-- ***************************************************************** -- CISCO-ITP-GSP-MIB: Itp Signalling Point -- -- August 2002, John Linton, Shekhar Acharya -- -- Copyright (c) 2002-2003, 2005, 2008-2010 by Cisco Systems Inc. -- All rights reserved. -- ***************************************************************** CISCO-ITP-GSP-MIB DEFINITIONS ::= BEGIN IMPORTS Counter32, Integer32, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF SnmpAdminString FROM SNMP-FRAMEWORK-MIB InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB InterfaceIndexOrZero FROM IF-MIB RowStatus, TimeStamp, TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC CItpTcAclId, CItpTcCLLI, CItpTcDisplayPC, CItpTcInstanceNumber, CItpTcLinksetId, CItpTcNetworkName, CItpTcLinkSLC, CItpTcLinkType, CItpTcNetworkIndicator, CItpTcPointCode, CItpTcPointCodeType, CItpTcQos, CItpTcRouteTableName, CItpTcServiceIndicator FROM CISCO-ITP-TC-MIB ciscoMgmt FROM CISCO-SMI; ciscoGspMIB MODULE-IDENTITY LAST-UPDATED "201003050000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems, Inc Customer Service Postal: 170 W. Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-ss7@cisco.com" DESCRIPTION "The MIB for managing Signalling Points and its associated messages transported over Signalling System No. 7 (SS7) Network via Cisco IP Transfer Point. This MIB replaces the CISCO-ITP-SP-MIB and provide support multiple instances of a signalling point within same configuration. The Cisco IP Transfer Point (ITP) is a hardware and software solution that transports SS7 traffic using IP. Each ITP node provides function similar to SS7 Signalling point. The relevant ITU documents describing this technology is the ITU Q series, including ITU Q.700: Introduction to CCITT Signalling System No. 7 and ITU Q.701 Functional description of the message transfer part (MTP) of Signalling System No. 7. This MIB models the GSP as follows: Abbreviations: AERM - Alignment Error Rate Monitor CLLI - Common-Language Location Identification DPC - Destination Point Code GSP - Gateway Signalling Point HSL - High Speed Link (ATM based) LLSC - link set control LSAC - Signalling link activity control LSDA - Signalling data link allocation LSLA - Signalling link activation LSLD - Signalling link deactivation LSLR - Signalling link restoration LSSU - Link Status Signal Unit LSTA - Signalling terminal allocation MTP - Message Transport Protocol MTP2 - Layer 2 of Message Transport Protocol MTP3 - Layer 3 of Message Transport Protocol NTT - The Japanese Nippon Telephone & Telegraph OPC - Originating Point Code PC - Point Code RTN - RouteTableName SCTP - Stream Transmission Protocol(RFC 2960) SIB - Status Indicator Busy SLT - Signalling Link Test SLTA - Signalling Link Test Acknowledgement SP - Signalling Point SS7 - System No. 7 (SS7) Network SUERM - Signal Unit Error Rate Monitor TCBC - Changeback control TCOC - Changeover control TCRC - Controlled rerouting control TFRC - Forced rerouting control TLAC - Link availability control TPRC - Signalling point restart control TRCC - Signalling route set congestion control TSFC - Signalling traffic flow control TSRC - Signalling routing control TTC - The Japanese Telecommunications Technology Committee WRR - Weighted round robin" REVISION "200912310000Z" DESCRIPTION "Added the cgspLinkRxCongestionState object into CgspLinkTableEntry and ciscoGspRxCongestionChange notification to notify state of cgspLinkRxCongestionState." REVISION "200909120000Z" DESCRIPTION "Added the opc value to the cgspInstSccpWrrOption textual convention." REVISION "200905250000Z" DESCRIPTION "Added the following objects into cgspInstanceTableEntry for GTT weighted loadshare. cgspInstSccpWrrOpcShift, cgspInstSccpWrrOption" REVISION "200805070000Z" DESCRIPTION "Added the following objects into CgspLinkTableEntry for additional Q752 related reporting. cgspLinkQ752T1E12, cgspLinkQ752T1E12Errors, cgspLinkQ752T2E11, cgspLinkQ752T2E17, cgspLinkQ752T2E19. Added linkRestored(34) and linkTestFailure(35) reason code to the cgspLinkReason object. Added the following textual convention: CgspDisplayInstanceUserPart. Added a new table cgspInstUPUTable with following objects: cgspMtp3SI, cgspInstSIUPUReceived, cgspInstSIUPUTransmitted, cgspInstUserPartDisplay. Added the following objects: cgspNotificationsInfo, cgspUPUNotifWindowTime. Added following new notifications: ciscoGspUPUReceived, ciscoGspUPUTransmitted. Added the following cgspNotificationsInfo objects: cgspUPUIntervalDuration, cgspIntervalUPUs." REVISION "200510210000Z" DESCRIPTION "Added new set of enums (from timerMtp2T01 to timerMtp2T07) to TC CgspTimerNumbers for MTP2 timers specified in ITU Q.703." REVISION "200502240000Z" DESCRIPTION "Added new ciscoGspIsolation notification to indicate when MTP3 node becomes isolated." REVISION "200307160000Z" DESCRIPTION "Additional reason codes to the cgspLinkReason object and updated CgspSS7Variant textual convention to support NTT and TTC Japanese variants. Also, update REFERENCE clauses to indicate support for appropriate ANSI standard." REVISION "200303030000Z" DESCRIPTION "Initial version of this MIB module." ::= { ciscoMgmt 336 } -- Top-level structure of the MIB ciscoGspMIBNotifs OBJECT IDENTIFIER ::= { ciscoGspMIB 0 } ciscoGspMIBObjects OBJECT IDENTIFIER ::= { ciscoGspMIB 1 } ciscoGspMIBConform OBJECT IDENTIFIER ::= { ciscoGspMIB 2 } cgspScalars OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 1 } cgspProfile OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 2 } cgspInstance OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 3 } cgspPointCode OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 4 } cgspLinkset OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 5 } cgspLink OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 6 } cgspNotificationsEnable OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 7 } cgspNotificationsInfo OBJECT IDENTIFIER ::= { ciscoGspMIBObjects 8 } -- ************************************************************** -- * * -- * Textual Conventions * -- * * -- ************************************************************** CgspSequenceNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention defines all of the allowed values for a sequence of integers used by the SS7 protocol to transmit and acknowledge packets. The range is specified from 0 to maximum allowed value for extended sequence numbers. The actual range will depend on the type of link and the variant. The value will increase and then wrap to the zero value. The following are examples of valid sequences. 0..126,127,0.. 0..254,255,0.. 0..32766,32767,0.. 0..65534,65535,0.. Therefore, the sequence number will behave like a counter with range appropriate for the type of link." SYNTAX Unsigned32 (0..65535) CgspSampleInterval ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention defines the allowed values for a sample interval. This value is specified in seconds and ranges from 1 minute to 1 hour." SYNTAX Unsigned32 (60..3600) CgspPercentThreshold ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention defines the allowed values used to define a threshold. This value is specified as percentage of link utilization. A value of zero indicates that this specific threshold is to be ignored." SYNTAX Unsigned32 (0..100) CgspLinkTestResults ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This object provides information on result from signalling link test procedures as follows. 'noErrors' : Link test did not detect any errors. 'undefinedOpc' : A signalling link test message was received with an undefined originating point code. 'incorrectOpc' : A signalling link test message was received with an incorrect originating point code. 'undefinedSlc' : A signalling link test message was received with an undefined signalling link code. 'incorrectSlc' : A signalling link test message was received with an incorrect signalling link code.. 'incorrectNi' : A signalling link test message was received with an incorrect Network Indicator. 'badPattern' : A signalling link test message was received with an incorrect test pattern. This may be caused by variant mismatched or incorrect definitions on physical link. 'nonAdjacent' :Received a signalling link test message from an non-adjacent node. 'failed' :Unable to run test or no response was received within the specified interval." SYNTAX INTEGER { noErrors(0), undefinedOpc(1), incorrectOpc(2), undefinedSlc(3), incorrectSlc(4), incorrectNi(5), badPattern(6), nonAdjacent(7), failed(8) } CgspLinkUtilization ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention defines a range of values that represent a link's utilization during an interval of time. The values expressed as a percent of link capacity. Any value over 999 will be represented as 999. For SS7 links based on IP/SCTP the link capacity is not directly related to the interface speed used to transmit packets. This is different from serial and HSL links. The capacity of these types of links depend on the amount of resources available in the IP cloud. The IP cloud must be provisioned to support traffic for all SS7 links. In order to monitor link utilization on IP/SCTP based SS7 links a planned capacity must be specified. If this value is incorrectly estimated or traffic exceeds this expected value link utilization may exceed 100 percent. This is possible because the IP cloud may be provisioned with additional capacity or may discard less important traffic based on QoS parameters. When a SS7 link has not be configured for link utilization monitoring this value object will have a value of zero." SYNTAX Gauge32 (0..999) CgspLinkCapacity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention defines the planned capacity of a SS7 link in bit per second. When the cgspLinkType object is 'sctpIp' or 'hsl' the link capacity can be obtained from information in the IF-MIB. When the cgspLinkType object is 'sctpIp' a value of zero indicates that link utilization should not be calculated for this SS7 link." SYNTAX Unsigned32 (0..0 | 56000..2147483647) CgspProfileName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The configured name associated with a Signalling Point Profile. An octet string specified by an administrator that must be in human-readable form. The names must conform to the allowed characters that can be specified via Command Line Interface(CLI). The names cannot contain control character and should not contain leading or trailing white space." SYNTAX OCTET STRING (SIZE (0..19)) CgspLinkUtilizationState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Link Utilization State as follows: 'unMonitored' - traffic for a specified direction is not being monitored. 'underThreshold' - traffic for a specified direction on a link is below the specified threshold. 