3) -- none of the following } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SFCS switching services for this SFCS module. This controls the SFCS state at a module level. Regardless of the per-interface state of each SFCS switching interface and the state of active connections, writing the value disabled(2) will cause the SFCS to immediately shutdown. A gracefull shutdown will be attempted. enabled(1) -- startup the SFCS disabled(2) -- shutdown the SFCS other(3) -- none of the following" ::= { sfcsConfigEntry 2 } sfcsConfigAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets this SFCS module. Writing a value of reset(2) will force a soft restart of the SFCS without any graceful shutdown. Any active connections or services will be interrupted. other(1) -- none of the following reset(2) -- force a reset" ::= { sfcsConfigEntry 3 } sfcsConfigOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- running disabled(2), -- not running other(3), -- none of the following pending-disable(4), -- shut-down in progress pending-enable(5), -- start-up in progress invalid-config(6) -- not running,invalid config } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the SFCS module. enabled(1) -- running disabled(2) -- not running other(3) -- none of the following pending-disable(4) -- shut-down in progress pending-enable(5) -- start-up in progress invalid-config(6) -- not running,invalid config" ::= { sfcsConfigEntry 4 } sfcsConfigOperTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time (# of time ticks) that this SFCS module has been in its current operational state." ::= { sfcsConfigEntry 5 } sfcsConfigLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the last time a change was made to the configuration entry for this SFCS switch module." ::= { sfcsConfigEntry 6 } sfcsConfigVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the SFCS MIB for this switch module expressed as an integer." ::= { sfcsConfigEntry 7 } sfcsConfigMibRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates in textual format the current revision level of the Cabletron SFCS MIB for this switch module." ::= { sfcsConfigEntry 8 } sfcsConfigSwitchHostPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the switch port that is attached to the host." ::= { sfcsConfigEntry 9 } sfcsConfigHostCtrlATMAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the ATM address of the host. (SAR)" ::= { sfcsConfigEntry 10 } sfcsConfigSwitchCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the front panel bandwidth based on the hardware that is currently installed, in Mbps. (number of ports and the port type)" ::= { sfcsConfigEntry 11 } sfcsConfigMaxCnxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of connections which can be established on this switch module." ::= { sfcsConfigEntry 12 } sfcsConfigMaxStatEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of stats enabled VCs for this switch module." ::= { sfcsConfigEntry 13 } sfcsConfigMaxUpcEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum number of UPC enabled VCs for this switch module." ::= { sfcsConfigEntry 14 } sfcsConfigNumberANIMS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of ATM Network Inteface Modules currently configured on this switch module." ::= { sfcsConfigEntry 15 } sfcsConfigBwCapability OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total bandwidth capability for this switch engine expressed in Mbps." ::= { sfcsConfigEntry 16 } sfcsConfigMasterClock1Source OBJECT-TYPE SYNTAX INTEGER{ anim-one-clk(1), anim-two-clk(2), anim-three-clk(3), anim-four-clk(4), backplane-one(5), backplane-two(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the clocking source for MasterClock1 on each board. The write will fail if it is also currently the source of the backplane. The write will also fail if the board does not support backplane clocking." ::= { sfcsConfigEntry 17 } sfcsConfigMasterClock2Source OBJECT-TYPE SYNTAX INTEGER{ anim-one-clk(1), anim-two-clk(2), anim-three-clk(3), anim-four-clk(4), backplane-one(5), backplane-two(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the clocking source for MasterClock2 on each board. The write will fail if it is also currently the source of the backplane. The write will also fail if the board does not support backplane clocking." ::= { sfcsConfigEntry 18 } sfcsConfigMasterClock1Standby OBJECT-TYPE SYNTAX INTEGER{ anim-one-clk(1), anim-two-clk(2), anim-three-clk(3), anim-four-clk(4), backplane-one(5), backplane-two(6), none(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the clocking stand-by for MasterClock1 on each board. The write will fail if it is also currently the source of the backplane. The write will also fail if the board does not support backplane clocking. If this value is none(7) and an interrupt on the primary interface for MasterClock1 is received. MasterClock1 will switch to that anims local clock." ::= { sfcsConfigEntry 19 } sfcsConfigMasterClock2Standby OBJECT-TYPE SYNTAX INTEGER{ anim-one-clk(1), anim-two-clk(2), anim-three-clk(3), anim-four-clk(4), backplane-one(5), backplane-two(6), none(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the clocking stand-by for MasterClock2 on each board. The write will fail if it is also currently the source of the backplane. The write will also fail if the board does not support backplane clocking. If this value is none(7) and an interrupt on the primary interface for MasterClock1 is received. MasterClock1 will switch to that anims local clock." ::= { sfcsConfigEntry 20 } -- SFCS Status Table -- This table contains the objects that pertain to the operational status -- of a single SFCS module. sfcsStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the status information for each SFCS switch module." ::= { sfcsStatus 1 } sfcsStatusEntry OBJECT-TYPE SYNTAX SfcsStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the SFCS statistics for the SFCS instance." INDEX { sfcsStatusSlotIndex } ::= { sfcsStatusTable 1 } SfcsStatusEntry ::= SEQUENCE { sfcsStatusSlotIndex INTEGER, sfcsStatusTdmCellCount OCTET STRING, sfcsStatusTdmUtilization INTEGER, sfcsStatusCurrCnxEntries INTEGER, sfcsStatusCurrUPCEntries INTEGER, sfcsStatusCurrStatsEntries INTEGER, sfcsStatusCurrCtmAgent INTEGER } sfcsStatusSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary index to the SFCS switch table. This identifies the chassis slot number for this SFCS module." ::= { sfcsStatusEntry 1 } sfcsStatusTdmCellCount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of cells being transfered across the TDM for this switch module." ::= { sfcsStatusEntry 2 } sfcsStatusTdmUtilization OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the percentage TDM utilization for this switch module." ::= { sfcsStatusEntry 3 } sfcsStatusCurrCnxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current number of connection entries for this switch module." ::= { sfcsStatusEntry 4 } sfcsStatusCurrUPCEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current number of UPC entries for this switch module." ::= { sfcsStatusEntry 5 } sfcsStatusCurrStatsEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current number of statistics entries for this switch module." ::= { sfcsStatusEntry 6 } sfcsStatusCurrCtmAgent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current board number of the ctm agent for this switch module." ::= { sfcsStatusEntry 7 } -- SFCS UPC Engine Table -- This table contains the objects that pertain to UPC Engine -- monitoring and statistics of a single instance, slot number indexed -- SFCS module. sfcsUPCTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsUPCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Usage Parameter Control info for this SFCS module." ::= { sfcsUPCEngine 1 } sfcsUPCEntry OBJECT-TYPE SYNTAX SfcsUPCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the UPC data for the SFCS instance." INDEX { sfcsUPCSlotIndex } ::= { sfcsUPCTable 1 } SfcsUPCEntry ::= SEQUENCE { sfcsUPCSlotIndex INTEGER, sfcsUPCAdminStatus INTEGER, sfcsUPCOperStatus INTEGER, sfcsUPCReset INTEGER, sfcsUPCOperTime TimeTicks } sfcsUPCSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary index to the SFCS switch table. This identifies the slot number for this SFCS module." ::= { sfcsUPCEntry 1 } sfcsUPCAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SFCS module's UPC engine. enabled(1) disabled(2) other(3)" ::= { sfcsUPCEntry 2 } sfcsUPCOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational state of the SFCS module's UPC engine." ::= { sfcsUPCEntry 3 } sfcsUPCReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the UPC engine for this SFCS module. other(1) reset(2)" ::= { sfcsUPCEntry 4 } sfcsUPCOperTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time (# of time ticks) that the UPC engine has been active for this switch module." ::= { sfcsUPCEntry 5 } -- SFCS Statistics Engine Table -- This table contains the objects that pertain to Statistics Engine -- for a single SFCS module. sfcsStatsEngineTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsStatsEngineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information for the Statistics engine for a particular switch module." ::= { sfcsStatisticsEngine 1 } sfcsStatsEngineEntry OBJECT-TYPE SYNTAX SfcsStatsEngineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the statistics engine data for the SFCS module." INDEX { sfcsStatsEngineSlotIndex } ::= { sfcsStatsEngineTable 1 } SfcsStatsEngineEntry ::= SEQUENCE { sfcsStatsEngineSlotIndex INTEGER, sfcsStatsEngineAdminStatus INTEGER, sfcsStatsEngineOperStatus INTEGER, sfcsStatsEngineReset INTEGER, sfcsStatsEngineOperTime TimeTicks } sfcsStatsEngineSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary index to the SFCS stats engine table. This identifies the chassis slot number for this SFCS module." ::= { sfcsStatsEngineEntry 1 } sfcsStatsEngineAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SFCS switch statistics engine. Writing a value of enabled(1) causes these counters to become active for this SFCS switch instance. Writing a value of disabled(2) causes these counters to become inactive for this SFCS module. enabled(1) disabled(2) other(3)" ::= { sfcsStatsEngineEntry 2 } sfcsStatsEngineOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational state of the SFCS switch statistics engine for this switch module. enabled(1) disabled(2) other(3)" ::= { sfcsStatsEngineEntry 3 } sfcsStatsEngineReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the SFCS switch counters for this SFCS module. Writing a value of reset(2) resets the SFCS switch counters to 0 and causes sfcsStatsEngineOperTime to also be reset to 0. other(1) reset(2)" ::= { sfcsStatsEngineEntry 4 } sfcsStatsEngineOperTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time (# of time ticks) that the SFCS switch statistics have been active for this switch module." ::= { sfcsStatsEngineEntry 5 } -- SFCS Packet Discard Engine Table -- This table contains the objects that pertain to Packet Discard Engine -- for a single SFCS module. sfcsPacketDiscardEngineTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsPacketDiscardEngineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information for the Packet Discard engine for a particular switch module." ::= { sfcsPacketDiscardEngine 1 } sfcsPacketDiscardEngineEntry OBJECT-TYPE SYNTAX SfcsPacketDiscardEngineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the packet discard engine data for the SFCS module." INDEX { sfcsPacketDiscardEngineSlotIndex } ::= { sfcsPacketDiscardEngineTable 1 } SfcsPacketDiscardEngineEntry ::= SEQUENCE { sfcsPacketDiscardEngineSlotIndex INTEGER, sfcsPacketDiscardEngineAdminStatus INTEGER, sfcsPacketDiscardEngineOperStatus INTEGER, sfcsPacketDiscardEngineReset INTEGER, sfcsPacketDiscardEngineEPDPercentage INTEGER, sfcsPacketDiscardEngineOperTime TimeTicks } sfcsPacketDiscardEngineSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary index to the SFCS packet discard engine table. This identifies the chassis slot number for this SFCS module." ::= { sfcsPacketDiscardEngineEntry 1 } sfcsPacketDiscardEngineAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SFCS switch packet discard engine. Writing a value of enabled(1) causes these packet discard registers to become active for this SFCS switch instance. Writing a value of disabled(2) causes these packet discard registers to become inactive for this SFCS module. enabled(1) disabled(2) other(3)" ::= { sfcsPacketDiscardEngineEntry 2 } sfcsPacketDiscardEngineOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational state of the SFCS switch packet discard engine for this switch module. enabled(1) disabled(2) other(3)" ::= { sfcsPacketDiscardEngineEntry 3 } sfcsPacketDiscardEngineReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the SFCS switch registers for this SFCS module. Writing a value of reset(2) resets the SFCS switch packet discard registers to 0 and causes sfcsPacketDiscardEngineOperTime to also be reset to 0. other(1) reset(2)" ::= { sfcsPacketDiscardEngineEntry 4 } sfcsPacketDiscardEngineEPDPercentage OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Early Packet Discard threshold percentage for every port, and every priority on a single blade." ::= { sfcsPacketDiscardEngineEntry 5 } sfcsPacketDiscardEngineOperTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time (# of time ticks) that the SFCS switch packet discard engine has been active for this switch module." ::= { sfcsPacketDiscardEngineEntry 6 } -- SFCS Switching ANIM Group -- This group contains the managed objects used to setup and -- configure the SFCS ANIMS. This group contains two sub-groups: -- configuration status and statistics. -- SFCS ANIM Configuration Status Table -- This table contains the