-- **************************************************************************** -- -- Compaq Storage Systems -- Management Information Base for SNMP Network Management -- -- -- Copyright 1996-2002 Compaq Computer Corporation. -- All Rights Reserved. -- -- The information in this document is subject to change without notice. -- -- COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL -- OR EDITORIAL ERRORS OR OMISSIONS CONATINED HEREIN; NOR FOR INCIDENTAL -- OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, -- OR USE OF THIS MATERIAL. -- -- Refer to the READMIB.RDM file for more information about the -- organization of the information in the Compaq Enterprise. -- -- The Compaq Enterprise number is 232. -- The ASN.1 prefix to, and including the Compaq Enterprise is: -- 1.3.6.1.4.1.232 -- -- **************************************************************************** CPQSTSYS-MIB DEFINITIONS ::= BEGIN IMPORTS compaq FROM CPQHOST-MIB enterprises FROM RFC1155-SMI Counter FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 sysName FROM RFC1213-MIB cpqHoTrapFlags FROM CPQHOST-MIB; -- compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqSsStorageSys OBJECT IDENTIFIER ::= { compaq 8 } cpqSsMibRev OBJECT IDENTIFIER ::= { cpqSsStorageSys 1 } cpqSsDrvBox OBJECT IDENTIFIER ::= { cpqSsStorageSys 2 } cpqSsTrap OBJECT IDENTIFIER ::= { cpqSsStorageSys 3 } cpqSsRaidSystem OBJECT IDENTIFIER ::= { cpqSsStorageSys 4 } cpqSsBoxExtended OBJECT IDENTIFIER ::= { cpqSsDrvBox 2 } -- **************************************************************************** -- Storage System MIB Revision -- =========================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsMibRev Group (1.3.6.1.4.1.232.8.1) -- -- -- An agent conforming to this document will return a cpqSsMibRevMajor -- of one (1) and a cpqSsMibRevMinor of fifteen (15). -- -- Implementation of the MibRev group is mandatory. -- -- **************************************************************************** cpqSsMibRevMajor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level." ::= { cpqSsMibRev 1 } cpqSsMibRevMinor OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occurred." ::= { cpqSsMibRev 2 } cpqSsMibCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall condition (status) of the system represented by this MIB." ::= { cpqSsMibRev 3 } -- **************************************************************************** -- Storage System Drive Box Group -- ============================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsDrvBoxTable (1.3.6.1.4.1.232.8.2.1) -- -- Implementation of the Drive Box group is mandatory. -- -- **************************************************************************** cpqSsDrvBoxTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsDrvBoxEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Drive Box Table." ::= { cpqSsDrvBox 1 } cpqSsDrvBoxEntry OBJECT-TYPE SYNTAX CpqSsDrvBoxEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Drive Box Entry." INDEX { cpqSsBoxCntlrIndex, cpqSsBoxBusIndex } ::= { cpqSsDrvBoxTable 1 } CpqSsDrvBoxEntry ::= SEQUENCE { cpqSsBoxCntlrIndex INTEGER, cpqSsBoxBusIndex INTEGER, cpqSsBoxType INTEGER, cpqSsBoxModel DisplayString, cpqSsBoxFWRev DisplayString, cpqSsBoxVendor DisplayString, cpqSsBoxFanStatus INTEGER, cpqSsBoxCondition INTEGER, cpqSsBoxTempStatus INTEGER, cpqSsBoxSidePanelStatus INTEGER, cpqSsBoxFltTolPwrSupplyStatus INTEGER, cpqSsBoxBackPlaneVersion INTEGER, cpqSsBoxTotalBays INTEGER, cpqSsBoxPlacement INTEGER, cpqSsBoxDuplexOption INTEGER, cpqSsBoxBoardRevision INTEGER, cpqSsBoxSerialNumber DisplayString } cpqSsBoxCntlrIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Controller Index. The controller index indicates to which adapter card instance this table entry belongs. The controller index is the physical slot in the computer system where the adapter card is located." ::= { cpqSsDrvBoxEntry 1 } cpqSsBoxBusIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Bus Index. The bus index indicates to which bus instance on an adapter card this table entry belongs. The instances start at one and increment for each bus on a card." ::= { cpqSsDrvBoxEntry 2 } cpqSsBoxType OBJECT-TYPE SYNTAX INTEGER { other(1), proLiant(2), proLiant2(3), proLiant2Internal(4), proLiant2DuplexTop(5), proLiant2DuplexBottom(6), proLiant2InternalDuplexTop(7), proLiant2InternalDuplexBottom(8) } ACCESS read-only STATUS deprecated DESCRIPTION "Compaq Drive Box Type. This is the type of drive box. The following types are defined: other(1) The agent does not recognize this drive storage system. proLiant(2) This is a Compaq ProLiant Storage System. proLiant2(3) This is a Compaq ProLiant-2 Storage System. proLiant2Internal(4) This is an internal ProLiant-2 Storage System that is found in some Compaq Servers. proLiant2DuplexTop(5) This is the top portion of a Compaq ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2DuplexBottom(6) This is the bottom portion of a Compaq ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2InternalDuplexTop(7) This is the top portion of a Compaq ProLiant Server into which the internal SCSI busses are duplexed. proLiant2InternalDuplexBottom(8) This is the bottom portion of a Compaq ProLiant Server into which the internal SCSI busses are duplexed." ::= { cpqSsDrvBoxEntry 3 } cpqSsBoxModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Model. This is a description of the drive box's model. This can be used for identification purposes." ::= { cpqSsDrvBoxEntry 4 } cpqSsBoxFWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Firmware Revision. This is the revision level of the drive box. This can be used for identification purposes." ::= { cpqSsDrvBoxEntry 5 } cpqSsBoxVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Vendor This is the drive box's vendor name. This can be used for identification purposes." ::= { cpqSsDrvBoxEntry 6 } cpqSsBoxFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), failed(3), noFan(4), degraded(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Fan Status. This is the current status of the fans in the drive box. This value will be one of the following: other(1) Fan monitoring is not supported by this system or it is not supported by the driver. ok(2) All fans are working normally. failed(3) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. noFan(4) This unit does not support fan monitoring. degraded(5) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced." ::= { cpqSsDrvBoxEntry 7 } cpqSsBoxCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq SCSI Drive Box Condition. This is the overall condition of the drive box. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. Additionally, if the side panel for the storage system is removed, the air flow changes could result in improper cooling of the drives and affect the temperature status. failed(4) The storage system has failed." ::= { cpqSsDrvBoxEntry 8 } cpqSsBoxTempStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4), noTemp(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The temperature of the drive system. This value will be one of the following: other(1) Temperature monitoring is not supported by this system or it is not supported by the driver. ok(2) The temperature is within normal operating range. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected. noTemp(5) This unit does not support temperature monitoring." ::= { cpqSsDrvBoxEntry 9 } cpqSsBoxSidePanelStatus OBJECT-TYPE SYNTAX INTEGER { other(1), sidePanelInPlace(2), sidePanelRemoved(3), noSidePanelStatus(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Side Panel Status. This value will be one of the following: other(1) The agent does not recognize the status. You may need to upgrade your software. sidePanelInPlace(2) The side panel is properly installed on the storage system. sidePanelRemoved(3) The side panel is not properly installed on the storage system. noSidePanelStatus(4) This unit does not support side panel status monitoring." ::= { cpqSsDrvBoxEntry 10 } cpqSsBoxFltTolPwrSupplyStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4), noFltTolPower(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the overall status of the fault tolerant power supply sub-system in a drive box. This value will be one of the following: other(1) The power supply status cannot be determined. ok(2) There are no detected power supply failures. degraded(3) One of the power supply units in a fault tolerant power supply has failed. failed(4) No failure conditions can currently be determined. noFltTolPower(5) This unit does not support fault tolerant power supply monitoring." ::= { cpqSsDrvBoxEntry 11 } cpqSsBoxBackPlaneVersion OBJECT-TYPE SYNTAX INTEGER { other(1), proLiant(2), proLiant2(3), proLiant3(4), proLiant4(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Back Plane Version. This is the version of the drive box back plane. The following types are defined: other(1) The agent does not recognize this drive storage system back plane. proLiant(2) This is a Compaq ProLiant Storage System. proLiant2(3) This is a Compaq ProLiant-2 Storage System. proLiant3(4) This is a Compaq ProLiant-3 Storage System. proLiant4(5) This is a Compaq ProLiant-4 Storage System." ::= { cpqSsDrvBoxEntry 12 } cpqSsBoxTotalBays OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Total Bays. This is the total number of bays in this storage system." ::= { cpqSsDrvBoxEntry 13 } cpqSsBoxPlacement OBJECT-TYPE SYNTAX INTEGER { other(1), internal(2), external(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box." ::= { cpqSsDrvBoxEntry 14 } cpqSsBoxDuplexOption OBJECT-TYPE SYNTAX INTEGER { other(1), notDuplexed(2), duplexTop(3), duplexBottom(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Duplex Option. The following values are defined: other(1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system." ::= { cpqSsDrvBoxEntry 15 } cpqSsBoxBoardRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Drive Box Board Revision. This is the board revision of this storage system backplane." ::= { cpqSsDrvBoxEntry 16 } cpqSsBoxSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "COMPAQ Drive Box Serial Number. This is the drive box's serial number which is normally display on the front panel. This can be used for identification purposes." ::= { cpqSsDrvBoxEntry 17 } -- **************************************************************************** -- Storage System Chassis Group -- ============================ -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsChassisTable (1.3.6.1.4.1.232.8.2.2.1) -- -- **************************************************************************** cpqSsChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsChassisEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Table." ::= { cpqSsBoxExtended 1 } cpqSsChassisEntry OBJECT-TYPE SYNTAX CpqSsChassisEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Entry." INDEX { cpqSsChassisIndex } ::= { cpqSsChassisTable 1 } CpqSsChassisEntry ::= SEQUENCE { cpqSsChassisIndex INTEGER, cpqSsChassisConnectionType INTEGER, cpqSsChassisSerialNumber DisplayString, cpqSsChassisName DisplayString, cpqSsChassisSystemBoardSerNum DisplayString, cpqSsChassisSystemBoardRev DisplayString, cpqSsChassisPowerBoardSerNum DisplayString, cpqSsChassisPowerBoardRev DisplayString, cpqSsChassisScsiBoardSerNum DisplayString, cpqSsChassisScsiBoardRev DisplayString, cpqSsChassisOverallCondition INTEGER, cpqSsChassisPowerSupplyCondition INTEGER, cpqSsChassisFanCondition INTEGER, cpqSsChassisTemperatureCondition INTEGER, cpqSsChassisFcaCntlrCondition INTEGER, cpqSsChassisFcaLogicalDriveCondition INTEGER, cpqSsChassisFcaPhysDrvCondition INTEGER, cpqSsChassisTime INTEGER, cpqSsChassisModel INTEGER, cpqSsChassisBackplaneCondition INTEGER, cpqSsChassisFcaTapeDrvCondition INTEGER, cpqSsChassisRsoStatus INTEGER, cpqSsChassisRsoCondition INTEGER } cpqSsChassisIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Index. The chassis index uniquely identifies a storage system chassis." ::= { cpqSsChassisEntry 1 } cpqSsChassisConnectionType OBJECT-TYPE SYNTAX INTEGER { other(1), fibreAttached(2), scsiAttached(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this chassis. fibreAttached(2) This chassis is attached to the server via Fibre Channel. scsiAttached(3) This chassis is attached to the server via SCSI." ::= { cpqSsChassisEntry 2 } cpqSsChassisSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Serial Number. This is the storage system chassis's serial number which is normally displayed on the front panel. This can be used for identification purposes." ::= { cpqSsChassisEntry 3 } cpqSsChassisName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Name. This is a user defined name for this storage system chassis." ::= { cpqSsChassisEntry 4 } cpqSsChassisSystemBoardSerNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis System Controller Board Serial Number. This is the system controller board's serial number. This can be used for identification purposes." ::= { cpqSsChassisEntry 5 } cpqSsChassisSystemBoardRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis System Controller Board Revision. This is the system controller board revision." ::= { cpqSsChassisEntry 6 } cpqSsChassisPowerBoardSerNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Power Backplane Board Serial Number. This is the power backplane board's serial number. This can be used for identification purposes." ::= { cpqSsChassisEntry 7 } cpqSsChassisPowerBoardRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Power Backplane Board Revision. This is the power backplane board revision." ::= { cpqSsChassisEntry 8 } cpqSsChassisScsiBoardSerNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis SCSI Drive Backplane Board Serial Number. This is the SCSI drive backplane board's serial number. This can be used for identification purposes." ::= { cpqSsChassisEntry 9 } cpqSsChassisScsiBoardRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis SCSI Drive Backplane Board Revision. This is the SCSI drive backplane board revision." ::= { cpqSsChassisEntry 10 } cpqSsChassisOverallCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Overall Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system chassis is degraded. failed(4) The storage system chassis is failed." ::= { cpqSsChassisEntry 11 } cpqSsChassisPowerSupplyCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Condition. This is the aggregate condition of all power supplies in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All power supplies are operating normally. degraded(3) At least one power supply is degraded or failed. failed(4) All power supplies are failed." ::= { cpqSsChassisEntry 12 } cpqSsChassisFanCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Condition. This is the aggregate condition of all fan modules in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All fan modules are operating normally. degraded(3) At least one fan module is degraded. failed(4) At least one fan module is failed." ::= { cpqSsChassisEntry 13 } cpqSsChassisTemperatureCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Condition. This is the aggregate condition of all the temperatur sensors in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All temperature sensors are reading within normal limits. degraded(3) At least one temperature sensor is reading degraded. failed(4) At least one temperature sensor is reading failed." ::= { cpqSsChassisEntry 14 } cpqSsChassisFcaCntlrCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Channel Array Controller Condition. This is the aggregate condition of all Fibre Channel Array controllers in the storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers are operating