-- ***************************************************************** -- ciscoWanParMIB: MIB For Portable AutoRoute(PAR) Controller -- in MGX82xx products. -- -- September 2002, Subra Hegde -- -- Copyright (c) 2002 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** CISCO-WAN-PAR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TruthValue, DisplayString FROM SNMPv2-TC par FROM BASIS-MIB ciscoWan FROM CISCOWAN-SMI; ciscoWanParMIB MODULE-IDENTITY LAST-UPDATED "200209100000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO " Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com" DESCRIPTION "The MIB module for configuring AutoRoute controller. The Portable AutoRoute(PAR) is a Controller providing routing capabilities in Network of Cisco MGX and BPX Switches. PAR controller performs following functions: - Connection Provisioning. Adding/Deleting/modifying connections - Connection Alarm Management. On receipt of a failure event, PAR sends messages to condition the connection. - Annex G functionality. Manages the LMI communication between feeder and routing node. - Clocking Control. PAR handles the clocking selection for the switch." REVISION "200209100000Z" DESCRIPTION "Initial version of the MIB. The content of this MIB was originally available in CISCO-WAN-AXIPOP-MIB defined using SMIv1. The applicable objects from CISCO-WAN-AXIPOP-MIB are defined using SMIv2 in this MIB. Also the descriptions of some of the objects have been modified." ::= { ciscoWan 63 } parSelfNode OBJECT IDENTIFIER ::= { par 1 } parInterfaces OBJECT IDENTIFIER ::= { par 2 } parConnection OBJECT IDENTIFIER ::= { par 3 } parNetworkClock OBJECT IDENTIFIER ::= { par 4 } parConfigParms OBJECT IDENTIFIER ::= { par 5 } parVsiConfigParms OBJECT IDENTIFIER ::= { parConfigParms 1 } parCmParms OBJECT IDENTIFIER ::= { parConfigParms 2 } parMnUpdt OBJECT IDENTIFIER ::= { parConfigParms 3 } parSwFunc OBJECT IDENTIFIER ::= { parConfigParms 4 } parOnOff OBJECT IDENTIFIER ::= { parConfigParms 5 } parSysParms OBJECT IDENTIFIER ::= { parConfigParms 6 } parNetworkingParms OBJECT IDENTIFIER ::= { parConfigParms 7 } parSnNodeId OBJECT-TYPE SYNTAX Integer32(1..223) MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the node number of the node. When the network manager tries to modify the value of this object, a message is sent node state machine which propagates this information and the value gets modified only if the new node number is successfully propagated. The node number uniquely identifies a routing node in a network." DEFVAL { 1 } ::= { parSelfNode 1} parSnNodeIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the IP address for routing node and is used for communication with SNMP manager(for example Cisco Wan Manager:CWM)." ::= { parSelfNode 2} parSnNodeName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the name of the node and is unique among all the nodes in the network. Whenever the name of the node is changed, AutoRoute has to propagate the information to the other nodes in the network. It also specifies the name of a PAR Feeder node." ::= { parSelfNode 3} parSnRevision OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the primary revision of the PAR running on the node. Format: cc.c.cc Where: c = one ascii character" ::= { parSelfNode 4} parSnNodeAlarmStatus OBJECT-TYPE SYNTAX INTEGER { clear (1), minor (2), major (3), unreach (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the type of alarm on the node. clear(1) : No Alarm minor(2) : Minor Alarm major(3) : Major Alarm unreach(4) : Node is unreachable." ::= { parSelfNode 5} parSnNumberOfTrunks OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the number of trunks attached to the node." ::= { parSelfNode 6} -- parInterfaces parIfTable OBJECT-TYPE SYNTAX SEQUENCE OF ParIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of all logical interfaces supported by PAR" ::= { parInterfaces 1} parIfEntry OBJECT-TYPE SYNTAX ParIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for logical interfaces." INDEX { parIfLogicalInterface } ::= { parIfTable 1} ParIfEntry ::= SEQUENCE { parIfLogicalInterface Integer32, parIfType INTEGER, parIfOperStatus INTEGER, parIfTxBw Integer32, parIfRxBw Integer32, parIfMaxConn Integer32, parIfHiAddrMin Integer32, parIfHiAddrMax Integer32, parIfLoAddrMin Integer32, parIfLoAddrMax Integer32 } parIfLogicalInterface OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the logical interface number." ::= { parIfEntry 1} parIfType OBJECT-TYPE SYNTAX INTEGER { userport (1), routingtrunk (2), feedertrunk (3), clkport (4), virtualtrunk (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the type of interface. User ports need to be UNI interface. The trunks can be either UNI or NNI. userport(1) : UNI interface. This is for user ports. routingtrunk(2) : NNI interface. This value can be set provided there are no connections on the interface. feedertrunk(3) : It is feeder trunk. clkport(4) : Clock port. virtualtrunk(5): Virtual Trunk. Type of interface can be changed from nni(2) to uni(1) if the trunk is not added." DEFVAL {userport } ::= { parIfEntry 2} parIfOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), added (2), failed (3), added-failed (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the operation status of the interface. up(1) : Interface is up. This value is applicable for UNI as well as NNI interfaces. added(2) : Interface is added. This value is applicable for NNI interfaces. failed(3) : Interface is failed. This value is applicable for UNI as well as NNI interfaces. added-failed (4) : Interface is failed. This value is applicable for NNI interfaces. interfaces." ::= { parIfEntry 3} parIfTxBw OBJECT-TYPE SYNTAX Integer32 UNITS "cells-per-second" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the transmit bandwidth for the interface." ::= { parIfEntry 4} parIfRxBw OBJECT-TYPE SYNTAX Integer32 UNITS "cells-per-second" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the receive bandwidth for the interface." ::= { parIfEntry 5} parIfMaxConn OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum number of connections that can be configured over the interface." ::= { parIfEntry 6} parIfHiAddrMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the minimum VPI that PAR can use for configuring connection in the interface." ::= { parIfEntry 7} parIfHiAddrMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum VPI that PAR can use for configuring connection in the interface." ::= { parIfEntry 8} parIfLoAddrMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the minimum VCI that PAR can use for configuring connection in the interface." ::= { parIfEntry 9} parIfLoAddrMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum VCI that PAR can use for configuring connection in the interface." ::= { parIfEntry 10} parTrkTable OBJECT-TYPE SYNTAX SEQUENCE OF ParTrkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table containing trunk parameters." ::= { parInterfaces 2} parTrkEntry OBJECT-TYPE SYNTAX ParTrkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for logical interfaces configured as trunks (parIfType nni)." INDEX { parIfLogicalInterface } ::= { parTrkTable 1} ParTrkEntry ::= SEQUENCE { parTrkId Integer32, parTrkStatReserve Integer32, parTrkCnfgCcRestrict TruthValue, parTrkCnfgLineType INTEGER, parTrkCnfgPassSync TruthValue, parTrkCnfgDerouteDelay Integer32, parTrkCnfgTrafficClassFst TruthValue, parTrkCnfgTrafficClassFr TruthValue, parTrkCnfgTrafficClassNts TruthValue, parTrkCnfgTrafficClassTs TruthValue, parTrkCnfgTrafficClassVoice TruthValue, parTrkCnfgTrafficClassCbr TruthValue, parTrkCnfgTrafficClassVbr TruthValue, parTrkCnfgTrafficClassAbr TruthValue, parTrkCnfgAdminStatus INTEGER, parTrkCnfgRoutingCost Integer32, parTrkCnfgVpcConids Integer32, parTrkCnfgVccConids Integer32, parTrkLocalSlotNumber Integer32, parTrkLocalPortNumber Integer32, parTrkLocalVTrunkId Integer32, parTrkRemoteNodeId Integer32, parTrkRemoteTrunkId Integer32, parTrkRemoteSlotNumber Integer32, parTrkRemotePortNumber Integer32, parTrkRemoteVTrunkId Integer32, parTrkRemoteNodeIP IpAddress, parTrkRemoteNodeType INTEGER, parTrkRemoteNodeName DisplayString, parTrkAlarmStatus INTEGER, parTrkAlarmType INTEGER, parTrkLineLoad Integer32, parTrkBwCapacity Integer32 } parTrkId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the logical trunk number associated with the trunk at the local node." ::= { parTrkEntry 1} parTrkStatReserve OBJECT-TYPE SYNTAX Integer32 UNITS "cells-per-second" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the bandwidth reserved as Statistical Reserve on the trunk in units of cells per second. This object cannot take a value beyond the bandwidth capacity of the trunk." DEFVAL { 1000} ::= { parTrkEntry 2} parTrkCnfgCcRestrict OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the operators preference for routing control plane traffic on the interface. If the object is set to False, then the interface may be chosen for control plane traffic. If it is True, then the interface is not chosen, unless there is no other trunk with parIfOperStatus added(2), in which case it is chosen regardless of the value of this object." DEFVAL { false } ::= { parTrkEntry 3} parTrkCnfgLineType OBJECT-TYPE SYNTAX INTEGER { terrestrial (1), satellite (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the type of interface terrestrial or satellite. The interfaces configured as terrestrial(1) are preferred over those configured as satellite(2) for routing control plane traffic. This information is also used for connections for which routing restrictions are specified." DEFVAL { terrestrial } ::= { parTrkEntry 4} parTrkCnfgPassSync OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether the trunk can be used to pass clock sync. If the value of this object is True, clock can be synchronized through the trunk; otherwise not." DEFVAL { true} ::= { parTrkEntry 5} parTrkCnfgDerouteDelay OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the value of deroute delay timer in seconds." DEFVAL { 0 } ::= { parTrkEntry 6} parTrkCnfgTrafficClassFst OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Foresight traffic can be routed over the trunk. If the value is true(1), it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 7} parTrkCnfgTrafficClassFr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Frame Relay traffic can be routed over the trunk. If the value is true(1), it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 8} parTrkCnfgTrafficClassNts OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Non-Time Stamped traffic can be routed over the trunk. If the value is true(1) it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 9} parTrkCnfgTrafficClassTs OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Time Stamped traffic can be routed over the trunk. If the value is true(1) it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 10} parTrkCnfgTrafficClassVoice OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Voice traffic can be routed over the trunk. If the value is true(1), it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 11} parTrkCnfgTrafficClassCbr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Constant Bit Rate traffic can be routed over the trunk. If the value is true(1), it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 12} parTrkCnfgTrafficClassVbr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Variable Bit Rate traffic can be routed over the trunk. If the value is true(1), it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 13} parTrkCnfgTrafficClassAbr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Available Bit Rate traffic can be routed over the trunk. If the value is true(1), it can be rerouted otherwise not." DEFVAL { true } ::= { parTrkEntry 14} parTrkCnfgAdminStatus OBJECT-TYPE SYNTAX INTEGER { add (1), delete (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to add or delete the trunk. The value of this object can be set to add(1) only if the parIfOperStatus is up(1). The value can be set to delete if parIfOperStatus is added or added-failed" DEFVAL { delete } ::= { parTrkEntry 15} parTrkCnfgRoutingCost OBJECT-TYPE SYNTAX Integer32 (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the cost associated with the trunk for the purpose of routing the connections. This object has significance if cost based routing feature is enabled(parCmParmsCostBased)" DEFVAL { 7 } ::= { parTrkEntry 16} parTrkCnfgVccConids OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of routing resource available on the trunk for VCC connections." ::= { parTrkEntry 17} parTrkCnfgVpcConids OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of