-- ***************************************************************** -- CISCO-MODEM-MGMT-MIB.my: Cisco Modem Management MIB file -- -- January 1996, Viet Nguyen -- -- Copyright (c) 1996-1998, 1999, 2000, 2001, 2005 by cisco Systems, Inc. -- All rights reserved. -- -- ***************************************************************** CISCO-MODEM-MGMT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Integer32, Gauge32, Counter32, TimeTicks, Unsigned32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TruthValue, DisplayString FROM SNMPv2-TC InterfaceIndex FROM IF-MIB ciscoMgmt FROM CISCO-SMI; ciscoModemMgmtMIB MODULE-IDENTITY LAST-UPDATED "200512060000Z" -- Dec 06,2005 ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO " Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com" DESCRIPTION "This MIB module provides modem call related data for tracking the progress and status of a call." REVISION "200512060000Z" DESCRIPTION "Imported Unsigned32 from SNMPv2-SMI instead of CISCO-TC" REVISION "200112011200Z" -- Dec 01,2001 12:00:00 GMT DESCRIPTION "Added one more comment for cmTXAnalogSignalLevel" REVISION "200110011200Z" DESCRIPTION "General cleanup" REVISION "200004010000Z" DESCRIPTION "Added cmStateNotification and cmStateNotifyEnable" REVISION "9812160000Z" DESCRIPTION "Added cmTotalCallDuration" REVISION "9806180000Z" DESCRIPTION "Added the new enum values for cmDisconnectReason" REVISION "9712220000Z" DESCRIPTION "Changed the modulation from v27 to v29." REVISION "9710130000Z" DESCRIPTION "Added new compliance statement for as5300 and c3600." REVISION "9707180000Z" DESCRIPTION "Added new MIB variables cmInitialTxLineConnections and cmInitialRxLineConnections" REVISION "9803090000Z" DESCRIPTION "Added the new enum values v90 and v27ter for cmModulationSchemeUsed." REVISION "9712160000Z" DESCRIPTION "Changed the modulation from v27 to v29." REVISION "9705010000Z" DESCRIPTION "Added objects: cmSystemModemsInUse cmSystemModemsAvailable cmSystemModemsUnavailable cmSystemModemsOffline cmSystemModemsDead" REVISION "9704290000Z" DESCRIPTION "Changed the modulation from v29 to v27." REVISION "9706110000Z" DESCRIPTION "DEFVAL update for cmSystemWatchdogTime,cmSystemStatusPollTime." REVISION "9703210000Z" DESCRIPTION "New enum values added for cmModulationSchemeUsed." REVISION "9703170000Z" DESCRIPTION "New enum values added for cmDisconnectReason." REVISION "9601110000Z" DESCRIPTION "Initial version of this MIB module." ::= { ciscoMgmt 47 } ciscoModemMgmtMIBObjects OBJECT IDENTIFIER ::= { ciscoModemMgmtMIB 1 } cmSystemInfo OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 1 } cmGroupInfo OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 2 } cmLineInfo OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 3 } cmNotificationConfig OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBObjects 4 } -- -- System Wide Modem Info Table -- cmSystemInstalledModem OBJECT-TYPE SYNTAX Gauge32 UNITS "modems" MAX-ACCESS read-only STATUS current DESCRIPTION "The actual number of modems that are currently installed within this system." ::= { cmSystemInfo 1 } cmSystemConfiguredGroup OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The actual number of modem groups that are currently configured within this system. Maximum value for this object is cmSystemInstalledModem." ::= { cmSystemInfo 2 } cmSystemWatchdogTime OBJECT-TYPE SYNTAX Integer32 UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "A passive software watchdog timer value will be used to recover a modem which enters into an unexpected state and hangs. When this watch dog timer times out, the modem associated Call Processing state will be set back to IDLE, all related TDM paths will be restored to default configurations, and all of call processing related actions will stop for the modem." DEFVAL { 6 } ::= { cmSystemInfo 3 } cmSystemStatusPollTime OBJECT-TYPE SYNTAX Integer32 (2..120) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The ideal time interval between modem status polling via the out of band management port." DEFVAL { 12 } ::= { cmSystemInfo 4 } cmSystemMaxRetries OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "A reply event is expected to be received for every message sent to the modem through the out of band management port. If an expected reply event is not received, the message will be sent to the modem again. This object specifies the maximum number of retries that should be executed." DEFVAL { 3 } ::= { cmSystemInfo 5 } cmSystemModemsInUse OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of modems in the system that are in the following states: connected, offHook, loopback, or downloadFirmware." ::= { cmSystemInfo 6 } cmSystemModemsAvailable OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of modems in the system that are onHook. That is, they are ready to accept a call." ::= { cmSystemInfo 7 } cmSystemModemsUnavailable OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of modems in the system that cannot accept calls. They are in a state other than onHook." ::= { cmSystemInfo 8 } cmSystemModemsOffline OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of modems in the system, which have been held administratively offline" ::= { cmSystemInfo 9 } cmSystemModemsDead OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of modems in the system with the state bad or downloadFirmwareFailed." ::= { cmSystemInfo 10 } -- -- Modem Group General