normally. degraded(3) At least one Fibre Channel Array Controller is degraded or failed. failed(4) All Fibre Channel Array Controllers are failed." ::= { cpqSsChassisEntry 15 } cpqSsChassisFcaLogicalDriveCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Channel Array Logical Drive Condition. This is the aggregate condition of all Fibre Channel Array Logical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Logical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Logical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Logical Drive is failed." ::= { cpqSsChassisEntry 16 } cpqSsChassisFcaPhysDrvCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Channel Array Physical Drive Condition. This is the aggregate condition of all Fibre Channel Array Physical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Physical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Physical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Physical Drive is failed." ::= { cpqSsChassisEntry 17 } cpqSsChassisTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Time. This is the storage system chassis's time in tenths of seconds. If the chassis time is not supported, the agent will return 0." ::= { cpqSsChassisEntry 18 } cpqSsChassisModel OBJECT-TYPE SYNTAX INTEGER { other(1), ra4x00(2), msa1000(3), smartArrayClusterStorage(4), enterpriseModularArray(5), enterpriseVirtualArray(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Model. The following values are defined: other(1) The agent is unable to determine the model of this chassis. ra4x00(2) Compaq StorageWorks RAID Array 4000/4100. msa1000(3) Compaq StorageWorks Modular SAN Array 1000. smartArrayClusterStorage(4) Compaq Smart Array Cluster Storage. enterpriseModularArray(5) Compaq StorageWorks Enterprise/Modular RAID Array. enterpriseVirtualArray(6) Compaq StorageWorks Enterprise Virtual Array." ::= { cpqSsChassisEntry 19 } cpqSsChassisBackplaneCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Condition. This is the aggregate condition of all the backplanes for the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All backplanes are operating normally. degraded(3) At least one storage system is degraded. failed(4) At least one storage system is failed." ::= { cpqSsChassisEntry 20 } cpqSsChassisFcaTapeDrvCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Array Tape Drive Condition. This is the aggregate condition of all tape drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All tape drives are operating normally. degraded(3) At least one tape drive is degraded. failed(4) At least one tape drive is failed." ::= { cpqSsChassisEntry 21 } cpqSsChassisRsoStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notSupported(2), notConfigured(3), disabled(4), daemonDownDisabled(5), ok(6), daemonDownActive(7), noSecondary(8), daemonDownNoSecondary(9), linkDown(10), daemonDownLinkDown(11), secondaryRunningAuto(12), secondaryRunningUser(13) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Recovery Server Option Status. The following values are defined: other(1) The recovery server option status cannot be determined for this storage system. notSupported(2) The recovery server option is not supported for this storage system. notConfigured(3) The recovery server option is supported, but is not configured on this storage system. disabled(4) The recovery server option is configured as primary, but has been disabled by software. daemonDownDisabled(5) The recovery server option operating system daemon is no longer running. The last status of RSO was disabled(4). ok(6) The recovery server option is configured as primary and everything is working correctly. daemonDownActive(7) The recovery server option operating system daemon is no longer running. The last status of RSO was ok(6). noSecondary(8) The recovery server option is configured as primary, but communication with the standby server has not been established. daemonDownNoSecondary(9) The recovery server option operating system daemon is no longer running. The last status of RSO was noSecondary(8). linkDown(10) The recovery server option is configured as primary, but communication with the standby server has failed. daemonDownLinkDown(11) The recovery server option operating system daemon is no longer running. The last status of RSO was linkDown(10). secondaryRunningAuto(12) The recovery server option is configured and the standby server is running. The secondary server assumed control after communication with the primary server failed. secondaryRunningUser(13) The recovery server option is configured and the standby server is running. A user forced the secondary server to assume control." ::= { cpqSsChassisEntry 22 } cpqSsChassisRsoCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Chassis Recovery Server Option Condition. This is the condition of the recovery server option. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The recovery server option is operating normally. No user action is required. degraded(3) The recovery server option is degraded. failed(4) The recovery server option is failed." ::= { cpqSsChassisEntry 23 } -- **************************************************************************** -- Storage System I/O Slot Table -- ============================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsIoSlotTable (1.3.6.1.4.1.232.8.2.2.2) -- -- **************************************************************************** cpqSsIoSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsIoSlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System I/O Slot Table." ::= { cpqSsBoxExtended 2 } cpqSsIoSlotEntry OBJECT-TYPE SYNTAX CpqSsIoSlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System I/O Slot Entry." INDEX { cpqSsIoSlotChassisIndex, cpqSsIoSlotIndex } ::= { cpqSsIoSlotTable 1 } CpqSsIoSlotEntry ::= SEQUENCE { cpqSsIoSlotChassisIndex INTEGER, cpqSsIoSlotIndex INTEGER, cpqSsIoSlotControllerType INTEGER } cpqSsIoSlotChassisIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System I/O Slot Chassis Index. The chassis index uniquely identifies a storage system chassis." ::= { cpqSsIoSlotEntry 1 } cpqSsIoSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System I/O Slot Index. This index uniquely identifies a storage system I/O Slot." ::= { cpqSsIoSlotEntry 2 } cpqSsIoSlotControllerType OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), unknownBoard(3), fibreArray(4), scsiArray(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System I/O Slot Controller Type. The following values are defined: other(1) The agent is unable to determine if anything is installed in this storage system I/O slot. notInstalled(2) Nothing is installed in this storage system I/O slot. unknownBoardInstalled(3) An unknown controller is installed in this storage system I/O slot. fibreArray(4) A Compaq Fibre Channel Array controller is installed in this storage system I/O slot. scsiArray(5) A Compaq SCSI Array controller is installed in this storage system I/O slot." ::= { cpqSsIoSlotEntry 3 } -- **************************************************************************** -- Storage System Power Supply Table -- ================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsPowerSupplyTable (1.3.6.1.4.1.232.8.2.2.3) -- -- **************************************************************************** cpqSsPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsPowerSupplyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Table." ::= { cpqSsBoxExtended 3 } cpqSsPowerSupplyEntry OBJECT-TYPE SYNTAX CpqSsPowerSupplyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Entry." INDEX { cpqSsPowerSupplyChassisIndex, cpqSsPowerSupplyIndex } ::= { cpqSsPowerSupplyTable 1 } CpqSsPowerSupplyEntry ::= SEQUENCE { cpqSsPowerSupplyChassisIndex INTEGER, cpqSsPowerSupplyIndex INTEGER, cpqSsPowerSupplyBay INTEGER, cpqSsPowerSupplyStatus