CTRON-APPN-MIB DEFINITIONS ::= BEGIN -- ctron-appn-mib.txt -- Revision: 1.00.03 -- Part Number: 2171066 -- Date: June 20, 1996 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for Cabletron's -- enterprise specific APPN Routing Services MIB. -- -- -- This module will be extended as required. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright August 95 Cabletron Systems IMPORTS OBJECT-TYPE FROM RFC-1212 nwRtrProtoSuites FROM ROUTER-OIDS DisplayString FROM RFC1213-MIB Counter, TimeTicks FROM RFC1155-SMI; -- The APPN Router Group. nwAppnRouter OBJECT IDENTIFIER ::= { nwRtrProtoSuites 5 } nwAppnMibs OBJECT IDENTIFIER ::= { nwAppnRouter 1 } nwAppnComponents OBJECT IDENTIFIER ::= { nwAppnRouter 2 } -- APPN Router Component Groups nwAppnSystem OBJECT IDENTIFIER ::= { nwAppnComponents 1 } nwAppnForwarding OBJECT IDENTIFIER ::= { nwAppnComponents 2 } nwAppnTopology OBJECT IDENTIFIER ::= { nwAppnComponents 4 } nwAppnFib OBJECT IDENTIFIER ::= { nwAppnComponents 5 } nwAppnEndSystems OBJECT IDENTIFIER ::= { nwAppnComponents 6 } nwAppnAccessControl OBJECT IDENTIFIER ::= { nwAppnComponents 7 } nwAppnFilters OBJECT IDENTIFIER ::= { nwAppnComponents 8 } nwAppnRedirector OBJECT IDENTIFIER ::= { nwAppnComponents 9 } nwAppnEvent OBJECT IDENTIFIER ::= { nwAppnComponents 10 } nwAppnWorkGroup OBJECT IDENTIFIER ::= { nwAppnComponents 11 } -- APPN Router System Groups nwAppnSysConfig OBJECT IDENTIFIER ::= { nwAppnSystem 1 } nwAppnSysAdministration OBJECT IDENTIFIER ::= { nwAppnSystem 2 } -- APPN Router System Configuration Groups nwAppnSysCfgLocalNode OBJECT IDENTIFIER ::= { nwAppnSysConfig 2 } nwAppnSysCfgTables OBJECT IDENTIFIER ::= { nwAppnSysConfig 3 } -- APPN Router Forwarding Groups nwAppnFwdSystem OBJECT IDENTIFIER ::= { nwAppnForwarding 1 } nwAppnFwdInterfaces OBJECT IDENTIFIER ::= { nwAppnForwarding 2 } nwAppnFwdLinks OBJECT IDENTIFIER ::= { nwAppnForwarding 3 } nwAppnFwdCounters OBJECT IDENTIFIER ::= { nwAppnFwdSystem 1 } nwAppnFwdIfConfig OBJECT IDENTIFIER ::= { nwAppnFwdInterfaces 1 } nwAppnIfCn OBJECT IDENTIFIER ::= { nwAppnFwdIfConfig 3 } nwAppnFwdIfCounters OBJECT IDENTIFIER ::= { nwAppnFwdInterfaces 2 } nwAppnFwdLsConfig OBJECT IDENTIFIER ::= { nwAppnFwdLinks 1 } nwAppnFwdLsCounters OBJECT IDENTIFIER ::= { nwAppnFwdLinks 2 } -- APPN Router Routing Groups nwAppnDistanceVector OBJECT IDENTIFIER ::= { nwAppnTopology 1 } nwAppnLinkState OBJECT IDENTIFIER ::= { nwAppnTopology 2 } nwAppnIsr OBJECT IDENTIFIER ::= { nwAppnLinkState 1 } nwAppnIsrSystem OBJECT IDENTIFIER ::= { nwAppnIsr 1 } nwAppnIsrInterfaces OBJECT IDENTIFIER ::= { nwAppnIsr 2 } nwAppnIsrDatabase OBJECT IDENTIFIER ::= { nwAppnIsr 3 } nwAppnIsrFilters OBJECT IDENTIFIER ::= { nwAppnIsr 4 } nwAppnIsrConfig OBJECT IDENTIFIER ::= { nwAppnIsrSystem 1 } nwAppnIsrCounters OBJECT IDENTIFIER ::= { nwAppnIsrSystem 2 } nwAppnIsrIfConfig OBJECT IDENTIFIER ::= { nwAppnIsrInterfaces 1 } nwAppnIsrIfCounters OBJECT IDENTIFIER ::= { nwAppnIsrInterfaces 2 } -- APPN Router Host End Systems Groups ( NOT USED ) nwAppnHostsSystem OBJECT IDENTIFIER ::= { nwAppnEndSystems 1 } nwAppnHostsInterfaces OBJECT IDENTIFIER ::= { nwAppnEndSystems 2 } -- APPN Router Event Log Group nwAppnEventLogConfig OBJECT IDENTIFIER ::= { nwAppnEvent 1 } nwAppnEventLogFilterTable OBJECT IDENTIFIER ::= { nwAppnEvent 2 } nwAppnEventLogTable OBJECT IDENTIFIER ::= { nwAppnEvent 3 } -- APPN MIB Group -- This group contains information about the revision level of this -- MIB within the device. It allows verification of the released -- version without having to read other objects. nwAppnMibRevText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the Cabletron APPN Router MIB in textual format." ::= { nwAppnMibs 1 } -- APPN Routing Services System Group -- This group contains the objects related to APPN Routing Services at a -- global system-wide level. -- APPN Routing Services System Configuration Group -- This group contains the objects that pertain to the setup and -- configuration of APPN Routing Services at a global, -- system-wide level. nwAppnSysRouterId OBJECT-TYPE SYNTAX DisplayString (SIZE (3..17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the APPN Fully-Qualified Control Point name that is used to uniquely identify APPN Routing Services in an APPN network. The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network identifier and CCCCCCCC is the Control Point name. Valid characters to make up these two strings are uppercase letters A through Z, numerics 0 through 9, and the special characters $, @, and #. The first character of the string must NOT be numeric. Each string must be a maximum length of 8 characters with no embedded spaces and the strings are joined by a dot. nwAppnSysRouterId cannot be modified while APPN routing services is in any operational state other than DISABLED as reflected in nwAppnSysOperStatus. Otherwise, the request will be rejected." ::= { nwAppnSysConfig 1 } -- APPN Routing Services System Group -- This group contains the objects related to initializing APPN Routing Services -- at a global, system-wide level. -- All parameters (except for Stop Type) cannot be modified unless the -- operational state is disabled. Otherwise, the request will be rejected. nwAppnSysNodeType OBJECT-TYPE SYNTAX INTEGER { networknode(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the node type supported by APPN Routing Services which is always of type Network Node. " DEFVAL { networknode } ::= { nwAppnSysCfgLocalNode 1 } nwAppnSysCpAlias OBJECT-TYPE SYNTAX DisplayString (SIZE (1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Control Point alias name used by APPN Routing Services. " ::= { nwAppnSysCfgLocalNode 2 } nwAppnSysModeCosMap OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether mode to COS mapping is supported by APPN Routing Services." DEFVAL { yes } ::= { nwAppnSysCfgLocalNode 3 } nwAppnSysMdsSupport OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether Management Services supports Multiple Domain Support and Management Services capabilities. " DEFVAL { yes } ::= { nwAppnSysCfgLocalNode 4 } nwAppnSysMaxLocates OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum Number of locate requests that APPN Routing Services can concurrently process. Note: if nwAppnSysMaxLocates is set to a value too small, it will be internally increased to a higher value after APPN Routing Services has been successfully enabled. A subsequent GET operation on nwAppnSysMaxLocates will reflect this new value." DEFVAL { 10 } ::= { nwAppnSysCfgLocalNode 6 } nwAppnSysDirCacheSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies number of located resources maintained in the Directory Cache. Note: if nwAppnSysDirCacheSize is set to a value too small, it will be internally increased to a higher value after APPN routing services has been successfully enabled. A subsequent GET operation on nwAppnSysDirCacheSize will reflect this new value. " DEFVAL { 255 } ::= { nwAppnSysCfgLocalNode 7 } nwAppnSysMaxDirEntries OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum number of directory entries. If zero is selected, the number of entries is unlimited. " DEFVAL { 0 } ::= { nwAppnSysCfgLocalNode 8} nwAppnSysLocateTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies time in seconds before a network search will timeout. Zero indicates that the search has no timeout." DEFVAL { 0 } ::= { nwAppnSysCfgLocalNode 9 } nwAppnSysRegCds OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the local or domain resources can be registered with the Central Directory Server." DEFVAL { yes } ::= { nwAppnSysCfgLocalNode 10 } nwAppnSysMdsSendQSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies size of the MDS send alert Queue." DEFVAL { 100 } ::= { nwAppnSysCfgLocalNode 11 } nwAppnSysCosSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum number of COS definitions maintained in the COS database weights cache. It determines the size of the COS Database weights cache. Note: if nwAppnSysCosSize is set to a value too small, it will be internally increased to a higher value after APPN Routing Services has been successfully enabled. A subsequent GET operation on nwAppnSysCosSize will reflect this new value. " DEFVAL { 16 } ::= { nwAppnSysCfgLocalNode 12 } nwAppnSysTreeSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the number of routes maintained in the Topology Database routing tree cache. Note: if nwAppnSysTreeSize is set to a value too small, it will be internally increased to a higher value after APPN Routing Services has been successfully enabled. A subsequent GET operation on nwAppnSysTreeSize will reflect this new value. " DEFVAL { 40 } ::= { nwAppnSysCfgLocalNode 13 } nwAppnSysTreeUseLimit OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Maximum number of times a cached tree will be used to compute a route before the tree is discarded and recomputed. This allows the APPN Routing Services to balance sessions among equal weight routes. A low value provides better load balancing at the expense of increased activation latency. " DEFVAL { 40 } ::= { nwAppnSysCfgLocalNode 14 } nwAppnSysMaxTdmNodes OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum number of nodes that can be stored in the Topology Database. Zero means unlimited. " DEFVAL { 0 } ::= { nwAppnSysCfgLocalNode 15 } nwAppnSysMaxTdmTGs OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum number of transmission groups that can be stored in Topology Database. Zero means unlimited. " DEFVAL { 0 } ::= { nwAppnSysCfgLocalNode 16 } nwAppnSysMaxIsrSessions OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum number of