'overThreshold' - traffic for a specified direction on a link is above to or exceeds the specified threshold." SYNTAX INTEGER { unMonitored(0), underThreshold(1), overThreshold(2) } CgspTimerNumbers ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumerated values for all timers" SYNTAX INTEGER { timerMtp3T01(1), -- Delay to avoid message -- mis-sequencing on changeover. timerMtp3T02(2), -- Waiting for changeover -- acknowledgement. timerMtp3T03(3), -- Time controlled -- diversion-delay to avoid -- mis-sequencing on change back. timerMtp3T04(4), -- Waiting for change back -- acknowledgement (first -- attempt). timerMtp3T05(5), -- Waiting for change back -- acknowledgement (second -- attempt) timerMtp3T06(6), -- Delay to avoid message -- mis-sequencing on controlled -- rerouting timerMtp3T07(7), -- Waiting for signalling data -- link connection -- acknowledgement timerMtp3T08(8), -- Transfer prohibited inhibition -- timer (transient solution) timerMtp3T09(9), -- Reserved timerMtp3T10(10), -- Waiting to repeat signalling -- routeset test message timerMtp3T11(11), -- Transfer restricted timer timerMtp3T12(12), -- Waiting for uninhibit -- acknowledgement timerMtp3T13(13), timerMtp3T14(14), -- Waiting for inhibition -- acknowledgement timerMtp3T15(15), -- Waiting to start signalling -- routeset congestion timerMtp3T16(16), -- Waiting for routeset -- congestion status update timerMtp3T17(17), -- Delay to avoid oscillation of -- initial alignment failure and -- link restart timerMtp3T18(18), -- ANSI: Repeat TFR once by -- response method ITU: MTP -- restart link supervision timerMtp3T19(19), -- ANSI: failed craft timer -- referral timer ITU: -- supervision timer during MTP -- restart timerMtp3T20(20), -- ANSI: waiting to repeat local -- inhibit test ITU: MTP restart -- timer at the signalling point timerMtp3T21(21), -- ANSI: waiting to repeat -- remote inhibit test) ITU: MTP -- restart timer at adjacent -- signalling point timerMtp3T22(22), -- ANSI: restarting SP waiting -- for signalling links avail -- ITU: local inhibit test timer timerMtp3T23(23), -- ANSI: restarting SP waiting -- to receive all TRA msgs ITU: -- remote inhibit test timer timerMtp3T24(24), -- ANSI: restarting SP waiting -- to broadcast all TRA msgs -- ITU: stabilizing timer after -- local processor outage timerMtp3T25(25), -- Timer at Signalling Point -- (SP) adjacent to restarting -- Signalling Point, waiting for -- traffic restart allowed -- message. timerMtp3T26(26), -- Timer at restarting SP -- waiting to repeat traffic -- restart waiting message. timerMtp3T27(27), -- Minimum duration of -- unavailability for full -- restart timerMtp3T28(28), -- Timer at SP adjacent to -- restarting SP waiting for -- traffic restart waiting -- message timerMtp3T29(29), -- Timer started when TRA sent -- in response to unexpected TRA -- or TRW timerMtp3T30(30), -- Timer to limit sending of -- TFPs and TFRs in response to -- unexpected TRA or TRW timerMtp3T31(31), -- False link congestion -- detection timer timerMtp3T32(32), -- Link oscillation timer - -- Procedure A timerMtp3T33(33), -- Probation timer for link -- oscillation - Procedure B timerMtp3T34(34), -- Suspension timer for link -- oscillation - Procedure B timerLinkTest(35), -- Signalling Link Test -- Acknowledgement timer timerLinkMessag1(36), -- Interval timer for -- sending test messages timerLinkActRetry(37), -- Link activation retry -- timer. timerMtp2T01(38), -- Link alignment ready timer timerMtp2T02(39), -- Link not aligned timer timerMtp2T03(40), -- Link aligned timer timerMtp2T04N(41), -- Link proving normal timer timerMtp2T04E(42), timerMtp2T05(43), -- Sending SIB timer timerMtp2T06(44), -- Remote congestion timer timerMtp2T07(45) } CgspTimerValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Value of timers in milliseconds as follows. A value of zero indicates that the timer is not applicable for variant or link type. The values specified in this textual convention apply to the various timers identified in CgspTimerNumbers textual convention. ANSI ITU Min Max Def Min Max Def ------ ------ ------ ------ ------ ------ TimerMtp3T01 500 1200 800 500 1200 800 TimerMtp3T02 700 2000 1400 700 2000 1400 TimerMtp3T03 500 1200 800 500 1200 800 TimerMtp3T04 500 1200 800 500 1200 800 TimerMtp3T05 500 1200 800 500 1200 800 TimerMtp3T06 500 1200 800 500 1200 800 TimerMtp3T07 1000 2000 1500 1000 2000 1500 TimerMtp3T08 800 1200 1000 800 1200 1000 TimerMtp3T10 30000 60000 45000 30000 60000 45000 TimerMtp3T11 30000 90000 60000 30000 90000 60000 TimerMtp3T12 800 1500 1150 800 1500 1150 TimerMtp3T13 800 1500 1150 800 1500 1150 TimerMtp3T14 2000 3000 2500 2000 3000 2500 TimerMtp3T15 2000 3000 2500 2000 3000 2500 TimerMtp3T16 1400 2000 1700 1400 2000 1700 TimerMtp3T17 800 1500 1150 800 1500 1150 TimerMtp3T18 2000 20000 11000 1000 31000 30000 TimerMtp3T19 480000 600000 540000 67000 69000 68000 TimerMtp3T20 90000 120000 105000 1000 61000 60000 TimerMtp3T21 90000 120000 105000 63000 65000 64000 TimerMtp3T22 36000 60000 30000 80000 360000 300000 TimerMtp3T23 9000 60000 30000 80000 360000 300000 TimerMtp3T24 9000 60000 30000 500 500 500 TimerMtp3T25 30000 35000 30000 n/a n/a n/a TimerMtp3T26 12000 15000 12000 n/a n/a n/a TimerMtp3T27 2000 50000 4000 n/a n/a n/a TimerMtp3T28 3000 35000 30000 n/a n/a n/a TimerMtp3T29 60000 65000 63000 n/a n/a n/a TimerMtp3T30 30000 35000 33000 n/a n/a n/a TimerMtp3T31 10000 120000 60000 n/a n/a n/a TimerMtp3T32 5000 120000 60000 n/a n/a n/a TimerMtp3T33 60000 600000 300000 n/a n/a n/a TimerMtp3T34 5000 120000 60000 n/a n/a n/a TimerLinkTest 4000 12000 8000 n/a n/a n/a TimerLinkMessage 30000 90000 60000 n/a n/a n/a TimerLinkActRetry 60000 90000 60000 n/a n/a n/a" REFERENCE "ITU Q.703 Signalling Link. ANSI T1.111.3 Telecommunications - signalling system No. 7 (SS7)-Message Transfer Part (MTP)." SYNTAX Unsigned32 (0..0 | 1..4294967295) CgspSS7Variant ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The list of SS7 variants. 'unknown' : Unknown or undefined variant. 'ANSI' : The ANSI variant of the SS7 specification. 'ITU' : The ITU variant of the SS7 specification. 'China' : The China national variant. This variant is a combination of ITU and ANSI. The protocol matches ITU except where the point-code has been expanded to ANSI format. 'NTT' : The Japanese Nippon Telephone & Telegraph variant. 'TTC' : The Japanese Telecommunications Technology Committee variant." REFERENCE "GF 001-9001 - Technical Specifications of Signalling System No. 7 for National Telephone Network of China." SYNTAX INTEGER { unknown(0), ansi(1), itu(2), china(3), ntt(4), ttc(5) } CgspDisplayInstanceUserPart ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The instance name and user part information formatted for display. If instance name is not configured, the default local point code in ASCII string format will be provided as instance name." SYNTAX OCTET STRING (SIZE (0..40)) CItpTcSccpWrrOption ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The possible options for calculate sccp class1 traffic loadshare when GTT application group's multiplicity mode is WRR(Weighted round robin): 'sls' : Use sls to calculate loadsharing 'cgpaSls' : Use the combination of cgpa and sls to calculate loadsharing 'opcSls' : Use the combination of opc and sls to calculate loadsharing 'opc' : Use the opc to caculate loadsharing" SYNTAX INTEGER { sls(0), cgpaSls(1), opcSls(2), opc(3) } -- ************************************************************* -- * * -- * GSP - Scalar * -- * * -- ************************************************************* cgspCLLICode OBJECT-TYPE SYNTAX CItpTcCLLI MAX-ACCESS read-write STATUS current DESCRIPTION "Common-Language Location Identification Codes (CLLI Codes). This object identifies the physical location of this device and can provide additional informaton on the device type." ::= { cgspScalars 1 } cgspUtilSampleInterval OBJECT-TYPE SYNTAX CgspSampleInterval UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the time interval used to monitor the utilization of SS7 links. This object in combination with cgspUtilThreshold, cgspLinkPlanCapacitySent and cgspLinkPlanCapacityRcvd will be used to calculate utilization of SS7 links. Changes to the polling interval will take effect after the completion of the current sample interval." DEFVAL { 300 } ::= { cgspScalars 2 } cgspUtilThreshold OBJECT-TYPE SYNTAX CgspPercentThreshold UNITS "percent" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the threshold of usage for all SS7 links in SP. This object is used to determine when to generate the ciscoGspLinkRcvdUtilChange or ciscoGspLinkSentUtilChange notifications. A value of zero indicates that no default threshold is specified. Therefore, only links with non-zero values for cgspLinkUtilThresholdRcvd or cgspLinkUtilThresholdSent will generate notifications based on link utilization. Changes to the utilization threshold will take effect at the end of the current interval." DEFVAL { 40 } ::= { cgspScalars 3 } cgspUtilAbateDelta OBJECT-TYPE SYNTAX CgspPercentThreshold UNITS "percent" MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the falling threshold to be lower than the rising threshold when calculating whether to generate the ciscoGspLinkRcvdUtilChange or ciscoGspLinkSentUtilChange notifications. This is done to prevent generating notifications for slight changes in traffic." DEFVAL { 0 } ::= { cgspScalars 4 } cgspPlanCapacityDefault OBJECT-TYPE SYNTAX CgspLinkCapacity UNITS "bits per second" MAX-ACCESS read-write STATUS current DESCRIPTION "This object provides a default for value for links with a cgspLinkType='sctpIp'. For all other types of linkset this value is ignored. When a linkset based on SCTP/IP and the values for the cgspLinkPlanCapacityRcvd or cgspLinkPlanCapacitySent object are zero then this object will be used as the default. A value of zero indicates that a global default has not been specified. This object will be used in combination with cgspUtilSampleInterval, cgspUtilThreshold, cgspUtilThreshold and cgspLinkUtilThresholdRcvd to generate the ciscoGspLinkRcvdUtilChange notification." ::= { cgspScalars 5 } cgspEventSequenceNumber OBJECT-TYPE SYNTAX Counter32 UNITS "events" MAX-ACCESS read-only STATUS current DESCRIPTION "Each event or notification is required to provide a sequence number to be used by the NMS to determine when messages from a particular device are missing. This value will included in each SS7 notification issued by this device." REFERENCE "GR-82-CORE 6.6.1 Event Report Content R6-33" ::= { cgspScalars 6 } cgspUPUNotifWindowTime OBJECT-TYPE SYNTAX Integer32 (60..86400) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the time interval used to monitor the ciscoGspUPUReceived and ciscoGspUPUTransmitted notifications for specific user part and signalling point instance. The first occurrence of ciscoGspUPUReceived and ciscoGspUPUTransmitted notifications are sent and the further occurrences of notifications in this interval are suppressed. At the end of this interval, a notification is sent with total number of UPU MSUs transmitted or received during this interval." DEFVAL { 900 } ::= { cgspScalars 7 } -- ************************************************************* -- * * -- * Profile Table * -- * * -- ************************************************************* cgspProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspProfileTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the Profiles of signalling points. Entries are added to this table via cgspProfileRowStatus in accordance with the RowStatus convention." ::= { cgspProfile 1 } cgspProfileTableEntry OBJECT-TYPE SYNTAX CgspProfileTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Profile attributes. Profiles are used to specify common configuration options for SS7 links without customizing each link. A profile is created with the specified values using this table and the cgspProfileTimerTable Table. The common values are applied to all links in a linkset by specifying the cgspLinksetProfileName on the linkset." INDEX { cgspProfileName } ::= { cgspProfileTable 1 } CgspProfileTableEntry ::= SEQUENCE { cgspProfileName CgspProfileName, cgspProfileVariant CgspSS7Variant, cgspProfileMtp2BundleTimer Integer32, cgspProfileMtp2SendQueueDepth Integer32, cgspProfileRowStatus RowStatus } cgspProfileName OBJECT-TYPE SYNTAX CgspProfileName MAX-ACCESS not-accessible STATUS current DESCRIPTION "Name of the profile." ::= { cgspProfileTableEntry 1 } cgspProfileVariant OBJECT-TYPE SYNTAX CgspSS7Variant MAX-ACCESS read-create STATUS current DESCRIPTION "The SS7 variant used to format data specified in this profile." ::= { cgspProfileTableEntry 2 } cgspProfileMtp2BundleTimer OBJECT-TYPE SYNTAX Integer32 (0..0 | 5..10000) MAX-ACCESS read-create STATUS current DESCRIPTION "Bundle timer value. This value is used to control the bundling of SS7 packets as they are transported within the device. The value of zero indicates that MTP3 packets will not be bundled for transmission as they arrival for transmission at the MTP2 layer. A non-zero value specifies the maximum delay time used to collect MTP3 packets before they are transmitted by the MTP2 layer." ::= { cgspProfileTableEntry 3 } cgspProfileMtp2SendQueueDepth OBJECT-TYPE SYNTAX Integer32 (25..32000) MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum Queue depth allowed per link for MTP2 waiting to be transmitted." ::= { cgspProfileTableEntry 4 } cgspProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspProfileTable following the RowStatus textual convention." ::= { cgspProfileTableEntry 5 } -- ************************************************************* -- * * -- * Profile Timer Table * -- * * -- ************************************************************* cgspProfileTimerTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspProfileTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains a profile of timers used to configure SS7 links. Entries are added to this table via cgspProfileTimerRowStatus in accordance with the RowStatus