Info Table -- cmGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF CmGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of descriptive and status information about the groups of modems." ::= { cmGroupInfo 1 } cmGroupEntry OBJECT-TYPE SYNTAX CmGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a single group of modems." INDEX { cmGroupIndex } ::= { cmGroupTable 1 } CmGroupEntry ::= SEQUENCE { cmGroupIndex Unsigned32, cmGroupTotalDevices Integer32 } cmGroupIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the group containing the modems for which this entry contains information." ::= { cmGroupEntry 1 } cmGroupTotalDevices OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of modem devices which are configured in the group." ::= { cmGroupEntry 2 } -- -- Table for Modem Group Members -- cmGroupMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF CmGroupMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of information about the modem members in modem groups." ::= { cmGroupInfo 2 } cmGroupMemberEntry OBJECT-TYPE SYNTAX CmGroupMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about modem members in a group. The modem groups are currently created when an associated Async interface groups are configured via CLI command 'interface group-async' and not via SNMP." INDEX { cmGroupIndex, cmSlotIndex, cmPortIndex } ::= { cmGroupMemberTable 1 } CmGroupMemberEntry ::= SEQUENCE { cmSlotIndex Unsigned32, cmPortIndex Unsigned32 } cmSlotIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The modem feature card slot number in the group." ::= { cmGroupMemberEntry 1 } cmPortIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modem port number of a modem feature card in the group." ::= { cmGroupMemberEntry 2 } -- -- Modem Line Status Info Table -- cmLineStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF CmLineStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects that describe the status of the modem." ::= { cmLineInfo 1 } cmLineStatusEntry OBJECT-TYPE SYNTAX CmLineStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing status information about a single modem." INDEX { cmSlotIndex, cmPortIndex } ::= { cmLineStatusTable 1 } CmLineStatusEntry ::= SEQUENCE { cmInterface InterfaceIndex, cmGroup Integer32, cmManufacturerID DisplayString, cmProductDetails DisplayString, cmManageable TruthValue, cmState INTEGER, cmCallDirection INTEGER, cmDisconnectReason INTEGER, cmCallDuration TimeTicks, cmCallPhoneNumber DisplayString, cmCallerID DisplayString, cmModulationSchemeUsed INTEGER, cmProtocolUsed INTEGER, cmTXRate Gauge32, cmRXRate Gauge32, cmTXAnalogSignalLevel Integer32, cmRXAnalogSignalLevel Integer32 } cmInterface OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The interface that this modem is connected." ::= { cmLineStatusEntry 1 } cmGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modem group number that the modem may be in." ::= { cmLineStatusEntry 2 } cmManufacturerID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..79)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description to identify the modem, including the manufacturer's name and type of modem." ::= { cmLineStatusEntry 3 } cmProductDetails OBJECT-TYPE SYNTAX DisplayString (SIZE (0..79)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the modem, including hardware revision number, firmware revision number, feature set and optionally, its serial number." ::= { cmLineStatusEntry 4 } cmManageable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The Manageable modem allows to be accessed through the out of band management port in which the modem statistic data can be retrieved, and the Direct Connect session can be used to provide the test and debugging ability. This object specifies whether this modem is a Manageable modem." ::= { cmLineStatusEntry 5 } cmState OBJECT-TYPE SYNTAX INTEGER { unknown(1), onHook(2), offHook(3), connected(4), busiedOut(5), disabled(6), bad(7), loopback(8), downloadFirmware(9), downloadFirmwareFailed(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current state of modem. The meaning of each state code is explained below: unknown: the current state of the modem is unknown. onHook: the condition similar to hanging up a telephone receiver. The call cannot enter a connected state when the modem is onHook. offHook: The condition similar to picking up a telephone receiver to dial or answer a call. connected: The modem is in a state when it can transmit or receive data over the communications line. busiedOut: The modem is busied out (i.e. taken out of service) and cannot make outgoing calls or receive incoming calls. disabled: The modem is in a reset state and non-functional. This state can be set and clear via cmHoldReset. bad: The modem is suspected or proven to be bad. The operator can take the modem out of service and mark the modem as 'bad' via cmBad. loopback: The modem is in a state where it is currently running back-to-back loopback testing. downloadFirmware: The modem is in a state where it is currently downloading the firmware. downloadFirmwareFailed: The modem is not operational because the downloading of firmware to it has failed." ::= { cmLineStatusEntry 6 } cmCallDirection OBJECT-TYPE SYNTAX INTEGER { incoming(1), outgoing(2), none(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The modem can be used either as an incoming call or outgoing call. This object specifies the direction of the current