managed objects used to set-up and configure -- each SFCS ANIM. sfcsANIMConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsANIMConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the configuration information for each SFCS ANIM instance." ::= { sfcsANIMConfig 1 } sfcsANIMConfigEntry OBJECT-TYPE SYNTAX SfcsANIMConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the SFCS config info for the SFCS instance." INDEX { sfcsANIMConfigANIMIndex } ::= { sfcsANIMConfigTable 1 } SfcsANIMConfigEntry ::= SEQUENCE { sfcsANIMConfigANIMIndex INTEGER, sfcsANIMConfigAdminStatus INTEGER, sfcsANIMConfigOperStatus INTEGER, sfcsANIMConfigANIMType OBJECT IDENTIFIER, sfcsANIMConfigNumInterfaces INTEGER, sfcsANIMConfigLineRate INTEGER, sfcsANIMConfigToMB INTEGER, sfcsANIMConfigMBClockSelect INTEGER } sfcsANIMConfigANIMIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which ANIM we are dealing with. This reference is in the same format as MIB II's InterfaceIndex." ::= { sfcsANIMConfigEntry 1 } sfcsANIMConfigAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the SFCS switch ANIM. enabled(1) disabled(2) other(3)" ::= { sfcsANIMConfigEntry 2 } sfcsANIMConfigOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), other(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the operational state of the SFCS switch ANIM for this SFCS ANIM instance. enabled(1) disabled(2) other(3)" ::= { sfcsANIMConfigEntry 3 } sfcsANIMConfigANIMType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of physical interface for this ANIM. The types are described in ctron.oids" ::= { sfcsANIMConfigEntry 4 } sfcsANIMConfigNumInterfaces OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of operational interfaces for this ANIM." ::= { sfcsANIMConfigEntry 5 } sfcsANIMConfigLineRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the line rate per port for this ANIM in Mbps." ::= { sfcsANIMConfigEntry 6 } sfcsANIMConfigToMB OBJECT-TYPE SYNTAX INTEGER { local-anim-clock(1), port-one-clock(2), port-two-clock(3), port-three-clock(4), port-four-clock(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the ANIM clock source to board." ::= { sfcsANIMConfigEntry 7 } sfcsANIMConfigMBClockSelect OBJECT-TYPE SYNTAX INTEGER { master-clk-one(1), master-clk-two(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This indicates the ANIM clock source." ::= { sfcsANIMConfigEntry 8 } -- SFCS ANIM Stats Tables -- This table contains the managed objects used to keep track of transmit -- and receive counts and bandwidth for each SFCS ANIM. sfcsANIMStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsANIMStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the statistics information for each SFCS ANIM instance." ::= { sfcsANIMStatistics 1 } sfcsANIMStatsEntry OBJECT-TYPE SYNTAX SfcsANIMStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the SFCS statistics for the SFCS instance." INDEX { sfcsANIMStatsANIMIndex } ::= { sfcsANIMStatsTable 1 } SfcsANIMStatsEntry ::= SEQUENCE { sfcsANIMStatsANIMIndex INTEGER, sfcsANIMStatsRxCells OCTET STRING, sfcsANIMStatsTxCells OCTET STRING } sfcsANIMStatsANIMIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary index which specifies which ANIM instance we are dealing with. This index is formatted like MIB II's Interface Index." ::= { sfcsANIMStatsEntry 1 } sfcsANIMStatsRxCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells received from this ANIM's interfaces." ::= { sfcsANIMStatsEntry 2 } sfcsANIMStatsTxCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells transmitted from this ANIM's interfaces." ::= { sfcsANIMStatsEntry 3 } -- SFCS ANIM Pic Table -- This table contains the managed objects used to keep track of -- the PIC info for each SFCS ANIM. sfcsANIMPicTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsANIMPicEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the PIC information for each SFCS ANIM instance." ::= { sfcsANIMPic 1 } sfcsANIMPicEntry OBJECT-TYPE SYNTAX SfcsANIMPicEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the SFCS PIC info for the SFCS instance." INDEX { sfcsANIMPicIndex } ::= { sfcsANIMPicTable 1 } SfcsANIMPicEntry ::= SEQUENCE { sfcsANIMPicSlot INTEGER, sfcsANIMPicIndex INTEGER, sfcsANIMPicLocation OBJECT IDENTIFIER, sfcsANIMPicStatus INTEGER, sfcsANIMPicVersion DisplayString, sfcsANIMPicModuleType OBJECT IDENTIFIER, sfcsANIMPicMfgPN DisplayString, sfcsANIMPicMfgSN DisplayString, sfcsANIMPicMfgPartNumb DisplayString, sfcsANIMPicMfgSerialNumb DisplayString, sfcsANIMPicMfgReworkLocation DisplayString, sfcsANIMPicMfgMfgLocation DisplayString, sfcsANIMPicMfgDateCode DisplayString, sfcsANIMPicMfgRevisionCode DisplayString, sfcsANIMPicTLPN DisplayString, sfcsANIMPicTLSN DisplayString, sfcsANIMPicTLPartNumb DisplayString, sfcsANIMPicTLSerialNumb DisplayString, sfcsANIMPicTLReworkLocation DisplayString, sfcsANIMPicTLMfgLocation DisplayString, sfcsANIMPicTLDateCode DisplayString, sfcsANIMPicTLRevisionCode DisplayString, sfcsANIMPicTLPcbRevision DisplayString, sfcsANIMPicMacAddr OCTET STRING, sfcsANIMPicNumbRsvdAddrs INTEGER, sfcsANIMPicBoardLevelRevision DisplayString, sfcsANIMPicModuleTypeString DisplayString, sfcsANIMPicDcDcConverterType DisplayString, sfcsANIMPicDcDcConverterInputPower DisplayString, sfcsANIMPicSmb1PromVersion DisplayString } sfcsANIMPicSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specific slot which the module that realizes this PIC resides. If the PIC is associated with the chassis and not a specific module then this value will be 0." ::= { sfcsANIMPicEntry 1 } sfcsANIMPicIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely identifies the instance of a PIC in a particular slot." ::= { sfcsANIMPicEntry 2 } sfcsANIMPicLocation OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Defines location of the PIC chip. This takes on any of the encoding values defined below for backplane, module, daughter board, brim." ::= { sfcsANIMPicEntry 3 } sfcsANIMPicStatus OBJECT-TYPE SYNTAX INTEGER { other(1), present(2), notPresent(3), checkSum(4), error(5), limited(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Provides the status of the specific PIC chip. the values are defined as follows: other(1) - firmware can not determine status present(2) - PIC seems to be functional notPresent(3) - PIC not found but expected checkSum(4) - A check sum error occured error(5) - An undefined error condition exists. limited(6) - A limited PIC implementation only type code information is present." ::= { sfcsANIMPicEntry 4 } sfcsANIMPicVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "Reflects the version of the PIC implementation that this PIC conforms to. This has the format x.yy . If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 5 } sfcsANIMPicModuleType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the standard module type value as defined in ctron-oids." ::= { sfcsANIMPicEntry 6 } sfcsANIMPicMfgPN OBJECT-TYPE SYNTAX DisplayString (SIZE(9)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the manufacturing level part number of the module associated with this PIC. This information is encoded as follows: 7 Characters Part Number 2 Characters Rework Location. If any field of this object is non-existent, it will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 7 } sfcsANIMPicMfgSN OBJECT-TYPE SYNTAX DisplayString (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the manufacturing level serial number of the module associated with this PIC. This information is encoded as follows: 3 bytes - Date code (year/week) 4 bytes - Serial number 2 bytes - Manufacture location 3 bytes - Board level revision If any field of this object is non-existent, it will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 8 } sfcsANIMPicMfgPartNumb OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) ACCESS read-only STATUS mandatory DESCRIPTION "This object presents the part number portion of the ctPicMfgPN object. This object contains the same information however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 9 } sfcsANIMPicMfgSerialNumb OBJECT-TYPE SYNTAX DisplayString (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "This object presents the serial number portion of the ctPicMfgSN object. This object contains the same information however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 10 } sfcsANIMPicMfgReworkLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The 2 character code that defines the location this module was last reworked. This object contains the same information as presented in ctPicMfgPN object however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 11 } sfcsANIMPicMfgMfgLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The two character code that defines the location this module was manufactured at. This object contains the same information as presented in ctPicMfgSN object however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 12 } sfcsANIMPicMfgDateCode OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "The 3 byte date code field when this module was last reworked. This is in year/week format. This object contains the same information as presented in ctPicMfgSN object however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 13 } sfcsANIMPicMfgRevisionCode OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "The 3 character board level revision code field of this module. This object contains the same information as presented in ctPicMfgSN object however in a more human readable format. If non-existent, this object will be set to all blanks (ascii 32)." ::= { sfcsANIMPicEntry 14 } sfcsANIMPicTLPN OBJECT-TYPE SYNTAX DisplayString (SIZE(9)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the top level part number of the module associated with this PIC. This information is encoded as follows: 7 Characters Part Number 2 Characters Rework Location. If any field of this object is non-existent, it will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 15 } sfcsANIMPicTLSN OBJECT-TYPE SYNTAX DisplayString (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the top level serial number of the module associated with this PIC. This information is encoded as follows: 3 bytes - Date code (year/week) 4 bytes - Serial number 2 bytes - Manufacture location 3 bytes - Top level revision If any field of this object is non-existent, it will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 16 } sfcsANIMPicTLPartNumb OBJECT-TYPE SYNTAX DisplayString (SIZE(7)) ACCESS read-only STATUS mandatory DESCRIPTION "This object presents the part number portion of the ctPicTLPN object. This object contains the same information however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 17 } sfcsANIMPicTLSerialNumb OBJECT-TYPE SYNTAX DisplayString (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "This object presents the serial number portion of the ctPicTLSN object. This object contains the same information however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 18 } sfcsANIMPicTLReworkLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The 2 character code that defines the location this module was last reworked. This object contains the same information as presented in ctPicTLPN object however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 19 } sfcsANIMPicTLMfgLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The two character code that defines the location this module was manufactured at. This object contains the same information as presented in ctPicTLSN object however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 20 } sfcsANIMPicTLDateCode OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "The 3 byte date code field when this module was last reworked. This is in year/week format. This object contains the same information as presented in ctPicTLSN object however in a more human readable format. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 21 } sfcsANIMPicTLRevisionCode OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "The 3 character top level revision code field of this module. This object contains the same information as presented in ctPicTLSN object however in a more human readable format. If non-existent, this object will be set to all blanks (ascii 32)." ::= { sfcsANIMPicEntry 22 } sfcsANIMPicTLPcbRevision OBJECT-TYPE SYNTAX DisplayString (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "Defines the Cabletron revision of the art work for this module. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 23 } sfcsANIMPicMacAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..6)) ACCESS read-only STATUS mandatory DESCRIPTION "The base MAC address(ethernet format)assigned to the module. If this field is not used then it should have a value of a zero length string. If non-existent, this object will be set to all blanks(ascii 32)." ::= { sfcsANIMPicEntry 24 } sfcsANIMPicNumbRsvdAddrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of reserved MAC addresses starting at the address as defined in ctPicMacAddr. If no MAC addresses are reserved this object should have a value of 0." ::= { sfcsANIMPicEntry 25 } sfcsANIMPicBoardLevelRevision OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "Defines the Cabletron board level revision level code for this module. If non-existent, this object will be set to blanks (ascii 32)." ::= { sfcsANIMPicEntry 26 } sfcsANIMPicModuleTypeString OBJECT-TYPE SYNTAX DisplayString (SIZE(16)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the module associated with this PIC in a human readable format. If non-existent, this object will be set to blanks (ascii 32)." ::= { sfcsANIMPicEntry 27 } sfcsANIMPicDcDcConverterType OBJECT-TYPE SYNTAX DisplayString (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the voltage of the installed DCDC Converter input and output lines. If the Module does not contain a DCDC Converter this object will be set to blanks (ascii 32)." ::= { sfcsANIMPicEntry 28 } sfcsANIMPicDcDcConverterInputPower OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the maximum allowed input power for the DCDC input line. If the Module does not contain a DCDC Converter this object will be set to blanks (ascii 32)." ::= { sfcsANIMPicEntry 29 } sfcsANIMPicSmb1PromVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the current version of the SMB1 prom. If the Module does not contain an SMB1 prom this object will be set to blanks (ascii 32)." ::= { sfcsANIMPicEntry 30 } -- SFCS Switching Interface Group -- This group contains the managed objects used to setup and -- configure the SFCS interfaces for cell switching and statisics -- monitoring. This group contains two sub-groups: configuration -- and statistics. -- SFCS Interface Configuration Table -- This table contains the managed objects used to set-up and configure -- each SFCS switching interface. sfcsInterfaceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsInterfaceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the configuration information of each configured SFCS switch interface. If SFCS is not configured on a port, than an entry will not exist." ::= { sfcsInterfaceConfig 1 } sfcsInterfaceConfigEntry OBJECT-TYPE SYNTAX SfcsInterfaceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the SFCS configuration for the SFCS switch interface for which the entry exists." INDEX { sfcsInterfaceConfigInterfaceIndex } ::= { sfcsInterfaceConfigTable 1 } SfcsInterfaceConfigEntry ::= SEQUENCE { sfcsInterfaceConfigInterfaceIndex INTEGER, sfcsInterfaceConfigType INTEGER, sfcsInterfacePeakBufferUseage INTEGER, sfcsInterfaceConfigNumberOfQueues INTEGER, sfcsInterfaceConfigSigStackID INTEGER, sfcsInterfaceConfigClockingSource INTEGER } sfcsInterfaceConfigInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsInterfaceConfigEntry 1 } sfcsInterfaceConfigType OBJECT-TYPE SYNTAX INTEGER { other(1), access-port(2), network-port(3), host-mgmt-port(4), host-ctl-port(5) } ACCESS read-only STATUS deprecated DESCRIPTION "Sets the type of interface access attribute for the SFCS interfaces. Access ports allow single user or shared access and perform statisics and control; network ports are equivalent to trunk ports with no access control; host management port indicates the (virtual) port to which the (internal) management agent is attached; host control port indicates the port to redirect non-management packets. other(1) access-port(2) network-port(3) host-mgmt-port(4) host-ctl-port(5)" ::= { sfcsInterfaceConfigEntry 2 } sfcsInterfacePeakBufferUseage OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "An accumulated snap shot of the current peak queue depth for the configured buffer queues. This information is obtained from a read/reset register." ::= { sfcsInterfaceConfigEntry 3 } sfcsInterfaceConfigNumberOfQueues OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of priority queues configured on this interface." ::= { sfcsInterfaceConfigEntry 4 } sfcsInterfaceConfigSigStackID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the user signalling stack ID for this interface." ::= { sfcsInterfaceConfigEntry 5 } sfcsInterfaceConfigClockingSource OBJECT-TYPE SYNTAX INTEGER { local-anim-clock(1), mother-board-master-clock(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The interface clocking source." ::= { sfcsInterfaceConfigEntry 6 } -- SFCS Switching Interface Statistics Tables -- This table contains the objects that specify the packet and byte counters -- for each configured SFCS switching interface. sfcsInterfaceStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsInterfaceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the cell counts for each SFCS switch interface." ::= { sfcsInterfaceStatistics 1 } sfcsInterfaceStatsEntry OBJECT-TYPE SYNTAX SfcsInterfaceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Specifies the SFCS cell counts for the SFCS interface for which this entry exists." INDEX { sfcsInterfaceStatsInterfaceIndex } ::= { sfcsInterfaceStatsTable 1 } SfcsInterfaceStatsEntry ::= SEQUENCE { sfcsInterfaceStatsInterfaceIndex INTEGER, sfcsInterfaceStatsRxErrors OCTET STRING, sfcsInterfaceStatsVPILookupInvalidErrors OCTET STRING, sfcsInterfaceStatsRxCnxLookupInvalidErrors OCTET STRING, sfcsInterfaceStatsRxCellCnt OCTET STRING, sfcsInterfaceStatsTxCellCnt OCTET STRING, sfcsInterfaceStatsOverflowDropCellCnt OCTET STRING } sfcsInterfaceStatsInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsInterfaceStatsEntry 1 } sfcsInterfaceStatsRxErrors OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of receive path lookup invalid and out of range errors." ::= { sfcsInterfaceStatsEntry 2 } sfcsInterfaceStatsVPILookupInvalidErrors OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of VPI lookup invalid and out of range errors." ::= { sfcsInterfaceStatsEntry 3 } sfcsInterfaceStatsRxCnxLookupInvalidErrors OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of receive connection lookup invalid errors." ::= { sfcsInterfaceStatsEntry 4 } sfcsInterfaceStatsRxCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of receive cells on this interface." ::= { sfcsInterfaceStatsEntry 5 } sfcsInterfaceStatsTxCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of transmit cells on this interface." ::= { sfcsInterfaceStatsEntry 6 } sfcsInterfaceStatsOverflowDropCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells that were dropped due to queue overflows." ::= { sfcsInterfaceStatsEntry 7 } -- SFCS Switch Queue Group -- This group contains the managed objects for maintaining SFCS Queues. -- SFCS Queue Configuration Table sfcsQueueConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsQueueConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the configuration information for all queues on the SFCS." ::= { sfcsQueueConfig 1 } sfcsQueueConfigEntry OBJECT-TYPE SYNTAX SfcsQueueConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the queue information for the SFCS switch for which the entry exists." INDEX { sfcsQueueConfigInterfaceIndex, sfcsQueueConfigQueueIndex } ::= { sfcsQueueConfigTable 1 } SfcsQueueConfigEntry ::= SEQUENCE { sfcsQueueConfigInterfaceIndex INTEGER, sfcsQueueConfigQueueIndex INTEGER, sfcsQueueConfigQueueSize INTEGER, sfcsQueueConfigQueueBandwidth INTEGER, sfcsQueueConfigClpDropThreshold INTEGER, sfcsQueueConfigCongestionThreshold INTEGER, sfcsQueueConfigEFCILowThreshold INTEGER, sfcsQueueConfigRMThreshold INTEGER, sfcsQueueConfigEPDThreshold INTEGER } sfcsQueueConfigInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsQueueConfigEntry 1 } sfcsQueueConfigQueueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which transmit queue we are dealing with." ::= { sfcsQueueConfigEntry 2 } sfcsQueueConfigQueueSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the size of the transmit queue for this queue instance." ::= { sfcsQueueConfigEntry 3 } sfcsQueueConfigQueueBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the percentage of this interface's bandwidth utilized by this particular queue." ::= { sfcsQueueConfigEntry 4 } sfcsQueueConfigClpDropThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the queue level to start dropping CLP=1 cells for this queue. This level is expressed as the percentage of this queue's size." ::= { sfcsQueueConfigEntry 5 } sfcsQueueConfigCongestionThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the level to consider this queue congested. This level is expressed as the percentage of this queue's size." ::= { sfcsQueueConfigEntry 6 } sfcsQueueConfigEFCILowThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the lower threshold used for EFCI for this queue instance. This level is expressed as the percentage of this queue's size." ::= { sfcsQueueConfigEntry 7 } sfcsQueueConfigRMThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the remote management queue threshold expressed as a percentage of the queue's size. When this level is hit, a management message is sent to the sender notifying it to slow down." ::= { sfcsQueueConfigEntry 8 } sfcsQueueConfigEPDThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the Early Packet Discard threshold expressed as a percentage of the queue's size. When this level is exceeded the Transmit ASIC starts to drop all cells entering this queue." ::= { sfcsQueueConfigEntry 9 } -- SFCS Queue Stats Table sfcsQueueStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsQueueStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the statistics information for all queues on the SFCS." ::= { sfcsQueueStatistics 1 } sfcsQueueStatsEntry OBJECT-TYPE SYNTAX SfcsQueueStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the queue information for the SFCS switch for which the entry exists." INDEX { sfcsQueueStatsInterfaceIndex, sfcsQueueStatsQueue } ::= { sfcsQueueStatsTable 1 } SfcsQueueStatsEntry ::= SEQUENCE { sfcsQueueStatsInterfaceIndex INTEGER, sfcsQueueStatsQueue INTEGER, sfcsQueueStatsTxClpCellsDiscarded OCTET STRING, sfcsQueueStatsTxCellsDropped OCTET STRING, sfcsQueueStatsQueuePeakLevel INTEGER, sfcsQueueStatsTxCellCnt OCTET STRING } sfcsQueueStatsInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsQueueStatsEntry 1 } sfcsQueueStatsQueue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which queue we are dealing with." ::= { sfcsQueueStatsEntry 2 } sfcsQueueStatsTxClpCellsDiscarded OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells with CLP=1 that were discarded for this queue instance." ::= { sfcsQueueStatsEntry 3 } sfcsQueueStatsTxCellsDropped OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells that overflowed the buffer for this queue instance." ::= { sfcsQueueStatsEntry 4 } sfcsQueueStatsQueuePeakLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the peak level since last read for this queue instance." ::= { sfcsQueueStatsEntry 5 } sfcsQueueStatsTxCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the transmit cell count on a per queue basis. A value of zero indicates not available" ::= { sfcsQueueStatsEntry 6 } -- The SFCS Connection Group -- SFCS Switch Connection Config Table sfcsCnxCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsCnxCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the connection configuration information." ::= { sfcsConnectionConfig 1 } sfcsCnxCfgEntry OBJECT-TYPE SYNTAX SfcsCnxCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the connection configuration information for the SFCS switch connection instance." INDEX { sfcsCnxCfgCrossConnectIndex, sfcsCnxCfgCrossConnectLowIfIndex, sfcsCnxCfgCrossConnectLowVpi, sfcsCnxCfgCrossConnectLowVci, sfcsCnxCfgCrossConnectHighIfIndex, sfcsCnxCfgCrossConnectHighVpi, sfcsCnxCfgCrossConnectHighVci } ::= { sfcsCnxCfgTable 1 } SfcsCnxCfgEntry ::= SEQUENCE { sfcsCnxCfgCrossConnectIndex INTEGER, sfcsCnxCfgCrossConnectLowIfIndex INTEGER, sfcsCnxCfgCrossConnectLowVpi INTEGER, sfcsCnxCfgCrossConnectLowVci INTEGER, sfcsCnxCfgCrossConnectHighIfIndex INTEGER, sfcsCnxCfgCrossConnectHighVpi INTEGER, sfcsCnxCfgCrossConnectHighVci INTEGER, sfcsCnxCfgType INTEGER, sfcsCnxCfgTmType INTEGER, sfcsCnxCfgUPCEnable INTEGER, sfcsCnxCfgStatsEnable INTEGER, sfcsCnxCfgStatsTableCounterSizes INTEGER, sfcsCnxCfgOwner INTEGER } sfcsCnxCfgCrossConnectIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value to identify this cross-connect." ::= { sfcsCnxCfgEntry 1 } sfcsCnxCfgCrossConnectLowIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the low MIB II IfIndex value of the ATM interface port for this cross-connect." ::= { sfcsCnxCfgEntry 2 } sfcsCnxCfgCrossConnectLowVpi OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the low VPI value at the ATM interface associated with the cross-connect that is identified by sfcsCnxCfgCrossConnectIndex." ::= { sfcsCnxCfgEntry 3 } sfcsCnxCfgCrossConnectLowVci OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the low VCI value at the ATM interface associated with this cross-connect that is identified by sfcsCnxCfgCrossConnectIndex." ::= { sfcsCnxCfgEntry 4 } sfcsCnxCfgCrossConnectHighIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the high MIB II IfIndex value of the ATM interface port for this cross-connect." ::= { sfcsCnxCfgEntry 5 } sfcsCnxCfgCrossConnectHighVpi OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the high VPI value at the ATM interface associated with the cross-connect that is identified by sfcsCnxCfgCrossConnectIndex." ::= { sfcsCnxCfgEntry 6 } sfcsCnxCfgCrossConnectHighVci OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the high VCI value at the ATM interface associated with this cross-connect that is identified by sfcsCnxCfgCrossConnectIndex." ::= { sfcsCnxCfgEntry 7 } sfcsCnxCfgType OBJECT-TYPE SYNTAX INTEGER { point-to-point-vpl (1), point-to-mpoint-vpl (2), mpoint-to-mpoint-vpl (3), point-to-point-vcl (4), point-to-mpoint-vcl (5), mpoint-to-mpoint-vcl (6) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the connection type for this VC. point-to-point-vpl(1) point-to-mpoint-vpl(2) mpoint-to-mpoint-vpl(3) point-to-point-vcl(4) point-to-mpoint-vcl(5) mpoint-to-mpoint-vcl(6)" ::= { sfcsCnxCfgEntry 8 } sfcsCnxCfgTmType OBJECT-TYPE SYNTAX INTEGER { other (1), efci (2), er (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of traffic management used on this VC. other (1) efci (2) er (3)" ::= { sfcsCnxCfgEntry 9 } sfcsCnxCfgUPCEnable OBJECT-TYPE SYNTAX INTEGER { l-h-upc-enabled (1), l-h-tag-enabled (2), l-h-upc-tag-enabled (3), h-l-upc-enabled (4), l-h-upc-and-h-l-upc-enabled (5), l-h-Tag-and-h-l-upc-enabled (6), l-h-upc-tag-and-h-l-upc-enabled (7), h-l-tag-enabled (8), l-h-upc-and-h-l-tag-enabled (9), l-h-tag-and-h-l-tag-enabled (10), l-h-upc-tag-and-h-l-tag-enabled (11), h-l-upc-tag-enabled (12), l-h-upc-and-h-l-upc-tag-enabled (13), l-h-tag-and-h-l-upc-tag-enabled (14), l-h-upc-tag-and-h-l-upc-tag-enabled (15) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether or not UPC policing is enabled on this VC. A VC can be bi-directional or uni-directional. Due to this, the UPC bit is a masking based on directionality. Where direction is in terms of high interface (H) and low interface (L). (Where not specified, assume disabled.) L to H UPC enabled(1) L to H Tagging enabled(2) L to H UPC/Tagging enabled(3) H to L UPC enabled(4) L to H UPC enabled & H to L UPC enabled(5) L to H Tagging enabled & H to L UPC enabled(6) L to H UPC/Tagging enabled & H to L UPC enabled(7) H to L Tagging enabled(8) L to H UPC enabled & H to L Tagging enabled(9) L to H Tagging enabled & H to L Tagging enabled(10) L to H UPC/Tagging enabled & H to L Tagging enabled(11) H to L UPC/Tagging enabled(12) L to H UPC enabled & H to L UPC/Tagging enabled(13) L to H Tagging enabled and H to L UPC/Tagging enabled(14) L to H UPC/Tagging enabled & H to L UPC/Tagging enabled(15)" ::= { sfcsCnxCfgEntry 10 } sfcsCnxCfgStatsEnable OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), other (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether statistics will be kept on this VC. enabled(1) disabled(2) other(3)" ::= { sfcsCnxCfgEntry 11 } sfcsCnxCfgStatsTableCounterSizes OBJECT-TYPE SYNTAX INTEGER { thirtytwobittagcounter (1), thirtytwobitdropcounter (2), sixteenbiteachcounter (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the size of the drop counter for this VC. thirtytwobittagcounter (1) thirtytwobitdropcounter (2) sixteenbiteachcounter (3)" ::= { sfcsCnxCfgEntry 12 } sfcsCnxCfgOwner OBJECT-TYPE SYNTAX INTEGER { other (1), own (2), dontown (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the owner of this cross connect. other(1) own(2) dontown(3)" ::= { sfcsCnxCfgEntry 13 } -- SFCS Switch Connection Stats Table sfcsCnxStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsCnxStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the connection configuration information." ::= { sfcsConnectionStatistics 1 } sfcsCnxStatsEntry OBJECT-TYPE SYNTAX SfcsCnxStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the connection statistics information for the SFCS switch connection instance." INDEX { sfcsCnxStatsCrossConnectIndex, sfcsCnxStatsCrossConnectLowIfIndex, sfcsCnxStatsCrossConnectLowVpi, sfcsCnxStatsCrossConnectLowVci, sfcsCnxStatsCrossConnectHighIfIndex, sfcsCnxStatsCrossConnectHighVpi, sfcsCnxStatsCrossConnectHighVci } ::= { sfcsCnxStatsTable 1 } SfcsCnxStatsEntry ::= SEQUENCE { sfcsCnxStatsCrossConnectIndex INTEGER, sfcsCnxStatsCrossConnectLowIfIndex INTEGER, sfcsCnxStatsCrossConnectLowVpi INTEGER, sfcsCnxStatsCrossConnectLowVci INTEGER, sfcsCnxStatsCrossConnectHighIfIndex INTEGER, sfcsCnxStatsCrossConnectHighVpi INTEGER, sfcsCnxStatsCrossConnectHighVci INTEGER, sfcsCnxStatsLoToHiHTxCells OCTET STRING, sfcsCnxStatsLoToHiDroppedCells OCTET STRING, sfcsCnxStatsLoToHiTaggedCells OCTET STRING, sfcsCnxStatsHiToLoHTxCells OCTET STRING, sfcsCnxStatsHiToLoDroppedCells OCTET STRING, sfcsCnxStatsHiToLoTaggedCells OCTET STRING } sfcsCnxStatsCrossConnectIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value to identify this cross-connect." ::= { sfcsCnxStatsEntry 1 } sfcsCnxStatsCrossConnectLowIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the low MIB II IfIndex value of the ATM interface port for this cross-connect." ::= { sfcsCnxStatsEntry 2 } sfcsCnxStatsCrossConnectLowVpi OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the low VPI value at the ATM interface associated with the cross-connect that is identified by sfcsCnxStatsCrossConnectIndex." ::= { sfcsCnxStatsEntry 3 } sfcsCnxStatsCrossConnectLowVci OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the low VCI value at the ATM interface associated with this cross-connect that is identified by sfcsCnxStatsCrossConnectIndex." ::= { sfcsCnxStatsEntry 4 } sfcsCnxStatsCrossConnectHighIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the high MIB II IfIndex value of the ATM interface port for this cross-connect." ::= { sfcsCnxStatsEntry 5 } sfcsCnxStatsCrossConnectHighVpi OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the high VPI value at the ATM interface associated with the cross-connect that is identified by sfcsCnxStatsCrossConnectIndex." ::= { sfcsCnxStatsEntry 6 } sfcsCnxStatsCrossConnectHighVci OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is equal to the high VCI value at the ATM interface associated with this cross-connect that is identified by sfcsCnxStatsCrossConnectIndex." ::= { sfcsCnxStatsEntry 7 } sfcsCnxStatsLoToHiHTxCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the transmitted cell count for this connection. This entry specifies the count from the low port/vpi/vci to the high port/vpi/vci" ::= { sfcsCnxStatsEntry 8 } sfcsCnxStatsLoToHiDroppedCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the dropped cell count for this connection instance. This entry specifies the count from the low port/vpi/vci to the high port/vpi/vci." ::= { sfcsCnxStatsEntry 9 } sfcsCnxStatsLoToHiTaggedCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the tagged cell count for this connection instance. This entry specifies the count from the low port/vpi/vci to the high port/vpi/vci." ::= { sfcsCnxStatsEntry 10 } sfcsCnxStatsHiToLoHTxCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the transmitted cell count for this connection. This entry specifies the count from the high port/vpi/vci to the low port/vpi/vci" ::= { sfcsCnxStatsEntry 11 } sfcsCnxStatsHiToLoDroppedCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the dropped cell count for this connection instance. This entry specifies the count from the high port/vpi/vci to the low port/vpi/vci." ::= { sfcsCnxStatsEntry 12 } sfcsCnxStatsHiToLoTaggedCells OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the tagged cell count for this connection instance. This entry specifies the count from the high port/vpi/vci to the low port/vpi/vci." ::= { sfcsCnxStatsEntry 13 } -- SFCS Switch Connection Error Table sfcsCnxErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsCnxErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the connection error information supplied by the atmAPI mib." ::= { sfcsConnectionError 1 } sfcsCnxErrorEntry OBJECT-TYPE SYNTAX SfcsCnxErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of VCC connection request failures. This table is indexed the same way as the atmVcCrossConnectTable in the AToM mib." INDEX { atmVcCrossConnectIndex, atmVcCrossConnectLowIfIndex, atmVcCrossConnectLowVpi, atmVcCrossConnectLowVci, atmVcCrossConnectHighIfIndex, atmVcCrossConnectHighVpi, atmVcCrossConnectHighVci } -- AUGMENTS { sfcsCnxCfgEntry } ::= { sfcsCnxErrorTable 1 } SfcsCnxErrorEntry ::= SEQUENCE { sfcsCnxErrorCode OCTET STRING, sfcsCnxErrorTimeStamp TimeTicks, sfcsCnxErrorRowStatus INTEGER } sfcsCnxErrorCode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the error reason for failure of the connection setup. 01 fatal_error 02 moe_table_out_of_range 03 moe_mem_not_allocated 04 mem_fetch_double_reqst 05 lo_port_invalid 06 lo_port_locked 07 lo_vpi_invalid 08 lo_vci_invalid 09 hi_port_invalid 10 hi_port_locked 11 hi_vpi_invalid 12 hi_vci_invalid 13 trfc_desc_l2h_invalid 14 trfc_desc_h2l_invalid 15 ccid_invalid 16 ccid_not_assigned 17 atm_api_type_invalid 18 atm_api_verb_invalid 19 pt_to_pt_over_write_reqst 20 pt_reqst_over_mpt_conn 21 mask_table_full 22 duplicate_request 23 moe_table_out_of_memory 24 vpi0_non_term_reqst 25 hardware_out_of_heap 26 tx_conn_table_out_of_mem 27 tx_conn_table_time_out 28 ctm_communication_error 29 connection_table_out_of_sync 30 invalid_connection_entry 31 ctm_resource_alloc_error 32 front_panel_bandwidth_alloc_error 33 ccid_in_use" ::= { sfcsCnxErrorEntry 1 } sfcsCnxErrorTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of the sysUpTime when this connection request failed. We will support this field only if the element management uses this table." ::= { sfcsCnxErrorEntry 2 } sfcsCnxErrorRowStatus OBJECT-TYPE SYNTAX INTEGER { other (1), inactive (2), active (3), delete (4) } ACCESS read-write STATUS mandatory DESCRIPTION "The administrative control of this entry. The owner could delete this entry after reading it, to prevent this table from growing too big. other (1) inactive (2) active (3) delete (4)" ::= { sfcsCnxErrorEntry 3 } -- The SFCS connection API Group sfcsCnxAPIEntry OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION " The connection API leaf provides a method for contool for creating PVCs. This always returns a value of 0. " ::= { sfcsConnectionAPI 1 } -- The SFCS Switch CTM Group sfcsCTMInterfaceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsCTMInterfaceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the configuration information of each configured SHEMP interface. If SFCS is not configured on a port, than an entry will not exist." ::= { sfcsCTMInterfaceConfig 1 } sfcsCTMInterfaceConfigEntry OBJECT-TYPE SYNTAX SfcsCTMInterfaceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the SFCS configuration for the SFCS switch interface for which the entry exists." INDEX { sfcsCTMInterfaceConfigInterfaceIndex } ::= { sfcsCTMInterfaceConfigTable 1 } SfcsCTMInterfaceConfigEntry ::= SEQUENCE { sfcsCTMInterfaceConfigInterfaceIndex INTEGER, sfcsCTMInterfaceConfigType INTEGER, sfcsCTMInterfacePeakBufferUseage INTEGER, sfcsCTMInterfaceConfigNumberOfQueues INTEGER, sfcsCTMInterfaceConfigSigStackID INTEGER, sfcsCTMInterfaceConfigClocking INTEGER, sfcsCTMInterfaceConfigNextVPI INTEGER, sfcsCTMInterfaceConfigNextVCI INTEGER } sfcsCTMInterfaceConfigInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsCTMInterfaceConfigEntry 1 } sfcsCTMInterfaceConfigType OBJECT-TYPE SYNTAX INTEGER { other(1), access-port(2), network-port(3), host-mgmt-port(4), host-ctl-port(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Sets the type of interface access attribute for the SFCS interfaces. Access ports allow single user or shared access and perform statisics and control; network ports are equivalent to trunk ports with no access control; host management port indicates the (virtual) port to which the (internal) management agent is attached; host control port indicates the port to redirect non-management packets. other(1), access-port(2), network-port(3), host-mgmt-port(4), host-ctl-port(5) " ::= { sfcsCTMInterfaceConfigEntry 2 } sfcsCTMInterfacePeakBufferUseage OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells in transmit buffer memory." ::= { sfcsCTMInterfaceConfigEntry 3 } sfcsCTMInterfaceConfigNumberOfQueues OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of priority queues configured on this interface." ::= { sfcsCTMInterfaceConfigEntry 4 } sfcsCTMInterfaceConfigSigStackID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the user signalling stack ID for this interface." ::= { sfcsCTMInterfaceConfigEntry 5 } sfcsCTMInterfaceConfigClocking OBJECT-TYPE SYNTAX INTEGER { generated-transmit-clock(1), channel-recovered-clock(2), system-master-clock(3), not-supported(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The anim clocking source. one - use the generated-transmit-clock two - use the channel-recovered-clock three - use the system-master-clock four - option not supported by this interface" ::= { sfcsCTMInterfaceConfigEntry 6 } sfcsCTMInterfaceConfigNextVPI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the next vpi for this interface." ::= { sfcsCTMInterfaceConfigEntry 7 } sfcsCTMInterfaceConfigNextVCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the next vci for this interface." ::= { sfcsCTMInterfaceConfigEntry 8 } -- SFCS SHEMP Interface Statistics Tables -- This table contains the objects that specify the packet and byte counters -- for each configured SFCS switching interface. sfcsCTMInterfaceStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsCTMInterfaceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the cell counts for each SFCS switch interface." ::= { sfcsCTMInterfaceStatistics 1 } sfcsCTMInterfaceStatsEntry OBJECT-TYPE SYNTAX SfcsCTMInterfaceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Specifies the SFCS cell counts for the SFCS interface for which this entry exists." INDEX { sfcsCTMInterfaceStatsInterfaceIndex } ::= { sfcsCTMInterfaceStatsTable 1 } SfcsCTMInterfaceStatsEntry ::= SEQUENCE { sfcsCTMInterfaceStatsInterfaceIndex INTEGER, sfcsCTMInterfaceStatsRxErrors OCTET STRING, sfcsCTMInterfaceStatsVPILookupInvalidErrors OCTET STRING, sfcsCTMInterfaceStatsRxCnxLookupInvalidErrors OCTET STRING, sfcsCTMInterfaceStatsRxCellCnt OCTET STRING, sfcsCTMInterfaceStatsTxCellCnt OCTET STRING, sfcsCTMInterfaceStatsOverflowDropCellCnt OCTET STRING } sfcsCTMInterfaceStatsInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsCTMInterfaceStatsEntry 1 } sfcsCTMInterfaceStatsRxErrors OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of receive path lookup invalid and out of range errors." ::= { sfcsCTMInterfaceStatsEntry 2 } sfcsCTMInterfaceStatsVPILookupInvalidErrors OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of VPI lookup invalid and out of range errors." ::= { sfcsCTMInterfaceStatsEntry 3 } sfcsCTMInterfaceStatsRxCnxLookupInvalidErrors OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of receive connection lookup invalid errors." ::= { sfcsCTMInterfaceStatsEntry 4 } sfcsCTMInterfaceStatsRxCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of receive cells on this interface." ::= { sfcsCTMInterfaceStatsEntry 7 } sfcsCTMInterfaceStatsTxCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of transmit cells on this interface." ::= { sfcsCTMInterfaceStatsEntry 8 } sfcsCTMInterfaceStatsOverflowDropCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells that were dropped due to queue overflows." ::= { sfcsCTMInterfaceStatsEntry 9 } -- SFCS SHEMP Queue Group -- This group contains the managed objects for maintaining SFCS Shemp Queues. -- SFCS Shemp Queue Configuration Table sfcsCTMQueueConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsCTMQueueConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the configuration information for all queues on the SFCS." ::= { sfcsCTMQueueConfig 1 } sfcsCTMQueueConfigEntry OBJECT-TYPE SYNTAX SfcsCTMQueueConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the queue information for the SFCS switch for which the entry exists." INDEX { sfcsCTMQueueConfigInterfaceIndex, sfcsQueueConfigQueueIndex } ::= { sfcsCTMQueueConfigTable 1 } SfcsCTMQueueConfigEntry ::= SEQUENCE { sfcsCTMQueueConfigInterfaceIndex INTEGER, sfcsCTMQueueConfigQueueIndex INTEGER, sfcsCTMQueueConfigQueueSize INTEGER, sfcsCTMQueueConfigQueueBandwidth INTEGER, sfcsCTMQueueConfigClpDropThreshold INTEGER, sfcsCTMQueueConfigCongestionThreshold INTEGER, sfcsCTMQueueConfigEFCILowThreshold INTEGER, sfcsCTMQueueConfigRMThreshold INTEGER } sfcsCTMQueueConfigInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsCTMQueueConfigEntry 1 } sfcsCTMQueueConfigQueueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which transmit queue we are dealing with." ::= { sfcsCTMQueueConfigEntry 2 } sfcsCTMQueueConfigQueueSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the size of the transmit queue for this queue instance." ::= { sfcsCTMQueueConfigEntry 3 } sfcsCTMQueueConfigQueueBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the percentage of this interface's bandwidth utilized by this particular queue." ::= { sfcsCTMQueueConfigEntry 4 } sfcsCTMQueueConfigClpDropThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the queue level to start dropping CLP=1 cells for this queue. This level is expressed as the percentage of this queue's size." ::= { sfcsCTMQueueConfigEntry 5 } sfcsCTMQueueConfigCongestionThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the level to consider this queue congested. This level is expressed as the percentage of this queue's size." ::= { sfcsCTMQueueConfigEntry 6 } sfcsCTMQueueConfigEFCILowThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the lower threshold used for EFCI for this queue instance. This level is expressed as the percentage of this queue's size." ::= { sfcsCTMQueueConfigEntry 7 } sfcsCTMQueueConfigRMThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the remote management queue threshold expressed as a percentage of the queue's size. When this level is hit, a management message is sent to the sender notifying it to slow down." ::= { sfcsCTMQueueConfigEntry 8 } -- SFCS Shemp Queue Stats Table sfcsCTMQueueStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsCTMQueueStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the statistics information for all queues on the SFCS." ::= { sfcsCTMQueueStatistics 1 } sfcsCTMQueueStatsEntry OBJECT-TYPE SYNTAX SfcsCTMQueueStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the queue information for the SFCS switch for which the entry exists." INDEX { sfcsCTMQueueStatsInterfaceIndex, sfcsQueueStatsQueue } ::= { sfcsCTMQueueStatsTable 1 } SfcsCTMQueueStatsEntry ::= SEQUENCE { sfcsCTMQueueStatsInterfaceIndex INTEGER, sfcsCTMQueueStatsQueue INTEGER, sfcsCTMQueueStatsTxClpCellsDiscarded OCTET STRING, sfcsCTMQueueStatsTxCellsDropped OCTET STRING, sfcsCTMQueueStatsQueuePeakLevel INTEGER, sfcsCTMQueueStatsTxCellCnt OCTET STRING } sfcsCTMQueueStatsInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which interface we are dealing with." ::= { sfcsCTMQueueStatsEntry 1 } sfcsCTMQueueStatsQueue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index which specifies which queue we are dealing with." ::= { sfcsCTMQueueStatsEntry 2 } sfcsCTMQueueStatsTxClpCellsDiscarded OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells with CLP=1 that were discarded for this queue instance." ::= { sfcsCTMQueueStatsEntry 3 } sfcsCTMQueueStatsTxCellsDropped OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of cells that overflowed the buffer for this queue instance." ::= { sfcsCTMQueueStatsEntry 4 } sfcsCTMQueueStatsQueuePeakLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the peak level since last read for this queue instance." ::= { sfcsCTMQueueStatsEntry 5 } sfcsCTMQueueStatsTxCellCnt OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the transmit cell count on a per queue basis. A value of zero indicates not available" ::= { sfcsCTMQueueStatsEntry 6 } -- The SFCS Switch Host Group -- The SFCS Switch UniMux Group -- SFCS Switch Bandwidth Management Group -- This group contains the managed objects and functions used to setup and -- configure the SFCS Bandwidth Manager. This group contains four sub-groups -- Nim Tables, Port Tables, Bandwidth Pool elements and Buffer Tables. -- SFCS ANIM Bandwidth Management Nim Table -- This table contains contains information about the administration status of the Nim. -- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -- ### Nim Information sfcsBwNimsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsBwNimsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Nim Oid and the Nim Administrative Status reading functions." ::= { sfcsBwNims 1 } sfcsBwNimsEntry OBJECT-TYPE SYNTAX SfcsBwNimsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a Nim Oid and the Nim Administrative Status." INDEX { sfcsBwNimsIndex } ::= { sfcsBwNimsTable 1 } SfcsBwNimsEntry ::= SEQUENCE { sfcsBwNimsIndex INTEGER, sfcsBwNimsAdminStatus INTEGER, sfcsBWNimsBuffCount INTEGER, sfcsBWNimsPortCount INTEGER, sfcsBWNimsPrioCount INTEGER } -- ### Nim Defs sfcsBwNimsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which NIM we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBwNimsEntry 1 } sfcsBwNimsAdminStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the administrative status of this Nim. 10 - Active 20 - Inactive " ::= { sfcsBwNimsEntry 2 } sfcsBWNimsBuffCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit buffers for this NIM" ::= { sfcsBwNimsEntry 3 } sfcsBWNimsPortCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of ports for this NIM" ::= { sfcsBwNimsEntry 4 } sfcsBWNimsPrioCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of priority queues for this NIM" ::= { sfcsBwNimsEntry 5 } -- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -- ### Port Information sfcsBwPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsBwPortsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Port Oid, Port Administrative Status and the forward/reverse physical bandwidth reading functions." ::= { sfcsBwPorts 1 } sfcsBwPortsEntry OBJECT-TYPE SYNTAX SfcsBwPortsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the Port Oid, Port Administrative Status and the forward/reverse physical bandwidth." INDEX { sfcsBwPortsIndex } ::= { sfcsBwPortsTable 1 } SfcsBwPortsEntry ::= SEQUENCE { sfcsBwPortsIndex INTEGER, sfcsBwPortsAdminStatus INTEGER, sfcsBwPortsPhysBwFwd INTEGER, sfcsBwPortsPhysBwRev INTEGER, sfcsBwPortsZone INTEGER, sfcsBwPortsMetric INTEGER } -- #Ports Defs sfcsBwPortsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which Port we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBwPortsEntry 1 } sfcsBwPortsAdminStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the administrative status of this Port. 10 - Active 20 - Inactive " ::= { sfcsBwPortsEntry 2 } sfcsBwPortsPhysBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the forward physical bandwidth of the port in cells/sec." ::= { sfcsBwPortsEntry 3 } sfcsBwPortsPhysBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the reverse physical bandwidth of the port in cells/sec." ::= { sfcsBwPortsEntry 4 } sfcsBwPortsZone OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The range of the current bw operational point for this port. If a value has never been set the value will be -1." ::= { sfcsBwPortsEntry 5 } sfcsBwPortsMetric OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current bw operational point for this port. If a value has never been set the value will be -1." ::= { sfcsBwPortsEntry 6 } -- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -- ### Bandwidth Pool Limits Information sfcsBwPortPoolLimitsTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsBwPortPoolLimitsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains " ::= { sfcsBwPortPools 1 } sfcsBwPortPoolLimitsEntry OBJECT-TYPE SYNTAX SfcsBwPortPoolLimitsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains " INDEX { sfcsBwPortPoolLimitsIndex, sfcsBwPortPoolLimitsPoolIndex } ::= { sfcsBwPortPoolLimitsTable 1 } SfcsBwPortPoolLimitsEntry ::= SEQUENCE { sfcsBwPortPoolLimitsIndex INTEGER, sfcsBwPortPoolLimitsPoolIndex INTEGER, sfcsBwPortPoolLimitsMaxAllocBwFwd INTEGER, sfcsBwPortPoolLimitsMaxAllocBwRev INTEGER, sfcsBwPortPoolLimitsBwAllocStrat INTEGER, sfcsBwPortPoolLimitsBwConstant INTEGER, sfcsBwPortPoolLimitsCBRLimitFwd INTEGER, sfcsBwPortPoolLimitsCBRLimitRev INTEGER, sfcsBwPortPoolLimitsABRLimitFwd INTEGER, sfcsBwPortPoolLimitsABRLimitRev INTEGER, sfcsBwPortPoolLimitsVBRLimitFwd INTEGER, sfcsBwPortPoolLimitsVBRLimitRev INTEGER, sfcsBwPortPoolLimitsUBRLimitFwd INTEGER, sfcsBwPortPoolLimitsUBRLimitRev INTEGER, sfcsBwPortPoolLimitsUBRConnLimitFwd INTEGER, sfcsBwPortPoolLimitsUBRConnLimitRev INTEGER } -- # Limit Definitions sfcsBwPortPoolLimitsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which Port we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBwPortPoolLimitsEntry 1 } sfcsBwPortPoolLimitsPoolIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which Pool within Port we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBwPortPoolLimitsEntry 2 } sfcsBwPortPoolLimitsMaxAllocBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Upper Limit for BW to be allocated forward direction. It is defaulted to the physical BW and is set by administrative action. Can't be set to a value greater than physical BW" ::= { sfcsBwPortPoolLimitsEntry 3 } sfcsBwPortPoolLimitsMaxAllocBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Upper Limit for BW to be allocated reverse direction. It is defaulted to the physical BW and is set by administrative action. Can't be set to a value greater than physical BW" ::= { sfcsBwPortPoolLimitsEntry 4 } sfcsBwPortPoolLimitsBwAllocStrat OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Determines which of 3 sets of formulas will be used for computing the amount of variable bandwidth to be allocated. Conservative allocates the full amount of variable bandwidth, Moderate allocates approximately half of the variable bandwidth, Liberal supports very aggressive allocation and should only be used with caution. Conservative is the default." ::= { sfcsBwPortPoolLimitsEntry 5 } sfcsBwPortPoolLimitsBwConstant OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in formulas for computing the amount of variable bandwidth to be allocated. Valid values are 1-255 which is the numerator of a fraction whose fixed denominator is 256. Thus the value 255 is really 255/256 the most conservative value; the value 1 is really 1/256 the most liberal value; the value 128 is really 128/256 or 50%. The default is 50%." ::= { sfcsBwPortPoolLimitsEntry 6 } sfcsBwPortPoolLimitsCBRLimitFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to CBR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolLimitsEntry 7 } sfcsBwPortPoolLimitsCBRLimitRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to CBR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolLimitsEntry 8 } sfcsBwPortPoolLimitsABRLimitFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to ABR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolLimitsEntry 9 } sfcsBwPortPoolLimitsABRLimitRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to ABR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolLimitsEntry 10 } sfcsBwPortPoolLimitsVBRLimitFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to VBR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.) WARNING - Setting this limit to an arbitrarily low value may cause the switch to become inoperable as an SVC switch. PNNI establishes VBR connections for switch to switch communications. If an arbitrarily low limit is established, it may preclude PNNI inter-switch operability." ::= { sfcsBwPortPoolLimitsEntry 11 } sfcsBwPortPoolLimitsVBRLimitRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to VBR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.) WARNING - Setting this limit to an arbitrarily low value may cause the switch to become inoperable as an SVC switch. PNNI establishes VBR connections for switch to switch communications. If an arbitrarily low limit is established, it may preclude PNNI inter-switch operability." ::= { sfcsBwPortPoolLimitsEntry 12 } sfcsBwPortPoolLimitsUBRLimitFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to UBR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.) WARNING - Setting this limit to an arbitrarily low value may cause the switch to become inoperable as an SVC switch. Many internal management functions use UBR connections to establish connections with neighboring switches for keep alive and discovery functions. If an arbitrarily low limit is established, it may preclude SVC inter-switch operability." ::= { sfcsBwPortPoolLimitsEntry 13 } sfcsBwPortPoolLimitsUBRLimitRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A ratio used in allocating the allocatable bandwidth among the various Service classes. This value is the amount of the overall allocatable bw that can be allocated to UBR. The values are 1-255. For a more detailed description of value useage see sfcsBwPortPoolLimitsBwConstant. Total of all service classes for a given direction should not exceed 256. (If it has never been set, the value will be -1.) WARNING - Setting this limit to an arbitrarily low value may cause the switch to become inoperable as an SVC switch. Many internal management functions use UBR connections to establish connections with neighboring switches for keep alive and discovery functions. If an arbitrarily low limit is established, it may preclude SVC inter-switch operability." ::= { sfcsBwPortPoolLimitsEntry 14 } sfcsBwPortPoolLimitsUBRConnLimitFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A Limit to the number of UBR connections which can be established through this port. The limit applies to both user connections and management connections. The default is no limit. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolLimitsEntry 15 } sfcsBwPortPoolLimitsUBRConnLimitRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " A Limit to the number of UBR connections which can be established through this port. The limit applies to both user connections and management connections. The default is no limit. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolLimitsEntry 16 } -- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -- ### Bandwidth Pool Statistical Information sfcsBwPortPoolStatTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsBwPortPoolStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains " ::= { sfcsBwPortPools 2 } sfcsBwPortPoolStatEntry OBJECT-TYPE SYNTAX SfcsBwPortPoolStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains " INDEX { sfcsBwPortPoolStatsIndex, sfcsBwPortPoolStatsPoolIndex } ::= { sfcsBwPortPoolStatTable 1 } SfcsBwPortPoolStatEntry ::= SEQUENCE { sfcsBwPortPoolStatsIndex INTEGER, sfcsBwPortPoolStatsPoolIndex INTEGER, sfcsBwPortPoolStatConnCntFwd INTEGER, sfcsBwPortPoolStatConnCntRev INTEGER, sfcsBwPortPoolStatAllocBwFwd INTEGER, sfcsBwPortPoolStatAllocBwRev INTEGER, sfcsBwPortPoolStatAvailBwFwd INTEGER, sfcsBwPortPoolStatAvailBwRev INTEGER, sfcsBwPortPoolStatPeakBwFwd INTEGER, sfcsBwPortPoolStatPeakBwRev INTEGER, sfcsBwPortPoolStatRejConnFwd INTEGER, sfcsBwPortPoolStatRejConnRev INTEGER, sfcsBwPortPoolStatPrevAdverMAXCRFwd INTEGER, sfcsBwPortPoolStatPrevAdverMAXCRRev INTEGER, sfcsBwPortPoolStatPrevAdverAvailCRFwd INTEGER, sfcsBwPortPoolStatPrevAdverAvailCRRev INTEGER, sfcsBwPortPoolStatCBRConnCntFwd INTEGER, sfcsBwPortPoolStatCBRConnCntRev INTEGER, sfcsBwPortPoolStatCBRConnRejFwd INTEGER, sfcsBwPortPoolStatCBRConnRejRev INTEGER, sfcsBwPortPoolStatCBRAllocBwFwd INTEGER, sfcsBwPortPoolStatCBRAllocBwRev INTEGER, sfcsBwPortPoolStatCBRAggPCRFwd INTEGER, sfcsBwPortPoolStatCBRAggPCRRev INTEGER, sfcsBwPortPoolStatCBRPrevAdverMAXCTD INTEGER, sfcsBwPortPoolStatCBRPrevAdverCDV INTEGER, sfcsBwPortPoolStatABRConnCntFwd INTEGER, sfcsBwPortPoolStatABRConnCntRev INTEGER, sfcsBwPortPoolStatABRConnRejFwd INTEGER, sfcsBwPortPoolStatABRConnRejRev INTEGER, sfcsBwPortPoolStatABRAllocBwFwd INTEGER, sfcsBwPortPoolStatABRAllocBwRev INTEGER, sfcsBwPortPoolStatABRAggPCRFwd INTEGER, sfcsBwPortPoolStatABRAggPCRRev INTEGER, sfcsBwPortPoolStatABRPrevAdverMAXCTD INTEGER, sfcsBwPortPoolStatABRPrevAdverCDV INTEGER, sfcsBwPortPoolStatVBRConnCntFwd INTEGER, sfcsBwPortPoolStatVBRConnCntRev INTEGER, sfcsBwPortPoolStatVBRConnRejFwd INTEGER, sfcsBwPortPoolStatVBRConnRejRev INTEGER, sfcsBwPortPoolStatVBRAllocBwFwd INTEGER, sfcsBwPortPoolStatVBRAllocBwRev INTEGER, sfcsBwPortPoolStatVBRAggPCRFwd INTEGER, sfcsBwPortPoolStatVBRAggPCRRev INTEGER, sfcsBwPortPoolStatVBRPrevAdverMAXCTD INTEGER, sfcsBwPortPoolStatVBRPrevAdverCDV INTEGER, sfcsBwPortPoolStatUBRConnCntFwd INTEGER, sfcsBwPortPoolStatUBRConnCntRev INTEGER, sfcsBwPortPoolStatUBRConnRejFwd INTEGER, sfcsBwPortPoolStatUBRConnRejRev INTEGER, sfcsBwPortPoolStatUBRAllocBwFwd INTEGER, sfcsBwPortPoolStatUBRAllocBwRev INTEGER, sfcsBwPortPoolStatUBRAggPCRFwd INTEGER, sfcsBwPortPoolStatUBRAggPCRRev INTEGER, sfcsBwPortPoolStatUBRPrevAdverMAXCTD INTEGER, sfcsBwPortPoolStatUBRPrevAdverCDV INTEGER } sfcsBwPortPoolStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which Port we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBwPortPoolStatEntry 1 } sfcsBwPortPoolStatsPoolIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which Pool within Port we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBwPortPoolStatEntry 2 } sfcsBwPortPoolStatConnCntFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The current total number of calls in the forward direction." ::= { sfcsBwPortPoolStatEntry 3 } sfcsBwPortPoolStatConnCntRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The current total number of calls in the reverse direction." ::= { sfcsBwPortPoolStatEntry 4 } sfcsBwPortPoolStatAllocBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The current amount of allocated Bw in the forward direction." ::= { sfcsBwPortPoolStatEntry 5 } sfcsBwPortPoolStatAllocBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The current amount of allocated Bw in the reverse direction." ::= { sfcsBwPortPoolStatEntry 6 } sfcsBwPortPoolStatAvailBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The current amount of available Bw in the forward direction." ::= { sfcsBwPortPoolStatEntry 7 } sfcsBwPortPoolStatAvailBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The current amount of available Bw in the reverse direction." ::= { sfcsBwPortPoolStatEntry 8 } sfcsBwPortPoolStatPeakBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The peak amount of allocated Bw in the forward direction since the port was initialized OR the switch was reset." ::= { sfcsBwPortPoolStatEntry 9 } sfcsBwPortPoolStatPeakBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The peak amount of allocated Bw in the reverse direction since the port was initialized OR the switch was reset." ::= { sfcsBwPortPoolStatEntry 10 } sfcsBwPortPoolStatRejConnFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of connections which were rejected because of insufficient forward bandwidth since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 11 } sfcsBwPortPoolStatRejConnRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of connections which were rejected because of insufficient reverse bandwidth since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 12 } sfcsBwPortPoolStatPrevAdverMAXCRFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of physical forward BW reported to PNNI in the latest reporting period." ::= { sfcsBwPortPoolStatEntry 13 } sfcsBwPortPoolStatPrevAdverMAXCRRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of physical reverse BW reported to PNNI in the latest reporting period." ::= { sfcsBwPortPoolStatEntry 14 } sfcsBwPortPoolStatPrevAdverAvailCRFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of avail forward BW reported to PNNI in the latest reporting period." ::= { sfcsBwPortPoolStatEntry 15 } sfcsBwPortPoolStatPrevAdverAvailCRRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of avail reverse BW reported to PNNI in the latest reporting period." ::= { sfcsBwPortPoolStatEntry 16 } -- # CBR Info sfcsBwPortPoolStatCBRConnCntFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established CBR connections for the forward direction." ::= { sfcsBwPortPoolStatEntry 17 } sfcsBwPortPoolStatCBRConnCntRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established CBR connections for the reverse direction." ::= { sfcsBwPortPoolStatEntry 18 } sfcsBwPortPoolStatCBRConnRejFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of CBR forward connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 19 } sfcsBwPortPoolStatCBRConnRejRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of CBR reverse connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 20 } sfcsBwPortPoolStatCBRAllocBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of forward allocated Bw that is CBR service class." ::= { sfcsBwPortPoolStatEntry 21 } sfcsBwPortPoolStatCBRAllocBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of reverse allocated Bw that is CBR service class." ::= { sfcsBwPortPoolStatEntry 22 } sfcsBwPortPoolStatCBRAggPCRFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated forward PCR for all established CBR connections." ::= { sfcsBwPortPoolStatEntry 23 } sfcsBwPortPoolStatCBRAggPCRRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated reverse PCR for all established CBR connections." ::= { sfcsBwPortPoolStatEntry 24 } sfcsBwPortPoolStatCBRPrevAdverMAXCTD OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The maxCTD for the forward direction reported to PNNI for the last update period for CBR service class." ::= { sfcsBwPortPoolStatEntry 25 } sfcsBwPortPoolStatCBRPrevAdverCDV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The CDV for the forward direction reported to PNNI for the last update period for CBR service class." ::= { sfcsBwPortPoolStatEntry 26 } -- # ABR Information sfcsBwPortPoolStatABRConnCntFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established ABR connections for the forward direction." ::= { sfcsBwPortPoolStatEntry 27 } sfcsBwPortPoolStatABRConnCntRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established ABR connections for the reverse direction." ::= { sfcsBwPortPoolStatEntry 28 } sfcsBwPortPoolStatABRConnRejFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of ABR forward connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 29 } sfcsBwPortPoolStatABRConnRejRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of ABR reverse connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 30 } sfcsBwPortPoolStatABRAllocBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of forward allocated Bw that is ABR service class." ::= { sfcsBwPortPoolStatEntry 31 } sfcsBwPortPoolStatABRAllocBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of reverse allocated Bw that is ABR service class." ::= { sfcsBwPortPoolStatEntry 32 } sfcsBwPortPoolStatABRAggPCRFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated forward PCR for all established ABR connections." ::= { sfcsBwPortPoolStatEntry 33 } sfcsBwPortPoolStatABRAggPCRRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated reverse PCR for all established ABR connections." ::= { sfcsBwPortPoolStatEntry 34 } sfcsBwPortPoolStatABRPrevAdverMAXCTD OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The maxCTD for the forward direction reported to PNNI for the last update period for ABR service class." ::= { sfcsBwPortPoolStatEntry 35 } sfcsBwPortPoolStatABRPrevAdverCDV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The CDV for the forward direction reported to PNNI for the last update period for ABR service class." ::= { sfcsBwPortPoolStatEntry 36 } -- # VBR Information sfcsBwPortPoolStatVBRConnCntFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established VBR connections for the forward direction." ::= { sfcsBwPortPoolStatEntry 37 } sfcsBwPortPoolStatVBRConnCntRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established VBR connections for the reverse direction." ::= { sfcsBwPortPoolStatEntry 38 } sfcsBwPortPoolStatVBRConnRejFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of VBR forward connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 39 } sfcsBwPortPoolStatVBRConnRejRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of VBR reverse connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 40 } sfcsBwPortPoolStatVBRAllocBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of forward allocated Bw that is VBR service class." ::= { sfcsBwPortPoolStatEntry 41 } sfcsBwPortPoolStatVBRAllocBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of reverse allocated Bw that is VBR service class." ::= { sfcsBwPortPoolStatEntry 42 } sfcsBwPortPoolStatVBRAggPCRFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated forward PCR for all established VBR connections." ::= { sfcsBwPortPoolStatEntry 43 } sfcsBwPortPoolStatVBRAggPCRRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated reverse PCR for all established VBR connections." ::= { sfcsBwPortPoolStatEntry 44 } sfcsBwPortPoolStatVBRPrevAdverMAXCTD OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The maxCTD for the forward direction reported to PNNI for the last update period for VBR service class." ::= { sfcsBwPortPoolStatEntry 45 } sfcsBwPortPoolStatVBRPrevAdverCDV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The CDV for the forward direction reported to PNNI for the last update period for VBR service class." ::= { sfcsBwPortPoolStatEntry 46 } -- # UBR Information sfcsBwPortPoolStatUBRConnCntFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established UBR connections for the forward direction." ::= { sfcsBwPortPoolStatEntry 47 } sfcsBwPortPoolStatUBRConnCntRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of currently established UBR connections for the reverse direction." ::= { sfcsBwPortPoolStatEntry 48 } sfcsBwPortPoolStatUBRConnRejFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of UBR forward connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 49 } sfcsBwPortPoolStatUBRConnRejRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of UBR reverse connections rejected since the port was initialized or the switch was reset last." ::= { sfcsBwPortPoolStatEntry 50 } sfcsBwPortPoolStatUBRAllocBwFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of forward allocated Bw that is UBR service class." ::= { sfcsBwPortPoolStatEntry 51 } sfcsBwPortPoolStatUBRAllocBwRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The amount of reverse allocated Bw that is UBR service class." ::= { sfcsBwPortPoolStatEntry 52 } sfcsBwPortPoolStatUBRAggPCRFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated forward PCR for all established UBR connections." ::= { sfcsBwPortPoolStatEntry 53 } sfcsBwPortPoolStatUBRAggPCRRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The aggregated reverse PCR for all established UBR connections." ::= { sfcsBwPortPoolStatEntry 54 } sfcsBwPortPoolStatUBRPrevAdverMAXCTD OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The maxCTD for the forward direction reported to PNNI for the last update period for UBR service class." ::= { sfcsBwPortPoolStatEntry 55 } sfcsBwPortPoolStatUBRPrevAdverCDV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The CDV for the forward direction reported to PNNI for the last update period for UBR service class." ::= { sfcsBwPortPoolStatEntry 56 } -- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -- ### Bandwidth Pool Trap Management Information sfcsBwPortPoolTrapMgmtTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsBwPortPoolTrapMgmtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains " ::= { sfcsBwPortPools 3 } sfcsBwPortPoolTrapMgmtEntry OBJECT-TYPE SYNTAX SfcsBwPortPoolTrapMgmtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains " INDEX { sfcsBwPortPoolTrapMgmtIndex, sfcsBwPortPoolTrapMgmtPoolIndex } ::= { sfcsBwPortPoolTrapMgmtTable 1 } SfcsBwPortPoolTrapMgmtEntry ::= SEQUENCE { sfcsBwPortPoolTrapMgmtIndex INTEGER, sfcsBwPortPoolTrapMgmtPoolIndex INTEGER, sfcsBwPortPoolTrapMgmtAllocBwTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtAllocBwTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtAllocBwTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtAllocBwTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtPeakBwTholdFwd INTEGER, sfcsBwPortPoolTrapMgmtPeakBwTholdRev INTEGER, sfcsBwPortPoolTrapMgmtHoldDownTime INTEGER, sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtABRConnCntTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtABRConnCntTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtABRConnCntTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtABRConnCntTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoRev INTEGER, sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiFwd INTEGER, sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiRev INTEGER, sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoFwd INTEGER, sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoRev INTEGER, sfcsBWPortPoolTrapMgmtBuffUpThold INTEGER, sfcsBWPortPoolTrapMgmtBuffLoThold INTEGER, sfcsBWPortPoolTrapMgmtConnRejThold INTEGER } sfcsBwPortPoolTrapMgmtIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which Port we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBwPortPoolTrapMgmtEntry 1 } sfcsBwPortPoolTrapMgmtPoolIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which Pool within Port we are dealing with. This reference is in the same format as MIB II's Interface index. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 2 } sfcsBwPortPoolTrapMgmtAllocBwTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The upper threshold for the Alloc BW fwd trap. When an allocation causes the currently allocated bw to exceed this value the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 3 } sfcsBwPortPoolTrapMgmtAllocBwTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the Alloc BW rev trap. When an allocation causes the currently allocated bw to exceed this value the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 4 } sfcsBwPortPoolTrapMgmtAllocBwTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the Alloc BW fwd trap. When an allocation causes the currently allocated bw be below this value the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 5 } sfcsBwPortPoolTrapMgmtAllocBwTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the Alloc BW rev trap. When an allocation causes the currently allocated bw be below this value the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 6 } sfcsBwPortPoolTrapMgmtPeakBwTholdFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The upper threshold for the Peak BW fwd trap. When an allocation causes the allocated BW to exceed this value the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 7 } sfcsBwPortPoolTrapMgmtPeakBwTholdRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The upper threshold for the Peak BW rev trap. When an allocation causes the allocated BW to exceed this value the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 8 } sfcsBwPortPoolTrapMgmtHoldDownTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The time between traps of the same type. If a trap of a particular type is generated for a particular port, another of that type for that port will not be generated until the hold down time has expired. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 9 } -- # CBR Information sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the CBR connection count Fwd trap. When an allocation causes the CBR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 10 } sfcsBwPortPoolTrapMgmtCBRConnCntTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the CBR connection count Rev trap. When an allocation causes the CBR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 11 } sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the CBR connection count Fwd trap. When an allocation causes the CBR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 12 } sfcsBwPortPoolTrapMgmtCBRConnCntTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the CBR connection count Rev trap. When an allocation causes the CBR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 13 } sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the CBR Allocated Bw Fwd trap. When an allocation causes the CBR Allocated Bw to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 14 } sfcsBwPortPoolTrapMgmtCBRAllocBwTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the CBR connection count Rev trap. When an allocation causes the CBR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 15 } sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the CBR Allocated Bw Fwd trap. When an allocation causes the CBR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 16 } sfcsBwPortPoolTrapMgmtCBRAllocBwTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the CBR Allocated Bw Rev trap. When an allocation causes the CBR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 17 } -- # ABR Information sfcsBwPortPoolTrapMgmtABRConnCntTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the ABR connection count Fwd trap. When an allocation causes the ABR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 18 } sfcsBwPortPoolTrapMgmtABRConnCntTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the ABR connection count Rev trap. When an allocation causes the ABR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 19 } sfcsBwPortPoolTrapMgmtABRConnCntTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the ABR connection count Fwd trap. When an allocation causes the ABR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 20 } sfcsBwPortPoolTrapMgmtABRConnCntTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the ABR connection count Rev trap. When an allocation causes the ABR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 21 } sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the ABR Allocated Bw Fwd trap. When an allocation causes the ABR Allocated Bw to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 22 } sfcsBwPortPoolTrapMgmtABRAllocBwTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the ABR Allocated Bw Rev trap. When an allocation causes the ABR Allocated Bw to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 23 } sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the ABR Allocated Bw Fwd trap. When an allocation causes the ABR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 24 } sfcsBwPortPoolTrapMgmtABRAllocBwTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the ABR Allocated Bw Rev trap. When an allocation causes the ABR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 25 } -- # VBR Information sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the VBR connection count Fwd trap. When an allocation causes the VBR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 26 } sfcsBwPortPoolTrapMgmtVBRConnCntTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the VBR connection count Rev trap. When an allocation causes the VBR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 27 } sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the VBR connection count Fwd trap. When an allocation causes the VBR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 28 } sfcsBwPortPoolTrapMgmtVBRConnCntTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the VBR connection count Rev trap. When an allocation causes the VBR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 29 } sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the VBR Allocated Bw Fwd trap. When an allocation causes the VBR Allocated Bw to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 30 } sfcsBwPortPoolTrapMgmtVBRAllocBwTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the VBR Allocated Bw Rev trap. When an allocation causes the VBR Allocated Bw to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 31 } sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the VBR Allocated Bw Fwd trap. When an allocation causes the VBR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 32 } sfcsBwPortPoolTrapMgmtVBRAllocBwTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the VBR Allocated Bw Rev trap. When an allocation causes the VBR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 33 } -- # UBR Information sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the UBR connection count Fwd trap. When an allocation causes the UBR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 34 } sfcsBwPortPoolTrapMgmtUBRConnCntTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the UBR connection count Rev trap. When an allocation causes the UBR connection count to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 35 } sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the UBR connection count Fwd trap. When an allocation causes the UBR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 36 } sfcsBwPortPoolTrapMgmtUBRConnCntTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the UBR connection count Rev trap. When an allocation causes the UBR connection count to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 37 } sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the UBR Allocated Bw Fwd trap. When an allocation causes the UBR Allocated Bw to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 38 } sfcsBwPortPoolTrapMgmtUBRAllocBwTholdHiRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for the UBR Allocated Bw Rev trap. When an allocation causes the UBR Allocated Bw to exceed this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 39 } sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoFwd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the UBR Allocated Bw Fwd trap. When an allocation causes the UBR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 40 } sfcsBwPortPoolTrapMgmtUBRAllocBwTholdLoRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for the UBR Allocated Bw Rev trap. When an allocation causes the UBR Allocated Bw to fall below this value, the trap is generated. (If it has never been set, the value will be -1.)" ::= { sfcsBwPortPoolTrapMgmtEntry 41 } sfcsBWPortPoolTrapMgmtBuffUpThold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold for buffer allocation trap ." ::= { sfcsBwPortPoolTrapMgmtEntry 42 } sfcsBWPortPoolTrapMgmtBuffLoThold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for buffer allocation trap ." ::= { sfcsBwPortPoolTrapMgmtEntry 43 } sfcsBWPortPoolTrapMgmtConnRejThold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold for conn rejects trap ." ::= { sfcsBwPortPoolTrapMgmtEntry 44 } -- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -- ### Buffer Pool Information -- Each Buffer Pool consists of a number of rows- one for each priority -- The primary index is the ifindex of the port that owns these row entries -- The secondary index is the priority number for the row -- sfcsBuffPrioTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsBuffPrioEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the rows of all the buffer pools." ::= { sfcsBuffPools 1 } sfcsBuffPrioEntry OBJECT-TYPE SYNTAX SfcsBuffPrioEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the rows of all the buffer pools." INDEX { sfcsBuffPrioPortIndex, sfcsBuffPrioPriority } ::= { sfcsBuffPrioTable 1 } SfcsBuffPrioEntry ::= SEQUENCE { sfcsBuffPrioPortIndex INTEGER, sfcsBuffPrioPriority INTEGER, sfcsBuffPrioAssignCtl INTEGER, sfcsBuffPrioMinCtl INTEGER, sfcsBuffPrioAssigned INTEGER, sfcsBuffPrioAllocated INTEGER, sfcsBuffPrioAvailable INTEGER, sfcsBuffPrioPeakAlloc INTEGER, sfcsBuffPrioConnRejs INTEGER, sfcsBuffPrioUpTholdTrap INTEGER, sfcsBuffPrioLoTholdTrap INTEGER, sfcsBuffPrioConnRejThold INTEGER } -- ### Entry Defs sfcsBuffPrioPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which port we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsBuffPrioEntry 1 } sfcsBuffPrioPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which priority we are dealing with." ::= { sfcsBuffPrioEntry 2 } sfcsBuffPrioAssignCtl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The status of how assignment is controlled. Static,Manual,Adaptive. " ::= { sfcsBuffPrioEntry 3} sfcsBuffPrioMinCtl OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The minimum number of cells which can be assigned to this port/prioity." ::= { sfcsBuffPrioEntry 4} sfcsBuffPrioAssigned OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The number of cells which are currently assigned to this port/priority." ::= { sfcsBuffPrioEntry 5} sfcsBuffPrioAllocated OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of