INTEGER, cpqSsPowerSupplyUpsStatus INTEGER, cpqSsPowerSupplyCondition INTEGER, cpqSsPowerSupplySerialNumber DisplayString, cpqSsPowerSupplyBoardRevision DisplayString, cpqSsPowerSupplyFirmwareRevision DisplayString } cpqSsPowerSupplyChassisIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Chassis Index. The chassis index uniquely identifies a storage system chassis." ::= { cpqSsPowerSupplyEntry 1 } cpqSsPowerSupplyIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Bay. This index uniquely identifies a power supply bay." ::= { cpqSsPowerSupplyEntry 2 } cpqSsPowerSupplyBay OBJECT-TYPE SYNTAX INTEGER { other(1), powerBay1(2), powerBay2(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Bay. The following values are defined: other(1) The agent does not recognize the bay. You may need to upgrade your software. powerBay1(2) The power supply is installed in the first power supply bay. powerBay2(3) The power supply is installed in the second power supply bay." ::= { cpqSsPowerSupplyEntry 3 } cpqSsPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), ok(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply." ::= { cpqSsPowerSupplyEntry 4 } cpqSsPowerSupplyUpsStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noUps(2), ok(3), powerFailed(4), batteryLow(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Uninterruptible Power Supply (UPS) Status. The following values are defined: other(1) The agent is unable to determine if this power supply is attached to an Uninterruptible Power Supply (UPS). noUps(2) No UPS is attached to the power supply. ok(3) A UPS is attached to the power supply and is operating normally. powerFailed(4) A UPS is attached to the power supply and the AC power has failed. batteryLow(5) A UPS is attached to the power supply, the AC power has failed and the UPS battery is low." ::= { cpqSsPowerSupplyEntry 5 } cpqSsPowerSupplyCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The power supply is operating normally. No user action is required. degraded(3) The power supply is degraded. You need to check the power supply or its attached UPS for problems. failed(4) The power supply has failed." ::= { cpqSsPowerSupplyEntry 6 } cpqSsPowerSupplySerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Serial Number. This is the power supply's serial number. This can be used for identification purposes. If the serial number is not supported, the agent will return a NULL string." ::= { cpqSsPowerSupplyEntry 7 } cpqSsPowerSupplyBoardRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Board Revision. This is the power supply board revision. If the board revision is not supported, the agent will return a NULL string." ::= { cpqSsPowerSupplyEntry 8 } cpqSsPowerSupplyFirmwareRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Power Supply Firmware Revision. This is the power supply firmware revision. If the firmware revision is not supported, the agent will return a NULL string." ::= { cpqSsPowerSupplyEntry 9 } -- **************************************************************************** -- Storage System Fan Module Table -- =============================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsFanModuleTable (1.3.6.1.4.1.232.8.2.2.4) -- -- **************************************************************************** cpqSsFanModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsFanModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Table." ::= { cpqSsBoxExtended 4 } cpqSsFanModuleEntry OBJECT-TYPE SYNTAX CpqSsFanModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Entry." INDEX { cpqSsFanModuleChassisIndex, cpqSsFanModuleIndex } ::= { cpqSsFanModuleTable 1 } CpqSsFanModuleEntry ::= SEQUENCE { cpqSsFanModuleChassisIndex INTEGER, cpqSsFanModuleIndex INTEGER, cpqSsFanModuleStatus INTEGER, cpqSsFanModuleCondition INTEGER, cpqSsFanModuleLocation INTEGER, cpqSsFanModuleSerialNumber DisplayString, cpqSsFanModuleBoardRevision DisplayString } cpqSsFanModuleChassisIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Chassis Index. The chassis index uniquely identifies a storage system chassis." ::= { cpqSsFanModuleEntry 1 } cpqSsFanModuleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Index. This index uniquely identifies a storage system fan module." ::= { cpqSsFanModuleEntry 2 } cpqSsFanModuleStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), ok(3), degraded(4), failed(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Status. The following values are defined: other(1) The agent is unable to determine if this storage system fan module is installed. notInstalled(3) The fan module is not installed. ok(2) The fan module is installed and operating normally. degraded(4) The fan module degraded. failed(5) The fan module is failed. Replace the fan module." ::= { cpqSsFanModuleEntry 3 } cpqSsFanModuleCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module." ::= { cpqSsFanModuleEntry 4 } cpqSsFanModuleLocation OBJECT-TYPE SYNTAX INTEGER { other(1), fanBay(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system fan module. fanBay(2) This fan module is installed in the fan bay." ::= { cpqSsFanModuleEntry 5 } cpqSsFanModuleSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Serial Number. This is the fan module's serial number. This can be used for identification purposes." ::= { cpqSsFanModuleEntry 6 } cpqSsFanModuleBoardRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Board Revision. This is the fan module board revision." ::= { cpqSsFanModuleEntry 7 } -- **************************************************************************** -- Storage System Temperature Sensor Table -- ======================================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsTempSensorTable (1.3.6.1.4.1.232.8.2.2.5) -- -- **************************************************************************** cpqSsTempSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsTempSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Table." ::= { cpqSsBoxExtended 5 } cpqSsTempSensorEntry OBJECT-TYPE SYNTAX CpqSsTempSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Entry." INDEX { cpqSsTempSensorChassisIndex, cpqSsTempSensorIndex } ::= { cpqSsTempSensorTable 1 } CpqSsTempSensorEntry ::= SEQUENCE { cpqSsTempSensorChassisIndex INTEGER, cpqSsTempSensorIndex INTEGER, cpqSsTempSensorStatus INTEGER, cpqSsTempSensorCondition INTEGER, cpqSsTempSensorLocation INTEGER, cpqSsTempSensorCurrentValue INTEGER, cpqSsTempSensorLimitValue INTEGER, cpqSsTempSensorHysteresisValue INTEGER } cpqSsTempSensorChassisIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Chassis Index. The chassis index uniquely identifies a storage system chassis." ::= { cpqSsTempSensorEntry 1 } cpqSsTempSensorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Index. This index uniquely identifies a temperature sensor." ::= { cpqSsTempSensorEntry 2 } cpqSsTempSensorStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Status. The following values are defined: other(1) The agent is unable to determine if the storage system temperature sensor status. ok(2) The temperature is OK. degraded(3) The temperature is degraded. failed(4) The temperature is failed." ::= { cpqSsTempSensorEntry 3 } cpqSsTempSensorCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Condition. This is the condition of the storage system temperature sensor. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The temperature is within normal operating range. No user action is required. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected." ::= { cpqSsTempSensorEntry 4 } cpqSsTempSensorLocation OBJECT-TYPE SYNTAX INTEGER { other(1), fanBay(2), backplane(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system temperature sensor. fanBay(2) This temperature sensor is located on the fan module in the fan bay. backplane(3) This temperature is located on the SCSI drive backplane." ::= { cpqSsTempSensorEntry 5 } cpqSsTempSensorCurrentValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Current Value. The current value of the temperature sensor in degrees Celsius." ::= { cpqSsTempSensorEntry 6 } cpqSsTempSensorLimitValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Limit Value. The limit value of the temperature sensor in degrees Celsius." ::= { cpqSsTempSensorEntry 7 } cpqSsTempSensorHysteresisValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Temperature Sensor Hysteresis Value. The hysteresis value of the temperature sensor in degrees Celsius." ::= { cpqSsTempSensorEntry 8 } -- **************************************************************************** -- Storage System SCSI Backplane Table -- =================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsBackplaneTable (1.3.6.1.4.1.232.8.2.2.6) -- -- **************************************************************************** cpqSsBackplaneTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsBackplaneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Backplane Table." ::= { cpqSsBoxExtended 6 } cpqSsBackplaneEntry OBJECT-TYPE SYNTAX CpqSsBackplaneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Backplane Entry." INDEX { cpqSsBackplaneChassisIndex, cpqSsBackplaneIndex } ::= { cpqSsBackplaneTable 1 } CpqSsBackplaneEntry ::= SEQUENCE { cpqSsBackplaneChassisIndex INTEGER, cpqSsBackplaneIndex INTEGER, cpqSsBackplaneFWRev DisplayString, cpqSsBackplaneDriveBays INTEGER, cpqSsBackplaneDuplexOption INTEGER, cpqSsBackplaneCondition INTEGER, cpqSsBackplaneVersion INTEGER, cpqSsBackplaneVendor DisplayString, cpqSsBackplaneModel DisplayString, cpqSsBackplaneFanStatus INTEGER, cpqSsBackplaneTempStatus INTEGER, cpqSsBackplaneFtpsStatus INTEGER, cpqSsBackplaneSerialNumber DisplayString, cpqSsBackplanePlacement INTEGER, cpqSsBackplaneBoardRevision INTEGER } cpqSsBackplaneChassisIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Chassis Index. The chassis index uniquely identifies a storage system chassis." ::= { cpqSsBackplaneEntry 1 } cpqSsBackplaneIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Index. This index uniquely identifies a storage system backplane." ::= { cpqSsBackplaneEntry 2 } cpqSsBackplaneFWRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Firmware Revision. This is the revision level of storage system backplane." ::= { cpqSsBackplaneEntry 3 } cpqSsBackplaneDriveBays OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Drive Bays. This is the number of bays on this storage system backplane." ::= { cpqSsBackplaneEntry 4 } cpqSsBackplaneDuplexOption OBJECT-TYPE SYNTAX INTEGER { other(1), notDuplexed(2), duplexTop(3), duplexBottom(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Duplex Option. The following values are defined: other (1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system." ::= { cpqSsBackplaneEntry 5 } cpqSsBackplaneCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Condition. This is the overall condition of the backplane. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. failed(4) The storage system has failed." ::= { cpqSsBackplaneEntry 6 } cpqSsBackplaneVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Version. This is the version of the drive box back plane." ::= { cpqSsBackplaneEntry 7 } cpqSsBackplaneVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Vendor This is the storage box's vendor name. This can be used for identification purposes." ::= { cpqSsBackplaneEntry 8 } cpqSsBackplaneModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..17)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Model. This is a description of the storage system's model. This can be used for identification purposes." ::= { cpqSsBackplaneEntry 9 } cpqSsBackplaneFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), ok(3), degraded(4), failed(5), notSupported(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent is unable to determine if this storage system has fan monitoring. notInstalled(2) This unit does not support fan monitoring. ok(3) All fans are working normally. degraded(4) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. failed(5) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. notSupported(6) The storage system does not support reporting fan status through this backplane. The fan status is reported through the first backplane on this storage system." ::= { cpqSsBackplaneEntry 10 } cpqSsBackplaneTempStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noTemp(2), ok(3), degraded(4), failed(5), notSupported(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Fan Status. This value will be one of the following: other(1) The agent is unable to determine if this storage system has temperature monitoring. noTemp(2) This unit does not support temperature monitoring. ok(3) The temperature is within normal operating range. degraded(4) The temperature is outside of normal operating range. failed(5) The temperature could permanently damage the system. notSupported(6) The storage system does not support reporting temperature status through this backplane. The temperature status is reported through the first backplane on this storage system." ::= { cpqSsBackplaneEntry 11 } cpqSsBackplaneFtpsStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noFltTolPower(2), ok(3), degraded(4), failed(5), notSupported(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant power supply in a drive box. This value will be one of the following: other(1) The agent is unable to determine if this storage system has redundant power supplies. noFltTolPower(2) This unit does not have a redundant supply. ok(3) There are no detected power supply failures. degraded(4) One of the power supply units has failed. failed(5) All of the power supplies have failed. A status of failed can not currently be determined. notSupported(6) The storage system does not support reporting fault tolerant power supply status through this backplane. The fault tolerant power supply status is reported through the first backplane on this storage system." ::= { cpqSsBackplaneEntry 12 } cpqSsBackplaneSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Serial Number. This is the storage system backplane serial number which is normally displayed on the front bezel. This can be used for identification purposes." ::= { cpqSsBackplaneEntry 13 } cpqSsBackplanePlacement OBJECT-TYPE SYNTAX INTEGER { other(1), internal(2), external(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box." ::= { cpqSsBackplaneEntry 14 } cpqSsBackplaneBoardRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage system Backplane Board Revision. This is the board revision of this storage system backplane." ::= { cpqSsBackplaneEntry 15 } -- **************************************************************************** -- Storage System Fibre Attachment Table -- ===================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsFibreAttachmentTable (1.3.6.1.4.1.232.8.2.2.7) -- -- The Storage System Fibre Attachment Group contains associations between -- Fibre channel host controllers and the Fibre devices that are attached to -- them. Since there can be multiple paths to some Fibre devices, there may -- be multiple entries for a given device. -- -- **************************************************************************** cpqSsFibreAttachmentTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsFibreAttachmentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Table." ::= { cpqSsBoxExtended 7 } cpqSsFibreAttachmentEntry OBJECT-TYPE SYNTAX CpqSsFibreAttachmentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Entry." INDEX { cpqSsFibreAttachmentIndex } ::= { cpqSsFibreAttachmentTable 1 } CpqSsFibreAttachmentEntry ::= SEQUENCE { cpqSsFibreAttachmentIndex INTEGER, cpqSsFibreAttachmentHostControllerIndex INTEGER, cpqSsFibreAttachmentHostControllerPort