routing resource available on the trunk for VPC connections" ::= { parTrkEntry 18} parTrkLocalSlotNumber OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the slot number of the interface card associated with the trunk at the local node." ::= { parTrkEntry 19} parTrkLocalPortNumber OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the port number of the interface card associated with the trunk at the local node." ::= { parTrkEntry 20} parTrkLocalVTrunkId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Virtual trunk of the interface card associated with the trunk at the local node. The value of this object is between 1 and 254, inclusive for a virtual trunk and 255 for a physical trunk." ::= { parTrkEntry 21} parTrkRemoteNodeId OBJECT-TYPE SYNTAX Integer32 (1..223) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the node number of the node attached to the remote end of the trunk." ::= { parTrkEntry 22} parTrkRemoteTrunkId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the logical trunk number at the node on the remote end of the trunk." ::= { parTrkEntry 23} parTrkRemoteSlotNumber OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the slot number of the interface card to which the trunk is attached on the remote node." ::= { parTrkEntry 24} parTrkRemotePortNumber OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the port number of the interface card to which the trunk is attached on the remote node." ::= { parTrkEntry 25} parTrkRemoteVTrunkId OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Virtual trunk of the interface card associated with the trunk at the remote node. The value of this object is between 1 and 254, inclusive for a virtual trunk and 255 for a physical trunk." ::= { parTrkEntry 26} parTrkRemoteNodeIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the IP address for the Remote node, used for communication with NMS" ::= { parTrkEntry 27} parTrkRemoteNodeType OBJECT-TYPE SYNTAX INTEGER{ ipx (1), igx (2), bpx (3), par (4), unknown (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the type of the node." ::= { parTrkEntry 28} parTrkRemoteNodeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the name of the remote node and is unique among all the nodes in the network." ::= { parTrkEntry 29} parTrkAlarmStatus OBJECT-TYPE SYNTAX INTEGER { clear (1), minor (2), major (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the severity of the alarm on the trunk. clear(1) : No Alarm minor(2) : Minor Alarm major(3) : Major Alarm." ::= { parTrkEntry 30} parTrkAlarmType OBJECT-TYPE SYNTAX INTEGER{ rsrcunavail (1), commfail (2), unknown (3), failed (4), looped (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the type of alarm on the trunk. The value of this object has no significance if parTrunkAlarmStatus indicates no alarm. rsrcunavail(1) : resources unavailable indicates that the platform has not provided the resources required to make this interface into a trunk. commfail(2) : communication failure indicates that message exchanged between neighboring nodes on this trunk has failed. unknown (3) : indicates that the alarm type is unknown to PAR, for example if the platform has declared the interface in alarm due to some physical problem with the interface." ::= { parTrkEntry 31} parTrkBwCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the bandwidth capacity of the trunk." ::= { parTrkEntry 32} parTrkLineLoad OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the bandwidth used by the connections routed over the trunk." ::= { parTrkEntry 33} parTrkLoadTable OBJECT-TYPE SYNTAX SEQUENCE OF ParTrkLoadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trunk Load Information" ::= { parInterfaces 3} parTrkLoadEntry OBJECT-TYPE SYNTAX ParTrkLoadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Load info for logical interfaces configured as trunks (parIfType nni)." INDEX { parIfLogicalInterface } ::= { parTrkLoadTable 1} ParTrkLoadEntry ::= SEQUENCE { parTrkLoadXmtUsedCbr Integer32, parTrkLoadRcvUsedCbr Integer32, parTrkLoadXmtUsedVbr Integer32, parTrkLoadRcvUsedVbr Integer32, parTrkLoadXmtUsedAbr Integer32, parTrkLoadRcvUsedAbr Integer32, parTrkLoadXmtUsedNts Integer32, parTrkLoadRcvUsedNts Integer32, parTrkLoadXmtUsedTs Integer32, parTrkLoadRcvUsedTs Integer32, parTrkLoadXmtUsedVoice Integer32, parTrkLoadRcvUsedVoice Integer32, parTrkLoadXmtUsedBdataA Integer32, parTrkLoadRcvUsedBdataA Integer32, parTrkLoadXmtUsedBdataB Integer32, parTrkLoadRcvUsedBdataB Integer32, parTrkLoadVccConidsUsed Integer32, parTrkLoadVpcConidsUsed Integer32 } parTrkLoadXmtUsedCbr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for CBR traffic." ::= { parTrkLoadEntry 1} parTrkLoadRcvUsedCbr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for CBR traffic" ::= { parTrkLoadEntry 2} parTrkLoadXmtUsedVbr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for VBR traffic." ::= { parTrkLoadEntry 3} parTrkLoadRcvUsedVbr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for VBR traffic." ::= { parTrkLoadEntry 4} parTrkLoadXmtUsedAbr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for ABR." ::= { parTrkLoadEntry 5} parTrkLoadRcvUsedAbr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for ABR." ::= { parTrkLoadEntry 6} parTrkLoadXmtUsedNts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for Non-Time Stamped." ::= { parTrkLoadEntry 7} parTrkLoadRcvUsedNts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for Non-Time Stamped." ::= { parTrkLoadEntry 8} parTrkLoadXmtUsedTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for Time-Stamped." ::= { parTrkLoadEntry 9} parTrkLoadRcvUsedTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for Time-Stamped." ::= { parTrkLoadEntry 10} parTrkLoadXmtUsedVoice OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for Voice." ::= { parTrkLoadEntry 11} parTrkLoadRcvUsedVoice OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for Voice." ::= { parTrkLoadEntry 12} parTrkLoadXmtUsedBdataA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for Busty Data A." ::= { parTrkLoadEntry 13} parTrkLoadRcvUsedBdataA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for Bursty Data A." ::= { parTrkLoadEntry 14} parTrkLoadXmtUsedBdataB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the transmit direction for Bursty Data B." ::= { parTrkLoadEntry 