or previous call." ::= { cmLineStatusEntry 7 } cmDisconnectReason OBJECT-TYPE SYNTAX INTEGER { unknown(1), lostCarrier(2), noCarrier(3), noDialTone(4), busy(5), modemWatchdogTimeout(6), dtrDrop(7), userHangup(8), compressionProblem(9), retrainFailure(10), remoteLinkDisconnect(11), abort(12), inactivityTimeout(13), dialStringError(14), linkFailure(15), modulationError(16), dialTimeout(17), remoteHangup(18), mnp10ProtocolError(19), lapmProtocolError(20), faxClass2Error(21), trainupFailure(22), fallbackTerminate(23), excessiveEC(24), hostDrop(25), terminate(26), autoLogonError(27), ccpNotSeen(28), callbackFailed(29), blacklist(30), lapmTimeout(31), reliableLinkTxTimeout(32), dspAccessFailure(33), cdOffTimeout(34), codewordSizeMismatch(35), dspDownloadFailure(36), modemDrNone(37), modemDrSoftwareReset(38), modemDrEcTerminated(39), modemDrBadMnp5Rxdata(40), modemDrBadV42bisRxdata(41), modemDrBadCopState(42), modemDrAth(43), modemDrAborted(44), modemDrConnectTimeout(45), modemDrResetDsp(46), modemDrNoCarrier(47), modemDrNoAbtDetected(48), modemDrTrainupFailure(49), modemDrRetrainLimit(50), modemDrAbtEndFailure(51), modemDrNoLr(52), modemDrLrParam1(53), modemDrLrIncompat(54), modemDrRetransmitLimit(55), modemDrInactivity(56), modemDrProtocolError(57), modemDrFallbackTerminate(58), modemDrNoXid(59), modemDrXidIncompat(60), modemDrDisc(61), modemDrDm(62), modemDrBadNr(63), modemDrSabmeOnline(64), modemDrXidOnline(65), modemDrLrOnline(66), modemDrBadCmnd(67), modemDrFrmrBadCmnd(68), modemDrFrmrData(69), modemDrFrmrLength(70), modemDrFrmrBadNr(71), modemDrLdNoLr(72), modemDrLdLrParam1(73), modemDrLdLrIncompat(74), modemDrLdRetransLimit(75), modemDrLdInactivity(76), modemDrLdProtocol(77), modemDrLdUser(78), modemDrHostNonspecific(79), modemDrHostBusy(80), modemDrHostNoAnswer(81), modemDrHostDtr(82), modemDrHostAth(83), modemDrHostNoDialtone(84), modemDrHostNoCarrier(85), modemDrHostAck(86), modemDrMohClrd(87), modemDrMohTimeout(88), modemDrCotAck(89), modemDrCotNak1(90), modemDrCotNak2(91), modemDrCotOff(92), modemDrCotTimeout(93), modemDrDcIllegalCodewordStepup(94), modemDrDcIllegalTokenEmptyNode(95), modemDrDcIllegalTokenTooLarge(96), modemDrDcReservedCommand(97), modemDrDcIllegalCharacterSizeStepup(98), modemDrDcRxDictionaryFull(99), modemDrDcRxHistoryFull(100), modemDrDcRxStringSizeExceeded(101), modemDrDcNegotiationError(102), modemDrDcCompressionError(103) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the reason that the last connection or call attempt disconnected. The meaning of each reason code is explained below: unknown: the failure reason is unknown or there has been no previous call. lostCarrier: the call was disconnected because the loss of carrier. noCarrier: the dial out attempt has failed because the modem detects no carrier. noDialTone: the dial out attempt has failed because the modem failed to detect a dial tone. busy: the call attempt failed because the modem detected a busy signal. modemWatchdogTimeout: the modem internal watchdog timer has expired. dtrDrop: DTR has been turned off while the modem is to disconnect on DTR drop. userHangup: normal disconnect where the user hangs up call. compressionProblem: the call is disconnected due to a problem detected during compression in the modem. retrainFailure: the modem did not successfully train and reach data mode on the previous connections. remoteLinkDisconnect: the remote link disconnected the connection. abort: the call was aborted. inactivityTimeout: the modem automatically hangs up because data is not sent or received within the inactivity time out. dialStringError: the dialed phone number is invalid. linkFailure: the modem detects a link failure. modulationError: the modem detects a modulation error. dialTimeout: the modem times out while attempting to dial. remoteHangup: the remote side hangs up the connection. mnp10ProtocolError: MNP10 Protocol Error. lapmProtocolError: LAPM Protocol Error. faxClass2Error: Fax Class 2 Error. trainupFailure: failure to trainup with a remote peer. fallbackTerminate: User has EC fallback set to disconnect. excessiveEC: Link loss due to excessive EC retransmissions. EC packet transmit limit exceeded. hostDrop: Host initiated link drop. terminate: Lost Carrier Microcom HDMS product relating to password security issues. autoLogonError: An autologon sequence did not complete successfully. ccpNotSeen: The Credit Card Prompt was not detected. callbackFailed: Applies to leased line connection. If after a switched line dialback due to a leased line connection failure, the switched line connection also fails and a connection can still not be made on the leased line, a disconnect occurs with this reason set. blacklist: In coutries that support blacklisting, an attempt was made to go off hook with a null dial string (ATD). lapmTimeout: Timed out waiting for a reply from remote. reliableLinkTxTimeout: Have not received the link acknowledgement in the first 30 seconds of the connection. dspAccessFailure: Timed out trying to access the DSP chip. cdOffTimeout: Timed out waiting for carrier to return after a retrain or rate renegotiation. codewordSizeMismatch: The codeword size are mismatched. dspDownloadFailure: Error during the DSP code download. The time taken to recover and repeat the download would take too long to complete the handshake." ::= { cmLineStatusEntry 8 } cmCallDuration OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the call