INTEGER, cpqSsFibreAttachmentDeviceType INTEGER, cpqSsFibreAttachmentDeviceIndex INTEGER, cpqSsFibreAttachmentDevicePort INTEGER } cpqSsFibreAttachmentIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Index. The index uniquely identifies a Fibre Attachment association entry." ::= { cpqSsFibreAttachmentEntry 1 } cpqSsFibreAttachmentHostControllerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Host Controller Index. The host controller index indicates which host controller is associated with this entry. This is equal to cpqFcaHostCntlrIndex, from the Fibre Channel Host Controller Table." ::= { cpqSsFibreAttachmentEntry 2 } cpqSsFibreAttachmentHostControllerPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Host Controller Port. This is the Fibre port number of the host controller. For each host controller, the port number starts at 1 and increments for each port. This is currently set to 1." ::= { cpqSsFibreAttachmentEntry 3 } cpqSsFibreAttachmentDeviceType OBJECT-TYPE SYNTAX INTEGER { other(1), storageBox(2), tapeController(3), fibreChannelSwitch(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Device Type. This is the type of device associated with this entry. The following values are defined: other(1) The agent is unable to determine if the type of this device. storageBox(2) The device is a Fibre attached storage system. tapeController(3) The device is a Fibre attached tape controller. fibreChannelSwitch(4) The device is a Fibre channel switch." ::= { cpqSsFibreAttachmentEntry 4 } cpqSsFibreAttachmentDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Device Index. The is the index for the Fibre attached device. For a Fibre attached storage system, this is equal to cpqSsChassisIndex from the Storage System Chassis Table. For a Fibre attached tape controller, this is equal to cpqFcTapeCntlrIndex from the Fibre Channel Tape Controller Table. For a Fibre channel switch, this is equal to cpqFcSwitchIndex from the Fibre Channel Switch Table." ::= { cpqSsFibreAttachmentEntry 5 } cpqSsFibreAttachmentDevicePort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Fibre Attachment Device Port. This is the Fibre port on a device. For a Fibre attached storage system, this is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table. For a Fibre attached tape controller, this is currently set to 1. For a Fibre channel switch, this is currently set to 1." ::= { cpqSsFibreAttachmentEntry 6 } -- **************************************************************************** -- Storage System Scsi Attachment Table -- ==================================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2) -- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2) -- cpqSsScsiAttachmentTable (1.3.6.1.4.1.232.8.2.2.8) -- -- The Storage System Scsi Attachment Group contains associations between -- internal array controllers and the external arrays that are attached to -- them. Since there can be multiple paths to some external arrays, there -- may be multiple entries for a given device. -- -- **************************************************************************** cpqSsScsiAttachmentTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsScsiAttachmentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Table." ::= { cpqSsBoxExtended 8 } cpqSsScsiAttachmentEntry OBJECT-TYPE SYNTAX CpqSsScsiAttachmentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Entry." INDEX { cpqSsScsiAttachmentIndex } ::= { cpqSsScsiAttachmentTable 1 } CpqSsScsiAttachmentEntry ::= SEQUENCE { cpqSsScsiAttachmentIndex INTEGER, cpqSsScsiAttachmentControllerIndex INTEGER, cpqSsScsiAttachmentControllerPort INTEGER, cpqSsScsiAttachmentControllerTarget INTEGER, cpqSsScsiAttachmentControllerLun INTEGER, cpqSsScsiAttachmentChassisIndex INTEGER, cpqSsScsiAttachmentChassisIoSlot INTEGER } cpqSsScsiAttachmentIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Index. The index uniquely identifies a SCSI Attachment association entry." ::= { cpqSsScsiAttachmentEntry 1 } cpqSsScsiAttachmentControllerIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Controller Index. The controller index indicates which internal array controller is associated with this entry. This is equal to cpqDaCntlrIndex, from the Array Controller Table." ::= { cpqSsScsiAttachmentEntry 2 } cpqSsScsiAttachmentControllerPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Controller Port. The controller port indicates which SCSI port of an internal controller is associated with this entry." ::= { cpqSsScsiAttachmentEntry 3 } cpqSsScsiAttachmentControllerTarget OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Controller Target. The controller target indicates which SCSI target is associated with this entry." ::= { cpqSsScsiAttachmentEntry 4 } cpqSsScsiAttachmentControllerLun OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Controller Lun. The controller Lun indicates which SCSI Lun is associated with this entry." ::= { cpqSsScsiAttachmentEntry 5 } cpqSsScsiAttachmentChassisIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Chassis Index. The is the index for the SCSI attached storage system. This is equal to cpqSsChassisIndex from the Storage System Chassis Table." ::= { cpqSsScsiAttachmentEntry 6 } cpqSsScsiAttachmentChassisIoSlot OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System SCSI Attachment Chassis I/O Slot. This is the I/O slot in the SCSI attached storage system. This is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table." ::= { cpqSsScsiAttachmentEntry 7 } -- **************************************************************************** -- Storage System Trap Group -- ========================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsTrap Group (1.3.6.1.4.1.232.8.3) (deprecated) -- -- -- The trap group maintains information about the number of traps issued -- from the storageSys enterprise. The trap group also maintains a table of -- the last several traps issued. This table is intended to give a -- management application some recent status information immediately upon -- accessing the agent. -- -- Implementation of the Trap group is optional for agents. -- The trap group has been deprecated for Insight v2.00 Agents. -- -- **************************************************************************** cpqSsTrapPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "The total number of trap packets issued by the enterprise since the instrument agent was loaded." ::= { cpqSsTrap 1 } cpqSsTrapLogMaxSize OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS deprecated DESCRIPTION "The maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be removed." ::= { cpqSsTrap 2 } -- **************************************************************************** -- Storage System Trap Log Table -- ============================= -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsTrap Group (1.3.6.1.4.1.232.8.3) (deprecated) -- cpqSsTrapLogTable (1.3.6.1.4.1.232.8.3.3) (deprecated) -- -- **************************************************************************** cpqSsTrapLogTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsTrapLogEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "An ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent trap at index 1 and the oldest trap entry at index trapLogMaxSize. If the maximum number size has been reached and a new trap occurs the oldest trap will be removed when the new trap is added so the trapMaxLogSize is not exceeded." ::= { cpqSsTrap 3 } cpqSsTrapLogEntry OBJECT-TYPE SYNTAX CpqSsTrapLogEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "A description of a trap event." INDEX { cpqSsTrapLogIndex } ::= { cpqSsTrapLogTable 1 } CpqSsTrapLogEntry ::= SEQUENCE { cpqSsTrapLogIndex INTEGER, cpqSsTrapType INTEGER, cpqSsTrapTime OCTET STRING } cpqSsTrapLogIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS deprecated DESCRIPTION "The