15} parTrkLoadRcvUsedBdataB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the used bandwidth in the receive direction for Bursty Data B." ::= { parTrkLoadEntry 16} parTrkLoadVccConidsUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the number of conids used for VCCs (not used) on the trunk." ::= { parTrkLoadEntry 17} parTrkLoadVpcConidsUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the number of conids Used for VPCs (not used) on the trunk." ::= { parTrkLoadEntry 19} -- parConnection parConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF ParConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains connections Mastered or slaved by the node." ::= { parConnection 1} parConnectionEntry OBJECT-TYPE SYNTAX ParConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for connections mastered or slaved by the node. Each entry contains Local and remote end information." INDEX { parConnLocalSlot, parConnLocalPort, parConnLocalVpi, parConnLocalVci } ::= { parConnectionTable 1} ParConnectionEntry ::= SEQUENCE { parConnLocalSlot Integer32, parConnLocalPort Integer32, parConnLocalVpi Integer32, parConnLocalVci Integer32, parConnMasterShip TruthValue, parConnLocalVcIndx Integer32, parConnLocalEndpt DisplayString, parConnRemoteNodeName DisplayString, parConnRemoteSlot Integer32, parConnRemotePort Integer32, parConnRemoteVpi Integer32, parConnRemoteVci Integer32, parConnRemoteVcIndx Integer32, parConnRemoteEndpt DisplayString, parConnOperStatus INTEGER, parConnAdminStatus INTEGER, parConnRoute DisplayString, parPrefRoute DisplayString, parConnFailRsn INTEGER, parRrtFailRsn DisplayString, parConnRstrTyp INTEGER, parConnRstrZcs TruthValue, parConnCos Integer32 } parConnLocalSlot OBJECT-TYPE SYNTAX Integer32(1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the slot number part of the local endpoint connection address." ::= { parConnectionEntry 1} parConnLocalPort OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the port number part of the local endpoint connection address." ::= { parConnectionEntry 2} parConnLocalVpi OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Virtual Path Identifier part of the local endpoint connection address." ::= { parConnectionEntry 3} parConnLocalVci OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Virtual Channel Identifier part of the local endpoint connection address." ::= { parConnectionEntry 4} parConnMasterShip OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies whether this end of the connection is the master or the slave of the connection. The value true(1) signifies the master end and false(2) signifies slave end." ::= { parConnectionEntry 5} parConnLocalVcIndx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Virtual Connection Index at this node. It is used by Network Management to correlate this end of the connection with the remote end." ::= { parConnectionEntry 6} parConnLocalEndpt OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the actual physical connection endpoint at the local node." ::= { parConnectionEntry 7} parConnRemoteNodeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the node name of the remote endpoint. For a intra-switch connection or feeder connection this object would specify the self node name." ::= { parConnectionEntry 8} parConnRemoteSlot OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the slot number part of the remote endpoint connection address." ::= { parConnectionEntry 9} parConnRemotePort OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the port number part of the remote endpoint connection address." ::= { parConnectionEntry 10} parConnRemoteVpi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the VPI part of the remote endpoint connection address." ::= { parConnectionEntry 11} parConnRemoteVci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the VCI part of the remote endpoint connection address." ::= { parConnectionEntry 12} parConnRemoteVcIndx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Virtual Connection Index at the remote node. It is used by Network Management to correlate this end of the connection with the remote end.." ::= { parConnectionEntry 13} parConnOperStatus OBJECT-TYPE SYNTAX INTEGER { routed (1), unrouted (2), lmifail (3), unknown (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the status of connection as known and determined by PAR. The status shall be OK if there is an A-bit alarm on the connection." ::= { parConnectionEntry 14} parConnAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2), reroute (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used by the operator to reroute or down/up a connection. The value of this object is up(1) when the connection is created. If the value of the object is set to down(1) the connection is derouted (if it is routed) and parConnOperStatus object is set to not routed. If the value of the object is up (2) and it is set to reroute(3) the connection is derouted and attempt is made to reroute the connection. If the value of the object is down (1) and the it is set to reroute (3), no action is performed and the object's value does not changes. If the value of object is down(1) and is set to up(2), an attempt is made to reroute the connection." DEFVAL { up } ::= { parConnectionEntry 15} parConnRoute OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the current path on which the connection is routed. A value of this object is valid only if parConnOperStatus is routed. The Null string specifies that the connection is not routed. Format: Nodename {Trk--Trk Nodename} Where: Nodename = up to 8 characters, Trk = slot.port.vtrk, slot = 1 or 2 characters, port = 1 or two characters, and vtrk = 1 or two characters and is optional. The portion of the format shown in braces {like this} can be repeated up to 10 times." ::= { parConnectionEntry 16} parConnRemoteEndpt OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the actual physical connection endpoint at the remote end of the connection. It shall be known only if the connection is a local(DAX) connection." ::= { parConnectionEntry 17} parPrefRoute OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the preferred path for the connection. The Null string specifies that the connection does not have a preferred route. Format: Nodename {Trk--Trk Nodename} Where: Nodename = up to 8 characters, Trk = slot.port.vtrk, slot = 1 or 2 characters, port = 1 or two characters, and vtrk = 1 or two characters and is optional. The portion of the format shown in braces {like this} can be repeated up to 10 times." ::= { parConnectionEntry 18} parConnFailRsn OBJECT-TYPE SYNTAX INTEGER { down(1), hwalm(2), abitalm(3), lmifail(4), rrtfail(5), incomplete(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies a reason code for the failure of the connection." ::= {parConnectionEntry 19} parRrtFailRsn OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Reason of failure of a connection to route." ::= {parConnectionEntry 20} parConnRstrTyp OBJECT-TYPE SYNTAX INTEGER { norestrict (1), terrestrict (2), satrestrict (3), undefrestrict (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the Route restriction of a connection." ::= {parConnectionEntry 21} parConnRstrZcs OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies whether ZCS lines should be avoided or not." ::= {parConnectionEntry 22} parConnCos OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the COS for the connection." ::= {parConnectionEntry 23} -- parNetworkClock parClockTable OBJECT-TYPE SYNTAX SEQUENCE OF ParClockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of clock sources available to PAR" ::= { parNetworkClock 1} parClockEntry OBJECT-TYPE SYNTAX ParClockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represent a clock source available to PAR" INDEX { parClockIndex } ::= { parClockTable 1} ParClockEntry ::= SEQUENCE { parClockIndex Integer32, parClockType INTEGER, parClockCurSource TruthValue, parClockSource INTEGER, parClockSourceId Integer32, parClockPath DisplayString } parClockIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This clock index is assigned by PAR." ::= { parClockEntry 1} parClockType OBJECT-TYPE SYNTAX INTEGER{ primary (1), secondary (2), tertiary (3), null (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the type of clock." ::= { parClockEntry 2} parClockSource OBJECT-TYPE SYNTAX INTEGER{ internal (1), interface (2), external (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies source of the clock." DEFVAL { internal } ::= { parClockEntry 3} parClockCurSource OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether clock source is a current clock source or not. The value is true if the cloock source is current and false otherwise" DEFVAL {false} ::= { parClockEntry 4} parClockSourceId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies identification of the clock - for example - if clock source is `Interface' then this field will carry logical interface number" ::= { parClockEntry 5} parClockPath OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the path used for clock synchronization" ::= { parClockEntry 6} parCmParmsMaxRoutingBundle OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of connections that can be routed in one routing cycle." DEFVAL { 24 } ::= { parCmParms 1} parCmParmsRerouteTimer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum time after which a connection is routed once it has been successfully routed." DEFVAL { 0 } ::= { parCmParms 2} parCmParmsResetTimer OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether the reroute timer should be reset if the path for routed connection failed. If the value of the object is true(1), the timer is reset on detecting path fail." DEFVAL { true } ::= { parCmParms 3} parCmParmsDnUpPerPass OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of connections that are upped or down in one schedule of down connection state machine." DEFVAL { 50 } ::= { parCmParms 4} parCmParmsDnUpTimer OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum time interval (in milliseconds) between two schedules of the down connection state machine." DEFVAL { 30000 } ::= { parCmParms 5} parCmParmsRrtErrsPerCycle OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the threshold for number of failures to route a connection before it is moved into the wait group. If the value of this object is zero, the feature is disabled." DEFVAL { 50 } ::= { parCmParms 6} parCmParmsRrtCycleInterval OBJECT-TYPE SYNTAX Integer32 UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the time (in minutes) for which no attempt is made to route a connection in the wait group." DEFVAL { 5 } ::= { parCmParms 7} parCmParmsMaxRrtCycles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the number of times a connection is added to the wait group before declaring it unroutable." DEFVAL { 10 } ::= { parCmParms 8} parCmParmsRrtPauseTime OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the time interval (in milliseconds) between two routing cycles." DEFVAL { 0 } ::= { parCmParms 9} parCmParmsMaxUpdates OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of connection management updates that are sent by the node in schedule.." DEFVAL { 10 } ::= { parCmParms 10} parCmParmsRerouteGroups OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the total number of reroute groups." DEFVAL { 50 } ::= { parCmParms 11} parCmParmsMinRrGroupSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum size of reroute group in Cell Load Units." DEFVAL { 0 } ::= { parCmParms 12} parCmParmsRrGroupInc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the increment of reroute group size (in Cell Load Units) between adjacent groups." DEFVAL { 100 } ::= { parCmParms 13} parCmParmsCostBased OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be configured to enable or disable cost based routing feature. If the value of this object is true(1), the feature is enabled else it is disabled." DEFVAL { false } ::= { parCmParms 14} parCmParmsUseCache OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be configured to enable or disable hop based route selection from using cache of precomputed routes. If the value of this object is true(1), the feature is enabled else it is disabled." DEFVAL { false } ::= { parCmParms 15} parCmParmsUseDelay OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be configured to enable or disable cost based route selection from considering end-to-end delay associated with the routes. If the value of this object is true(1), the delay would be considered otherwise daley would not be considered during routing of connection." DEFVAL { false } ::= { parCmParms 