intermediate routing sessions permitted by APPN Routing Services at one time. This must be a non-negative number." DEFVAL { 1000 } ::= { nwAppnSysCfgLocalNode 18 } nwAppnSysIsrUpperThresh OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The thresholds control the congestion status of APPN routing services. If the number of ISR sessions exceeds the upper threshold, congestion status changes from uncongested to congested. When this occurs, the status will not become uncongested until the the number of ISR sessions fall below the lower threshold. The lower threshold should be less than the upper threshold to prevent thrashing. The upper threshold should be lower than nwAppnSysMaxIsrSessions. This must be a non-negative number." DEFVAL { 900 } ::= { nwAppnSysCfgLocalNode 19 } nwAppnSysIsrLowerThresh OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifes the number of ISR sessions at which congestion status will revert to uncongested. This must be a non-negative number. nwAppnSysIsrLowerThresh must be less than nwAppnSysIsrUpperThresh to prevent thrashing. " DEFVAL { 800 } ::= { nwAppnSysCfgLocalNode 20 } nwAppnSysIsrMaxRuSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum RU size supported for intermediate sessions. Note: the number provided will be rounded up to the next valid RU size if necessary after APPN Routing Services has been successfully enabled. A subsequent GET operation on nwAppnSysMaxLocates will reflect this new value." DEFVAL { 1024 } ::= { nwAppnSysCfgLocalNode 21 } nwAppnSysIsrRcvPaceWind OBJECT-TYPE SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies suggested receive pacing window size for intermediate sessions. This value may be used as a fixed window size for fixed pacing, or as a tuning value for adaptive pacing. " DEFVAL { 8 } ::= { nwAppnSysCfgLocalNode 22 } nwAppnSysRtAddResist OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies a desirability factor for APPN Routing Services to perform intermediate session routing. 255 is least desirable and 0 is more desirable. " DEFVAL { 0 } ::= { nwAppnSysCfgLocalNode 23 } nwAppnSysStopType OBJECT-TYPE SYNTAX INTEGER { abort(1), -- Shutdown APPN Routing Services immediately immediate(2), -- deactivate links then abort(1) quiesce(3), -- advertize quiesce, deactivate endpoint -- sessions, then immediate(2) quiesceIsr(4) -- allow all isr sessions to end then -- quiesce(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of APPN Routing Services shutdown. Once specified, select disable from nwAppnSysAdminStatus. The shutdown choices are as follows: abort(1) All APPN Routing Services components are immediately stopped and resources released. To become active again, the APPN Routing Services must be enabled. immediate(2) APPN Routing Services immediately deactivates all links then performs abort(1) processing. quiesce(3) APPN Routing Services indicates to other APPN network nodes that it is quiesced. Session limits are reset on all modes, UNBINDs are issued on all endpoint sessions (CP-CP sessions last), and then immediate(2) processing is performed. quiesceIsr(4) Allows all intermediate sessions to end, then performs the quiesce(3) processing." DEFVAL { quiesceIsr } ::= { nwAppnSysCfgLocalNode 24 } nwAppnSysBlockNum OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "This represents the 3 hexadecimal digit block number which precedes the 5 digit id number in the 8 digit node id used in XIDs and Alerts. The block number identifies the product type. Both the block number and id number combined, uniquely identify this instance of APPN Routing Services within the installation network." -- DEFVAL { 'e08'H } ::= { nwAppnSysCfgLocalNode 25 } nwAppnSysIdNum OBJECT-TYPE SYNTAX DisplayString (SIZE(5)) ACCESS read-write STATUS mandatory DESCRIPTION "This represents the 5 hexadecimal digit id number which follows the 3 digit block number in the 8 digit node id used in XIDs and Alerts. The id number uniquely identifies this instance of APPN Routing Services within a product type indicated by the block number. Both the block number and id number combined, uniquely identify this instance of APPN Routing Services within the installation network." -- DEFVAL { '00000'H } ::= { nwAppnSysCfgLocalNode 26 } -- APPN Router System Group - Local APPN Routing Service Parameters -- This group contains tables related to configuring: -- -- LU Definition Table -- -- LU Table -- nwAppnSysLuTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnSysLuEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains entries for LUs that are owned by adjacent LEN nodes. Defining or deleting an entry is equivalent to defining or deleting an entry in the directory database. To add an entry, set nwAppnSysLuControl to other. To delete an entry, set nwAppnSysLuControl to delete." ::= { nwAppnSysCfgTables 1 } nwAppnSysLuEntry OBJECT-TYPE SYNTAX NwAppnSysLuEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry defines an LU entry in the directory database. The fully qualified CP name and the name of the LU are the indexes into this table." INDEX { nwAppnSysCpName, nwAppnSysLuName } ::= { nwAppnSysLuTable 1 } NwAppnSysLuEntry ::= SEQUENCE { nwAppnSysCpName DisplayString, nwAppnSysLuName DisplayString, nwAppnSysLuControl INTEGER } nwAppnSysCpName OBJECT-TYPE SYNTAX DisplayString (SIZE (3..17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the fully qualified name of the Control Point containing the LU being defined. The format of this name is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network identifier and CCCCCCCC is the LU or Control Point name. Valid characters to make up these two strings are uppercase letters A through Z, numerics 0 through 9 and the special charcters $, @, and #. The first character of the name must NOT be numeric. Each string must be a maximum length of 8 characters with no embedded spaces and the strings are joined by a dot. This CP name must appear as an Adjacent CP in a link station definition where the adjacent CP type is EN and CP-CP session support is NO." ::= { nwAppnSysLuEntry 1 } nwAppnSysLuName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the name of the LU being registered. The name format is LLLLLLLL where LLLLLLLL are the characters: uppercase letters A through Z, numerics 0 through 9, and the special characters $, @, and #. The first character of the name must NOT be numeric. The string must be a maximum length of 8 characters with no embedded spaces. Note that the nework identifier of the LU is taken from the fully qualified control point name of the adjacent LEN node (nwAppnSysCpName) which owns the LU. " ::= { nwAppnSysLuEntry 2 } nwAppnSysLuControl OBJECT-TYPE SYNTAX INTEGER { other(1), delete(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set this object to delete to remove an entry." ::= { nwAppnSysLuEntry 3 } -- APPN System Administration Group -- This group contains the objects that pertain to the administration of -- APPN Routing Services at a global, system-wide level. nwAppnSysAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disable(2), -- shut down APPN Routing Services enabled(3) -- start up APPN Routing Services } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the system-wide administrative state of APPN Routing Services. If enable(3) is selected, APPN Routing Services is activated. There are two cases: the very first activation, and activations subsequent to the successful first activation. Before activating APPN Routing Services the very first time, nwAppnSysRouterId in the System Configuration branch and all objects under nwAppnSysCfgLocalNode must be assigned a value. If not explicitly assigned, default values will be used for objects under nwAppnSysCfgLocalNode. After this first activation has completed successfully, all objects under nwAppnSysCfgLocalNode will be saved in non-volatile RAM and restored for the next node activation at power up time. After this subsequent power up, enable(3) may be selected without setting nwAppnSysRouterId or any objects under under nwAppnSysCfgLocalNode. Those values defined prior to the last power up or reset will be used. If disable(2) is selected, APPN Routing Services will become inactive in the manner specifed by nwAppnSysStopType. To modify objects under nwAppnSysCfgLocalNode, nwAppnSysAdminStatus must be disabled. " ::= { nwAppnSysAdministration 1 } nwAppnSysOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- inactive enabled(3), -- active pendingDisable(4), -- deactivate in progress pendingEnable(5) -- activate in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating system-wide status of APPN Routing Services. " ::= { nwAppnSysAdministration 2 } nwAppnSysAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following reset(2) -- force a reset } ACCESS read-write STATUS mandatory DESCRIPTION "Resets APPN Routing Services system-wide. Reset (2) forces a restart of APPN Routing Services without a graceful shutdown on any active router ports, without affecting any other routing services." ::= { nwAppnSysAdministration 3 } nwAppnSysOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwAppnOperStatus has been in its current state." ::= { nwAppnSysAdministration 4 } nwAppnSysVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of APPN routing services in textual format." ::= { nwAppnSysAdministration 5 } -- APPN Forwarding Group -- This group contains the managed objects used to setup and configure -- APPN Routing Services for aggregate, system-wide, port Message Unit -- (MU) and byte counters. nwAppnFwdCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the