convention." ::= { cgspProfile 2 } cgspProfileTimerTableEntry OBJECT-TYPE SYNTAX CgspProfileTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ProfileTimer attributes. Profiles are used to specify common timer configuration options for SS7 links without customizing each link. A profile is created with the specified values using this table and the cgspProfileTable Table. The common values are applied to all links in a linkset by specifying the cgspLinksetProfileName on the linkset." INDEX { cgspInstNetwork, cgspProfileTimerNumber } ::= { cgspProfileTimerTable 1 } CgspProfileTimerTableEntry ::= SEQUENCE { cgspProfileTimerNumber CgspTimerNumbers, cgspProfileTimerValue CgspTimerValue, cgspProfileTimerRowStatus RowStatus } cgspProfileTimerNumber OBJECT-TYPE SYNTAX CgspTimerNumbers MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into table containing timer information." ::= { cgspProfileTimerTableEntry 1 } cgspProfileTimerValue OBJECT-TYPE SYNTAX CgspTimerValue UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Value of timer selected by cgspProfileTimerNumber object." ::= { cgspProfileTimerTableEntry 2 } cgspProfileTimerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspProfileTimerTable following the RowStatus textual convention." ::= { cgspProfileTimerTableEntry 3 } -- ************************************************************* -- * * -- * Instance Table * -- * * -- ************************************************************* cgspInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspInstanceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the instances of signalling points. Entries are added to this table via cgspInstRowStatus in accordance with the RowStatus convention." ::= { cgspInstance 1 } cgspInstanceTableEntry OBJECT-TYPE SYNTAX CgspInstanceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of instance attributes." INDEX { cgspInstNetwork } ::= { cgspInstanceTable 1 } CgspInstanceTableEntry ::= SEQUENCE { cgspInstNetwork CItpTcNetworkName, cgspInstNetworkIndicator CItpTcNetworkIndicator, cgspInstVariant CgspSS7Variant, cgspInstDisplayName SnmpAdminString, cgspInstDescription SnmpAdminString, cgspInstTFR TruthValue, cgspInstCongestionsLevels TruthValue, cgspInstFastRestart TruthValue, cgspInstDistSccpUnseq TruthValue, cgspInstSummaryRoutingException TruthValue, cgspInstNumber CItpTcInstanceNumber, cgspInstRouteTableName CItpTcRouteTableName, cgspInstRowStatus RowStatus, cgspInstSccpWrrOpcShift Unsigned32, cgspInstSccpWrrOption CItpTcSccpWrrOption } cgspInstNetwork OBJECT-TYPE SYNTAX CItpTcNetworkName MAX-ACCESS not-accessible STATUS current DESCRIPTION "The network name is used to indicate the network in which this signalling point is participating. One or more instances of signalling points can exist in the same physical device. This identifier will be used to correlate instances of signalling points by network. When multiple instance support is not enabled the network name will default to the null string. An octet string specified by an administrator that must be in human-readable form. The names must conform to the allowed characters that can be specified via Command Line Interface(CLI). The names cannot contain control character and should not contain leading or trailing white space." ::= { cgspInstanceTableEntry 1 } cgspInstNetworkIndicator OBJECT-TYPE SYNTAX CItpTcNetworkIndicator MAX-ACCESS read-create STATUS current DESCRIPTION "The Network Indicator for this Signalling point instance." ::= { cgspInstanceTableEntry 2 } cgspInstVariant OBJECT-TYPE SYNTAX CgspSS7Variant MAX-ACCESS read-create STATUS current DESCRIPTION "The SS7 variant used to format data used by this instance." ::= { cgspInstanceTableEntry 3 } cgspInstDisplayName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..30)) MAX-ACCESS read-create STATUS current DESCRIPTION "A short identifier for the Signalling point. This value can be set by system administrator or defaults to the local point code formatted as an ASCII string." ::= { cgspInstanceTableEntry 4 } cgspInstDescription OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-create STATUS current DESCRIPTION "A textual description for the Signalling point." ::= { cgspInstanceTableEntry 5 } cgspInstTFR OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Allow transfer restricted messages. 'true' TFR are allowed. 'false' TFR are disabled." DEFVAL { false } ::= { cgspInstanceTableEntry 6 } cgspInstCongestionsLevels OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Allow multiple congestion levels. 'true' multiple congestion levels are allowed. 'false' multiple congestion levels are disabled." DEFVAL { false } ::= { cgspInstanceTableEntry 7 } cgspInstFastRestart OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "The support for fast restarts as follows. 'true' fast restart is enabled. 'false' fast restart is disabled." DEFVAL { false } ::= { cgspInstanceTableEntry 8 } cgspInstDistSccpUnseq OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Evenly distribute Class 0 SCCP messages as follows. 'true' Evenly distribute 0 SCCP messages is enabled. 'false' Evenly distribute 0 SCCP messages is disabled." DEFVAL { false } ::= { cgspInstanceTableEntry 9 } cgspInstSummaryRoutingException OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to control the usage of the summary route when both a summary route (or ANSI cluster route) and a full point-code route (within that summary) are configured. The object is used to indicate whether the summary route is to be used when the full point-code destination is inaccessible as follows. 'true' Use summary routing. 'false' Do not use summary routing." DEFVAL { true } ::= { cgspInstanceTableEntry 10 } cgspInstNumber OBJECT-TYPE SYNTAX CItpTcInstanceNumber MAX-ACCESS read-only STATUS current DESCRIPTION "A unique Identifier assigned to each instance." ::= { cgspInstanceTableEntry 11 } cgspInstRouteTableName OBJECT-TYPE SYNTAX CItpTcRouteTableName MAX-ACCESS read-create STATUS current DESCRIPTION "The routing table for Signalling network management messages." REFERENCE "ITU Q.704 Signalling network functions and messages, section 14.2.1." ::= { cgspInstanceTableEntry 12 } cgspInstRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspInstanceTable following the RowStatus textual convention." ::= { cgspInstanceTableEntry 13 } cgspInstSccpWrrOpcShift OBJECT-TYPE SYNTAX Unsigned32 (0..8) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the shift amount for the OPC bits in SCCP class1 WRR(Weighted round robin). The range depends on the variant as follows. The ITU range is 0-2 The ANSI range is 0-8 The CHINA range is 0-2 The JAPAN NTT range is 0-2 The JAPAN TTC range is 0-2" ::= { cgspInstanceTableEntry 14 } cgspInstSccpWrrOption OBJECT-TYPE SYNTAX CItpTcSccpWrrOption MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicate the options for calculate SCCP class 1 traffic loadshare under WRR" ::= { cgspInstanceTableEntry 15 } -- ************************************************************* -- * * -- * Instance Timer Table * -- * * -- ************************************************************* cgspInstTimerTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspInstTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the timer used to configure an instances of signalling points. Entries are added to this table via cgspInstTimerRowStatus in accordance with the RowStatus convention." ::= { cgspInstance 2 } cgspInstTimerTableEntry OBJECT-TYPE SYNTAX CgspInstTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to configure all MTP3 timer values that apply to linksets and links. The values apply to all linkset and links defined to this signalling point(instances)." INDEX { cgspInstNetwork, cgspInstTimerNumber } ::= { cgspInstTimerTable 1 } CgspInstTimerTableEntry ::= SEQUENCE { cgspInstTimerNumber CgspTimerNumbers, cgspInstTimerValue CgspTimerValue, cgspInstTimerRowStatus RowStatus } cgspInstTimerNumber OBJECT-TYPE SYNTAX CgspTimerNumbers MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into table containing timer information." ::= { cgspInstTimerTableEntry 1 } cgspInstTimerValue OBJECT-TYPE SYNTAX CgspTimerValue UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Value of timer selected by cgspInstTimerNumber object." ::= { cgspInstTimerTableEntry 2 } cgspInstTimerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspInstTimerTable following the RowStatus textual convention." ::= { cgspInstTimerTableEntry 3 } -- ************************************************************* -- * * -- * Instance UPU Table * -- * * -- ************************************************************* cgspInstUPUTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspInstUPUTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Instance UPU table contains information about the number of UPU MSUs transmitted and received for the specific user part(represented by service indicator) and signalling point instance. The user part is primarily represented with the possible service indicator. This table provides the granularity of information required by Q752 table 5.6 and 5.7." ::= { cgspInstance 3 } cgspInstUPUTableEntry OBJECT-TYPE SYNTAX CgspInstUPUTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each table entry represent the UPU MSU statistics for a specific user part and signalling point instance." INDEX { cgspInstNetwork, cgspMtp3SI } ::= { cgspInstUPUTable 1 } CgspInstUPUTableEntry ::= SEQUENCE { cgspMtp3SI CItpTcServiceIndicator, cgspInstSIUPUReceived Counter32, cgspInstSIUPUTransmitted Counter32, cgspInstUserPartDisplay CgspDisplayInstanceUserPart } cgspMtp3SI OBJECT-TYPE SYNTAX CItpTcServiceIndicator MAX-ACCESS not-accessible STATUS current DESCRIPTION "The service indicator." ::= { cgspInstUPUTableEntry 1 } cgspInstSIUPUReceived OBJECT-TYPE SYNTAX Counter32 UNITS "MSUs" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of UPU MSUs that were received for the associated user part(service indicator) and and signalling point instance Q752/5.7." REFERENCE "ANSI GR-82-CORE 6.4.2 System Total Measurements Item 33 measurements received from remote Signalling point." ::= { cgspInstUPUTableEntry 2 } cgspInstSIUPUTransmitted OBJECT-TYPE SYNTAX Counter32 UNITS "MSUs" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of UPU MSUs that were transmitted for the associated user part(service indicator) and and signalling point instance." REFERENCE "ANSI GR-82-CORE 6.4.2 System Total Measurements Item 33." ::= { cgspInstUPUTableEntry 3 } cgspInstUserPartDisplay OBJECT-TYPE SYNTAX CgspDisplayInstanceUserPart MAX-ACCESS read-only STATUS current DESCRIPTION "The associated instance name and user part information formatted for display." ::= { cgspInstUPUTableEntry 4 } -- ************************************************************* -- * * -- * Point Code Table * -- * * -- ************************************************************* cgspPointCodeTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspPointCodeTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains a list of point code defined for the Signalling point defined by this instance. Entries are added to this table via cgspPointCodeRowStatus in accordance with the RowStatus convention." ::= { cgspPointCode 1 } cgspPointCodeTableEntry OBJECT-TYPE SYNTAX CgspPointCodeTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Point codes for a signalling point defined by an instance." INDEX { cgspInstNetwork, cgspPointCodeNi, cgspPointCodeBin } ::= { cgspPointCodeTable 1 } CgspPointCodeTableEntry ::= SEQUENCE { cgspPointCodeNi CItpTcNetworkIndicator, cgspPointCodeBin CItpTcPointCode, cgspPointCodeType CItpTcPointCodeType, cgspPointCodeDisplay CItpTcDisplayPC, cgspPointCodeRowStatus RowStatus } cgspPointCodeNi OBJECT-TYPE SYNTAX CItpTcNetworkIndicator MAX-ACCESS not-accessible STATUS current DESCRIPTION "The network Indicator for this pointcode." ::= { cgspPointCodeTableEntry 1 } cgspPointCodeBin OBJECT-TYPE SYNTAX CItpTcPointCode MAX-ACCESS not-accessible STATUS current DESCRIPTION "The point code for this Signalling Point." ::= { cgspPointCodeTableEntry 2 } cgspPointCodeType OBJECT-TYPE SYNTAX CItpTcPointCodeType MAX-ACCESS read-create STATUS current DESCRIPTION "The function of this point code." ::= { cgspPointCodeTableEntry 3 } cgspPointCodeDisplay OBJECT-TYPE SYNTAX CItpTcDisplayPC MAX-ACCESS read-only STATUS current DESCRIPTION "The point code for this Signalling