value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an index of trapLogMaxSize. Because of the queue-like nature of the trapLog this particular trap event's index will change as new traps are issued." ::= { cpqSsTrapLogEntry 1 } cpqSsTrapType OBJECT-TYPE SYNTAX INTEGER { cpqSsFanStatusChange(1), cpqSs2FanStatusChange(8001), cpqSsTempFailed(8002), cpqSsTempDegraded(8003), cpqSsTempOk(8004), cpqSsSidePanelInPlace(8005), cpqSsSidePanelRemoved(8006) } ACCESS read-only STATUS deprecated DESCRIPTION "The type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the agent may issue." ::= { cpqSsTrapLogEntry 2 } cpqSsTrapTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) ACCESS read-only STATUS deprecated DESCRIPTION "The time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Each octet gives the value in BCD." ::= { cpqSsTrapLogEntry 3 } -- **************************************************************************** -- RAID Storage System Group -- ============================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- cpqSsStorageSys Group (1.3.6.1.4.1.232.8) -- cpqSsRaidSystem Group (1.3.6.1.4.1.232.8.4) -- cpqSsRaidSystemTable (1.3.6.1.4.1.232.8.4.1) -- -- Implementation of the RAID Storage System group is mandatory. -- -- **************************************************************************** cpqSsRaidSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqSsRaidSystemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq RAID Storage System Table." ::= { cpqSsRaidSystem 1 } cpqSsRaidSystemEntry OBJECT-TYPE SYNTAX CpqSsRaidSystemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq RAID Storage System Entry." INDEX { cpqSsRaidSystemIndex } ::= { cpqSsRaidSystemTable 1 } CpqSsRaidSystemEntry ::= SEQUENCE { cpqSsRaidSystemIndex INTEGER, cpqSsRaidSystemName DisplayString, cpqSsRaidSystemStatus INTEGER, cpqSsRaidSystemCondition INTEGER, cpqSsRaidSystemCntlr1SerialNumber DisplayString, cpqSsRaidSystemCntlr2SerialNumber DisplayString } cpqSsRaidSystemIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq RAID Storage System Index. The RAID Storage System index indicates to which storage system instance this table entry belongs." ::= { cpqSsRaidSystemEntry 1 } cpqSsRaidSystemName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Compaq RAID Storage System Name. This is a description of the RAID Storage System's name. This can be used for identification purposes." ::= { cpqSsRaidSystemEntry 2 } cpqSsRaidSystemStatus OBJECT-TYPE SYNTAX INTEGER { other(1), agentNotRunning(2), good(3), warning(4), communicationLoss(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq RAID Storage System Status. This is the current status of the RAID Storage System. This value will be one of the following: other(1) Indicates that the agent does not recognize the state of the RAID Storage System. You may need to upgrade the agent. agentNotRunning(2) Indicates that the Storage Work agent is not running. You need to restart the Storage Work agent. good(3) Indicates that the system is operating properly. warning(4) At least one component of the system failed. communicationLoss(5) The RAID Storage System has a cable or communication problem. Please check all cable connects to the host server." ::= { cpqSsRaidSystemEntry 3 } cpqSsRaidSystemCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq RAID Storage System Condition. This is the overall condition of the storage system. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. At least one component of the storage system failed. failed(4) The storage system has failed." ::= { cpqSsRaidSystemEntry 4 } cpqSsRaidSystemCntlr1SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "COMPAQ RAID Storage System Controller 1 Serial Number. This is the controller number 1's serial number which is normally display on the front panel. This can be used for identification purposes." ::= { cpqSsRaidSystemEntry 5 } cpqSsRaidSystemCntlr2SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "COMPAQ RAID Storage System Controller 2 Serial Number. This is the controller number 2's serial number which is normally display on the front panel. This can be used for identification purposes." ::= { cpqSsRaidSystemEntry 6 } -- **************************************************************************** -- Storage System Trap Definitions -- =============================== -- -- The compaq enterprise (1.3.6.1.4.1.232) -- -- The SNMP trap messages must not be bigger than 484 octets (bytes). -- -- Trap support in an SNMP agent implementation is optional. An SNMP -- agent implementation may support all, some, or none of the traps. -- If traps are supported, The user should be provided with the option of -- disabling traps. -- -- ************************************************************************** cpqSsFanStatusChange TRAP-TYPE ENTERPRISE cpqSsStorageSys VARIABLES { cpqSsBoxFanStatus } DESCRIPTION "Storage System fan status change. The agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status." --#TYPE "Fan Status Change" --#SUMMARY "Storage System fan status changed to %d." --#ARGUMENTS {0} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 1 cpqSs2FanStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqSsBoxFanStatus } DESCRIPTION "Storage System fan status change. The agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status." --#TYPE "Fan Status Change" --#SUMMARY "Storage System fan status changed to %d." --#ARGUMENTS {0} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8001 cpqSsTempFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqSsBoxTempStatus } DESCRIPTION "Storage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown." --#TYPE "Storage System Temperature Failure" --#SUMMARY "Storage System will be shutdown." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL ::= 8002 cpqSsTempDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqSsBoxTempStatus } DESCRIPTION "Storage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range." --#TYPE "Storage System Temp Degraded" --#SUMMARY "Temp is outside of normal range." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 8003 cpqSsTempOk TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqSsBoxTempStatus } DESCRIPTION "Storage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator." --#TYPE "Compaq Storage System" --#SUMMARY "Storage System temperature ok." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 8004 cpqSsSidePanelInPlace TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqSsBoxSidePanelStatus } DESCRIPTION "Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state." --#TYPE "Storage System side panel is in place." --#SUMMARY "Side panel is re-installed on unit." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 8005 cpqSsSidePanelRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqSsBoxSidePanelStatus } DESCRIPTION "Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel." --#TYPE "Storage System side panel is removed" --#SUMMARY "Side panel is removed from unit." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 8006 cpqSsPwrSupplyDegraded TRAP-TYPE ENTERPRISE compaq DESCRIPTION "A storage system power supply status has been set to degraded." --#TYPE "Power Supply Degraded" --#SUMMARY "A storage system power supply unit has become degraded" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 8007 cpqSs3FanStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxFanStatus } DESCRIPTION "Storage System fan status change. The agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans." --#TYPE "Fan Status Change" --#SUMMARY "Storage System fan status changed to %d." --#ARGUMENTS {2} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8008 cpqSs3TempFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxTempStatus } DESCRIPTION "Storage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated." --#TYPE "Storage System Temperature Failure" --#SUMMARY "Storage System will be shutdown." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL ::= 8009 cpqSs3TempDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxTempStatus } DESCRIPTION "Storage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated." --#TYPE "Storage System Temp Degraded" --#SUMMARY "Temp is outside of normal range." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 8010 cpqSs3TempOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxTempStatus } DESCRIPTION "Storage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator. User Action: None." --#TYPE "Compaq Storage System" --#SUMMARY "Storage System temperature ok." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 8011 cpqSs3SidePanelInPlace TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxSidePanelStatus } DESCRIPTION "Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state. User Action: None." --#TYPE "Storage System side panel is in place." --#SUMMARY "Side panel is re-installed on unit." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 8012 cpqSs3SidePanelRemoved TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxSidePanelStatus } DESCRIPTION "Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel. User Action: Replace the storage system side panel." --#TYPE "Storage System side panel is removed" --#SUMMARY "Side panel is removed from unit." --#ARGUMENTS {} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 8013 cpqSs3PwrSupplyDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } DESCRIPTION "A storage system power supply status has been set to degraded." --#TYPE "Power Supply Degraded" --#SUMMARY "A storage system power supply unit has become degraded" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 8014 cpqSs4PwrSupplyDegraded TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxFltTolPwrSupplyStatus } DESCRIPTION "A storage system power supply status has been set to degraded. User Action: Take action to restore power or replace any failed storage system power supply." --#TYPE "Power Supply Degraded" --#SUMMARY "A storage system power supply unit has become degraded" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED ::= 8015 cpqSsExFanStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsFanModuleLocation, cpqSsFanModuleStatus } DESCRIPTION "Storage system fan status change. The agent has detected a change in the Fan Module Status of a Compaq storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans." --#TYPE "Fan Status Change" --#SUMMARY "Storage system fan status changed to %d." --#ARGUMENTS {5} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8016 cpqSsExPowerSupplyStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsPowerSupplyBay, cpqSsPowerSupplyStatus } DESCRIPTION "Storage system power supply status change. The agent has detected a change in the power supply status of a Compaq storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply." --#TYPE "Power Supply Status Change" --#SUMMARY "Storage system power supply status changed to %d." --#ARGUMENTS {5} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8017 cpqSsExPowerSupplyUpsStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsPowerSupplyBay, cpqSsPowerSupplyUpsStatus } DESCRIPTION "Storage system power supply UPS status change. The agent has detected a change status of a UPS attached to a Compaq storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates the current status. User Action: If the UPS status is powerFailed(4) or batteryLow(5), take action to restore power to the UPS." --#TYPE "Power Supply UPS Status Change" --#SUMMARY "Storage system power supply UPS status changed to %d." --#ARGUMENTS {5} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8018 cpqSsExTempSensorStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsTempSensorLocation, cpqSsTempSensorStatus, cpqSsTempSensorCurrentValue } DESCRIPTION "Storage system temperature sensor status change. The agent has detected a change in the status of a Compaq storage system temperature sensor. The variable cpqSsTempSensorStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated." --#TYPE "Temperature Sensor Status Change" --#SUMMARY "Storage system temperature sensor status changed to %d." --#ARGUMENTS {5} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8019 cpqSsEx2FanStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsFanModuleLocation, cpqSsFanModuleStatus, cpqSsFanModuleSerialNumber, cpqSsFanModuleBoardRevision } DESCRIPTION "Storage system fan status change. The agent has detected a change in the fan module status of a Compaq storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans." --#TYPE "Fan Status Change" --#SUMMARY "Storage system fan status changed to %d." --#ARGUMENTS {5} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8020 cpqSsEx2PowerSupplyStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsPowerSupplyBay, cpqSsPowerSupplyStatus, cpqSsPowerSupplySerialNumber, cpqSsPowerSupplyBoardRevision, cpqSsPowerSupplyFirmwareRevision } DESCRIPTION "Storage system power supply status change. The agent has detected a change in the power supply status of a Compaq storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply." --#TYPE "Power Supply Status Change" --#SUMMARY "Storage system power supply status changed to %d." --#ARGUMENTS {5} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8021 cpqSsExBackplaneFanStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsBackplaneIndex, cpqSsBackplaneVendor, cpqSsBackplaneModel, cpqSsBackplaneSerialNumber, cpqSsBackplaneFanStatus } DESCRIPTION "Storage system fan status change. The agent has detected a change in the fan status of a Compaq storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans." --#TYPE "Storage System Fan Status Change" --#SUMMARY "Storage system fan status changed to %d." --#ARGUMENTS {8} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8022 cpqSsExBackplaneTempStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsBackplaneIndex, cpqSsBackplaneVendor, cpqSsBackplaneModel, cpqSsBackplaneSerialNumber, cpqSsBackplaneTempStatus } DESCRIPTION "Storage system temperature status change. The agent has detected a change in the status of the temperature in a Compaq storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated." --#TYPE "Storage System Temperature Status Change" --#SUMMARY "Storage system temperature status changed to %d." --#ARGUMENTS {8} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8023 cpqSsExBackplanePowerSupplyStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsBackplaneIndex, cpqSsBackplaneVendor, cpqSsBackplaneModel, cpqSsBackplaneSerialNumber, cpqSsBackplaneFtpsStatus } DESCRIPTION "Storage system power supply status change. The agent has detected a change in the power supply status of a Compaq storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply." --#TYPE "Power Supply Status Change" --#SUMMARY "Storage system power supply status changed to %d." --#ARGUMENTS {8} --#SEVERITY CRITICAL --#TIMEINDEX 99 ::= 8024 cpqSsExRecoveryServerStatusChange TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName, cpqSsChassisTime, cpqSsChassisRsoStatus, cpqSsChassisIndex } DESCRIPTION "Storage system recovery server option status change. The agent has detected a change in the recovery server option status of a Compaq storage system. The variable cpqSsChassisRsoStatus indicates the current status. User Action: If the RSO status is noSecondary(6) or linkDown(7), insure the secondary server is operational and all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or secondaryRunningUser(9), examine the the primary server for failed components." --#TYPE "Recovery Server Option Status Change" --#SUMMARY "Storage system recovery server option status changed to %d." --#ARGUMENTS {4} --#SEVERITY MAJOR --#TIMEINDEX 99 ::= 8025 END