aggregate, system-wide, port Message Unit (MU) and byte counters. Enabled (3) causes these counters to become active. Disabled (2) causes these counters to become inactive." ::= { nwAppnFwdCounters 1 } nwAppnFwdCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the aggregate, system-wide port Message Unit (MU) and byte counters. Reset (2) resets the aggregate counters to 0. nwAppnFwdCtrOperationalTime is also reset to 0." ::= { nwAppnFwdCounters 2 } nwAppnFwdCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwAppnFwdCtrAdminStatus has been in the current state." ::= { nwAppnFwdCounters 3 } nwAppnFwdCtrInMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MU)s that have been received system-wide (for all ports) during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 4 } nwAppnFwdCtrOutMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MU)s that have been transmitted system-wide (for all ports) during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 5 } nwAppnFwdCtrFwdMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MU)s that have been forwarded system-wide (for all ports) during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 6 } nwAppnFwdCtrFilteredMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdCounters 7 } nwAppnFwdCtrDiscardMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdCounters 8 } nwAppnFwdCtrAddrErrMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that have been received system-wide (for all ports), during nwAppnFwdCtrOperationalTime, that contain an address error(s) in the SNA header." ::= { nwAppnFwdCounters 9 } nwAppnFwdCtrLenErrMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that have been received system-wide (for all ports), during nwAppnFwdCtrOperationalTime, that contain a length error." ::= { nwAppnFwdCounters 10 } nwAppnFwdCtrHdrErrMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that have been received system-wide (for all ports), during nwAppnFwdCtrOperationalTime, that contain an SNA header error other than an address or length error." ::= { nwAppnFwdCounters 11 } nwAppnFwdCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates number of bytes in Message Units (MUs) that have been received system-wide (for all ports), during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 12 } nwAppnFwdCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in Message Units (MUs) that have been forwarded system-wide (for all ports), during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 13 } nwAppnFwdCtrFwdBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in Message Units (MUs) that have been forwarded system-wide (for all ports), during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 14 } nwAppnFwdCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdCounters 15 } nwAppnFwdCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdCounters 16 } nwAppnFwdCtrHostInMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that have been delivered system-wide (for all ports), to local half sessions during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 17 } nwAppnFwdCtrHostOutMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that have been successfully sent from local half sessions system-wide (for all ports), to Path Control during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 18 } nwAppnFwdCtrHostDiscardMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdCounters 19 } nwAppnFwdCtrHostInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in Message Units (MUs) that have been delivered system-wide (for all ports), to local half sessions during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 20 } nwAppnFwdCtrHostOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in Message Units (MUs) that have been successfully sent from local half sessions system-wide (for all ports), to Path Control during nwAppnFwdCtrOperationalTime." ::= { nwAppnFwdCounters 21 } nwAppnFwdCtrHostDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdCounters 22 } -- APPN Forwarding Port Table -- This table contains the managed objects used to setup and configure -- each port used by APPN Routing Services. -- -- nwAppnFwdIfTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnFwdIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each router port which can be used by APPN Routing Services. This table is indexed by nwAppnFwdIfIndex, which indicates the value of MIB 2 ifindex which identifes the router port for which an entry exists. These port configuration entries will be provided automatically based on physical port configuration. Such entries cannot be deleted - only modified." ::= { nwAppnFwdIfConfig 1 } nwAppnFwdIfEntry OBJECT-TYPE SYNTAX NwAppnFwdIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the APPN Routing Services port configuration for the router port for which the entry exists." INDEX { nwAppnFwdIfIndex } ::= { nwAppnFwdIfTable 1 } NwAppnFwdIfEntry ::= SEQUENCE { nwAppnFwdIfIndex INTEGER, nwAppnFwdIfAdminStatus INTEGER, nwAppnFwdIfOperStatus INTEGER, nwAppnFwdIfOperationalTime TimeTicks, nwAppnFwdIfControl INTEGER, nwAppnFwdIfMtu INTEGER, nwAppnFwdIfForwarding INTEGER, nwAppnFwdIfFrameType INTEGER, nwAppnFwdIfAclIdentifier INTEGER, nwAppnFwdIfAclStatus INTEGER, nwAppnFwdIfCacheControl INTEGER, nwAppnFwdIfCacheEntries Counter, nwAppnFwdIfCacheHits Counter, nwAppnFwdIfCacheMisses Counter } nwAppnFwdIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB2 ifindex, which identifies the router port for which the entry exists. " ::= { nwAppnFwdIfEntry 1 } nwAppnFwdIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of an APPN Routing Services port for which the entry exists. enabled(3) causes the APPN Routing Services port to become active. disable(2) causes it to become inactive. There are various choices for the method by which the port can be disabled, which are enumerated by nwAppnExtIfStopType. " ::= { nwAppnFwdIfEntry 2 } nwAppnFwdIfOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- inactive enabled(3), -- active pendingDisable(4), -- deactivate in progress pendingEnable(5) -- activate in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current operating condition of the APPN Routing Services port for which the entry exists." ::= { nwAppnFwdIfEntry 3 } nwAppnFwdIfOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwAppnFwdIfOperStatus has been in the current state." ::= { nwAppnFwdIfEntry 4 } nwAppnFwdIfControl OBJECT-TYPE SYNTAX INTEGER { other(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 5 } nwAppnFwdIfMtu OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 6 } nwAppnFwdIfForwarding OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 7 } nwAppnFwdIfFrameType OBJECT-TYPE SYNTAX INTEGER { other(1), ethernet(2), i8022(4), sync(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the framing type for the APPN Routing Services port for which the entry exists. " ::= { nwAppnFwdIfEntry 8 } nwAppnFwdIfAclIdentifier OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 9 } nwAppnFwdIfAclStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 10 } nwAppnFwdIfCacheControl OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 11 } nwAppnFwdIfCacheEntries OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 12 } nwAppnFwdIfCacheHits OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 13 } nwAppnFwdIfCacheMisses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs. Setting this object has no effect." ::= { nwAppnFwdIfEntry 14 } -- The APPN Routing Services Port Extension Table -- This table contains additional objects used to setup and configure -- APPN Routing Services on a per port basis. nwAppnExtensionTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnExtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains additional APPN definitions for each physical port. Entries cannot be added to or deleted from this table. With the exception of nwAppnExtIfStopType, objects in this table may only be modified when nwAppnFwdIfAdminStatus is disabled. Note: if APPN Routing Services is not active, no entries will exist for this table. " ::= { nwAppnFwdIfConfig 2 } nwAppnExtEntry OBJECT-TYPE SYNTAX NwAppnExtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies additional APPN configuration parameters for the port for which this entry exists." INDEX { nwAppnExtIfIndex } ::= { nwAppnExtensionTable 1 } NwAppnExtEntry ::= SEQUENCE { nwAppnExtIfIndex INTEGER, nwAppnExtIfPortName DisplayString, nwAppnExtIfPortType INTEGER, nwAppnExtIfDlcType INTEGER, nwAppnExtIfMaxRBtuSize INTEGER, nwAppnExtIfTotLsActLim INTEGER, nwAppnExtIfInbLsActLim INTEGER, nwAppnExtIfOutbLsActLim INTEGER, nwAppnExtIfLocalLsRole INTEGER, nwAppnExtIfActXidXchgLimit INTEGER, nwAppnExtIfNonActXidXchgLimit INTEGER, nwAppnExtIfLsXmitRcvCap INTEGER, nwAppnExtIfMaxIfrmRcvd INTEGER, nwAppnExtIfDfltTargetPacing INTEGER, nwAppnExtIfDfltMaxSBtuSize INTEGER, nwAppnExtIfDfltEffectCap INTEGER, nwAppnExtIfDfltConnectCost INTEGER, nwAppnExtIfDfltByteCost INTEGER, nwAppnExtIfDfltSecurity INTEGER, nwAppnExtIfDfltPropDelay INTEGER, nwAppnExtIfDfltUsrDef1 INTEGER, nwAppnExtIfDfltUsrDef2 INTEGER, nwAppnExtIfDfltUsrDef3 INTEGER, nwAppnExtIfStopType INTEGER, nwAppnExtIfCpCpSupp INTEGER, nwAppnExtIfLimitedRsrc INTEGER, nwAppnExtIfAddress OCTET STRING, nwAppnExtIfSsap OCTET STRING } nwAppnExtIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the primary index into the APPN port extension table. This number corresponds to the index into the nwAppnFwdIfTable. " ::= { nwAppnExtEntry 1 } nwAppnExtIfPortName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the user friendly name for this port. " ::= { nwAppnExtEntry 2 } nwAppnExtIfPortType OBJECT-TYPE SYNTAX INTEGER { nonswitched(1), switched(2), satf(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of line used by the port. The value corresponds to one of the following: nonswitched(1), switched(2), or satf(3). " ::= { nwAppnExtEntry 4 } nwAppnExtIfDlcType OBJECT-TYPE SYNTAX INTEGER { llc2(1), sdlc(2), x25(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the type of DLC using the port. " ::= { nwAppnExtEntry 5 } nwAppnExtIfMaxRBtuSize OBJECT-TYPE SYNTAX INTEGER (99..