-- ***************************************************************** -- CISCO-WAN-BBIF-ILMI-MIB: ILMI(Integrated Local Management Interface) -- MIB for broad band Interface in MGX82xx series products. -- -- December 2002, Subra Hegde -- -- Copyright (c) 2002 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** CISCO-WAN-BBIF-ILMI-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF AtmIlmiNetworkPrefix FROM ATM-TC-MIB bbIfCnf, bbIfCnt FROM BASIS-MIB ciscoWan FROM CISCOWAN-SMI; ciscoWanBbifIlmiMIB MODULE-IDENTITY LAST-UPDATED "200212200000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO " Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com" DESCRIPTION "The MIB module for ILMI configuration and ILMI statistics for broad band interface ports in PXM1 service module. PXM1 service module is supported in MGX82xx series products. The broadband interface referred to in this mib is for ATM logical ports." REVISION "200212200000Z" DESCRIPTION "Initial version of the MIB. The content of this MIB was originally available in CISCO-WAN-AXIPOP-MIB defined using SMIv1. The applicable objects from CISCO-WAN-AXIPOP-MIB are defined using SMIv2 in this MIB. Also the descriptions of some of the objects have been modified." ::= { ciscoWan 33 } bbIfCnfSigILMIGrp OBJECT IDENTIFIER ::= { bbIfCnf 2} bbIfCntSigILMIGrp OBJECT IDENTIFIER ::= { bbIfCnt 2} -- ********************************************************************** -- -- bbIfCnfSigILMI group -- Port configurable signalling parameters, -- when the logical interface is used as a UNI port -- -- ********************************************************************** bbIfCnfSigILMIGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF BbIfCnfSigILMIGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ILMI configuration parameters for a broadband interface." ::= { bbIfCnfSigILMIGrp 1 } bbIfCnfSigILMIGrpEntry OBJECT-TYPE SYNTAX BbIfCnfSigILMIGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry for a boradband interface used as a UNI port. Each entry contains ILMI configuration parameters and variables for a broadband interface." INDEX { bbIfSigPortNum } ::= { bbIfCnfSigILMIGrpTable 1 } BbIfCnfSigILMIGrpEntry ::= SEQUENCE { bbIfSigPortNum Integer32, bbIfIlmiEnable INTEGER, bbIfSignallingProtocolType INTEGER, bbIfSignallingVpi Integer32, bbIfSignallingVci Integer32, bbIfAddrPrefix AtmIlmiNetworkPrefix, bbIfCustomerId Integer32, bbIfProtocolRevNo Integer32, bbIfIlmiTrapEnable INTEGER, bbIfMinTrapInterval Integer32, bbIfKeepAlivePollingEnable INTEGER, bbIfErrorThresholdN491 Integer32, bbIfEventThresholdN492 Integer32, bbIfPollingIntervalT491 INTEGER, bbIfMinEnquiryIntervalT493 Integer32, bbIfAddrRegEnable INTEGER } bbIfSigPortNum OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object refers to the broadband interface. The value for this object is same as value specified in bbIfNum object from bbIfCnfGrpTable." REFERENCE "CISCO-WAN-BBIF-PORT-MIB" ::= { bbIfCnfSigILMIGrpEntry 1 } bbIfIlmiEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The logical interface is a generic entity, it can be used as either a virtual trunk, or user port with UNI support. This variable is provided to enable/disable ILMI. ILMI should only be enabled on 'user ports' and not on 'virtual trunks' 1 - disable 2 - enable" DEFVAL { disable } ::= { bbIfCnfSigILMIGrpEntry 2} bbIfSignallingProtocolType OBJECT-TYPE SYNTAX INTEGER { other (1), noSignalling (2), iLMI (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This will set the signalling protocol other(1) : other noSignalling(2) : noSignalling iLMI(3) : ILMI" ::= { bbIfCnfSigILMIGrpEntry 3} bbIfSignallingVpi OBJECT-TYPE SYNTAX Integer32 (0..4095 ) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the VPI on which signalling cells received." ::= { bbIfCnfSigILMIGrpEntry 4} bbIfSignallingVci OBJECT-TYPE SYNTAX Integer32 (0..'ffff'h ) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the VPI on which signalling cells