assigned cells which are currently allocated to VCs for this port/priority." ::= { sfcsBuffPrioEntry 6} sfcsBuffPrioAvailable OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The number of assigned cells which are free to be allocated." ::= { sfcsBuffPrioEntry 7} sfcsBuffPrioPeakAlloc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " The peak number of cells which have been allocated to this port/priority." ::= { sfcsBuffPrioEntry 8} sfcsBuffPrioConnRejs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The number of connections rejected because of a lack of buffers." ::= { sfcsBuffPrioEntry 9} sfcsBuffPrioUpTholdTrap OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The upper threshold of allocations to trigger an upper thold trap." ::= { sfcsBuffPrioEntry 10} sfcsBuffPrioLoTholdTrap OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold of allocations to trigger a lower thold trap." ::= { sfcsBuffPrioEntry 11} sfcsBuffPrioConnRejThold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " The lower threshold of conn rejects trap because of inadequate buffers." ::= { sfcsBuffPrioEntry 12} -- %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% -- The SFCS ANIM Proxy Group -- SFCS ANIM Proxy Group -- This group contains the managed objects and functions used to setup and -- configure the SFCS ANIM Proxies. This group contains three sub-groups: -- configuration status, Transmit function setup, and Port Read -- SFCS ANIM Proxy Configuration Status Table -- This table contains contains information about the status of the Port or Proxy -- as a whole, as opposed to the receive and Transmit table which contain information -- about cells. sfcsProxyConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsProxyConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the config info and a port reading function." ::= { sfcsProxyConfig 1 } sfcsProxyConfigEntry OBJECT-TYPE SYNTAX SfcsProxyConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains ANIM Proxy config info or a function." INDEX { sfcsProxyConfigANIMIndex } ::= { sfcsProxyConfigTable 1 } SfcsProxyConfigEntry ::= SEQUENCE { sfcsProxyConfigANIMIndex INTEGER, sfcsProxyConfigNUMPORTS INTEGER, sfcsProxyConfigTxMemSize INTEGER, sfcsProxyConfigRxMaxPduSize INTEGER, sfcsProxyConfigBandWidth INTEGER, sfcsProxyConfigTransmitDone INTEGER, sfcsProxyConfigReceiveFifoState INTEGER, sfcsProxyConfigPortTransmitMode INTEGER, sfcsProxyConfigReceiveFifoReset INTEGER, sfcsProxyConfigTxFifoReset INTEGER, sfcsProxyConfigReceiveMode INTEGER, sfcsProxyConfigCaptureMode INTEGER, sfcsProxyConfigInitPort INTEGER, sfcsProxyConfigLoad INTEGER, sfcsProxyConfigGumbo OCTET STRING } sfcsProxyConfigANIMIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which ANIM Proxy we are dealing with. This reference is in the same format as MIB II's Interface index." ::= { sfcsProxyConfigEntry 1 } sfcsProxyConfigNUMPORTS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of ports per Proxy which is always 4." ::= { sfcsProxyConfigEntry 2 } sfcsProxyConfigTxMemSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the size of the port's Transmission memory in K. The memory size is always 1K." ::= { sfcsProxyConfigEntry 3 } sfcsProxyConfigRxMaxPduSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the size of the port's Transmission memory in K. The memory size is always 1K." ::= { sfcsProxyConfigEntry 4 } sfcsProxyConfigBandWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the bandwidth for the port, which is ?????" ::= { sfcsProxyConfigEntry 5 } sfcsProxyConfigTransmitDone OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Checks if the Transmission has finished." ::= { sfcsProxyConfigEntry 6 } sfcsProxyConfigReceiveFifoState OBJECT-TYPE SYNTAX INTEGER { full(1), not-full(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Checks if the port's receive Fifo is full or not." ::= { sfcsProxyConfigEntry 7 } sfcsProxyConfigPortTransmitMode OBJECT-TYPE SYNTAX INTEGER { stop(1), start-stay(2), reread(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls Transmission of cells in port Transmit memory." ::= { sfcsProxyConfigEntry 8 } sfcsProxyConfigReceiveFifoReset OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Controls the receive buffer's memory. Reset clears memory." ::= { sfcsProxyConfigEntry 9 } sfcsProxyConfigTxFifoReset OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Controls the port's transmit memory. Reset clears memory." ::= { sfcsProxyConfigEntry 10 } sfcsProxyConfigReceiveMode OBJECT-TYPE SYNTAX INTEGER { receiving (1), not-receiving (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls whether or not the port receives cells." ::= { sfcsProxyConfigEntry 11 } sfcsProxyConfigCaptureMode OBJECT-TYPE SYNTAX INTEGER { all (1), header (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls how much of the cell is received." ::= { sfcsProxyConfigEntry 12 } sfcsProxyConfigInitPort OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Setting this returns the port to the initial setup." ::= { sfcsProxyConfigEntry 13 } sfcsProxyConfigLoad OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Transmit load for port." ::= { sfcsProxyConfigEntry 14 } sfcsProxyConfigGumbo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Unreadable octet string used for control information." ::= { sfcsProxyConfigEntry 15 } -- SFCS ANIM Proxy Transmit function setup Table. -- This table contains the function to send cells from specific ports and -- the arguments which this function takes. sfcsProxyTransTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsProxyTransEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the arguments and the function for the Transmit function." ::= { sfcsProxyTrans 1 } sfcsProxyTransEntry OBJECT-TYPE SYNTAX SfcsProxyTransEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entries are the arguments for the Transmit function." INDEX { sfcsProxyTransANIMIndex } ::= { sfcsProxyTransTable 1 } SfcsProxyTransEntry ::= SEQUENCE { sfcsProxyTransANIMIndex INTEGER, sfcsProxyTransEncodeNewPdu INTEGER, sfcsProxyTransVPI INTEGER, sfcsProxyTransVCI INTEGER, sfcsProxyTransPTI INTEGER, sfcsProxyTransCLP INTEGER, sfcsProxyTransPayloadType INTEGER, sfcsProxyTransPayloadLength INTEGER, sfcsProxyTransPayloadData OCTET STRING, sfcsProxyTransCount INTEGER, sfcsProxyTransPayloadAdaptionLayer INTEGER, sfcsProxyTransMpxMethod INTEGER, sfcsProxyTransControl INTEGER, sfcsProxyTransGumbo OCTET STRING } sfcsProxyTransANIMIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which ANIM Port we are dealing with. This reference is in the same format as MIB II's Interface Index." ::= { sfcsProxyTransEntry 1 } sfcsProxyTransEncodeNewPdu OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Setting this encodes a new PDU based on the current PDU parameters into the port's transmit memory." ::= { sfcsProxyTransEntry 2 } sfcsProxyTransVPI OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the VPI for the PDU." ::= { sfcsProxyTransEntry 3 } sfcsProxyTransVCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the VCI for the PDU." ::= { sfcsProxyTransEntry 4 } sfcsProxyTransPTI OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "Payload Type Indicator: the value of the 3 bit Payload Type field in the header. The most signifigant bit indicates user or control data, the next bit indicates congestion, and the last bit indicates AAL encoding." ::= { sfcsProxyTransEntry 5 } sfcsProxyTransCLP OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The cell loss priority: 1 or 0." ::= { sfcsProxyTransEntry 6 } sfcsProxyTransPayloadType OBJECT-TYPE SYNTAX INTEGER { user-input(1), sequential(2), uniform(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The payload type for the cell." ::= { sfcsProxyTransEntry 7 } sfcsProxyTransPayloadLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The length of the payload in bytes." ::= { sfcsProxyTransEntry 8 } sfcsProxyTransPayloadData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If the payload type is user input, this is the payload itself." ::= { sfcsProxyTransEntry 9 } sfcsProxyTransCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of copies of the pdu to encode in port transmit memory." ::= { sfcsProxyTransEntry 10 } sfcsProxyTransPayloadAdaptionLayer OBJECT-TYPE SYNTAX INTEGER { raw(1), aal5(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The format of the payload: either raw cells or AAL5." ::= { sfcsProxyTransEntry 11 } sfcsProxyTransMpxMethod OBJECT-TYPE SYNTAX INTEGER --{ -- enumerate me!! -- } ACCESS read-write STATUS mandatory DESCRIPTION "The format of the payload: either raw cells or AAL5." ::= { sfcsProxyTransEntry 12 } sfcsProxyTransControl OBJECT-TYPE SYNTAX INTEGER { send-once(1), repeat(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls how many times to send what's in the port's transmit memory." ::= { sfcsProxyTransEntry 13 } sfcsProxyTransGumbo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Returns the vpi, vci, pti, clp, payload_type, payload_length, count, PAL, mpx method, and control entires for this table in a string where the entries are separated by semicolons." ::= { sfcsProxyTransEntry 14 } -- SFCS ANIM Port Read -- This table contains the information read from cells from a port's receive fifo. sfcsProxyReadTable OBJECT-TYPE SYNTAX SEQUENCE OF SfcsProxyReadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains information read from the cells in the receive fifo." ::= { sfcsProxyRead 1 } sfcsProxyReadEntry OBJECT-TYPE SYNTAX SfcsProxyReadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entries are the information about the cells or the PDU." INDEX { sfcsProxyReadANIMIndex } ::= { sfcsProxyReadTable 1 } SfcsProxyReadEntry ::= SEQUENCE { sfcsProxyReadANIMIndex INTEGER, sfcsProxyReadMode INTEGER, sfcsProxyReadNewPdu INTEGER, sfcsProxyReadGumbo OCTET STRING, sfcsProxyReadVPI INTEGER, sfcsProxyReadVCI INTEGER, sfcsProxyReadPTI INTEGER, sfcsProxyReadCLP INTEGER, sfcsProxyReadDataLength INTEGER, sfcsProxyReadData OCTET STRING, sfcsProxyReadPal INTEGER, sfcsProxyReadInbyteslosts INTEGER, sfcsProxyReadInCells INTEGER, sfcsProxyReadInError INTEGER, sfcsProxyReadInCellReadError INTEGER, sfcsProxyReadInHecError INTEGER, sfcsProxyReadInTooBigError INTEGER, sfcsProxyReadInCRCError INTEGER, sfcsProxyReadInLengthMismatchError INTEGER, sfcsProxyReadInTotalCells INTEGER } sfcsProxyReadANIMIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This index specifies which ANIM Port we are dealing with. This reference is in the same format as the MIB II Interface Index." ::= { sfcsProxyReadEntry 1 } sfcsProxyReadMode OBJECT-TYPE SYNTAX INTEGER { reassemble-PDU(1), cell-by-cell(2), all-data(3) } ACCESS read-write STATUS mandatory DESCRIPTION "How the receive fifo is read." ::= { sfcsProxyReadEntry 2 } sfcsProxyReadNewPdu OBJECT-TYPE SYNTAX INTEGER { get-next-pdu(1), reread-from-beginning(2) } ACCESS write-only STATUS mandatory DESCRIPTION "Pops a new Pdu from the receive fifo to be examined and read." ::= { sfcsProxyReadEntry 3 } sfcsProxyReadGumbo OBJECT-TYPE SYNTAX OCTET STRING ACCESS write-only STATUS mandatory DESCRIPTION "Unreadable control information." ::= { sfcsProxyReadEntry 4 } sfcsProxyReadVPI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the VPI for the PDU." ::= { sfcsProxyReadEntry 5 } sfcsProxyReadVCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the VCI for the PDU." ::= { sfcsProxyReadEntry 6 } sfcsProxyReadPTI OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "Payload Type Indicator: the value of the 3 bit Payload Type field in the header. The most signifigant bit indicates user or control data, the next bit indicates congestion, and the last bit indicates AAL encoding." ::= { sfcsProxyReadEntry 7 } sfcsProxyReadCLP OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The cell loss priority: 1 or 0." ::= { sfcsProxyReadEntry 8 } sfcsProxyReadDataLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length of the PDU in bytes." ::= { sfcsProxyReadEntry 9 } sfcsProxyReadData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The actual data of the PDU." ::= { sfcsProxyReadEntry 10 } sfcsProxyReadPal OBJECT-TYPE SYNTAX INTEGER { raw(1), aal5(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The format of the payload: either raw cells or AAL5." ::= { sfcsProxyReadEntry 11 } sfcsProxyReadInbyteslosts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes that were dropped while reading. Usually because they occurred before the Start of Cell was discovered." ::= { sfcsProxyReadEntry 12 } sfcsProxyReadInCells OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells read since this port was last reset." ::= { sfcsProxyReadEntry 13 } sfcsProxyReadInError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of pdu's that had to be dropped due to errors." ::= { sfcsProxyReadEntry 14 } sfcsProxyReadInCellReadError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells that had to be dropped due to errors." ::= { sfcsProxyReadEntry 15 } sfcsProxyReadInHecError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of cell headers that contained errors." ::= { sfcsProxyReadEntry 16 } sfcsProxyReadInTooBigError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of pdu's that were too large to be received." ::= { sfcsProxyReadEntry 17 } sfcsProxyReadInCRCError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of pdu's that failed the CRC check." ::= { sfcsProxyReadEntry 18 } sfcsProxyReadInLengthMismatchError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length stored in the pdu did not match the actual length of the pdu read in." ::= { sfcsProxyReadEntry 19 } sfcsProxyReadInTotalCells OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of cells read in by the snapshot." ::= { sfcsProxyReadEntry 20 } END