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum Message Unit (MU) size that can be received. " DEFVAL { 2048 } ::= { nwAppnExtEntry 6 } nwAppnExtIfTotLsActLim OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the total number of links that can be active on this port. If nwAppnExtIfPortType = nonswitched(1) and nwAppnExtIfLocalLsRole = negotiable(1), or secondary(3), then this value must be set to 1. " DEFVAL { 16 } ::= { nwAppnExtEntry 7 } nwAppnExtIfInbLsActLim OBJECT-TYPE SYNTAX INTEGER (0..256) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the total number of inbound links that can be active on this port. If nwAppnExtIfPortType = nonswitched(1) and nwAppnExtIfLocalLsRole = negotiable(1) or primary(2), then this value must be set to 0. " DEFVAL { 8 } ::= { nwAppnExtEntry 8 } nwAppnExtIfOutbLsActLim OBJECT-TYPE SYNTAX INTEGER (0..256) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the total number of outbound links that can be active on this port. If nwAppnExtIfPortType = nonswitched(1) and nwAppnExtIfLocalLsRole = negotiable(1), then this value must be set to 0. If nwAppnExtIfLocalLsRole = primary(2), then this value must be set the same as nwAppnExtIfTotLsActLim. " DEFVAL { 8 } ::= { nwAppnExtEntry 9 } nwAppnExtIfLocalLsRole OBJECT-TYPE SYNTAX INTEGER { negotiable(1), primary(2), secondary(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the link station role - primary, secondary, or negotiable. For nwAppnExtIfPortType = satf(3), the link station role must be negotiable(1). " DEFVAL { negotiable } ::= { nwAppnExtEntry 10 } nwAppnExtIfActXidXchgLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the total number of activation XIDs that may be exchanged. " DEFVAL { 9 } ::= { nwAppnExtEntry 11 } nwAppnExtIfNonActXidXchgLimit OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the total number of non-activation XIDs that may be exchanged. " DEFVAL { 5 } ::= { nwAppnExtEntry 12 } nwAppnExtIfLsXmitRcvCap OBJECT-TYPE SYNTAX INTEGER { twowaysimultaneous(1), twowayalternating(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the link station's transmit/receive capability. " DEFVAL { twowaysimultaneous } ::= { nwAppnExtEntry 13 } nwAppnExtIfMaxIfrmRcvd OBJECT-TYPE SYNTAX INTEGER (1..127) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum number of I-frames received before an acknowledgment is sent to the sender. " DEFVAL { 4 } ::= { nwAppnExtEntry 14 } nwAppnExtIfDfltTargetPacing OBJECT-TYPE SYNTAX INTEGER (1..32767) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the pacing window size for BINDs on this transmission group. " DEFVAL { 7 } ::= { nwAppnExtEntry 15 } nwAppnExtIfDfltMaxSBtuSize OBJECT-TYPE SYNTAX INTEGER (99..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum Message Unit (MU) size which can be sent. " DEFVAL { 2048 } ::= { nwAppnExtEntry 16 } nwAppnExtIfDfltEffectCap OBJECT-TYPE SYNTAX INTEGER (0..603979776) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the default maximum kilo bits per second rate (line speed) for all links on this port. " ::= { nwAppnExtEntry 17 } nwAppnExtIfDfltConnectCost OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the default cost per connect time for all link stations on this port. 0 is the lowest cost and 255 is the largest cost. " ::= { nwAppnExtEntry 18 } nwAppnExtIfDfltByteCost OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the default Cost per Byte for link stations. 0 is the lowest cost and 255 is the largest cost. " ::= { nwAppnExtEntry 19 } nwAppnExtIfDfltSecurity OBJECT-TYPE SYNTAX INTEGER { nonsecure(1), --X'01' publicSwitchNw(32), --X'20' undergroundCable(64), --X'40' secureConduit(96), --X'60' guardedConduit(128), --X'80' encrypted(160), --X'A0' guardedRadiation(192) --X'C0' } ACCESS read-write STATUS mandatory DESCRIPTION "Specify one of the following security selections: non-secure - specifies no security. public switched - data flows over a public switched network. underground cable - data transmitted over a secure underground cable. secure conduit - line is secure conduit that is not guarded. guarded conduit - conduit that is protected against physical tapping. encrypted - encryption over the line. guarded radiation - line is proected against physical and radiation tapping. " ::= { nwAppnExtEntry 20 } nwAppnExtIfDfltPropDelay OBJECT-TYPE SYNTAX INTEGER { minimum(0), --X'00' negligible(384), --X'4C' terrestrial(9216), --X'71' packetswitched(147456), --X'91' long(294912), --X'99' maximum(2013265920) --X'FF' } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the propagation delay which represents the relative time it takes for a signal to travel the length of the link in microseconds, with some of the more common default values enumerated. The default times in parentheses are in microseconds. These default values fall into the following ranges: minimum - no propagation delay negligible, lan - less than 480 microseconds terrestrial, telephone - between 480 and 49,512 microseconds packetswitched - between 49,512 and 245,760 microseconds long, satellite - more than 245760 microseconds. maximum - the maximum propagation delay. " ::= { nwAppnExtEntry 21 } nwAppnExtIfDfltUsrDef1 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 1. " DEFVAL { 128 } ::= { nwAppnExtEntry 22 } nwAppnExtIfDfltUsrDef2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 2. " DEFVAL { 128 } ::= { nwAppnExtEntry 23 } nwAppnExtIfDfltUsrDef3 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 3. " DEFVAL { 128 } ::= { nwAppnExtEntry 24 } nwAppnExtIfStopType OBJECT-TYPE SYNTAX INTEGER { immediate(1), orderly(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of shutdown for APPN Routing Services on the port. Once set, nwAppnFwdIfAdminStatus may be set to disable. The disable choices are as follows: immediate(1) causes the link stations belonging to the physical port to be disabled immediately without flushing pending messages and without initiating an orderly disconnect sequence. orderly(2) causes pending messages in link stations to be flushed, followed by an orderly disconnect sequence. The link station is then disabled. " DEFVAL { orderly } ::= { nwAppnExtEntry 25 } nwAppnExtIfCpCpSupp OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether CP-CP sessions are permitted on dynamic links generated on this port. " DEFVAL { yes } ::= { nwAppnExtEntry 26 } nwAppnExtIfLimitedRsrc OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether dynamic links generated on this port are a limited resource. A limited resource link will be deactivated when there are no sessions using the link." DEFVAL { no } ::= { nwAppnExtEntry 27 } nwAppnExtIfAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the physical address of this port depending on the media type. For token ring or ethernet ports, the information is the 6 byte MAC address which starts in byte 1 and ends in byte 6. For token ring ports the MAC address must be specified in non- canonical format. For ethernet ports the MAC address must be specified in canonical format. For frame relay ports, there is no associated address, i.e., it will be a zero length octet string." ::= { nwAppnExtEntry 28 } nwAppnExtIfSsap OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "For token ring or ethernet ports specifies the Source SAP Address of this port. " DEFVAL { '04'h } ::= { nwAppnExtEntry 29 } -- -- Connection Network Tables -- nwAppnIfCnPortTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnIfCnPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains definitions for the Connection Network port table which defines which local ports can access a connection network. To add a row to the table, nwAppnIfCnPtFqName and nwAppnIfCnPtName are required entries. To delete a row, set the control field to delete. Adding the first row for a connection network implicitly creates the connection network and deleting the last remaining row for a connection network implicitly removes the connection network." ::= { nwAppnIfCn 1 } nwAppnIfCnPortEntry OBJECT-TYPE SYNTAX NwAppnIfCnPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Specifies the APPN Connection Network port definitions." INDEX { nwAppnIfCnPtFqName, nwAppnIfCnPtName } ::= { nwAppnIfCnPortTable 1 } NwAppnIfCnPortEntry ::= SEQUENCE { nwAppnIfCnPtFqName DisplayString, nwAppnIfCnPtName DisplayString, nwAppnIfCnPtControl INTEGER } nwAppnIfCnPtFqName OBJECT-TYPE SYNTAX DisplayString (SIZE (3..17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the fully-qualified Name of the Virtual Routing Node. The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network identifier and CCCCCCCC is the Control Point name. Valid characters to make up these two strings are uppercase letters A through Z, numerics 0 through 9, and the special characters $, @, and #. The first character of the name must NOT be numeric. Each string must be a maximum length of 8 characters with no embedded spaces and the strings are joined by a dot. " ::= { nwAppnIfCnPortEntry 1 } nwAppnIfCnPtName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies one of the ports which can access this Connection Network." ::= { nwAppnIfCnPortEntry 2 } nwAppnIfCnPtControl OBJECT-TYPE SYNTAX INTEGER { other(1), delete(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set this object to delete to delete this port from this Connection Network." ::= { nwAppnIfCnPortEntry 3 } nwAppnIfCnTgCharTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnIfCnTgCharEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the APPN definitions for a Connection Network's transmission group characteristics. Rows may be neither added nor deleted, only modified. Rows are added/deleted implicitly through CnPortTable." ::= { nwAppnIfCn 2 } nwAppnIfCnTgCharEntry OBJECT-TYPE SYNTAX NwAppnIfCnTgCharEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Specifies the APPN transmission group characteristics for the Connection Network." INDEX { nwAppnIfCnTgFqName } ::= { nwAppnIfCnTgCharTable 1 } NwAppnIfCnTgCharEntry ::= SEQUENCE { nwAppnIfCnTgFqName DisplayString, nwAppnIfCnTgEffectCap INTEGER, nwAppnIfCnTgConnectCost INTEGER, nwAppnIfCnTgByteCost INTEGER, nwAppnIfCnTgSecurity INTEGER, nwAppnIfCnTgPropDelay INTEGER, nwAppnIfCnTgUsrDef1 INTEGER, nwAppnIfCnTgUsrDef2 INTEGER, nwAppnIfCnTgUsrDef3 INTEGER } nwAppnIfCnTgFqName OBJECT-TYPE SYNTAX DisplayString (SIZE (3..17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the fully-qualified Name of the Virtual Routing Node. The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network identifier and CCCCCCCC is the Control Point name. Valid characters to make up these two strings are uppercase letters A through Z, numerics 0 through 9, and the special characters #, $, and @. The first character of the name must NOT be numeric. Each string must be a maximum length of 8 characters with no embedded spaces and the strings are joined by a dot. " ::= { nwAppnIfCnTgCharEntry 1 } nwAppnIfCnTgEffectCap OBJECT-TYPE SYNTAX INTEGER (0..603979776) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum kilo bits per second rate (link speed) for the connection network. " ::= { nwAppnIfCnTgCharEntry 2 } nwAppnIfCnTgConnectCost OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the cost per connect time for the Connection Network. 0 is the lowest cost and 255 is the largest cost." ::= { nwAppnIfCnTgCharEntry 3 } nwAppnIfCnTgByteCost OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the cost per byte for the Connection Network. 0 is the lowest cost and 255 is the largest cost." ::= { nwAppnIfCnTgCharEntry 4 } nwAppnIfCnTgSecurity OBJECT-TYPE SYNTAX INTEGER { nonsecure(1), --X'01' publicSwitchNw(32), --X'20' undergroundCable(64), --X'40' secureConduit(96), --X'60' guardedConduit(128), --X'80' encrypted(160), --X'A0' guardedRadiation(192) --X'C0' } ACCESS read-write STATUS mandatory DESCRIPTION "For the Connection Network, specify one of the following security selections: non-secure - specifies no security. public switched - data flows over a public switched network. underground cable - data transmitted over a secure underground cable. secure conduit - line is secure conduit that is not guarded. guarded conduit - conduit that is protected against physical tapping. encrypted - encryption over the line. guarded radiation - line is proected against physical and radiation tapping. " ::= { nwAppnIfCnTgCharEntry 5 } nwAppnIfCnTgPropDelay OBJECT-TYPE SYNTAX INTEGER { minimum(0), --X'00' negligible(384), --X'4C' terrestrial(9216), --X'71' packetswitched(147456), --X'91' long(294912), --X'99' maximum(2013265920) --X'FF' } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the propagation delay which represents the time it takes for a signal to travel the length of the link in microseconds, with some of the more common default values enumerated. The default times in parentheses are in microseconds. These default values fall into the following ranges: minimum - no propagation delay negligible, lan - less than 480 microseconds terrestrial, telephone - between 480 and 49,512 microseconds packetswitched - between 49,512 and 245,760 microseconds long, satellite - more than 245760 microseconds. maximum - the maximum propagation delay. " ::= { nwAppnIfCnTgCharEntry 6 } nwAppnIfCnTgUsrDef1 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 1. " DEFVAL { 128 } ::= { nwAppnIfCnTgCharEntry 7 } nwAppnIfCnTgUsrDef2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 2. " DEFVAL { 128 } ::= { nwAppnIfCnTgCharEntry 8 } nwAppnIfCnTgUsrDef3 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 3. " DEFVAL { 128 } ::= { nwAppnIfCnTgCharEntry 9 } -- APPN Forwarding Ports Counter Table -- This table contains the objects that specify the Message Unit (MU) and byte -- counters for each port used by APPN Routing Services. -- -- nwAppnFwdIfCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnFwdIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Message Unit (MU) and byte counters for each port configured and enabled for APPN Routing Services. " ::= { nwAppnFwdIfCounters 1 } nwAppnFwdIfCtrEntry OBJECT-TYPE SYNTAX NwAppnFwdIfCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry indicates Message Units (MU) and byte counts on the router port for which this entry exists." INDEX { nwAppnFwdIfCtrIfIndex } ::= { nwAppnFwdIfCtrTable 1 } NwAppnFwdIfCtrEntry ::= SEQUENCE { nwAppnFwdIfCtrIfIndex INTEGER, nwAppnFwdIfCtrAdminStatus INTEGER, nwAppnFwdIfCtrReset INTEGER, nwAppnFwdIfCtrOperationalTime TimeTicks, nwAppnFwdIfCtrInMus Counter, nwAppnFwdIfCtrOutMus Counter, nwAppnFwdIfCtrFwdMus Counter, nwAppnFwdIfCtrFilteredMus Counter, nwAppnFwdIfCtrDiscardMus Counter, nwAppnFwdIfCtrAddrErrMus Counter, nwAppnFwdIfCtrLenErrMus Counter, nwAppnFwdIfCtrHdrErrMus Counter, nwAppnFwdIfCtrInBytes Counter, nwAppnFwdIfCtrOutBytes Counter, nwAppnFwdIfCtrFwdBytes Counter, nwAppnFwdIfCtrFilteredBytes Counter, nwAppnFwdIfCtrDiscardBytes Counter, nwAppnFwdIfCtrHostInMus Counter, nwAppnFwdIfCtrHostOutMus Counter, nwAppnFwdIfCtrHostDiscardMus Counter, nwAppnFwdIfCtrHostInBytes Counter, nwAppnFwdIfCtrHostOutBytes Counter, nwAppnFwdIfCtrHostDiscardBytes Counter } nwAppnFwdIfCtrIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the value of MIB 2 ifindex, which identifies the router port for which the entry exists. This is the primary index into the APPN per-port counter table. " ::= { nwAppnFwdIfCtrEntry 1 } nwAppnFwdIfCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the per-port Message Unit (MU) and byte counters on the router port for which the entry exists. enabled(3) causes these counters to become active. disabled(2) causes these counters to become inactive." ::= { nwAppnFwdIfCtrEntry 2 } nwAppnFwdIfCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the per-port Message Unit (MU) and byte counters on the router port for which this entry exists. reset (2) resets the counters to 0. nwAppnFwdIfCtrOperationalTime is also reset to 0." ::= { nwAppnFwdIfCtrEntry 3 } nwAppnFwdIfCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the amount of time in hundreths of a second that the per-port Message Unit (MU) and byte counters have been active on the APPN routing services port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 4 } nwAppnFwdIfCtrInMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MU)s that have been received, during nwAppnFwdIfCtrOperationaltime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 5 } nwAppnFwdIfCtrOutMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MU)s that have been transmitted, during nwAppnFwdIfCtrOperationalTime, on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 6 } nwAppnFwdIfCtrFwdMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MU)s that have been forwarded during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 7 } nwAppnFwdIfCtrFilteredMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdIfCtrEntry 8 } nwAppnFwdIfCtrDiscardMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdIfCtrEntry 9 } nwAppnFwdIfCtrAddrErrMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that contain an address error in the SNA header that have been received during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 10 } nwAppnFwdIfCtrLenErrMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that contain a length error that have been received during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 11 } nwAppnFwdIfCtrHdrErrMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that contain a header error other than an address or length error that have been received during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 12 } nwAppnFwdIfCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the Message Units (MU)s that have been received, during nwAppnFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwAppnFwdIfCtrEntry 13 } nwAppnFwdIfCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in the Message Units (MU)s that have been transmitted, during nwAppnFwdIfCtrOperationalTime, on the router port for which the entry exists." ::= { nwAppnFwdIfCtrEntry 14 } nwAppnFwdIfCtrFwdBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in Message Units (MU)s that have been forwarded during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 15 } nwAppnFwdIfCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdIfCtrEntry 16 } nwAppnFwdIfCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdIfCtrEntry 17 } nwAppnFwdIfCtrHostInMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that have been delivered to local half sessions during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 18 } nwAppnFwdIfCtrHostOutMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of