received." ::= { bbIfCnfSigILMIGrpEntry 5} bbIfAddrPrefix OBJECT-TYPE SYNTAX AtmIlmiNetworkPrefix MAX-ACCESS read-write STATUS current DESCRIPTION "Network Prefix for the ATM address." ::= { bbIfCnfSigILMIGrpEntry 6} bbIfCustomerId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This represents the customer Id." ::= { bbIfCnfSigILMIGrpEntry 7} bbIfProtocolRevNo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object represents the protocol revision number." ::= { bbIfCnfSigILMIGrpEntry 8} bbIfIlmiTrapEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used for enabling/disabling the sending of ILMI traps." ::= { bbIfCnfSigILMIGrpEntry 9} bbIfMinTrapInterval OBJECT-TYPE SYNTAX Integer32 (1..10) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum throttling period of notification generation. The notificaton events should be suppressed by the agent until the current throttling period expires." ::= { bbIfCnfSigILMIGrpEntry 10} bbIfKeepAlivePollingEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable Keep Alive Polling." ::= { bbIfCnfSigILMIGrpEntry 11} bbIfErrorThresholdN491 OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies Error Threshold (N491) value. The number of keep alive polls that must fail within a window of N491 polls, before the port is placed in the failed state. This attribute is applicable only when bbIfSignallingProtocolType set to iLMI(3)." ::= { bbIfCnfSigILMIGrpEntry 12} bbIfEventThresholdN492 OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies Error Threshold (N492) value. The number of keep alive polls that must fail within a window of N492 polls, before the port is placed in the failed state. This attribute is applicable only when bbIfSignallingProtocolType set to iLMI(3)." ::= { bbIfCnfSigILMIGrpEntry 13} bbIfPollingIntervalT491 OBJECT-TYPE SYNTAX INTEGER { v1(5), v2(10), v3(15), v4(20), v5(25), v6(30), v7(35), v8(40), v9(45), v10(50), v11(55), v12(60) } UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies Polling Interval (T491) value. The T491 value is the number of seconds between each keep alive poll transmitted by port. This attribute is applicable only when bbIfSignallingProtocolType set to iLMI(3)." ::= { bbIfCnfSigILMIGrpEntry 14} bbIfMinEnquiryIntervalT493 OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies minimum Enquiry Interval(T493) value. The T493 value is the number of seconds between each keep alive poll transmitted by port. This attribute is applicable only when bbIfSignallingProtocolType set to iLMI(3)." ::= { bbIfCnfSigILMIGrpEntry 15} bbIfAddrRegEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable ILMI Address Registration." DEFVAL { disable } ::= { bbIfCnfSigILMIGrpEntry 16} -- ********************************************************************** -- -- bbIfCntSigILMI group -- ILMI and signalling counts, when the logical interface is -- used as a UNI port -- -- ********************************************************************** bbIfCntSigILMIGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF BbIfCntSigILMIGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains statistics related to ILMI." ::= { bbIfCntSigILMIGrp 1 } bbIfCntSigILMIGrpEntry OBJECT-TYPE SYNTAX BbIfCntSigILMIGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry for a boradband interface used as a UNI port." INDEX { sigCntBbIfNum } ::= { bbIfCntSigILMIGrpTable 1 } BbIfCntSigILMIGrpEntry ::= SEQUENCE { sigCntBbIfNum Integer32, bbIfSnmpPduReceived Counter32, bbIfGetRequestReceived Counter32, bbIfGetNextRequestReceived Counter32, bbIfSetRequestReceived Counter32, bbIfTrapReceived Counter32, bbIfGetResponseReceived Counter32, bbIfGetResponseTransmitted Counter32, bbIfGetRequestTransmitted Counter32, bbIfTrapTransmitted Counter32, bbIfInvalidPDUReceived Counter32, bbIfAsn1ParseError Counter32, bbIfNoSuchNameError Counter32, bbIfTooBigError Counter32, bbIfSigCntClrButton INTEGER } sigCntBbIfNum OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "This object