16} parCmParmMaxViaCons OBJECT-TYPE SYNTAX Integer32 (1..80000) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of via user connections that can be routed through the node." DEFVAL { 50000 } ::= { parCmParms 17} parMnUpdtInterval OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the timer interval (in seconds) for the current update state machine." DEFVAL { 15 } ::= { parMnUpdt 1} parMnUpdtNodesPerInt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of nodes to which current updates can be sent per interval." DEFVAL { 20 } ::= { parMnUpdt 2} parMnUpdtBatchSend OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether current updates to any node are sent one at a time or all in one go. If the value of this object is true(1), all current updates are sent to the node simultaneously. If the value of this object is False, current updates are sent one at a time." DEFVAL { true } ::= { parMnUpdt 3} parSwFuncAbrVsvd OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables/disables the ABR standard with VSVD. The feature is enabled if the value of the object is true(1)." DEFVAL { false } ::= { parSwFunc 1} parSwFuncNodeType OBJECT-TYPE SYNTAX INTEGER { routing (1), feeder (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether the node is a routing node or a feeder node. To configure the node from a routing(1) node to feeder(2) node the node should be part of a single node network. To configure the node from feeder node to routing node, there should be no feeder trunk attached to the node." DEFVAL { routing } ::= { parSwFunc 2} parOnOffBackgroundUpdt OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable Background updates. If the value of the object is true(1), background updates are enabled; otherwise they are disabled." DEFVAL { false } ::= { parOnOff 1} parOnOffDynamicBwAlloc OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable Bandwidth state machine. If the value of the object is true(1), bandwidth state machine is enabled; otherwise it is disabled." DEFVAL { true } ::= { parOnOff 2} parOnOffCmUpdts OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable connection management updates. If the value of the object is true(1), connection management updates are enabled; otherwise they are disabled." DEFVAL { true } ::= { parOnOff 3} parOnOffRouting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable connection routing. If the value of the object is true(1), routing is enabled; otherwise it is disabled." DEFVAL { true } ::= { parOnOff 4} parOnOffCommFailTest OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable Comm Fail Test. If the value of the object is true(1), Comm Fail test is enabled; otherwise it is disabled." DEFVAL { true } ::= { parOnOff 5} parOnOffDrtDelay OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable Deroute Delay feature. If the value of the object is true(1) Derote delay feature is enabled; otherwise it is disabled." DEFVAL { true } ::= { parOnOff 6} parOnOffRenumRec OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable Renumber recovery feature. If the value of the object is true(1), renumber recovery feature is enabled; otherwise it is disabled." DEFVAL { false } ::= { parOnOff 7} parOnOffCommBreak OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can be used to enable or disable Comm Break Test. If the value of the object is true(1), Comm Break Test feature is enabled; otherwise it is disabled." DEFVAL { false } ::= { parOnOff 8} parSysParmsTsPacketAge OBJECT-TYPE SYNTAX Integer32(1..64) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Time Stamped packets older than this value (in milliseconds)are discarded. This is a network wide parameter." DEFVAL { 64 } ::= { parSysParms 1} parSysParmsConnFail OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether the connections to a node should be failed when comm fail is declared with the node. If the value of this object is true(1), the connection will be failed. This is a network wide parameter." DEFVAL {false} ::= { parSysParms 2} parSysParmsVcPollRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the rate at which VC statistics are to be polled. This is a network wide parameter. For Portable AutoRoute statistic collections would be done by platform software." ::= { parSysParms 3} parSysParmsMaxVDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum delay for voice connection with VAD enabled in milli-seconds. This is a network wide parameter." ::= { parSysParms 4} parSysParmsMaxCDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum delay for ADPCM compressed voice connection with VAD enabled in milli-seconds. This is a network wide parameter." ::= { parSysParms 5} parSysParmsMaxDDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum delay for data connection in milli-seconds. This is a network wide parameter." ::= { parSysParms 6} parSysParmsMaxADelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum delay for ADPCM compressed voice connection in milli-seconds. This is a network wide parameter." ::= { parSysParms 7} parSysParmsMaxHsdDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum delay for High Speed data connection in milli-seconds. This is a network wide parameter." ::= { parSysParms 8} parSysParmsDeEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies whether DE bit of Frame Relay frames can be modified. DE bit can be modified if the value of this object is true(1). This is a network wide parameter." ::= { parSysParms 9} parSysParmsFrStandard OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies whether standard Frame Relay parameters,Be and Bc, are to be used. If the value of this object is true(1), standard parameters are used. This is a network wide parameter." ::= { parSysParms 10} parSysParmsDrtDelay OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies whether Deroute Delay feature is enabled. If the value of this object is true(1), the feature is enabled. This is a network wide parameter." DEFVAL { true } ::= { parSysParms 11} parSysParmsInvLogAlarmThres OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the threshold for invalid login attempts before triggering an alarm. If the value of this object is zero, this feature is disabled. This is a network wide parameter." DEFVAL { 0 } ::= { parSysParms 12} parSysParmsMaxCdpVDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum network delay for CDP to CDP voice connection with VAD enabled in milli-seconds. This is a network wide parameter." ::= { parSysParms 13} parSysParmsMaxCdpCDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum network delay for CDP to CDP ADPCM compressed voice connection with VAD enabled. This is a network wide parameter." ::= { parSysParms 14} parSysParmsMaxCdpDDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum network delay for CDP to CDP data connection. This is a network wide parameter." ::= { parSysParms 15} parSysParmsMaxCdpADelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum network delay for CDP to CDP ADPCM compressed voice connection. This is a network wide parameter." ::= { parSysParms 16} parSysParmsMaxCdpHsdDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum network delay for CDP to CDP High Speed data connection. This is a network wide parameter." ::= { parSysParms 17} parSysParmsMaxIpcdpVDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum local delay for CDP to CDP voice connection with VAD enabled. This is a network wide parameter." ::= { parSysParms 18} parSysParmsMaxIpcdpCDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum local delay for CDP to CDP ADPCM compressed voice connection with VAD enabled. This is a network wide parameter." ::= { parSysParms 19} parSysParmsMaxIpcdpDDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum local delay for CDP to CDP data connection. This is a network wide parameter." ::= { parSysParms 20} parSysParmsMaxIpcdpADelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum local delay for CDP to CDP ADPCM compressed voice connection. This is a network wide parameter." ::= { parSysParms 21} parSysParmsMaxIpcdpHsdDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum local delay for CDP to CDP High Speed data connection. This is a network wide parameter." ::= { parSysParms 22} parSysParmsMaxIphsdDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the maximum local delay for High Speed data connection. This is a network wide parameter." ::= { parSysParms 23} parSysParmsFpdDeJitter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the jitter delay for Fast Pad. This is a network wide parameter." ::= { parSysParms 24} parNetParmCondInitialStgr OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the initial pause time (in milliseconds) per new node added on addition of node(s) in the network before initiating conditional updates." DEFVAL { 5000 } ::= { parNetworkingParms 1} parNetParmCondPerNodeInterval OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum interval (in milliseconds) between sending of conditional updates to any two nodes." DEFVAL {30000} ::= { parNetworkingParms 2} parNetParmCbDelay OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum interval (in milliseconds) between initiating comm break tests between any two nodes." DEFVAL { 30000 } ::= { parNetworkingParms 3} parNetParmCbOffset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Offset for CB." DEFVAL { 10 } ::= { parNetworkingParms 4} parNetParmMsgTimeout OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the timeout (in milliseconds) for acknowledgment for control plane message sent to another node." DEFVAL { 1700 } ::= { parNetworkingParms 5} parNetParmMsgMaxTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of times a network handler timeout waiting for acknowledgment for control plane message sent to another node reachable through all terrestrial trunks." DEFVAL { 7 } ::= { parNetworkingParms 6} parNetParmMsgMaxTimeoutSat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of times a network handler timeout waiting for acknowledgment for control plane message sent to another node reachable through all satellite trunks." DEFVAL { 6 } ::= { parNetworkingParms 7} parNetParmBlindMaxTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of times a network handler timeout waiting for acknowledgment for control plane blind message sent to another node." DEFVAL { 4 } ::= { parNetworkingParms 8} parNetParmCbMaxTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of times a network handler timeout waiting for acknowledgment for comm break test message sent to another node." DEFVAL { 5 } ::= { parNetworkingParms 9} parNetParmCfTestInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum time interval between the comm fail tests for a trunk." DEFVAL { 10000 } ::= { parNetworkingParms 10} parNetParmCfTestMultiplier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the multiplier for the comm fail test interval for good trunks, that is, trunks not in comm fail." DEFVAL { 3 } ::= { parNetworkingParms 11} parNetParmNetwWindowSz OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the window size for the network handler for messages to any node. That is, the number of messages that the network handler can send simultaneous to a node without receiving the acknowledgment for them." DEFVAL { 1 } ::= { parNetworkingParms 12} parNetParmNetwLetWait OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum interval (in milliseconds) network handler waits for the letter (message) from the processes running on its nodes before checking the received cells." DEFVAL { 50 } ::= { parNetworkingParms 13} parNetParmCfDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "TBD (in milliseconds)." DEFVAL { 60 } ::= { parNetworkingParms 14} parNetParmHighTxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the rate (in fast packets per second) at which the network handler sends control plane message cells to high performance nodes (High performance node are BPX and MGX)." DEFVAL { 2500 } ::= { parNetworkingParms 15} parNetParmLowTxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the rate (in fast packets per second) at which the network handler sends control plane message cells to low capacity nodes (Low capacity node are IPX and IGX)." DEFVAL { 500 } ::= { parNetworkingParms 16} parNetParmMaxNodeBlks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum number of blocks of size 256 bytes, that should be queued up for transmission to a node." DEFVAL { 3000 } ::= { parNetworkingParms 17} parNetParmTopoMsgSegSz OBJECT-TYPE SYNTAX Integer32 UNITS "bytes" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum size (in bytes) of the segment into which the topology