Point." ::= { cgspPointCodeTableEntry 4 } cgspPointCodeRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspPointCodeTable following the RowStatus textual convention." ::= { cgspPointCodeTableEntry 5 } -- ************************************************************* -- * * -- * Linkset Table * -- * * -- ************************************************************* cgspLinksetTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspLinksetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of linksets for this Signalling Point defined by this instance." ::= { cgspLinkset 1 } cgspLinksetTableEntry OBJECT-TYPE SYNTAX CgspLinksetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Signalling Point linkset attributes for Signalling Point define by this instance." INDEX { cgspInstNetwork, cgspLinksetName } ::= { cgspLinksetTable 1 } CgspLinksetTableEntry ::= SEQUENCE { cgspLinksetName CItpTcLinksetId, cgspLinksetSourcePointCode CItpTcPointCode, cgspLinksetSourceDisplayPC CItpTcDisplayPC, cgspLinksetAdjacentPointCode CItpTcPointCode, cgspLinksetAdjacentDisplayPC CItpTcDisplayPC, cgspLinksetState INTEGER, cgspLinksetInboundAcl CItpTcAclId, cgspLinksetOutboundAcl CItpTcAclId, cgspLinksetAccountingMtp3 TruthValue, cgspLinksetAccountingGtt TruthValue, cgspLinksetNumLinks Unsigned32, cgspLinksetDurationInService Counter32, cgspLinksetDurationOutService Counter32, cgspLinksetActPriority Unsigned32, cgspLinksetDisplayName SnmpAdminString, cgspLinksetDescription SnmpAdminString, cgspLinksetRotateSlsEnable TruthValue, cgspLinksetRotateSlsShift Unsigned32, cgspLinksetProfileName CgspProfileName, cgspLinksetAdjacentInst CItpTcNetworkName, cgspLinksetRowStatus RowStatus } cgspLinksetName OBJECT-TYPE SYNTAX CItpTcLinksetId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The name of the linkset." ::= { cgspLinksetTableEntry 1 } cgspLinksetSourcePointCode OBJECT-TYPE SYNTAX CItpTcPointCode MAX-ACCESS read-create STATUS current DESCRIPTION "The point code to which this linkset is connected." ::= { cgspLinksetTableEntry 2 } cgspLinksetSourceDisplayPC OBJECT-TYPE SYNTAX CItpTcDisplayPC MAX-ACCESS read-only STATUS current DESCRIPTION "The point code to which this linkset is connected." ::= { cgspLinksetTableEntry 3 } cgspLinksetAdjacentPointCode OBJECT-TYPE SYNTAX CItpTcPointCode MAX-ACCESS read-create STATUS current DESCRIPTION "The point code to which this linkset is connected." ::= { cgspLinksetTableEntry 4 } cgspLinksetAdjacentDisplayPC OBJECT-TYPE SYNTAX CItpTcDisplayPC MAX-ACCESS read-only STATUS current DESCRIPTION "The point code to which this linkset is connected." ::= { cgspLinksetTableEntry 5 } cgspLinksetState OBJECT-TYPE SYNTAX INTEGER { available(1), shutdown(2), unavailable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The list of possible linkset states. 'available' : Traffic may flow over this linkset 'shutdown' : This linkset has been forced to an unavailable state by an administrative action. 'unavailable': The linkset is currently unable to support traffic. Activation of this linkset will occur as required by protocol." ::= { cgspLinksetTableEntry 6 } cgspLinksetInboundAcl OBJECT-TYPE SYNTAX CItpTcAclId MAX-ACCESS read-create STATUS current DESCRIPTION "Packets are filtered against this access control list before they are passed to the routing function. A value of zero indicates that no access control list is present." ::= { cgspLinksetTableEntry 7 } cgspLinksetOutboundAcl OBJECT-TYPE SYNTAX CItpTcAclId MAX-ACCESS read-create STATUS current DESCRIPTION "Packets are filtered against this access control list after they have passed through the routing function. A value of zero indicates that no access control list is present." ::= { cgspLinksetTableEntry 8 } cgspLinksetAccountingMtp3 OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates if accounting for this linkset is enabled. 'true' Indicates that the accounting function is enabled for this linkset and is being accumulated in cgactMtp3Table. 'false' Indicates that the accounting function is disabled." DEFVAL { false } ::= { cgspLinksetTableEntry 9 } cgspLinksetAccountingGtt OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates if accounting for this linkset is enabled. 'true' Indicates that the accounting function is enabled for this linkset and is being accumulated in cgactMtp3Table. 'false' Indicates that the accounting function is disabled." DEFVAL { false } ::= { cgspLinksetTableEntry 10 } cgspLinksetNumLinks OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of links in this linkset." ::= { cgspLinksetTableEntry 11 } cgspLinksetDurationInService OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time linkset was providing service related to Q752/Table 4.2." ::= { cgspLinksetTableEntry 12 } cgspLinksetDurationOutService OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time linkset was Out-of-Service as required for Q752/Table 4.2." ::= { cgspLinksetTableEntry 13 } cgspLinksetActPriority OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Defines the activation priority for linksets. The linksets with the lowest values will be activated first. If two or more linksets share the same values they will be activated in the order they were defined." DEFVAL { 0 } ::= { cgspLinksetTableEntry 14 } cgspLinksetDisplayName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..30)) MAX-ACCESS read-create STATUS current DESCRIPTION "A short identifier for each linkset. This value can be set by system administrator or defaults to the linkset name." ::= { cgspLinksetTableEntry 15 } cgspLinksetDescription OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-create STATUS current DESCRIPTION "A textual description for the Signalling point." ::= { cgspLinksetTableEntry 16 } cgspLinksetRotateSlsEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This defines whether signalling link selector(SLS) will be rotated. This option only applies to ANSI variant and will return false for all other variants. By default SLS rotation is enable by default for ANSI linksets. ANSI specifications state that SLS rotation should not be performed on C type linksets. This object can be used to disable SLS rotation. 'true' Indicates that SLS rotation is enable for this linkset. 'false' Indicates that SLS rotation is disable for this linkset." ::= { cgspLinksetTableEntry 17 } cgspLinksetRotateSlsShift OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This value used to shift the signalling link selector(SLS) when rotation is enabled. This option only applies to ANSI variant and will return 0 all other variants." ::= { cgspLinksetTableEntry 18 } cgspLinksetProfileName OBJECT-TYPE SYNTAX CgspProfileName MAX-ACCESS read-create STATUS current DESCRIPTION "When specified this object indicates which profile will be used to establish defaults for common configuration values like MTP2 and MTP3 timers. The null string is used to indicate that the linkset does not have a profile." ::= { cgspLinksetTableEntry 19 } cgspLinksetAdjacentInst OBJECT-TYPE SYNTAX CItpTcNetworkName MAX-ACCESS read-only STATUS current DESCRIPTION "When a linkset is used to carry traffic between different instances, this object contains the network name used as an index into the cgspInstanceTable table. In all other cases the object will contain the same network name as the source signalling point." ::= { cgspLinksetTableEntry 20 } cgspLinksetRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspLinksetTable following the RowStatus textual convention." ::= { cgspLinksetTableEntry 21 } -- ************************************************************* -- * * -- * Linkset Timer Table * -- * * -- ************************************************************* cgspLinksetTimerTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspLinksetTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the timer used to configure timer values specific to a particular linkset. Entries are added to this table via cgspLinksetTimerRowStatus in accordance with the RowStatus convention." ::= { cgspLinkset 2 } cgspLinksetTimerTableEntry OBJECT-TYPE SYNTAX CgspLinksetTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to configure all MTP3 timer values that apply to linksets and links. The values apply to this linkset and links it c contains." INDEX { cgspInstNetwork, cgspLinksetName, cgspLinksetTimerNumber } ::= { cgspLinksetTimerTable 1 } CgspLinksetTimerTableEntry ::= SEQUENCE { cgspLinksetTimerNumber CgspTimerNumbers, cgspLinksetTimerValue CgspTimerValue, cgspLinksetTimerRowStatus RowStatus } cgspLinksetTimerNumber OBJECT-TYPE SYNTAX CgspTimerNumbers MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into table containing timer information." ::= { cgspLinksetTimerTableEntry 1 } cgspLinksetTimerValue OBJECT-TYPE SYNTAX CgspTimerValue UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Value of timer selected by cgspLinksetTimerNumber object." ::= { cgspLinksetTimerTableEntry 2 } cgspLinksetTimerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspLinksetTimerTable following the RowStatus textual convention." ::= { cgspLinksetTimerTableEntry 3 } -- ************************************************************* -- * * -- * GSP - Link Table * -- * * -- ************************************************************* cgspLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspLinkTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of links for each Signalling Point." ::= { cgspLink 1 } cgspLinkTableEntry OBJECT-TYPE SYNTAX CgspLinkTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of signalling point link attributes." INDEX { cgspInstNetwork, cgspLinksetName, cgspLinkSlc } ::= { cgspLinkTable 1 } CgspLinkTableEntry ::= SEQUENCE { cgspLinkSlc CItpTcLinkSLC, cgspLinkDescription SnmpAdminString, cgspLinkState INTEGER, cgspLinkReason INTEGER, cgspLinkType CItpTcLinkType, cgspLinkifIndex InterfaceIndexOrZero, cgspLinkSctpAssociation Unsigned32, cgspLinkXmitQueueDepth Gauge32, cgspLinkXmitQueueDepthHigh Unsigned32, cgspLinkXmitQueueDepthHighRT TimeStamp, cgspLinkCongestionState Unsigned32, cgspLinkCongestionAbate1 Unsigned32, cgspLinkCongestionAbate2 Unsigned32, cgspLinkCongestionAbate3 Unsigned32, cgspLinkCongestionOnset1 Unsigned32, cgspLinkCongestionOnset2 Unsigned32, cgspLinkCongestionOnset3 Unsigned32, cgspLinkSigLinkTest TruthValue, cgspLinkQ752T1E1 Counter32, cgspLinkQ752T1E2 Counter32, cgspLinkQ752T1E3 Counter32, cgspLinkQ752T1E5 Counter32, cgspLinkQ752T1E7 Counter32, cgspLinkQ752T1E8 Counter32, cgspLinkQ752T1E9 Counter32, cgspLinkQ752T1E10 Counter32, cgspLinkQ752T1E11 Counter32, cgspLinkQ752T2E1 Counter32, cgspLinkQ752T2E5 Counter32, cgspLinkQ752T2E6 Counter32, cgspLinkQ752T2E7 Counter32, cgspLinkQ752T2E9 Counter32, cgspLinkQ752T2E10 Counter32, cgspLinkQ752T2E15 Counter32, cgspLinkQ752T2E16 Counter32, cgspLinkQ752T2E18 Counter32, cgspLinkQ752T3E1 Counter32, cgspLinkQ752T3E2Bytes Counter32, cgspLinkQ752T3E2Packets Counter32, cgspLinkQ752T3E3 Counter32, cgspLinkQ752T3E4 Counter32, cgspLinkQ752T3E5 Counter32, cgspLinkQ752T3E6 Counter32, cgspLinkQ752T3E7 Counter32, cgspLinkQ752T3E10L1 Counter32, cgspLinkQ752T3E10L2 Counter32, cgspLinkQ752T3E10L3 Counter32, cgspLinkQ752T3E11L1 Counter32, cgspLinkQ752T3E11L2 Counter32, cgspLinkQ752T3E11L3 Counter32, cgspLinkLocalPeerPort InetPortNumber, cgspLinkRemotePeerPort InetPortNumber, cgspLinkQosClass CItpTcQos, cgspLinkDisplayName SnmpAdminString, cgspLinkDroppedPkts Counter32, cgspLinkTransmittedLSSUs Counter32, cgspLinkReceivedLSSUs Counter32, cgspLinkProtocolDetails BITS, cgspLinkLsacState INTEGER, cgspLinkTsrcState INTEGER, cgspLinkTcocState INTEGER, cgspLinkTcocLocalBSNT CgspSequenceNumber, cgspLinkTcocRemoteBSNT CgspSequenceNumber, cgspLinkTcbcState INTEGER, cgspLinkReceivedSIBs Counter32, cgspLinkTransmittedSIBs Counter32, cgspLinkMtp2T01Counts Counter32, cgspLinkMtp2T02Counts Counter32, cgspLinkMtp2T03Counts Counter32, cgspLinkMtp2T04Counts Counter32, cgspLinkMtp2T05Counts Counter32, cgspLinkMtp2T06Counts Counter32, cgspLinkMtp2T07Counts Counter32, cgspLinkOMAERMCounts Counter32, cgspLinkOMAERMFailCounts Counter32, cgspLinkOMSURMCounts Counter32, cgspLinkOMSURMFailCounts Counter32, cgspLinkPlanCapacityRcvd CgspLinkCapacity, cgspLinkUtilThresholdRcvd CgspPercentThreshold, cgspLinkUtilizationRcvd CgspLinkUtilization, cgspLinkUtilStateRcvd CgspLinkUtilizationState, cgspLinkL2BytesRcvd Counter32, cgspLinkPlanCapacitySent CgspLinkCapacity, cgspLinkUtilThresholdSent CgspPercentThreshold, cgspLinkUtilizationSent CgspLinkUtilization, cgspLinkUtilStateSent CgspLinkUtilizationState, cgspLinkL2BytesSent Counter32, cgspLinkTestResult CgspLinkTestResults, cgspLinkRowStatus RowStatus, cgspLinkSctpAssociationId Unsigned32, cgspLinkQ752T1E12 Counter32, cgspLinkQ752T1E12Errors Counter32, cgspLinkQ752T2E11 Counter32, cgspLinkQ752T2E17 Counter32, cgspLinkQ752T2E19 Counter32, cgspLinkRxCongestionState Unsigned32 } cgspLinkSlc OBJECT-TYPE SYNTAX CItpTcLinkSLC MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Signalling Link Code for this link." REFERENCE "ITU Q.704 Signalling network functions and messages. ANSI T1.111 Telecommunications - Signalling system No. 7 (SS7)-Message Transfer Part (MTP)." ::= { cgspLinkTableEntry 1 } cgspLinkDescription OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..254)) MAX-ACCESS read-create STATUS current DESCRIPTION "A textual description for this link." ::= { cgspLinkTableEntry 2 } cgspLinkState OBJECT-TYPE SYNTAX INTEGER { available(1), failed(2), shutdown(3), unavailable(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The list of possible links states. 