Message Units (MUs) that have been successfully sent from local half sessions to Path Control during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 19 } nwAppnFwdIfCtrHostDiscardMus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdIfCtrEntry 20 } nwAppnFwdIfCtrHostInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in Message Units (MUs) that have been delivered to local half sessions during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 21 } nwAppnFwdIfCtrHostOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of bytes in Message Units (MUs) that have been successfully sent from local half sessions to Path Control during nwAppnFwdIfCtrOperationalTime on the router port for which this entry exists." ::= { nwAppnFwdIfCtrEntry 22 } nwAppnFwdIfCtrHostDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdIfCtrEntry 23 } -- APPN Forwarding Adjacent Link Station Table -- This table contains the managed objects used to set up and configure -- links to adjacent link stations. Only those links that are configured by the -- user can be modified. Links which are active cannot be modified. -- If an attempt is made to modify an active link, the operational status -- will indicate busy-failed. nwAppnFwdLsTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnFwdLsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the configuration and management information for links to adjacent link stations. This table is indexed by nwAppnFwdLsName. Operations which apply are add, delete, modify, enable, and disable. To add a row to the table, the required fields in the row must be provided. The required fields are nwAppnFwdLsPortName and nwAppnFwdLsDestAddr. All other fields which are not provided will be defaulted. To enable a link select enable(3) from nwAppnFwdLsAdminStatus. To delete a row, set nwAppnFwdLsControl to delete(3). To disable a link set nwAppnFwdLsStopType and then select disable(2) in nwAppnFwdLsAdminStatus. If nwAppnFwdLsStopType is not selected, the link is disabled in an orderly fashion. " ::= { nwAppnFwdLsConfig 1 } nwAppnFwdLsEntry OBJECT-TYPE SYNTAX NwAppnFwdLsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Specifies the configuration for a link to an adjacent link station for which the entry exists." INDEX { nwAppnFwdLsName } ::= { nwAppnFwdLsTable 1 } NwAppnFwdLsEntry ::= SEQUENCE { nwAppnFwdLsName DisplayString, nwAppnFwdLsAdminStatus INTEGER, nwAppnFwdLsOperStatus INTEGER, nwAppnFwdLsOperationalTime TimeTicks, nwAppnFwdLsControl INTEGER, nwAppnFwdLsPortName DisplayString, nwAppnFwdLsAdjCpName DisplayString, nwAppnFwdLsAdjCpType INTEGER, nwAppnFwdLsAutoActSupport INTEGER, nwAppnFwdLsLimitedRsrc INTEGER, nwAppnFwdLsSscpSession INTEGER, nwAppnFwdLsPuName DisplayString, nwAppnFwdLsBackLvlLenEN INTEGER, nwAppnFwdLsCpCpSessSupp INTEGER, nwAppnFwdLsEffectCap INTEGER, nwAppnFwdLsConnectCost INTEGER, nwAppnFwdLsByteCost INTEGER, nwAppnFwdLsSecurity INTEGER, nwAppnFwdLsPropDelay INTEGER, nwAppnFwdLsUsrDef1 INTEGER, nwAppnFwdLsUsrDef2 INTEGER, nwAppnFwdLsUsrDef3 INTEGER, nwAppnFwdLsTrgtPacingCount INTEGER, nwAppnFwdLsMaxSendBtu INTEGER, nwAppnFwdLsNumActiveSession INTEGER, nwAppnFwdLsdynamicLs INTEGER, nwAppnFwdLsStopType INTEGER, nwAppnFwdLsPortNbr INTEGER, nwAppnFwdLsDestAddr OCTET STRING, nwAppnFwdLsDsap OCTET STRING, nwAppnFwdLsBlockNum DisplayString, nwAppnFwdLsIdNum DisplayString } nwAppnFwdLsName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the primary index to the adjacent link station table (nwAppnFwdLsTable). " ::= { nwAppnFwdLsEntry 1 } nwAppnFwdLsAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of a link to an adjacent link station. enabled(3) causes the link to become established. disable(2) causes the link to terminate. There are various severities of disabling a link which are selected via the leaf node nwAppnFwdLsStopType described further within this branch. " ::= { nwAppnFwdLsEntry 2 } nwAppnFwdLsOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- inactive enabled(3), -- active pendingDisable(4), -- deactivate in progress pendingEnable(5) -- activate in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current operating status of the link for which this entry exists." ::= { nwAppnFwdLsEntry 3 } nwAppnFwdLsOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the elapsed time, in hundredths of a second, that nwAppnFwdLsAdminStatus has been either enabled or DISABLED. If the operational state is pending-disable, nwAppnFwdLsOperationalTime indicates the amount of time since the state was enabled. If the operational state is pending-enable, nwAppnFwdLsOperationalTime indicates the amount of time since the state was DISABLED." ::= { nwAppnFwdLsEntry 4 } nwAppnFwdLsControl OBJECT-TYPE SYNTAX INTEGER { other(1), delete(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set this object to delete in order to delete the entry." ::= { nwAppnFwdLsEntry 5 } nwAppnFwdLsPortName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "This link station port name corresponds to the port name index into the the nwAppnExtensionTable which describes the router port on which the adjacent link station is defined." ::= { nwAppnFwdLsEntry 6 } nwAppnFwdLsAdjCpName OBJECT-TYPE SYNTAX DisplayString (SIZE (3..17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the fully-qualified, 17 byte long, adjacent Control Point name. The name format is NNNNNNNN.CCCCCCCC where NNNNNNNN is the network identifier and CCCCCCCC is the Control Point name. Valid characters to make up these two strings are uppercase letters A through Z, numerics 0 through 9, and the special characters $, # and @. The first character of the name must NOT be numeric. Each string must be a maximum length of 8 characters with no embedded spaces and the strings are joined by a dot. " ::= { nwAppnFwdLsEntry 7 } nwAppnFwdLsAdjCpType OBJECT-TYPE SYNTAX INTEGER { endnode(1), networknode(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the adjacent node type. The following values are valid: endnode(1), networknode(2). endnode(1) includes both End Node and LEN node types." DEFVAL { endnode } ::= { nwAppnFwdLsEntry 8 } nwAppnFwdLsAutoActSupport OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the link is automatically enabled when a session is activated over the link. It is an error to set this to yes(1) when nwAppnFwdLsCpCpSessSupp is set to yes(1). " DEFVAL { no } ::= { nwAppnFwdLsEntry 10 } nwAppnFwdLsLimitedRsrc OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether this link is to be deactivated when there are no sessions using the link. If nwAppnFwdLsCpCpSessSupp is yes, however, the link will not be deactivated if CP-CP sessions are terminated. Note also that a link over a non-switched port cannot be configured as a limited resource." DEFVAL { no } ::= { nwAppnFwdLsEntry 11 } nwAppnFwdLsSscpSession OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Requests a host system to initiate sessions between its SSCP and dependent LUs within APPN Routing Services. If set to yes, then nwAppnFwdLsPuName is required. Note: once this parameter is set along with other link station parameters associated with a link station definition, it cannot be modified. In order to change it, the link station definition itself must be deleted and then redefined with the new parameter." DEFVAL { no } ::= { nwAppnFwdLsEntry 12 } nwAppnFwdLsPuName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the name of the local PU if nwAppnFwdLsSscpSession is set to yes. Valid characters are uppercase A through Z and numerics 0 through 9. The name must start with an alphabetic character. Note: once this parameter is set along with other link station parameters associated with a link station definition, it cannot be modified. In order to change it, the link station definition itself must be deleted and then redefined with the new parameter." ::= { nwAppnFwdLsEntry 13 } nwAppnFwdLsBackLvlLenEN OBJECT-TYPE SYNTAX INTEGER { no(1), xid3(2), xid0(3), noxid(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether or not the adjacent node is a back level LEN Node. If so, specify the type of back level LEN node as follows: xid3(2) - supports XID-3 protocols, but does not include Network Name control vector in the XID. xid0(3) - Supports XID-0 protocols. Not valid if nwAppnExtIfLocalLsRole is negotiable(1). noxid(4) - Does not support XID protocols. Valid only if nwAppnExtIfPortType is nonswitched(1) and not valid if nwAppnExtIfLocalLsRole is negotiable(1). If not no(1), then nwAppnFwdLsAdjCpName and nwAppnFwdLsIdNum must be specified. " DEFVAL { no } ::= { nwAppnFwdLsEntry 14 } nwAppnFwdLsCpCpSessSupp OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether this link supports CP to CP sessions." DEFVAL { yes } ::= { nwAppnFwdLsEntry 16 } nwAppnFwdLsEffectCap OBJECT-TYPE SYNTAX INTEGER (0..603979776) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies th maximum kilo bits per second rate (link speed) for the link. " ::= { nwAppnFwdLsEntry 17 } nwAppnFwdLsConnectCost OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the cost per connect time for the link. Zero is the lowest cost and 255 is the largest cost." ::= { nwAppnFwdLsEntry 18 } nwAppnFwdLsByteCost OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the cost per Byte for the link. Zero is the lowest cost and 255 is the largest cost." ::= { nwAppnFwdLsEntry 19 } nwAppnFwdLsSecurity OBJECT-TYPE SYNTAX INTEGER { nonsecure(1), --X'01' publicSwitchNw(32), --X'20' undergroundCable(64), --X'40' secureConduit(96), --X'60' guardedConduit(128), --X'80' encrypted(160), --X'A0' guardedRadiation(192) --X'C0' } ACCESS