refers to the broadband interface. The value for this object is same as value specified in bbIfSigPortNum object from bbIfCnfSigILMIGrpTable." ::= { bbIfCntSigILMIGrpEntry 1} bbIfSnmpPduReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of snmp packets received on this logical interface." ::= { bbIfCntSigILMIGrpEntry 2 } bbIfGetRequestReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of get request messages received." ::= { bbIfCntSigILMIGrpEntry 3 } bbIfGetNextRequestReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of get-next messages received." ::= { bbIfCntSigILMIGrpEntry 4 } bbIfSetRequestReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of set messages received." ::= { bbIfCntSigILMIGrpEntry 5 } bbIfTrapReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of traps received." ::= { bbIfCntSigILMIGrpEntry 6 } bbIfGetResponseReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Keep Alive response messages received." ::= { bbIfCntSigILMIGrpEntry 7 } bbIfGetResponseTransmitted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of response messages transmitted." ::= { bbIfCntSigILMIGrpEntry 8 } bbIfGetRequestTransmitted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Keep Alive get request messages transmitted." ::= { bbIfCntSigILMIGrpEntry 9 } bbIfTrapTransmitted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of trap messages transmitted." ::= { bbIfCntSigILMIGrpEntry 10 } bbIfInvalidPDUReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid PDUs received." ::= { bbIfCntSigILMIGrpEntry 11 } bbIfAsn1ParseError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of parse errors on ASN.1." ::= { bbIfCntSigILMIGrpEntry 12 } bbIfNoSuchNameError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of errors for name not present." ::= { bbIfCntSigILMIGrpEntry 13 } bbIfTooBigError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of messages received with len > 484." ::= { bbIfCntSigILMIGrpEntry 14 } bbIfSigCntClrButton OBJECT-TYPE SYNTAX INTEGER { noAction (1), resetCounters (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Writing a value of 2 resets all the counters from bbIfCntSigILMIGrpTable." ::= { bbIfCntSigILMIGrpEntry 15 } -- conformance information cwbIlmiMIBConformance OBJECT IDENTIFIER ::= { ciscoWanBbifIlmiMIB 2 } cwbIlmiMIBGroups OBJECT IDENTIFIER ::= { cwbIlmiMIBConformance 1 } cwbIlmiMIBCompliances OBJECT IDENTIFIER ::= { cwbIlmiMIBConformance 2 } -- compliance statements cwbIlmiCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for objects related to SRM MIB." MODULE -- this module MANDATORY-GROUPS { cwbIlmiConfGroup, cwbIlmiStatsGroup } OBJECT bbIfCustomerId MIN-ACCESS read-only DESCRIPTION "For INS(Intelligent Network Server) read-write needs to be supported." OBJECT bbIfProtocolRevNo MIN-ACCESS read-only DESCRIPTION "For INS(Intelligent Network Server) read-write needs to be supported." ::= { cwbIlmiMIBCompliances 1 } cwbIlmiConfGroup OBJECT-GROUP OBJECTS { bbIfSigPortNum, bbIfIlmiEnable, bbIfSignallingProtocolType, bbIfSignallingVpi, bbIfSignallingVci, bbIfAddrPrefix, bbIfCustomerId, bbIfProtocolRevNo, bbIfIlmiTrapEnable, bbIfMinTrapInterval, bbIfKeepAlivePollingEnable, bbIfErrorThresholdN491, bbIfEventThresholdN492, bbIfPollingIntervalT491, bbIfMinEnquiryIntervalT493, bbIfAddrRegEnable } STATUS current DESCRIPTION "The collection of objects which are used for configuring ILMI on broad band interface ports." ::= { cwbIlmiMIBGroups 1 } cwbIlmiStatsGroup OBJECT-GROUP OBJECTS { sigCntBbIfNum, bbIfSnmpPduReceived, bbIfGetRequestReceived, bbIfGetNextRequestReceived, bbIfSetRequestReceived, bbIfTrapReceived, bbIfGetResponseReceived, bbIfGetResponseTransmitted, bbIfGetRequestTransmitted, bbIfTrapTransmitted, bbIfInvalidPDUReceived, bbIfAsn1ParseError, bbIfNoSuchNameError, bbIfTooBigError, bbIfSigCntClrButton } STATUS current DESCRIPTION "The collection of objects containing the ILMI statistics on broad band interface ports." ::= { cwbIlmiMIBGroups 2 } END