'available' : Traffic may flow over this linkset 'failed' : Traffic management has detected a failure that prevents activating this linkset. 'shutdown' : This linkset has been forced to an unavailable state by an administrative action. 'unavailable': The linkset is currently unable to support traffic. Activation of this linkset will occur as required by protocol." ::= { cgspLinkTableEntry 3 } cgspLinkReason OBJECT-TYPE SYNTAX INTEGER { unknown(0), changeOverInProgress(1), mgmtDisconnectRequest(2), linkAlignmentLost(3), connectionLost(4), localDisconnect(5), remoteDisconnect(6), suermFailure(7), t1Timeout(8), t2Timeout(9), t3Timeout(10), t6Timeout(11), t7Timeout(12), provingFailure(13), protocolErrorBsn(14), protocolErrorFib(15), protocolErrorSin(16), protocolErrorLssu(17), peerNotReady(18), communicationLost(19), noListenPosted(20), bufferNotAvailable(21), cardRemoved(22), cardInserted(23), falseLinkCongestion(24), configDownload(25), localInhibit(26), localUninhibit(27), remoteInhibit(28), remoteUninhibit(29), localBlocked(30), localUnBlocked(31), remoteBlocked(32), remoteUnblocked(33), linkRestored(34), linkTestFailure(35) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides additional information on the source of a link failure. This object will contain the last reason that caused the link to fail. 'unknown' : Link has failed do to an undetermined cause. 'changeOverInProgress' : Change over in progress. 'mgmtDisconnectRequest' : Management disconnect request. 'linkAlignmentLost' : Link alignment lost. 'connectionLost' : Link connection lost. 'localDisconnect' : Local Disconnect. 'remoteDisconnect' : Remote Disconnect. 'suermFailure' : Signal unit error rate monitor failure. 't1Timeout' : T1 timeout no FISU received. 't2Timeout' : T2 timeout no SIO received. 't3Timeout' : T3 timeout no SIN received. 't6Timeout' : T6 timeout excessive congestion. 't7Timeout' : T7 timeout excessive acknowledgement delay. 'provingFailure' : Link proving failure. 'protocolError-BSN' : Abnormal BSN received. 'protocolError-FIB' : Abnormal FIB received. 'protocolError-SIN' : Abnormal SIB received. 'protocolError-LSSU' : Abnormal LSSU received. 'peerNotReady' : Peer not ready. 'communicationLost' : Communication lost. 'noListenPosted' : No Listen posted. 'bufferNotAvailable' : Unable to allocate buffer. 'cardRemoved' : Link card removed. 'cardInserted' : Link card Inserted. 'falseLinkCongestion' : false link congestion. 'configDownload' : Configuration downloading. 'localInhibit' : Local request to inhibit link. 'localUninhibit' : Local request to uninhibit link. 'remoteInhibit' : Remote request to inhibit link. 'remoteUninhibit': Local request to uninhibit link. 'localBlocked' : Local Processor outage. 'localUnBlocked' : Local Processor recovery. 'remoteBlocked' : Remote Processor outage. 'remoteUnblocked': Remote Processor recovery. 'linkRestored' : Link restored. 'linkTestFailure': Signalling Link Test failure.'" ::= { cgspLinkTableEntry 4 } cgspLinkType OBJECT-TYPE SYNTAX CItpTcLinkType MAX-ACCESS read-create STATUS current DESCRIPTION "The link type." REFERENCE "For SCTP see RFC 2960." ::= { cgspLinkTableEntry 5 } cgspLinkifIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "If the link type specified by cgspLinkType is serial or high speed Link, this is the ifIndex specified in IF-MIB, otherwise no significance is to be placed on this value." REFERENCE "RFC1213.txt" ::= { cgspLinkTableEntry 6 } cgspLinkSctpAssociation OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Association Identifiers can be greater than 65,535. This object has been replaced by cgspLinkSctpAssociationId." ::= { cgspLinkTableEntry 7 } cgspLinkXmitQueueDepth OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of packets waiting to be sent over this link." ::= { cgspLinkTableEntry 8 } cgspLinkXmitQueueDepthHigh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is the maximum number of packets waiting to be sent over this link since the last time this value was reset as indicated by cgspLinkXmitQueueDepthHighRT. Resetting this object is achieved by setting this object to 0. Attempting to set this object to any other value will result in a wrongValue (SNMPv2c, SNMPv3) or badValue (SNMPv1)." ::= { cgspLinkTableEntry 9 } cgspLinkXmitQueueDepthHighRT OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates when cgspLinkXmitQueueDepthHigh was last set to 0." ::= { cgspLinkTableEntry 10 } cgspLinkCongestionState OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The Signalling link congestion status of this link. 0 is the least congestion level, 3 is the highest congestion level." REFERENCE "ITU Q.704 Signalling network functions and messages. ANSI T1.111 Telecommunications - Signalling system No. 7 (SS7)-Signalling network functions and messages 2.3.5.2." ::= { cgspLinkTableEntry 11 } cgspLinkCongestionAbate1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold used to abate congestion level 1." ::= { cgspLinkTableEntry 12 } cgspLinkCongestionAbate2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold used to abate congestion level 2." ::= { cgspLinkTableEntry 13 } cgspLinkCongestionAbate3 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold used to abate congestion level 3." ::= { cgspLinkTableEntry 14 } cgspLinkCongestionOnset1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold used to mark onset of congestion level 1." ::= { cgspLinkTableEntry 15 } cgspLinkCongestionOnset2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold used to mark onset of congestion level 2." ::= { cgspLinkTableEntry 16 } cgspLinkCongestionOnset3 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "Threshold used to mark onset of congestion level 3." ::= { cgspLinkTableEntry 17 } cgspLinkSigLinkTest OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Indicated if Signalling link test is enabled on this link. true : Signalling link test is enabled. false : Signalling link test not enabled." DEFVAL { true } ::= { cgspLinkTableEntry 18 } cgspLinkQ752T1E1 OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Duration of link in the In-Service state Q752/1.1." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 23-24." ::= { cgspLinkTableEntry 19 } cgspLinkQ752T1E2 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Count of Signalling Link failures - All reasons Q752/1.2." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 29." ::= { cgspLinkTableEntry 20 } cgspLinkQ752T1E3 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of Signalling Link failures - Abnormal FIBR/BSNR Q752/1.3" ::= { cgspLinkTableEntry 21 } cgspLinkQ752T1E5 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of Signalling Link failures - Excessive error rate Q752/1.5." ::= { cgspLinkTableEntry 22 } cgspLinkQ752T1E7 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of alignment or proving errors Q752/1.7." ::= { cgspLinkTableEntry 23 } cgspLinkQ752T1E8 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of signal units received in error Q752/1.8." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 33." ::= { cgspLinkTableEntry 24 } cgspLinkQ752T1E9 OBJECT-TYPE SYNTAX Counter32 UNITS "negative acknowledgements" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of negative acknowledgements received Q752/1.9." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 34." ::= { cgspLinkTableEntry 25 } cgspLinkQ752T1E10 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of 'local automatic changeover' events Q752/1.10." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 25." ::= { cgspLinkTableEntry 26 } cgspLinkQ752T1E11 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of 'local automatic changeback' events Q752/1.11." ::= { cgspLinkTableEntry 27 } -- Q752.12 Signalling Link Restoration The standard only requires -- that an event be issued when this occurs. cgspLinkQ752T2E1 OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Duration of Signalling Link unavailable(for any reason) Q752/2.1." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 30." ::= { cgspLinkTableEntry 28 } -- Q752/2.2 - Q752/2.4 deleted cgspLinkQ752T2E5 OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Duration of Signalling Link unavailable due to local management actions Q752/2.5." ::= { cgspLinkTableEntry 29 } cgspLinkQ752T2E6 OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Duration of Signalling Link unavailable due to remote management actions Q752/2.6." ::= { cgspLinkTableEntry 30 } cgspLinkQ752T2E7 OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Duration of Signalling Link unavailable due to link failure Q752/2.7." ::= { cgspLinkTableEntry 31 } cgspLinkQ752T2E9 OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Duration of Signalling Link unavailable due to remote processor outage Q752/2.9." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 31." ::= { cgspLinkTableEntry 32 } cgspLinkQ752T2E10 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of 'remote processor outage' events Q752/2.10 and Q752/2.11. The standard only requires that events are issued. The entries have been combined into a single entry to track all occurrences of these event types." ::= { cgspLinkTableEntry 33 } cgspLinkQ752T2E15 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of Status Indicator Busy received Q752/2.15." ::= { cgspLinkTableEntry 34 } cgspLinkQ752T2E16 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of local inhibition Q752/2.16 and Q752/2.17. The standard only requires that events are issued. The entries have been combined into a single entry to track all occurrences of these event types." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 27." ::= { cgspLinkTableEntry 35 } cgspLinkQ752T2E18 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of remote inhibition Q752/2.18 and Q752/2.19. The standard only requires that events are issued. The entries have been combined into a single entry to track all occurrences of these event types." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 28." ::= { cgspLinkTableEntry 36 } cgspLinkQ752T3E1 OBJECT-TYPE SYNTAX Counter32 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MTP3 bytes sent by this link. This measurement is specified in Q752/3.1" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 4." ::= { cgspLinkTableEntry 37 } cgspLinkQ752T3E2Bytes OBJECT-TYPE SYNTAX Counter32 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MTP3 bytes retransmitted on this link. This measurement is specified in Q752/3.2" ::= { cgspLinkTableEntry 38 } cgspLinkQ752T3E2Packets OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MTP3 packets retransmitted on this link. This measurement is specified in Q752/3.2" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 3." ::= { cgspLinkTableEntry 39 } cgspLinkQ752T3E3 OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MTP3 packets sent by this link. This measurement is specified in Q752/3.3." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 1." ::= { cgspLinkTableEntry 40 } cgspLinkQ752T3E4 OBJECT-TYPE SYNTAX Counter32 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MTP3 bytes received by this link. This measurement is specified in Q752/3.4" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 5." ::= { cgspLinkTableEntry 41 } cgspLinkQ752T3E5 OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MTP3 packets received by this link. This measurement is specified in Q752/3.5" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 1." ::= { cgspLinkTableEntry 42 } cgspLinkQ752T3E6 OBJECT-TYPE SYNTAX Counter32 UNITS "events" MAX-ACCESS read-only STATUS current DESCRIPTION "The number times this Signalling link was marked congested. This measurement is specified in Q752/3.6" ::= { cgspLinkTableEntry 43 } cgspLinkQ752T3E7 OBJECT-TYPE SYNTAX Counter32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Cumulative duration of Signalling link congestion Q752/3.7." REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 11." ::= { cgspLinkTableEntry 44 } cgspLinkQ752T3E10L1 OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets(MSUs) discarded due to Signalling link level 1 congestion Q752/3.10" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 17-19." ::= { cgspLinkTableEntry 45 } cgspLinkQ752T3E10L2 OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets(MSUs) discard due to Signalling link level 2 congestion Q752/3.10" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 18-19." ::= { cgspLinkTableEntry 46 } cgspLinkQ752T3E10L3 OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets(MSUs) discard due to Signalling link level 3 congestion Q752/3.10" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 19." ::= { cgspLinkTableEntry 47 } cgspLinkQ752T3E11L1 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "The number times this Signalling link entered congestion level 1 and packets were discarded. This measurement is specified in Q752/3.11" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 14." ::= { cgspLinkTableEntry 48 } cgspLinkQ752T3E11L2 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "The number times this Signalling link entered congestion level 2 and packets were discarded. This measurement is specified in Q752/3.11" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 15." ::= { cgspLinkTableEntry 49 } cgspLinkQ752T3E11L3 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "The number times this Signalling link entered congestion level 3 and packets were discarded. This measurement is specified in Q752/3.11" REFERENCE "ANSI GR-82-CORE 6.4.4 Link Measurements Item 16." ::= { cgspLinkTableEntry 50 } cgspLinkLocalPeerPort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-create STATUS current DESCRIPTION "When cgspLinkType is set to 'sctpIp' then this object contains the local port number used to create the association supporting this link. This object can be used to obtain information from the cgsp2LocalPeerTable and cgsp2LpIpAddrTable Tables in the CISCO-ITP-GSP2-MIB.my MIB." ::= { cgspLinkTableEntry 51 } cgspLinkRemotePeerPort OBJECT-TYPE SYNTAX InetPortNumber MAX-ACCESS read-create STATUS current DESCRIPTION "When cgspLinkType is set to 'sctpIp' then this object contains the remote port number used to create the association supporting this link. When cgspLinkType is not set to 'sctpIp' then no significance is to be placed on this value." ::= { cgspLinkTableEntry 52 } cgspLinkQosClass OBJECT-TYPE SYNTAX CItpTcQos MAX-ACCESS read-create STATUS current DESCRIPTION "When cgspLinkType is set to 'sctpIp' then this object contains the quality of service class to be assigned to packets sent on this association. When cgspLinkType is not set to 'sctpIp' then no significance is to be placed on this value." ::= { cgspLinkTableEntry 53 } cgspLinkDisplayName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..30)) MAX-ACCESS read-create STATUS current DESCRIPTION "A short identifier for each link linkset. This value can be set by system administrator or defaults to the linkset name and SLC formatted as an ASCII string." ::= { cgspLinkTableEntry 54 } cgspLinkDroppedPkts OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets that were dropped by this link." ::= { cgspLinkTableEntry 55 } cgspLinkTransmittedLSSUs OBJECT-TYPE SYNTAX Counter32 UNITS "LSSU" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Status Signal Units sent on this link." ::= { cgspLinkTableEntry 56 } cgspLinkReceivedLSSUs OBJECT-TYPE SYNTAX Counter32 UNITS "LSSU" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link Status Signal Units received on this link." ::= { cgspLinkTableEntry 57 } cgspLinkProtocolDetails OBJECT-TYPE SYNTAX BITS { tcbcBuffering(0), tcocBuffering(1), tlacAdjacentSpRestarting(2), tlacEmergencyCoInProgress(3), tlacChangebackInProgress(4), tlacChangeoverInProgress(5), tlacChangeoverFailed(6), tlacInhibitRetry(7), tlacManagementRequest(8), tlacSpRestarting(9), tsrcChangeOverComplete(10), tsrcAdjacentSpRestart(11), tlacLocalInhibit(12), tlacRemoteInhibit(13), tlacLocalBlocked(14), tlacRemoteBlocked(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object provide details on the protocol states for this link as follows. Changeback control(TCBC) 'tcbcBuffering': Changeback control is buffering data on this link. Changeover control(TCOC) 'tcocBuffering': Changeover control is buffering data on this link Link availability control(TLAC) 'tlacAdjacentSpRestarting': Adjacent Signalling point is restarting. 'tlacEmergencyCoInProgress': Emergency changeover is in progress on this link. 'tlacChangebackInProgress': Changeback is in progress on this link. 'tlacChangeoverInProgress': Changeover is in progress on this link. 'tlacChangeoverFailed': The last changeover operation failed on this link. 'tlacInhibitRetry': Inhibit command will be retried. 'tlacManagementRequest': Management request in progress for this link. 'tlacSpRestarting': Signalling point is in the process of a restart. 'tlacLocalInhibit': Link has been inhibited by a local management operation. 'tlacRemoteInhibit': Link has been inhibited by a remote management operation. 'tlacLocalBlocked': Link is blocked because of a local processor outage. 'tlacRemoteBlocked': Link is blocked because of a remote processor outage. Signalling routing control(TSRC) 'tsrcChangeOverComplete': Changeove request is complete. 'tsrcAdjacentSpRestart': Adjacent Signalling Point is restarting." ::= { cgspLinkTableEntry 58 } cgspLinkLsacState OBJECT-TYPE SYNTAX INTEGER { undefined(1), inactive(2), active(3), activatingRestoring(4), failed(5), actT17wait(6), actAnsiWaitDeloaded(7), actItuWaitStmReady(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Signalling link activity control state: 'undefined' - link is an undefined state 'inactive' - A Signalling link that is not in operation. 'active' - A Signalling link that is in operation. 'activatingRestoring' - A Signalling that is not operational and is being activated or restored. 'failed' - A Signalling link which is available (not blocked) is marked by level 3 as failed when a changeover order is received. 'actT17wait' - Link activation has failed. Link is placed into this state to wait for timer T17 to expire in order to avoid the oscillation of initial alignment failure and link restart. 'actAnsiWaitDeloaded - Waiting for change back acknowledgement (second attempt). 'actItuWaitStmReady' Wait for Signalling Traffic Management ready event." REFERENCE "Figure 37/Q.704 - Signalling link management. Signalling link activity control (LSAC)" ::= { cgspLinkTableEntry 59 } cgspLinkTsrcState OBJECT-TYPE SYNTAX INTEGER { undefined(1), idle(2), wait5(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Signalling traffic management routing control state: 'undefined' - link is an undefined state 'idle' - traffic management is idle 'wait5' - traffic management is active and in the sending status phase" REFERENCE "Figure 29/Q.704 - Signalling traffic management; Signalling routing control (TSRC)" ::= { cgspLinkTableEntry 60 } cgspLinkTcocState OBJECT-TYPE SYNTAX INTEGER { undefined(1), idle(2), wait2(3), waitForAck(4), retrieving(5), wait5(6), wait7(7), wait8(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Changeover control State: 'undefined' - Link is an undefined state. 'idle' - Link is available and idle. 'wait2' - Wait for MTP2 to initialize link. 'waitForAck' - Waiting for changeover acknowledgement. 'retrieving' - Packets are being retrieved from link. 'wait5' - Wait state when transitioning from idle state. 'wait7' - Delay to avoid message mis-sequencing on changeover 'wait8' - Wait state prior to processing changeover order or emergency changeover order events." REFERENCE "Figure 30/Q.704 - Signalling traffic management; changeover control (TCOC)" ::= { cgspLinkTableEntry 61 } cgspLinkTcocLocalBSNT OBJECT-TYPE SYNTAX CgspSequenceNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The local backward sequence number to be transmitted." ::= { cgspLinkTableEntry 62 } cgspLinkTcocRemoteBSNT OBJECT-TYPE SYNTAX CgspSequenceNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The remote backward sequence number to be transmitted." ::= { cgspLinkTableEntry 63 } cgspLinkTcbcState OBJECT-TYPE SYNTAX INTEGER { undefined(1), idle(2), firstAttempt(3), secondAttempt(4), timeControlledDiversion(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Changeback control State: 'undefined' - link is an undefined state. 'idle' - Link is available and idle. 'firstAttempt' - First attempt at changeback. 'secondAttempt' - Second attempt at changeback 'timeControlledDiversion' - Changeback using time controlled Diversion." ::= { cgspLinkTableEntry 64 } cgspLinkReceivedSIBs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of status indicator 'busy' link status signal units received on this link. The SIB indicates that level two is congested at the transmitting Signalling point." ::= { cgspLinkTableEntry 65 } cgspLinkTransmittedSIBs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of status indicator 'busy' link status signal units transmitted on this link. The SIB indicates that level two is congested at the transmitting Signalling point." ::= { cgspLinkTableEntry 66 } cgspLinkMtp2T01Counts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the alignment ready timer has expired on this link." ::= { cgspLinkTableEntry 67 } cgspLinkMtp2T02Counts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the not alignment ready timer has expired on this link." ::= { cgspLinkTableEntry 68 } cgspLinkMtp2T03Counts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the aligned timer has expired on this link." ::= { cgspLinkTableEntry 69 } cgspLinkMtp2T04Counts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the proving period timer has expired on this link." ::= { cgspLinkTableEntry 70 } cgspLinkMtp2T05Counts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the sending status indicator busy timer has expired on this link." ::= { cgspLinkTableEntry 71 } cgspLinkMtp2T06Counts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the remote congestion timer has expired on this link(Q752/1.6)." ::= { cgspLinkTableEntry 72 } cgspLinkMtp2T07Counts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the excessive delay of acknowledgement timer has expired on this link(Q752/1.4)." ::= { cgspLinkTableEntry 73 } cgspLinkOMAERMCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the Alignment Error Rate Monitor procedure was started on this link." ::= { cgspLinkTableEntry 74 } cgspLinkOMAERMFailCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the Alignment Error Rate Monitor procedure failed on this link." ::= { cgspLinkTableEntry 75 } cgspLinkOMSURMCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the Signal Unit Error Rate Monitor procedure was started on this link." ::= { cgspLinkTableEntry 76 } cgspLinkOMSURMFailCounts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the Signal Unit Error Rate Monitor procedure failed on this link." ::= { cgspLinkTableEntry 77 } cgspLinkPlanCapacityRcvd OBJECT-TYPE SYNTAX CgspLinkCapacity UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "An estimate of the number of bits per second that is expected to be received from this link. This object will be used in combination with cgspUtilSampleInterval, cgspUtilThreshold, cgspUtilThreshold and cgspLinkUtilThresholdRcvd to generate the ciscoGspLinkRcvdUtilChange notification." ::= { cgspLinkTableEntry 78 } cgspLinkUtilThresholdRcvd OBJECT-TYPE SYNTAX CgspPercentThreshold UNITS "percent" MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the threshold used to to generate the ciscoGspLinkRcvdUtilChange notification. The value of zero indicates the threshold has not been defined at the link level