-- -- WWP-8021X-MIB.my -- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88 -- Sunday, August 28, 2005 at 19:49:14 -- WWP-8021X-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC wwpModules FROM WWP-SMI; -- 1.3.6.1.4.1.6141.2.401 wwp8021xMibModule MODULE-IDENTITY LAST-UPDATED "200508281935Z" -- August 28, 2005 at 19:35 GMT ORGANIZATION "World Wide Packets, Inc" CONTACT-INFO " Mib Meister Postal: World Wide Packets P.O. Box 950 Veradale, WA 99037 USA Phone: +1 509 242 9000 Email: mib.meister@worldwidepackets.com" DESCRIPTION "Description." ::= { wwpModules 401 } -- -- Node definitions -- -- 1.3.6.1.4.1.6141.2.401.1 wwp8021xMIB OBJECT IDENTIFIER ::= { wwp8021xMibModule 1 } -- 1.3.6.1.4.1.6141.2.401.1.1 wwp8021xConf OBJECT IDENTIFIER ::= { wwp8021xMIB 1 } -- 1.3.6.1.4.1.6141.2.401.1.1.1 wwp8021xGroups OBJECT IDENTIFIER ::= { wwp8021xConf 1 } -- 1.3.6.1.4.1.6141.2.401.1.1.1.1 -- wwp8021xObjectGroup OBJECT-GROUP -- OBJECTS { object1 } -- STATUS current -- DESCRIPTION -- "Description." -- ::= { wwp8021xGroups 1 } -- 1.3.6.1.4.1.6141.2.401.1.1.1.2 -- wwp8021xNotificationGroup NOTIFICATION-GROUP -- NOTIFICATIONS { notification1 } -- STATUS current -- DESCRIPTION -- "Description." -- ::= { wwp8021xGroups 2 } -- 1.3.6.1.4.1.6141.2.401.1.1.2 wwp8021xCompls OBJECT IDENTIFIER ::= { wwp8021xConf 2 } -- 1.3.6.1.4.1.6141.2.401.1.2 wwp8021xObjs OBJECT IDENTIFIER ::= { wwp8021xMIB 2 } -- 1.3.6.1.4.1.6141.2.401.1.2.1 wwp8021xPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Wwp8021xPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table with an entry for every port on the switch" ::= { wwp8021xObjs 1 } -- 1.3.6.1.4.1.6141.2.401.1.2.1.1 wwp8021xPortEntry OBJECT-TYPE SYNTAX Wwp8021xPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { wwp8021xPort } ::= { wwp8021xPortTable 1 } Wwp8021xPortEntry ::= SEQUENCE { wwp8021xPort INTEGER, wwp8021xRole INTEGER } -- 1.3.6.1.4.1.6141.2.401.1.2.1.1.1 wwp8021xPort OBJECT-TYPE SYNTAX INTEGER (1..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Switch Ethernet Port" ::= { wwp8021xPortEntry 1 } -- 1.3.6.1.4.1.6141.2.401.1.2.1.1.2 wwp8021xRole OBJECT-TYPE SYNTAX INTEGER { none(1), supplicant(2), authenticator(3), both(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "802.1x role of the Port." ::= { wwp8021xPortEntry 2 } -- Radius configuration -- 1.3.6.1.4.1.6141.2.401.1.2.2 wwp8021xRadiusClient OBJECT IDENTIFIER ::= { wwp8021xObjs 2 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.1 wwp8021xRadiusClientTimeout OBJECT-TYPE SYNTAX Integer32 (1..30) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is the time in seconds between retransmissions to the RADIUS server." DEFVAL { 1 } ::= { wwp8021xRadiusClient 1 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.2 wwp8021xRadiusClientRetries OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the number of times the RADIUS server should be tried before giving up on the server." DEFVAL { 3 } ::= { wwp8021xRadiusClient 2 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.3 wwp8021xRadiusDeadTime OBJECT-TYPE SYNTAX Integer32 (0..2000) UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "Length of time in minutes during which a RADIUS server is skipped over by transaction requests.." DEFVAL { 60 } ::= { wwp8021xRadiusClient 3 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.4 wwp8021xRadiusServerTable OBJECT-TYPE SYNTAX SEQUENCE OF Wwp8021xRadiusServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Lists the possible RADIUS servers." ::= { wwp8021xRadiusClient 4 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.4.1 wwp8021xRadiusServerEntry OBJECT-TYPE