duration of the current or previous call." ::= { cmLineStatusEntry 9 } cmCallPhoneNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The dialed outgoing telephone number of the current or previous call." ::= { cmLineStatusEntry 10 } cmCallerID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The incoming caller identification of the current or previous call if this entry is not in the connected state." ::= { cmLineStatusEntry 11 } cmModulationSchemeUsed OBJECT-TYPE SYNTAX INTEGER { unknown(1), bell103a(2), bell212a(3), v21(4), v22(5), v22bis(6), v32(7), v32bis(8), vfc(9), v34(10), v17(11), v29(12), v33(13), k56flex(14), v23(15), v32terbo(16), v34plus(17), v90(18), v27ter(19), v110(20), piafs(21) } MAX-ACCESS read-only STATUS current DESCRIPTION "The modem modulation scheme used in the current or previous call. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatusEntry 12 } cmProtocolUsed OBJECT-TYPE SYNTAX INTEGER { normal(1), direct(2), reliableMNP(3), reliableLAPM(4), syncMode(5), asyncMode(6), ara10(7), ara20(8), unknown(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The modem protocol used in the current or previous call. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatusEntry 13 } cmTXRate OBJECT-TYPE SYNTAX Gauge32 UNITS "bits/second" MAX-ACCESS read-only STATUS current DESCRIPTION "The speed of modem transmit rate of the current or previous call in bits per second. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatusEntry 14 } cmRXRate OBJECT-TYPE SYNTAX Gauge32 UNITS "bits/second" MAX-ACCESS read-only STATUS current DESCRIPTION "The speed of modem receive rate of the current or previous call in bits per second. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatusEntry 15 } cmTXAnalogSignalLevel OBJECT-TYPE SYNTAX Integer32 (-43..-9 | 0) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The modem transmit analog signal level in the current or previous call. The unit used is in dBm. This object is valid for modems that have cmManageable set to true(1) otherwise 0 will be returned." ::= { cmLineStatusEntry 16 } cmRXAnalogSignalLevel OBJECT-TYPE SYNTAX Integer32 (-128..-1 | 0) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The modem transmit analog signal level in the current or previous call. The unit used is in dBm. This object is valid for modems that have cmManageable set to true(1) otherwise 0 will be returned." ::= { cmLineStatusEntry 17 } -- -- Modem Line Configuration Table -- cmLineConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CmLineConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects that describe some of the configuration info of the modem." ::= { cmLineInfo 2 } cmLineConfigEntry OBJECT-TYPE SYNTAX CmLineConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing configuration information about a single modem." AUGMENTS { cmLineStatusEntry } ::= { cmLineConfigTable 1 } CmLineConfigEntry ::= SEQUENCE { cmATModePermit TruthValue, cmStatusPolling TruthValue, cmBusyOutRequest TruthValue, cmShutdown TruthValue, cmHoldReset TruthValue, cmBad TruthValue } cmATModePermit OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Direct Connect session is used for test and debugging purpose by using the modem AT commands through the out of band management port when cmManageable is true. This object specifies whether the Direct Connect session is permitted to be used at this modem. If cmManageable is true(1), Direct Connect session via the out of band port is allowed and false(2) indicates that it isn't allowed for the modem." DEFVAL { true } ::= { cmLineConfigEntry 1 } cmStatusPolling OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Modem status and events can be polled through the out of band management port when the cmManageable is true. This object specifies whether this status polling feature is enabled at this modem. If cmManageable is true(1), status polling will occur for the modem and false(2) indicates that no status polling will occur." DEFVAL { true } ::= { cmLineConfigEntry 2 } cmBusyOutRequest OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to put modem out of service, i.e. modem cannot make calls or answer calls. If the modem to be busyout is handling a call, the busyout action will be taken after the current call is disconnected. After modem is busyout, the following commands can be applied to those modems - reset, bad modem, download modem firmware, etc. This is called nice or graceful busyout. The value of true(1) indicates the busyOut request has been issued to the modem, but the busyout could be pending. The management entity needs to query the cmState to see if the modem is successfully busied out. The value of false(2) indicates the modem is not given the busyOut command." DEFVAL { false } ::= { cmLineConfigEntry 3 } cmShutdown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to put modem out of service, i.e. modem cannot make calls or answer calls. This is a hard busyout command to bring the modem out of service immediately without waiting for the call to be ended normally. After modem is shutdown, the following commands can be applied to those modems - reset, bad modem, download modem firmware, etc. The value of true(1) indicates the hard busyout has been issued to the modem. The value of false(2) indicates the modem has not been hard busyout." DEFVAL { false } ::= { cmLineConfigEntry 4 } cmHoldReset OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A