and the value from the cgspLinksetUtilThresholdRcvd or cgspUtilThreshold objects will be used to generate the ciscoGspLinkRcvdUtilChange notification." DEFVAL { 0 } ::= { cgspLinkTableEntry 79 } cgspLinkUtilizationRcvd OBJECT-TYPE SYNTAX CgspLinkUtilization UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the utilization of this link for traffic received on this link in the prior time period defined by the cgspUtilSampleInterval object." ::= { cgspLinkTableEntry 80 } cgspLinkUtilStateRcvd OBJECT-TYPE SYNTAX CgspLinkUtilizationState MAX-ACCESS read-only STATUS current DESCRIPTION "Link Utilization State for inbound traffic." ::= { cgspLinkTableEntry 81 } cgspLinkL2BytesRcvd OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the bytes received on the link including the additional bytes required by underlying protocols. This provides a transport independent mechanism for collection information on link utilization." ::= { cgspLinkTableEntry 82 } cgspLinkPlanCapacitySent OBJECT-TYPE SYNTAX CgspLinkCapacity UNITS "bits per second" MAX-ACCESS read-create STATUS current DESCRIPTION "An estimate of the number of bits per second that is expected to be sent on this link. This object will be used in combination with cgspUtilSampleInterval, cgspUtilThreshold and cgspLinkUtilThresholdRcvd to generate the ciscoGspLinkSentUtilChange notification." ::= { cgspLinkTableEntry 83 } cgspLinkUtilThresholdSent OBJECT-TYPE SYNTAX CgspPercentThreshold UNITS "percent" MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the threshold used to generate the ciscoGspLinkRcvdUtilChange notification. The value of zero indicates the threshold has not been defined at the link level and the value from the cgspLinksetUtilThresholdRcvd or cgspUtilThreshold objects will be used to generate the ciscoGspLinkRcvdUtilChange notification." DEFVAL { 0 } ::= { cgspLinkTableEntry 84 } cgspLinkUtilizationSent OBJECT-TYPE SYNTAX CgspLinkUtilization UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the utilization of this link for traffic sent on this link in the prior time period defined by the cgspUtilSampleInterval object." ::= { cgspLinkTableEntry 85 } cgspLinkUtilStateSent OBJECT-TYPE SYNTAX CgspLinkUtilizationState MAX-ACCESS read-only STATUS current DESCRIPTION "Link Utilization State for out bound traffic." ::= { cgspLinkTableEntry 86 } cgspLinkL2BytesSent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the bytes sent on the link including the additional bytes required by underlying protocols. This provides a transport independent mechanism for collection information on link utilization." ::= { cgspLinkTableEntry 87 } cgspLinkTestResult OBJECT-TYPE SYNTAX CgspLinkTestResults MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides information on result from signalling link test received on this link." ::= { cgspLinkTableEntry 88 } cgspLinkRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspLinkTable following the RowStatus textual convention." ::= { cgspLinkTableEntry 89 } cgspLinkSctpAssociationId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "If the link type specified by cgspLinkType is 'sctpIp', this is the association identifier defined in the Stream Control Transmission Protocol(SCTP) MIB. Where value greater than zero indicates a valid association. The zero value indicates an association does not exist for this link. This value will always be set to zero one when cgspLinkType is not equal to the 'sctpIp' value. This object replaces cgspLinkSctpAssociation and allows association identifiers to be larger than 65,535." ::= { cgspLinkTableEntry 90 } cgspLinkQ752T1E12 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of 'Signalling Link Restoration' events Q752/1.12." ::= { cgspLinkTableEntry 91 } cgspLinkQ752T1E12Errors OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of 'Signalling Link Restoration' error events related to Q752/1.12. i.e., the number of times the link restoration was attempted and the link was not recovered." ::= { cgspLinkTableEntry 92 } cgspLinkQ752T2E11 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of 'remote processor recovery' events Q752/2.11. The standard only requires that events are issued." ::= { cgspLinkTableEntry 93 } cgspLinkQ752T2E17 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of local uninhibition Q752/2.17. The standard only requires that events are issued." ::= { cgspLinkTableEntry 94 } cgspLinkQ752T2E19 OBJECT-TYPE SYNTAX Counter32 UNITS "occurrences" MAX-ACCESS read-only STATUS current DESCRIPTION "Count of remote uninhibition Q752/2.19. The standard only requires that events are issued." ::= { cgspLinkTableEntry 95 } cgspLinkRxCongestionState OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "The Signalling link Received Side congestion status of this link. 0 abate, 1 onset is the received side congestion level" ::= { cgspLinkTableEntry 96 } -- ************************************************************* -- * * -- * Link Timer Table * -- * * -- ************************************************************* cgspLinkTimerTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspLinkTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the timer used to configure timer values specific to a particular Link. Entries are added to this table via cgspLinkTimerRowStatus in accordance with the RowStatus convention." ::= { cgspLink 2 } cgspLinkTimerTableEntry OBJECT-TYPE SYNTAX CgspLinkTimerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to configure all MTP3 timer values that apply to links. The values apply to a particular link." INDEX { cgspInstNetwork, cgspLinksetName, cgspLinkSlc, cgspLinkTimerNumber } ::= { cgspLinkTimerTable 1 } CgspLinkTimerTableEntry ::= SEQUENCE { cgspLinkTimerNumber CgspTimerNumbers, cgspLinkTimerValue CgspTimerValue, cgspLinkTimerRowStatus RowStatus } cgspLinkTimerNumber OBJECT-TYPE SYNTAX CgspTimerNumbers MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into table containing timer information." ::= { cgspLinkTimerTableEntry 1 } cgspLinkTimerValue OBJECT-TYPE SYNTAX CgspTimerValue UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Value of timer selected by cgspLinkTimerNumber object." ::= { cgspLinkTimerTableEntry 2 } cgspLinkTimerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspLinkTimerTable following the RowStatus textual convention." ::= { cgspLinkTimerTableEntry 3 } -- ************************************************************* -- * * -- * Link Remote Ip Address Table * -- * * -- ************************************************************* cgspLinkRemoteIpAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspLinkRemoteIpAddrTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains the remote IP addresses used to configure a particular Link. Entries are added to this table via cgspLinkRemoteIpAddrRowStatus in accordance with the RowStatus convention." ::= { cgspLink 3 } cgspLinkRemoteIpAddrTableEntry OBJECT-TYPE SYNTAX CgspLinkRemoteIpAddrTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of remote IP addresses per Link." INDEX { cgspInstNetwork, cgspLinksetName, cgspLinkSlc, cgspLinkRemoteIpAddrNumber } ::= { cgspLinkRemoteIpAddrTable 1 } CgspLinkRemoteIpAddrTableEntry ::= SEQUENCE { cgspLinkRemoteIpAddrNumber Unsigned32, cgspLinkRemoteIpAddrType InetAddressType, cgspLinkRemoteIpAddress InetAddress, cgspLinkRemoteIpAddrRowStatus RowStatus } cgspLinkRemoteIpAddrNumber OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies the index for the IP addresses in the remote IP Address table" ::= { cgspLinkRemoteIpAddrTableEntry 1 } cgspLinkRemoteIpAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "This object contains the type of the local IP address used to create an association." ::= { cgspLinkRemoteIpAddrTableEntry 2 } cgspLinkRemoteIpAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This object contains the remote IP address used to create the association with the partner of this association." ::= { cgspLinkRemoteIpAddrTableEntry 3 } cgspLinkRemoteIpAddrRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The object is used by a management station to create or delete the row entry in cgspLinkRemoteIpAddrTable following the RowStatus textual convention." ::= { cgspLinkRemoteIpAddrTableEntry 4 } -- ************************************************************* -- * * -- * Link Utilization table * -- * * -- ************************************************************* cgspLinkUtilTable OBJECT-TYPE SYNTAX SEQUENCE OF CgspLinkUtilTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains a history of the cgspLinkUtilizationRcvd and cgspLinkUtilizationRcvd objects. In order to properly manage network capacity it is necessary to collect utilization information during short interval. These intervals are less than 5 minutes and can be as low as 1 minute. The number of links supported by a signalling point prevent polling each signalling point to collect information. This table is provided to allow an NMS to collect the information during a normal poll cycle." ::= { cgspLink 4 } cgspLinkUtilTableEntry OBJECT-TYPE SYNTAX CgspLinkUtilTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of entries used to store a history link utilization values. Values from cgspLinkUtilizationRcvd and cgspLinkUtilizationSent objects are saved in cgspLinkUtilRcvd and cgspLinkUtilSent." INDEX { cgspInstNetwork, cgspLinksetName, cgspLinkSlc, cgspLinkUtilIndex } ::= { cgspLinkUtilTable 1 } CgspLinkUtilTableEntry ::= SEQUENCE { cgspLinkUtilIndex Unsigned32, cgspLinkUtilRcvd CgspLinkUtilization, cgspLinkUtilSent CgspLinkUtilization, cgspLinkUtilEndTimestamp TimeStamp } cgspLinkUtilIndex OBJECT-TYPE SYNTAX Unsigned32 (1..60) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index used to access historical link utilization information. Entry one corresponds to the most recent utilization window for the length of time specified by the cgspUtilSampleInterval object. Example of utilization history using default values. Current Time: 10:42 am Sample Interval: 300 seconds cgspLinkUtilIndex [1] Window from 10:36-10:41 [2] Window from 10:31-10:36 [3] Window from 10:26-10:31 . . [n] The index ranges from one to a maximum of sixty entries. The actual number of entries will depend on the implementation and available resources." ::= { cgspLinkUtilTableEntry 1 } cgspLinkUtilRcvd OBJECT-TYPE SYNTAX CgspLinkUtilization UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the utilization of this link for traffic received on this link in the time period defined by the cgspUtilSampleInterval object." ::= { cgspLinkUtilTableEntry 2 } cgspLinkUtilSent OBJECT-TYPE SYNTAX CgspLinkUtilization UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the utilization of this link for traffic transmitted on this link in the time period defined by the cgspUtilSampleInterval object." ::= { cgspLinkUtilTableEntry 3 } cgspLinkUtilEndTimestamp OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This timestamp indicates when time period ended for this sample." ::= { cgspLinkUtilTableEntry 4 } -- ************************************************************* -- * * -- * GSP - Notification Enable Objects * -- * * -- ************************************************************* cgspLsStateChangeNotifEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The signalling point linkset notification truth value. 'true' Indicates that ciscoGspLinksetStateChange notification is to be generated when the state changes. That is, the notification generation is enabled. 'false' Indicates that ciscoGspLinksetStateChange notification generation is disabled." DEFVAL { false } ::= { cgspNotificationsEnable 1 } cgspLnkStateChangeNotifEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The signalling point link notification truth value. 'true' Indicates that ciscoGspLinkStateChange notification is to be generated when the state changes. That is, the notification generation is enabled. 'false' Indicates that ciscoGspLinkStateChange notification generation is disabled." DEFVAL { false } ::= { cgspNotificationsEnable 2 } cgspCongestionNotifEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The signalling point congestion notification truth value. 'true' Indicates that ciscoGspCongestionChange and ciscoGspRxCongestionChange notification is to be generated when the state changes. That is, the notification generation is enabled. 