SYNTAX Wwp8021xRadiusServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radius server entry." INDEX { wwp8021xRadiusServerId } ::= { wwp8021xRadiusServerTable 1 } Wwp8021xRadiusServerEntry ::= SEQUENCE { wwp8021xRadiusServerId Integer32, wwp8021xRadiusServerIpAddr IpAddress, wwp8021xRadiusServerAuthPort Integer32, wwp8021xRadiusServerAuthKey OCTET STRING, wwp8021xRadiusServerStatus RowStatus } -- 1.3.6.1.4.1.6141.2.401.1.2.2.4.1.1 wwp8021xRadiusServerId OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the Radius Server Entry. The radius Servers are polled according to their ServerIds. If the ServerId 1 doesn't respond, then it tries for the next and hence on." ::= { wwp8021xRadiusServerEntry 1 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.4.1.2 wwp8021xRadiusServerIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP Address of the RADIUS server." ::= { wwp8021xRadiusServerEntry 2 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.4.1.3 wwp8021xRadiusServerAuthPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The destination UDP port number to which RADIUS messages should be sent. The RADIUS server will not be used for authentication if this port number is 0." DEFVAL { 1812 } ::= { wwp8021xRadiusServerEntry 3 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.4.4 wwp8021xRadiusServerAuthKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..127)) MAX-ACCESS read-create STATUS current DESCRIPTION "The Auth Key to be used for Radius Servers. Retrieving the value of this object via SNMP will return an empty string for security reasons" ::= { wwp8021xRadiusServerEntry 4 } -- 1.3.6.1.4.1.6141.2.401.1.2.2.4.5 wwp8021xRadiusServerStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "To create a row in this table, a manager must set this object to either createAndGo(4). A row in the WwpRadiusServerEntry can't be set to active until wwpRadiusServerIpAddr has been set to valid value. To disable a Radius server , the operator can set this object to 'notInSerVice' state." ::= { wwp8021xRadiusServerEntry 5 } -- 1.3.6.1.4.1.6141.2.401.1.3 wwp8021xEvents OBJECT IDENTIFIER ::= { wwp8021xMIB 3 } -- 1.3.6.1.4.1.6141.2.401.1.3.0 wwp8021xEventsV2 OBJECT IDENTIFIER ::= { wwp8021xEvents 0 } -- 1.3.6.1.4.1.6141.2.401.1.2.3 wwp8021xSupplicantSecTable OBJECT-TYPE SYNTAX SEQUENCE OF Wwp8021xSupplicantSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for Supplicant username and password. Has entry for every port on the switch" ::= { wwp8021xObjs 3 } -- 1.3.6.1.4.1.6141.2.401.1.2.3.1 wwp8021xSupplicantSecEntry OBJECT-TYPE SYNTAX Wwp8021xSupplicantSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This contains the username and password entries for each port. Index is wwp8021xPort from Wwp8021xPortEntry" INDEX { wwp8021xPort } ::= { wwp8021xSupplicantSecTable 1 } Wwp8021xSupplicantSecEntry ::= SEQUENCE { wwp8021xPort INTEGER, wwp8021xSupplicantSecUserName OCTET STRING, wwp8021xSupplicantSecPassword OCTET STRING } -- 1.3.6.1.4.1.6141.2.401.1.2.3.1.1 wwp8021xSupplicantSecUserName OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..63)) MAX-ACCESS read-create STATUS current DESCRIPTION "User name associated with port. This is only applicable if port has role of Supplicant or Both" ::= { wwp8021xSupplicantSecEntry 1 } -- 1.3.6.1.4.1.6141.2.401.1.2.3.1.2 wwp8021xSupplicantSecPassword OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..63)) MAX-ACCESS read-create STATUS current DESCRIPTION "Password associated with port. This is only applicable if port has role of Supplicant or Both" ::= { wwp8021xSupplicantSecEntry 2 } END -- -- WWP-8021X-MIB.my --