command hold-reset will put the state of modem into reset mode until an inverse command to bring modem out of RESET mode. During the period of reset mode, this modem can not be used and is non-functional. This object is only valid when cmState is onHook, busiedOut, or disabled. The value of true(1) attempts to put the modem in reset mode, and the value of false(2) takes the modem out of reset. This object is not applicable for Mica modems." DEFVAL { false } ::= { cmLineConfigEntry 5 } cmBad OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object can hold modem out of service and marks the modem as suspected or proven to be bad. During the router start-up initialization sequence, modem back-to-back tests will test modems and mark those modems failing tests as bad modems. The management entity also can use this command to lock out the suspicious modem or unlock the modem to do further debugging or test. This command will be used accompanied with cmholdReset command to put modem out of service. This command doesn't do the reset. For a normally good modem, it can start handling calls after it exits from modem reset mode. For a bad modem, it cannot start handling calls after it exits from modem reset mode. The manager needs to take modem out of bad modem mode in order to handle calls. This object is only valid when cmState is onHook or busiedOut. The value of true(1) indicates the modem is suspected to be bad and its state is set to bad. The value of false(2) indicates the modem has not been suspected to be bad or has been re-marked as good." DEFVAL { false } ::= { cmLineConfigEntry 6 } -- -- Modem Line Statistics Table -- cmLineStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF CmLineStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects that describe the status of the modem." ::= { cmLineInfo 3 } cmLineStatisticsEntry OBJECT-TYPE SYNTAX CmLineStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing status information about a single modem." AUGMENTS { cmLineStatusEntry } ::= { cmLineStatisticsTable 1 } CmLineStatisticsEntry ::= SEQUENCE { cmRingNoAnswers Counter32, cmIncomingConnectionFailures Counter32, cmIncomingConnectionCompletions Counter32, cmOutgoingConnectionFailures Counter32, cmOutgoingConnectionCompletions Counter32, cmFailedDialAttempts Counter32, cmNoDialTones Counter32, cmDialTimeouts Counter32, cmWatchdogTimeouts Counter32, cm2400OrLessConnections Counter32, -- deprecated cm2400To14400Connections Counter32, -- deprecated cmGreaterThan14400Connections Counter32, -- deprecated cmNoCarriers Counter32, cmLinkFailures Counter32, cmProtocolErrors Counter32, cmPollingTimeouts Counter32, cmTotalCallDuration Counter32 } cmRingNoAnswers OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter to count the calls that ringing was detected but the call was not answered at this modem." ::= { cmLineStatisticsEntry 1 } cmIncomingConnectionFailures OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of incoming connection requests that this modem answered in which it could not train with the other DCE. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 2 } cmIncomingConnectionCompletions OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of incoming connection requests that this modem answered and successfully trained with the other DCE. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 3 } cmOutgoingConnectionFailures OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of outgoing calls from this modem which successfully went off hook and dialed, in which it could not train with the other DCE. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 4 } cmOutgoingConnectionCompletions OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of outgoing calls from this modem which resulted in successfully training with the other DCE.This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 5 } cmFailedDialAttempts OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of call attempts that failed because the modem didn't go off hook, or there was no dial tone." ::= { cmLineStatisticsEntry 6 } cmNoDialTones OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of times the dial tone expected but not received. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 7 } cmDialTimeouts OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of times the dial time-out occurred. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 8 } cmWatchdogTimeouts OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the Call Processing watchdog timer has expired." ::= { cmLineStatisticsEntry 9 } cm2400OrLessConnections OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of connections initially established at a modulation speed of 2400 bits per second or less. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 10 } cm2400To14400Connections OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of connections initially established at a modulation speed of greater than 2400 bits per second and less than 14400 bits per second. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 11 } cmGreaterThan14400Connections OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of connections initially established at a modulation speed of greater than 14400 bits per second. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 12 } cmNoCarriers OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of times that the disconnect reason is no carrier. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 13 } cmLinkFailures OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of times that the disconnect reason is link failure. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 14 } cmProtocolErrors OBJECT-TYPE SYNTAX Counter32 UNITS "errors" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of times that the out of band protocol error occurred. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 15 } cmPollingTimeouts OBJECT-TYPE SYNTAX Counter32 UNITS "errors" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates the number of times that the out of band protocol time-out error occurred. This object is valid only for modems which have cmManageable to be true." ::= { cmLineStatisticsEntry 16 } cmTotalCallDuration OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "A counter that indicates total call duration on the modem. This includes the duration of all previous calls." ::= { cmLineStatisticsEntry 17 } -- -- Modem Line Speed Statistics Table -- cmLineSpeedStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF CmLineSpeedStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects that describe the intial modem line speeds and connections" ::= { cmLineInfo 4 } cmLineSpeedStatisticsEntry OBJECT-TYPE SYNTAX CmLineSpeedStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing initial speed and connection information about a single modem." INDEX { cmSlotIndex, cmPortIndex, cmInitialLineSpeed } ::= { cmLineSpeedStatisticsTable 1} CmLineSpeedStatisticsEntry ::= SEQUENCE { cmInitialLineSpeed Unsigned32, cmInitialLineConnections Counter32, -- deprecated cmInitialTxLineConnections Counter32, cmInitialRxLineConnections Counter32 } cmInitialLineSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A discrete initial speed at which the given line may operate" ::= { cmLineSpeedStatisticsEntry 1 } cmInitialLineConnections OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS deprecated -- superceded by cmInitialTxLineConnections DESCRIPTION "The number of connections initially established at a given modulation speed. An instance of this object will be only present for those speeds where one or more connections have occurred" ::= { cmLineSpeedStatisticsEntry 2 } cmInitialTxLineConnections OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Transmit connections initially established at a given modulation speed. An instance of this object will be only present for those speeds where one or more connections have occurred" ::= { cmLineSpeedStatisticsEntry 3 } cmInitialRxLineConnections OBJECT-TYPE SYNTAX Counter32 UNITS "calls" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Receive connections initially established at a given modulation speed. An instance of this object will be only present for those speeds where one or more connections have occurred" ::= { cmLineSpeedStatisticsEntry 4 } -- -- Notification Configuration -- cmStateNotifyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This variable controls generation of the cmStateNotification. When this variable is 'true(1)', generation of cmStateNotification is enabled. When this variable is 'false(2)', generation of cmStateNotification is disabled. The default value is 'false(2)'. " ::= { cmNotificationConfig 1 } -- ****************************************************************** -- Notifications -- ****************************************************************** cmMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoModemMgmtMIB 2 } cmMIBNotifications OBJECT IDENTIFIER ::= { cmMIBNotificationPrefix 0 } cmStateNotification NOTIFICATION-TYPE OBJECTS { cmState } STATUS current DESCRIPTION "A modem port state change notification is generated whenever the port transitions to a state where it is offline due to a failure or administrative action. The values of cmState which will trigger this notification are: busiedOut(5) - Administratively out of service disabled(6) - Administratively out of service bad(7) - Internally detected failure or administrative action loopback(8) - Testing downloadFirmware(9) - Administrative action downloadFirmwareFailed(10) - Internally detected failure " ::= { cmMIBNotifications 1 } -- -- conformance information -- ciscoModemMgmtMIBConformance OBJECT IDENTIFIER ::= { ciscoModemMgmtMIB 3 } ciscoModemMgmtMIBCompliances OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBConformance 1 } ciscoModemMgmtMIBGroups OBJECT IDENTIFIER ::= { ciscoModemMgmtMIBConformance 2 } -- compliance statements ciscoModemMgmtMIBCompliance MODULE-COMPLIANCE STATUS obsolete -- superseded by ciscoModemMgmtMIBComplianceRev1 DESCRIPTION "The compliance statement for entities which implement the cisco Modem Management MIB" MODULE -- this module MANDATORY-GROUPS { cmSystemInfoGroup, cmLineInfoGroup, cmGroupInfoGroup } GROUP cmManagedLineInfoGroup DESCRIPTION "This group is mandatory for all managed modems." ::= { ciscoModemMgmtMIBCompliances 1 } ciscoModemMgmtMIBComplianceRev1 MODULE-COMPLIANCE STATUS obsolete -- superseded by ciscoModemMgmtMIBComplianceRev2 DESCRIPTION "The compliance statement for entities which implement the cisco Modem Management MIB" MODULE -- this module MANDATORY-GROUPS { cmSystemInfoGroup, cmLineInfoGroup, cmGroupInfoGroup } GROUP cmManagedLineInfoGroup DESCRIPTION "This group is mandatory for all managed modems." GROUP cmLineSpeedInfoGroup DESCRIPTION "This group is mandatory for all managed