read-write STATUS mandatory DESCRIPTION "Security selections available for the link are as follows: non-secure - specifies no security. public switched - data flows over a public switched network. underground cable - data transmitted over a secure underground cable. secure conduit - line is secure conduit that is not guarded. guarded conduit - conduit that is protected against physical tapping. encrypted - encryption over the line. guarded radiation - line is proected against physical and radiation tapping. " ::= { nwAppnFwdLsEntry 20 } nwAppnFwdLsPropDelay OBJECT-TYPE SYNTAX INTEGER { minimum(0), --X'00' negligible(384), --X'4C' terrestrial(9216), --X'71' packetswitched(147456), --X'91' long(294912), --X'99' maximum(2013265920) --X'FF' } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the propagation delay which represents the relative time it takes for a signal to travel the length of the link in microseconds, with some of the more common default values enumerated. The default times in parentheses are in microseconds. These default values fall into the following ranges: minimum - no propagation delay negligible, lan - less than 480 microseconds terrestrial, telephone - between 480 and 49,512 microseconds packetswitched - between 49,512 and 245,760 microseconds long, satellite - more than 245760 microseconds. maximum - the maximum propagation delay. " ::= { nwAppnFwdLsEntry 21 } nwAppnFwdLsUsrDef1 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 1. " DEFVAL { 128 } ::= { nwAppnFwdLsEntry 22 } nwAppnFwdLsUsrDef2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 2. " DEFVAL { 128 } ::= { nwAppnFwdLsEntry 23 } nwAppnFwdLsUsrDef3 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies user defined parameter 3. " DEFVAL { 128 } ::= { nwAppnFwdLsEntry 24 } nwAppnFwdLsTrgtPacingCount OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-write STATUS mandatory DESCRIPTION "Species the desired pacing window size for BINDs on this transmission group. The number is a value between 0 and 32767 and is significant only when fixed bind pacing is being used." DEFVAL { 7 } ::= { nwAppnFwdLsEntry 25 } nwAppnFwdLsMaxSendBtu OBJECT-TYPE SYNTAX INTEGER (99..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies maximum Message Unit (MU) size that can be sent." DEFVAL { 2048 } ::= { nwAppnFwdLsEntry 26 } nwAppnFwdLsNumActiveSession OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies total number of active sessions on this link. This includes both end point sessions and intermediate sessions." ::= { nwAppnFwdLsEntry 27 } nwAppnFwdLsdynamicLs OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies whether this link station was dynamically allocated (yes(1)) or whether the link station was defined by the user (no(2))." ::= { nwAppnFwdLsEntry 28 } nwAppnFwdLsStopType OBJECT-TYPE SYNTAX INTEGER { immediate(1), orderly(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of shutdown for a link. Once selected, set disable in nwAppnFwdIfAdminStatus. The shutdown choices are as follows: immediate(1) causes the link station to disconnect immediately without flushing remaining Message Unit (MU)s. orderly(2) causes the link station to disconnect after successfully flushing remaining Message Unit (MU)s. " DEFVAL { orderly } ::= { nwAppnFwdLsEntry 29 } nwAppnFwdLsPortNbr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This link station port number corresponds to the index into the nwAppnFwdIfTable and the nwAppnExtensionTable, which together describe the port used by APPN Routing Services." ::= { nwAppnFwdLsEntry 30 } nwAppnFwdLsDestAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the destination address of the adjacent link station depending on the media type. For token ring or ethernet ports, the information is the 6 byte Destination MAC Address which starts in byte 1 and ends in byte 6. For token ring ports, the MAC address must be specified in non-canonical format. For ethernet ports the MAC address must be specified in canonical format. For frame relay, the address is a non-null terminated string which is the ascii representation of the DLCI." ::= { nwAppnFwdLsEntry 31 } nwAppnFwdLsDsap OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "For a token ring or ethernet network, specifies the destination SAP address associated with the adjacent link station. " DEFVAL { '04'h } ::= { nwAppnFwdLsEntry 32 } nwAppnFwdLsBlockNum OBJECT-TYPE SYNTAX DisplayString (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "This represents the 3 hexadecimal digit block number which precedes the 5 digit id number in the 8 digit node id of the adjacent node. The node id is used in XIDs and Alerts. The block number identifies the product type. Both the block number and id number combined, uniquely identify the adjacent node within the installation network." ::= { nwAppnFwdLsEntry 33 } nwAppnFwdLsIdNum OBJECT-TYPE SYNTAX DisplayString (SIZE(5)) ACCESS read-write STATUS mandatory DESCRIPTION "This represents the 5 hexadecimal digit id number which follows the 3 digit block number in the 8 digit node id of the adjacent node. The node id is used in XIDs and Alerts. The id number uniquely identifies the adjacent node within a product type indicated by its block number. Both the block number and id number combined, uniquely identify the adjacent node within the installation network." ::= { nwAppnFwdLsEntry 34 } -- APPN Forwarding Link Station Counter Table -- APPN Forwarding link station Counter Table -- This table contains the objects that specify Basic Link Unit (BLU) and -- byte counters for each configured adjacent link station. -- nwAppnFwdLsCtrTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnFwdLsCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Basic Link Unit (BLU) and byte counters for each configured adjacent link station." ::= { nwAppnFwdLsCounters 1 } nwAppnFwdLsCtrEntry OBJECT-TYPE SYNTAX NwAppnFwdLsCtrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry indicates the Basic Link Unit (BLU) and byte count for the configured adjacent link station for which the entry exists. " INDEX { nwAppnFwdLsCtrLsName } ::= { nwAppnFwdLsCtrTable 1 } NwAppnFwdLsCtrEntry ::= SEQUENCE { nwAppnFwdLsCtrLsName DisplayString, nwAppnFwdLsCtrAdminStatus INTEGER, nwAppnFwdLsCtrReset INTEGER, nwAppnFwdLsCtrOperationalTime TimeTicks, nwAppnFwdLsCtrInBlus Counter, nwAppnFwdLsCtrOutBlus Counter, nwAppnFwdLsCtrFwdBlus Counter, nwAppnFwdLsCtrFilteredBlus Counter, nwAppnFwdLsCtrDiscardBlus Counter, nwAppnFwdLsCtrAddrErrBlus Counter, nwAppnFwdLsCtrLenErrBlus Counter, nwAppnFwdLsCtrHdrErrBlus Counter, nwAppnFwdLsCtrInBytes Counter, nwAppnFwdLsCtrOutBytes Counter, nwAppnFwdLsCtrFwdBytes Counter, nwAppnFwdLsCtrFilteredBytes Counter, nwAppnFwdLsCtrDiscardBytes Counter, nwAppnFwdLsCtrHostInBlus Counter, nwAppnFwdLsCtrHostOutBlus Counter, nwAppnFwdLsCtrHostDiscardBlus Counter, nwAppnFwdLsCtrHostInBytes Counter, nwAppnFwdLsCtrHostOutBytes Counter, nwAppnFwdLsCtrHostDiscardBytes Counter } nwAppnFwdLsCtrLsName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the primary index into the link station counter table. This index is the link station name. " ::= { nwAppnFwdLsCtrEntry 1 } nwAppnFwdLsCtrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the administrative state of the Basic Link Unit (BLU) and byte counters on the link for which this entry exists. enabled(3) causes these counters to reset and become active. disabled(2) causes these counters to become inactive. " ::= { nwAppnFwdLsCtrEntry 2 } nwAppnFwdLsCtrReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Resets the Basic Link Unit (BLU) and byte counters on the link for which this entry exists. reset(2) resets the counters to 0. nwAppnFwdLsCtrOperationalTime is also reset to 0." ::= { nwAppnFwdLsCtrEntry 3 } nwAppnFwdLsCtrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the amount of time in hundreths of a second that the Basic Link Unit (BLU) and byte counters have been active on the link for which this entry exists." ::= { nwAppnFwdLsCtrEntry 4 } nwAppnFwdLsCtrInBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the total number of Basic Link Unit (BLU)s that have been received, during nwAppnFwdLsCtrOperationaltime, on the link for which this entry exists. This includes both information (I-frame) and XID BLUs." ::= { nwAppnFwdLsCtrEntry 5 } nwAppnFwdLsCtrOutBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the total number of Basic Link Unit (BLU)s that have been transmitted, during nwAppnFwdLsCtrOperationalTime, on the link for which this entry exists. This includes both information (I-frame) and XID BLUs." ::= { nwAppnFwdLsCtrEntry 6 } nwAppnFwdLsCtrFwdBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 7 } nwAppnFwdLsCtrFilteredBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 8 } nwAppnFwdLsCtrDiscardBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 9 } nwAppnFwdLsCtrAddrErrBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 10 } nwAppnFwdLsCtrLenErrBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the total number of received Basic Link Unit (BLU)s during nwAppnFwdLsCtrOperationalTime which have invalid DLC headers on the link for which this entry exists." ::= { nwAppnFwdLsCtrEntry 11 } nwAppnFwdLsCtrHdrErrBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the total number of received Basic Link Unit (BLU)s during nwAppnFwdLsCtrOperationalTime which have length errors on the link for which this entry exists." ::= { nwAppnFwdLsCtrEntry 12 } nwAppnFwdLsCtrInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the