message, sent during network join, is divided." DEFVAL { 3570 } ::= { parNetworkingParms 18} -- conformance information cwParMIBConformance OBJECT IDENTIFIER ::= { ciscoWanParMIB 2 } cwParMIBGroups OBJECT IDENTIFIER ::= { cwParMIBConformance 1 } cwParMIBCompliances OBJECT IDENTIFIER ::= { cwParMIBConformance 2 } -- compliance statements cwParCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for objects related to AutoRoute MIB." MODULE -- this module MANDATORY-GROUPS{ cwParCmParamsGroup, cwParCmParamsUpdateGroup, cwParGeneralGroup, cwParSysParamsGroup, cwParNetParamsGroup, cwParNodeGroup, cwParInterfaceConfGroup, cwParTrunkConfGroup, cwParTrunkLoadConfGroup, cwParConnConfGroup, cwParClockConfGroup } ::= { cwParMIBCompliances 1 } cwParCmParamsGroup OBJECT-GROUP OBJECTS { parCmParmsMaxRoutingBundle, parCmParmsRerouteTimer, parCmParmsResetTimer, parCmParmsDnUpPerPass, parCmParmsDnUpTimer, parCmParmsRrtErrsPerCycle, parCmParmsRrtCycleInterval, parCmParmsMaxRrtCycles, parCmParmsRrtPauseTime, parCmParmsMaxUpdates, parCmParmsRerouteGroups, parCmParmsMinRrGroupSize, parCmParmsRrGroupInc, parCmParmsCostBased, parCmParmsUseCache, parCmParmsUseDelay, parCmParmMaxViaCons } STATUS current DESCRIPTION "The collection of objects which are applicable for PAR connection management." ::= { cwParMIBGroups 1 } cwParCmParamsUpdateGroup OBJECT-GROUP OBJECTS { parMnUpdtInterval, parMnUpdtNodesPerInt, parMnUpdtBatchSend } STATUS current DESCRIPTION "The collection of objects which are applicable for PAR Connection Management parameters updates." ::= { cwParMIBGroups 2 } cwParGeneralGroup OBJECT-GROUP OBJECTS { parSwFuncAbrVsvd, parSwFuncNodeType, parOnOffBackgroundUpdt, parOnOffDynamicBwAlloc, parOnOffCmUpdts, parOnOffRouting, parOnOffCommFailTest, parOnOffDrtDelay, parOnOffRenumRec, parOnOffCommBreak } STATUS current DESCRIPTION "The collection of objects which are applicable for general PAR configuration." ::= { cwParMIBGroups 3 } cwParSysParamsGroup OBJECT-GROUP OBJECTS { parSysParmsTsPacketAge, parSysParmsConnFail, parSysParmsVcPollRate, parSysParmsMaxVDelay, parSysParmsMaxCDelay, parSysParmsMaxDDelay, parSysParmsMaxADelay, parSysParmsMaxHsdDelay, parSysParmsDeEnable, parSysParmsFrStandard, parSysParmsDrtDelay, parSysParmsInvLogAlarmThres, parSysParmsMaxCdpVDelay, parSysParmsMaxCdpCDelay, parSysParmsMaxCdpDDelay, parSysParmsMaxCdpADelay, parSysParmsMaxCdpHsdDelay, parSysParmsMaxIpcdpVDelay, parSysParmsMaxIpcdpCDelay, parSysParmsMaxIpcdpDDelay, parSysParmsMaxIpcdpADelay, parSysParmsMaxIpcdpHsdDelay, parSysParmsMaxIphsdDelay, parSysParmsFpdDeJitter } STATUS current DESCRIPTION "The collection of objects which are applicable for PAR system parameters." ::= { cwParMIBGroups 4 } cwParNetParamsGroup OBJECT-GROUP OBJECTS { parNetParmCondInitialStgr, parNetParmCondPerNodeInterval, parNetParmCbDelay, parNetParmCbOffset, parNetParmMsgTimeout, parNetParmMsgMaxTimeout, parNetParmMsgMaxTimeoutSat, parNetParmBlindMaxTimeout, parNetParmCbMaxTimeout, parNetParmCfTestInterval, parNetParmCfTestMultiplier, parNetParmNetwWindowSz, parNetParmNetwLetWait, parNetParmCfDelay, parNetParmHighTxRate, parNetParmLowTxRate, parNetParmMaxNodeBlks, parNetParmTopoMsgSegSz } STATUS current DESCRIPTION "The collection of objects which are applicable for parameters applicable network-wide." ::= { cwParMIBGroups 5 } cwParNodeGroup OBJECT-GROUP OBJECTS { parSnNodeId, parSnNodeIP, parSnNodeName, parSnRevision, parSnNodeAlarmStatus, parSnNumberOfTrunks } STATUS current DESCRIPTION "The collection of objects which are applicable for node level configuration of auto route controller." ::= { cwParMIBGroups 6 } cwParInterfaceConfGroup OBJECT-GROUP OBJECTS { parIfLogicalInterface, parIfType, parIfOperStatus, parIfTxBw, parIfRxBw, parIfMaxConn, parIfHiAddrMin, parIfHiAddrMax, parIfLoAddrMin, parIfLoAddrMax } STATUS current DESCRIPTION "The collection of objects which are used for configuring autoroute interfaces." ::= { cwParMIBGroups 7 } cwParTrunkConfGroup OBJECT-GROUP OBJECTS { parTrkId, parTrkStatReserve, parTrkCnfgCcRestrict, parTrkCnfgLineType, parTrkCnfgPassSync, parTrkCnfgDerouteDelay, parTrkCnfgTrafficClassFst, parTrkCnfgTrafficClassFr, parTrkCnfgTrafficClassNts, parTrkCnfgTrafficClassTs, parTrkCnfgTrafficClassVoice, parTrkCnfgTrafficClassCbr, parTrkCnfgTrafficClassVbr, parTrkCnfgTrafficClassAbr, parTrkCnfgAdminStatus, parTrkCnfgRoutingCost, parTrkCnfgVpcConids, parTrkCnfgVccConids, parTrkLocalSlotNumber, parTrkLocalPortNumber, parTrkLocalVTrunkId, parTrkRemoteNodeId, parTrkRemoteTrunkId, parTrkRemoteSlotNumber, parTrkRemotePortNumber, parTrkRemoteVTrunkId, parTrkRemoteNodeIP, parTrkRemoteNodeType, parTrkRemoteNodeName, parTrkAlarmStatus, parTrkAlarmType, parTrkLineLoad, parTrkBwCapacity } STATUS current DESCRIPTION "The collection of objects which are used for configuring trunks in portable autoroute." ::= { cwParMIBGroups 8 } cwParTrunkLoadConfGroup OBJECT-GROUP OBJECTS { parTrkLoadXmtUsedCbr, parTrkLoadRcvUsedCbr, parTrkLoadXmtUsedVbr, parTrkLoadRcvUsedVbr, parTrkLoadXmtUsedAbr, parTrkLoadRcvUsedAbr, parTrkLoadXmtUsedNts, parTrkLoadRcvUsedNts, parTrkLoadXmtUsedTs, parTrkLoadRcvUsedTs, parTrkLoadXmtUsedVoice, parTrkLoadRcvUsedVoice, parTrkLoadXmtUsedBdataA, parTrkLoadRcvUsedBdataA, parTrkLoadXmtUsedBdataB, parTrkLoadRcvUsedBdataB, parTrkLoadVccConidsUsed, parTrkLoadVpcConidsUsed } STATUS current DESCRIPTION "The collection of objects which are used for configuring trunks in portable autoroute." ::= { cwParMIBGroups 9 } cwParConnConfGroup OBJECT-GROUP OBJECTS { parConnLocalSlot, parConnLocalPort, parConnLocalVpi, parConnLocalVci, parConnMasterShip, parConnLocalVcIndx, parConnLocalEndpt, parConnRemoteNodeName, parConnRemoteSlot, parConnRemotePort, parConnRemoteVpi, parConnRemoteVci, parConnRemoteVcIndx, parConnRemoteEndpt, parConnOperStatus, parConnAdminStatus, parConnRoute, parPrefRoute, parConnFailRsn, parRrtFailRsn, parConnRstrTyp, parConnRstrZcs, parConnCos } STATUS current DESCRIPTION "The collection of objects which are used for configuring trunks in portable autoroute." ::= { cwParMIBGroups 10 } cwParClockConfGroup OBJECT-GROUP OBJECTS { parClockIndex, parClockType, parClockCurSource, parClockSource, parClockSourceId, parClockPath } STATUS current DESCRIPTION "The collection of objects which are used for configuring trunks in portable autoroute." ::= { cwParMIBGroups 11 } END