modems." ::= { ciscoModemMgmtMIBCompliances 2 } ciscoModemMgmtMIBComplianceRev2 MODULE-COMPLIANCE STATUS obsolete -- superceded by ciscoModemMgmtMIBComplianceRev3 DESCRIPTION "The compliance statement for entities which implement the cisco Modem Management MIB" MODULE -- this module MANDATORY-GROUPS { cmSystemInfoGroupRev1, cmLineInfoGroup, cmGroupInfoGroup } GROUP cmManagedLineInfoGroup DESCRIPTION "This group is mandatory for all managed modems." GROUP cmLineSpeedInfoGroup DESCRIPTION "This group is mandatory for all managed modems." OBJECT cmSystemWatchdogTime MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { ciscoModemMgmtMIBCompliances 3 } ciscoModemMgmtMIBComplianceRev3 MODULE-COMPLIANCE STATUS obsolete -- superceded by ciscoModemMgmtMIBComplianceRev4 DESCRIPTION "The compliance statement for entities which implement the cisco Modem Management MIB" MODULE -- this module MANDATORY-GROUPS { cmSystemInfoGroupRev1, cmLineInfoGroup, cmGroupInfoGroup } GROUP cmManagedLineInfoGroup DESCRIPTION "This group is mandatory for all managed modems." GROUP cmLineSpeedInfoGroupRev1 DESCRIPTION "This group is mandatory for all managed modems." OBJECT cmSystemWatchdogTime MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { ciscoModemMgmtMIBCompliances 4 } ciscoModemMgmtMIBComplianceRev4 MODULE-COMPLIANCE STATUS obsolete -- superceded by ciscoModemMgmtMIBComplianceRev5 DESCRIPTION "The compliance statement for entities which implement the cisco Modem Management MIB" MODULE -- this module MANDATORY-GROUPS { cmGroupInfoGroup } GROUP cmLineSpeedInfoGroupRev1 DESCRIPTION "This group is mandatory only for managed modems." GROUP cmManagedLineInfoGroup DESCRIPTION "This group is mandatory only for managed modems. The following modifications may apply." OBJECT cmTXAnalogSignalLevel MIN-ACCESS not-accessible DESCRIPTION "Not supported for MICA or nextport modems." OBJECT cmPollingTimeouts MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmLineInfoGroup DESCRIPTION "With the following modifications, this group is mandatory for all modems." OBJECT cmATModePermit MIN-ACCESS not-accessible DESCRIPTION "AT Mode not required." OBJECT cmHoldReset MIN-ACCESS not-accessible DESCRIPTION "HoldReset not required." OBJECT cmStatusPolling MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmSystemInfoGroupRev1 DESCRIPTION "With the following modifications, this group is mandatory for all modems." OBJECT cmSystemWatchdogTime MIN-ACCESS read-only DESCRIPTION "Write access not supported." OBJECT cmSystemStatusPollTime MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." OBJECT cmSystemMaxRetries MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." ::= { ciscoModemMgmtMIBCompliances 5 } ciscoModemMgmtMIBComplianceRev5 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement the cisco Modem Management MIB" MODULE -- this module MANDATORY-GROUPS { cmGroupInfoGroup } GROUP cmLineSpeedInfoGroupRev1 DESCRIPTION "This group is mandatory only for managed modems." GROUP cmManagedLineInfoGroupRev1 DESCRIPTION "This group is mandatory only for managed modems. The following modifications may apply." OBJECT cmTXAnalogSignalLevel MIN-ACCESS not-accessible DESCRIPTION "Not supported for MICA or nextport modems." OBJECT cmPollingTimeouts MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmLineInfoGroup DESCRIPTION "With the following modifications, this group is mandatory for all modems." OBJECT cmATModePermit MIN-ACCESS not-accessible DESCRIPTION "AT Mode not required." OBJECT cmHoldReset MIN-ACCESS not-accessible DESCRIPTION "HoldReset not required." OBJECT cmStatusPolling MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmSystemInfoGroupRev1 DESCRIPTION "With the following modifications, this group is mandatory for all modems." OBJECT cmSystemWatchdogTime MIN-ACCESS read-only DESCRIPTION "Write access not supported." OBJECT cmSystemStatusPollTime MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." OBJECT cmSystemMaxRetries MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmNotificationConfigGroup DESCRIPTION "This group is mandatory only for systems supporting generation of modem notifications." GROUP cmNotificationGroup DESCRIPTION "This group is mandatory only for systems supporting generation of modem notifications." ::= { ciscoModemMgmtMIBCompliances 6 } ciscoModemMgmtMIBComplianceRev6 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the cisco Modem Management MIB" MODULE -- this module MANDATORY-GROUPS { cmGroupInfoGroup } GROUP cmLineSpeedInfoGroupRev2 DESCRIPTION "This group is mandatory only for managed modems." GROUP cmManagedLineInfoGroupRev2 DESCRIPTION "This group is mandatory only for managed modems. The following modifications may apply." OBJECT cmTXAnalogSignalLevel MIN-ACCESS not-accessible DESCRIPTION "Not supported for MICA or nextport modems." OBJECT cmPollingTimeouts MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmLineInfoGroup DESCRIPTION "With the following modifications, this group is mandatory for all modems." OBJECT cmATModePermit MIN-ACCESS not-accessible DESCRIPTION "AT Mode not required." OBJECT cmHoldReset MIN-ACCESS not-accessible DESCRIPTION "HoldReset not required." OBJECT cmStatusPolling MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmSystemInfoGroupRev1 DESCRIPTION "With the following modifications, this group is mandatory for all modems." OBJECT cmSystemWatchdogTime MIN-ACCESS read-only DESCRIPTION "Write access not supported." OBJECT cmSystemStatusPollTime MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." OBJECT cmSystemMaxRetries MIN-ACCESS not-accessible DESCRIPTION "Status Polling not required." GROUP cmNotificationConfigGroup DESCRIPTION "This group is mandatory only for systems supporting generation of modem notifications." GROUP cmNotificationGroup DESCRIPTION "This group is mandatory only for systems supporting generation of modem notifications." ::= { ciscoModemMgmtMIBCompliances 7 } -- units of conformance cmSystemInfoGroup OBJECT-GROUP OBJECTS { cmSystemInstalledModem, cmSystemConfiguredGroup, cmSystemWatchdogTime, cmSystemStatusPollTime, cmSystemMaxRetries } STATUS obsolete -- superseded by ciscoSystemInfoGroupRev1 DESCRIPTION "A collection of objects providing system configuration and status information." ::= { ciscoModemMgmtMIBGroups 1 } cmGroupInfoGroup OBJECT-GROUP OBJECTS { -- modem group info cmGroupTotalDevices, -- modem group members info cmPortIndex } STATUS current DESCRIPTION "A collection of objects providing modem configuration and statistics information for modem groups." ::= { ciscoModemMgmtMIBGroups 2 } cmLineInfoGroup OBJECT-GROUP OBJECTS { -- status cmInterface, cmGroup, cmManufacturerID, cmProductDetails, cmManageable, cmState, cmDisconnectReason, cmCallDirection, cmCallDuration, cmCallPhoneNumber, cmCallerID, -- configurations cmATModePermit, cmStatusPolling, cmBusyOutRequest, cmShutdown, cmHoldReset, cmBad, -- statistics cmRingNoAnswers, cmFailedDialAttempts, cmWatchdogTimeouts } STATUS current DESCRIPTION "A collection of objects providing modem configuration and statistics information for individual modem." ::= { ciscoModemMgmtMIBGroups 3 } cmManagedLineInfoGroup OBJECT-GROUP OBJECTS { cmModulationSchemeUsed, cmProtocolUsed, cmTXRate, cmRXRate, cmTXAnalogSignalLevel, cmRXAnalogSignalLevel, cmIncomingConnectionFailures, cmIncomingConnectionCompletions, cmOutgoingConnectionFailures, cmOutgoingConnectionCompletions, cmNoDialTones, cmDialTimeouts, cm2400OrLessConnections, -- deprecated cm2400To14400Connections, -- deprecated cmGreaterThan14400Connections, -- deprecated cmNoCarriers, cmLinkFailures, cmProtocolErrors, cmPollingTimeouts, cmTotalCallDuration } STATUS deprecated DESCRIPTION "A collection of objects providing modem configuration and statistics information for individual managed modems." ::= { ciscoModemMgmtMIBGroups 4 } cmLineSpeedInfoGroup OBJECT-GROUP OBJECTS { cmInitialLineConnections -- deprecated } STATUS obsolete -- superceded by cmLineSpeedInfogroupRev1 DESCRIPTION "A collection of objects providing modem configuration and statistics information for individual managed modems." ::= { ciscoModemMgmtMIBGroups 5 } cmSystemInfoGroupRev1 OBJECT-GROUP OBJECTS { cmSystemInstalledModem, cmSystemConfiguredGroup, cmSystemWatchdogTime, cmSystemStatusPollTime, cmSystemMaxRetries, cmSystemModemsInUse, cmSystemModemsAvailable, cmSystemModemsUnavailable, cmSystemModemsOffline, cmSystemModemsDead } STATUS current DESCRIPTION "A collection of objects providing system configuration and status information." ::= { ciscoModemMgmtMIBGroups 6 } cmLineSpeedInfoGroupRev1 OBJECT-GROUP OBJECTS { cmInitialLineConnections, -- deprecated cmInitialTxLineConnections, cmInitialRxLineConnections } STATUS deprecated DESCRIPTION "A collection of objects providing modem configuration and statistics information for individual managed modems." ::= { ciscoModemMgmtMIBGroups 7 } cmManagedLineInfoGroupRev1 OBJECT-GROUP OBJECTS { cmModulationSchemeUsed, cmProtocolUsed, cmTXRate, cmRXRate, cmTXAnalogSignalLevel, cmRXAnalogSignalLevel, cmIncomingConnectionFailures, cmIncomingConnectionCompletions, cmOutgoingConnectionFailures, cmOutgoingConnectionCompletions, cmNoDialTones, cmDialTimeouts, cm2400OrLessConnections, -- deprecated cm2400To14400Connections, -- deprecated cmGreaterThan14400Connections, -- deprecated cmNoCarriers, cmLinkFailures, cmProtocolErrors, cmPollingTimeouts, cmTotalCallDuration } STATUS deprecated DESCRIPTION "A collection of objects providing modem configuration and statistics information for individual managed modems." ::= { ciscoModemMgmtMIBGroups 8 } cmNotificationConfigGroup OBJECT-GROUP OBJECTS { cmStateNotifyEnable } STATUS current DESCRIPTION "Objects for configuring the notification behavior of this MIB. " ::= { ciscoModemMgmtMIBGroups 9 } cmNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { cmStateNotification } STATUS current DESCRIPTION "The collection of notifications used for monitoring modem status" ::= { ciscoModemMgmtMIBGroups 10 } cmLineSpeedInfoGroupRev2 OBJECT-GROUP OBJECTS { cmInitialTxLineConnections, cmInitialRxLineConnections } STATUS current DESCRIPTION "A collection of objects providing modem configuration and statistics information for individual managed modems." ::= { ciscoModemMgmtMIBGroups 11 } cmManagedLineInfoGroupRev2 OBJECT-GROUP OBJECTS { cmModulationSchemeUsed, cmProtocolUsed, cmTXRate, cmRXRate, cmTXAnalogSignalLevel, cmRXAnalogSignalLevel, cmIncomingConnectionFailures, cmIncomingConnectionCompletions, cmOutgoingConnectionFailures, cmOutgoingConnectionCompletions, cmNoDialTones, cmDialTimeouts, cmNoCarriers, cmLinkFailures, cmProtocolErrors, cmPollingTimeouts, cmTotalCallDuration } STATUS current DESCRIPTION "A collection of objects providing modem configuration and statistics information for individual managed modems." ::= { ciscoModemMgmtMIBGroups 12 } END