total number of bytes that have been received, during nwAppnFwdLsCtrOperationalTime, on the link for which the entry exists. This includes bytes contained in information (I-frames) and XID BLUs." ::= { nwAppnFwdLsCtrEntry 13 } nwAppnFwdLsCtrOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the total number of bytes that have been transmitted, during nwAppnFwdLsCtrOperationalTime, on the link for which the entry exists. This includes bytes contained in information (I-frames) and XID BLUs." ::= { nwAppnFwdLsCtrEntry 14 } nwAppnFwdLsCtrFwdBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 15 } nwAppnFwdLsCtrFilteredBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 16 } nwAppnFwdLsCtrDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 17 } nwAppnFwdLsCtrHostInBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 18 } nwAppnFwdLsCtrHostOutBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 19 } nwAppnFwdLsCtrHostDiscardBlus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 20 } nwAppnFwdLsCtrHostInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 21 } nwAppnFwdLsCtrHostOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 22 } nwAppnFwdLsCtrHostDiscardBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnFwdLsCtrEntry 23 } -- Link State-Based Protocols -- This group contains the managed objects for Link State protocols for -- APPN Routing Services. -- APPN ISR System Group -- This group contains the managed objects for global, system-wide -- APPN Intermediate Session Routing (ISR) LinkState based routing protocol. -- APPN ISR System Configuration Parameters -- This group contains the objects that pertain to the setup and -- configuration of the APPN ISR LinkState based routing protocol. -- Link State-Based Protocols -- This group contains the objects that apply to the Link State based routing -- protocols supported by APPN Routing Services. -- APPN ISR System Group -- This group contains the objects that pertain to the APPN Intermediate Session -- Routing (ISR) LinkState-based routing protocol at a system-wide, global level. -- APPN ISR System Configuration Parameters -- This group contains the objects that pertain to the setup and configuration -- of the APPN ISR Link State based routing protocol at a system-wide, global level. nwAppnIsrAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disable(2), -- disable enable(3) -- enable } ACCESS read-write STATUS mandatory DESCRIPTION "Intermediate Session Routing cannot be turned on and off. Any modifications to this leaf will have no affect. " ::= { nwAppnIsrConfig 1 } nwAppnIsrOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following disabled(2), -- inactive enabled(3), -- active pendingDisable(4), -- deactivate in progress pendingEnable(5) -- activate in progress } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current operating condition of the ISR routing protocol, system-wide." ::= { nwAppnIsrConfig 2 } nwAppnIsrAdminReset OBJECT-TYPE SYNTAX INTEGER { other(1) -- none of the following } ACCESS read-only STATUS mandatory DESCRIPTION "This object does not apply to this protocol. It is a common object, inherited from the MIB framework used to provide a common management interface to all the Cabletron Routing Services protocol-specific MIBs." ::= { nwAppnIsrConfig 3 } nwAppnIsrOperationalTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the elapsed time, in hundredths of a second, that nwAppnOperStatus has been in its current state." ::= { nwAppnIsrConfig 4 } nwAppnIsrVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current revision level of the ISR firmware in textual format. This is the same version number as that of APPN Routing Services firmware, nwAppnSysVersion. " ::= { nwAppnIsrConfig 5 } -- APPN Event Group nwAppnEventAdminStatus OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set the administrative state of APPN Routing Services event logging. enabled(3) causes the event log to become active. disabled(2) causes the event log to become inactive." ::= { nwAppnEventLogConfig 1 } nwAppnEventMaxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the maximum number of entries allowed in the event log table. When the number of entries reaches the value of nwAppnEventMaxEntries the first (oldest) entry is deleted to allow a new entry to be added." ::= { nwAppnEventLogConfig 2 } nwAppnEventTraceAll OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "enabled(3) allows logging of all event types on all ports. disabled(2) causes the filter table to specify which events to log." ::= { nwAppnEventLogConfig 3 } -- Event Log Filter Table -- The Event Log Filter Table contains the managed objects used to setup -- and configure event log filters for APPN Routing Services events. nwAppnEventFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnEventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains descriptions of how to filter log entries." ::= { nwAppnEventLogFilterTable 1 } nwAppnEventFilterEntry OBJECT-TYPE SYNTAX NwAppnEventFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies the filter for log entries. The instance nwAppnEventProtocol refers to the instance used in the nwRtgProtocolTable and nwComponentTable specified by the ctrouter-mib.txt. " INDEX { nwAppnEventFltrProtocol, nwAppnEventFltrIfNum } ::= { nwAppnEventFilterTable 1 } NwAppnEventFilterEntry ::= SEQUENCE { nwAppnEventFltrProtocol INTEGER, nwAppnEventFltrIfNum INTEGER, nwAppnEventFltrControl INTEGER, nwAppnEventFltrType INTEGER, nwAppnEventFltrSeverity INTEGER, nwAppnEventFltrAction INTEGER } nwAppnEventFltrProtocol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the protocol to log events from." ::= { nwAppnEventFilterEntry 1 } nwAppnEventFltrIfNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the APPN Routing Services port on which to log events. " ::= { nwAppnEventFilterEntry 2 } nwAppnEventFltrControl OBJECT-TYPE SYNTAX INTEGER { other(1), delete(2), add(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this field to delete will allow entries to be removed from the table. This is done by adding new entries with instance fields that match the entry to be removed from the table. The new entry being added must have this control field set to delete in order for the matching entry already in the table to be deleted. Setting this field to add will add the entry to the table." ::= { nwAppnEventFilterEntry 3 } nwAppnEventFltrType OBJECT-TYPE SYNTAX INTEGER { misc(1), timer(2), rcv(4), xmit(8), event(16), error(32) } ACCESS read-write STATUS mandatory DESCRIPTION "This bit field mask filter will allow only events of certain types to be logged. By default all types will be logged. Clearing event types from this field will cause those types not to be logged. Adding event types to this field will enable those types to be logged. " ::= { nwAppnEventFilterEntry 4 } nwAppnEventFltrSeverity OBJECT-TYPE SYNTAX INTEGER { highest(1), highmed(2), highlow(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This filter controls the amount of logging by ignoring events of lower priority than that specified by the filter value. Specifying highest(1) causes all events except those of highest severity to be ignored. Specifying highmed(2) causes lowest severity events to be ignored. Specifying highlow(3) causes all events to be logged. highmed(2) is the default setting." ::= { nwAppnEventFilterEntry 5 } nwAppnEventFltrAction OBJECT-TYPE SYNTAX INTEGER { log(1), trap(2), logTrap(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This field specifies how the events are to be logged. Specifying log(1) stores the events in the event log table (defined below). Specifying trap(2) sends events out through the trap mechanism. Specifying logTrap(3) does both. " ::= { nwAppnEventFilterEntry 6 } -- Event Log Table -- The Event Log Table contains the logged events. nwAppnEventTable OBJECT-TYPE SYNTAX SEQUENCE OF NwAppnEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains all events that have been logged." ::= { nwAppnEventLogTable 1 } nwAppnEventEntry OBJECT-TYPE SYNTAX NwAppnEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry specifies events that have been logged." INDEX { nwAppnEventNumber } ::= { nwAppnEventTable 1 } NwAppnEventEntry ::= SEQUENCE { nwAppnEventNumber INTEGER, nwAppnEventTime TimeTicks, nwAppnEventType INTEGER, nwAppnEventSeverity INTEGER, nwAppnEventProtocol INTEGER, nwAppnEventIfNum INTEGER, nwAppnEventTextString OCTET STRING } nwAppnEventNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This ordinal number uniquely identifies events." ::= { nwAppnEventEntry 1 } nwAppnEventTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This number specifies when the event was logged." ::= { nwAppnEventEntry 2 } nwAppnEventType OBJECT-TYPE SYNTAX INTEGER { misc(1), timer(2), rcv(4), xmit(8), event(16), diags(32), error(64) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies type of event logged." ::= { nwAppnEventEntry 3 } nwAppnEventSeverity OBJECT-TYPE SYNTAX INTEGER { highest(1), highmed(2), highlow(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the severity of the event logged." ::= { nwAppnEventEntry 4 } nwAppnEventProtocol OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the protocol where the event occured." ::= { nwAppnEventEntry 5 } nwAppnEventIfNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the APPN Routing Services port the event occurred on." ::= { nwAppnEventEntry 6 } nwAppnEventTextString OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the actual text string to be logged." ::= { nwAppnEventEntry 7 } END