'false' Indicates that ciscoGspCongestionChange and ciscoGspRxCongestionChange notification generation is disabled." DEFVAL { false } ::= { cgspNotificationsEnable 3 } cgspLinkUtilNotifEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The signalling point link utilization notification truth value. 'true' Indicates that the notification of link utilization has been enabled. That is, the notification generation is enabled. 'false' Indicates that the notification link utilization has been disabled." DEFVAL { false } ::= { cgspNotificationsEnable 4 } cgspIsolationNotifEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The isolation notification truth value. 'true' Indicates that the notification of isolation has been enabled. That is, the notification generation is enabled. 'false' Indicates that the notification of isolation has been disabled." DEFVAL { false } ::= { cgspNotificationsEnable 5 } cgspUPUNotifEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "A control to enable or disable both ciscoGspUPUReceived and ciscoGspUPUTransmitted notifications as follows: 'true' Indicates that the ciscoGspUPUReceived and ciscoGspUPUTransmitted notification generation is enabled. 'false' Indicates that ciscoGspUPUReceived and ciscoGspUPUTransmitted notification generation is disabled." DEFVAL { false } ::= { cgspNotificationsEnable 6 } -- ************************************************************* -- * * -- * Notifications Information * -- * * -- ************************************************************* cgspUPUIntervalDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Duration elapsed since the start of the cgspUPUNotifWindowTime interval. This duration value can range from 0 upto cgspUPUNotifWindowTime. For the notifications generated at the end of the interval, this value will be equal to cgspUPUNotifWindowTime." ::= { cgspNotificationsInfo 1 } cgspIntervalUPUs OBJECT-TYPE SYNTAX Unsigned32 UNITS "MSUs" MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Number of UPU MSUs received or transmitted during this specific cgspUPUIntervalDuration interval." ::= { cgspNotificationsInfo 2 } -- ************************************************************* -- * * -- * Notifications * -- * * -- ************************************************************* ciscoGspLinksetStateChange NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspLinksetDisplayName, cgspLinksetSourceDisplayPC, cgspLinksetAdjacentDisplayPC, cgspLinksetState } STATUS current DESCRIPTION "The notification generated when a linkset changes to a new state. The value of cgspLinksetState indicates the new state." ::= { ciscoGspMIBNotifs 1 } ciscoGspLinkStateChange NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspLinksetSourceDisplayPC, cgspLinksetAdjacentDisplayPC, cgspLinkDisplayName, cgspLinkState, cgspLinkReason, cgspLinkTestResult } STATUS current DESCRIPTION "The notification generated when a link changes to a new state. The value of cgspLinkState indicates the new state." ::= { ciscoGspMIBNotifs 2 } ciscoGspCongestionChange NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspLinksetSourceDisplayPC, cgspLinksetAdjacentDisplayPC, cgspLinkDisplayName, cgspLinkCongestionState } STATUS current DESCRIPTION "The notification generated when a link changes to a new congestion level as specified by cgspLinkCongestionState object for Transmission Side congestion." ::= { ciscoGspMIBNotifs 3 } ciscoGspLinkRcvdUtilChange NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspLinksetSourceDisplayPC, cgspLinksetAdjacentDisplayPC, cgspLinkDisplayName, cgspLinkUtilStateRcvd, cgspLinkUtilizationRcvd } STATUS current DESCRIPTION "The notification provide is generated when the cgspLinkUtilStateRcvd changes states." ::= { ciscoGspMIBNotifs 4 } ciscoGspLinkSentUtilChange NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspLinksetSourceDisplayPC, cgspLinksetAdjacentDisplayPC, cgspLinkDisplayName, cgspLinkUtilStateSent, cgspLinkUtilizationSent } STATUS current DESCRIPTION "The notification provide is generated when the cgspLinkUtilStateSent changes states." ::= { ciscoGspMIBNotifs 5 } ciscoGspIsolation NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspInstDisplayName, cgspInstDescription } STATUS current DESCRIPTION "This notification indicates the instance specified by cgspInstDisplayName and cgspInstDescription has become isolated. All linkset used to connect MTP3 node (instance) are unavailable. Isolation is ended when any linkset supported by this instance reaches the active state." ::= { ciscoGspMIBNotifs 6 } ciscoGspUPUReceived NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspInstUserPartDisplay, cgspUPUIntervalDuration, cgspIntervalUPUs } STATUS current DESCRIPTION "The notification is generated when an UPU MSU is received from a remote signalling point, for a specific instance and user part for the first time in the configured cgspUPUNotifWindowTime. For cases when there is a non-zero number of UPU MSUs received, this notification will be sent at the end of the cgspUPUNotifWindowTime interval, with cgspIntervalUPUs indicating the total count of UPU MSUs received for that specific instance and user part during the entire cgspUPUNotifWindowTime interval Q752/5.6." ::= { ciscoGspMIBNotifs 8 } ciscoGspUPUTransmitted NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspInstUserPartDisplay, cgspUPUIntervalDuration, cgspIntervalUPUs } STATUS current DESCRIPTION "The notification is generated when an UPU MSU is transmitted to a remote signalling point, for a specific instance and user part for the first time in the configured cgspUPUNotifWindowTime. For cases when there is a non-zero number of UPU MSUs received, this notification will be sent at the end of the cgspUPUNotifWindowTime interval, with cgspIntervalUPUs indicating the total count of UPU MSUs transmitted for that specific instance and user part during the entire cgspUPUNotifWindowTime interval Q752/5.7." ::= { ciscoGspMIBNotifs 9 } ciscoGspRxCongestionChange NOTIFICATION-TYPE OBJECTS { cgspEventSequenceNumber, cgspCLLICode, cgspLinksetSourceDisplayPC, cgspLinksetAdjacentDisplayPC, cgspLinkDisplayName, cgspLinkRxCongestionState } STATUS current DESCRIPTION "The notification generated when a link changes to a new congestion level as specified by cgspLinkRxCongestionstate object for Received side congestion" ::= { ciscoGspMIBNotifs 10 } -- Conformance Information ciscoGspMIBCompliances OBJECT IDENTIFIER ::= { ciscoGspMIBConform 1 } ciscoGspMIBGroups OBJECT IDENTIFIER ::= { ciscoGspMIBConform 2 } -- Compliance ciscoGspMIBCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement the CISCO-ITP-GSP-MIB" MODULE -- this module MANDATORY-GROUPS { ciscoGspScalarsGroup, ciscoGspProfileGroup, ciscoGspInstanceGroup, ciscoGspInstTimerGroup, ciscoGspPointCodeGroup, ciscoGspLinksetGroup, ciscoGspLinksetTimerGroup, ciscoGspLinkGroup, ciscoGspLinkTimerGroup, ciscoGspLinkRemoteIpGroup, ciscoGspLinkUtilGroup, ciscoGspNotificationsEnableGroup, ciscoGspNotificationsGroup } OBJECT cgspCLLICode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilSampleInterval MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilThreshold MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilAbateDelta MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPlanCapacityDefault MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2BundleTimer MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2SendQueueDepth MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstNetworkIndicator MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTFR MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstCongestionsLevels MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstFastRestart MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDistSccpUnseq MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstSummaryRoutingException MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRouteTableName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetSourcePointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAdjacentPointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetInboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetOutboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingMtp3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingGtt MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetActPriority MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsEnable MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsShift MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetProfileName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkifIndex MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkXmitQueueDepthHigh MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkSigLinkTest MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkLocalPeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemotePeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkQosClass MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacityRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacitySent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdSent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddress MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." ::= { ciscoGspMIBCompliances 1 } ciscoGspMIBComplianceRev1 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement the CISCO-ITP-GSP-MIB" MODULE -- this module MANDATORY-GROUPS { ciscoGspScalarsGroup, ciscoGspProfileGroup, ciscoGspInstanceGroup, ciscoGspInstTimerGroup, ciscoGspPointCodeGroup, ciscoGspLinksetGroup, ciscoGspLinksetTimerGroup, ciscoGspLinkTimerGroup, ciscoGspLinkRemoteIpGroup, ciscoGspLinkUtilGroup, ciscoGspNotificationsEnableGroup, ciscoGspNotificationsGroup, ciscoGspLinkGroupRev1 } OBJECT cgspCLLICode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilSampleInterval MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilThreshold MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilAbateDelta MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPlanCapacityDefault MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2BundleTimer MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2SendQueueDepth MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstNetworkIndicator MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTFR MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstCongestionsLevels MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstFastRestart MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDistSccpUnseq MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstSummaryRoutingException MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRouteTableName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetSourcePointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAdjacentPointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetInboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetOutboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingMtp3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingGtt MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetActPriority MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsEnable MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsShift MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetProfileName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkifIndex MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkXmitQueueDepthHigh MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkSigLinkTest MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkLocalPeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemotePeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkQosClass MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacityRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacitySent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdSent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddress MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." ::= { ciscoGspMIBCompliances 2 } ciscoGspMIBComplianceRev2 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement the CISCO-ITP-GSP-MIB" MODULE -- this module MANDATORY-GROUPS { ciscoGspScalarsGroup, ciscoGspProfileGroup, ciscoGspInstanceGroup, ciscoGspInstTimerGroup, ciscoGspPointCodeGroup, ciscoGspLinksetGroup, ciscoGspLinksetTimerGroup, ciscoGspLinkTimerGroup, ciscoGspLinkRemoteIpGroup, ciscoGspLinkUtilGroup, ciscoGspNotificationsEnableGroup, ciscoGspNotificationsGroup, ciscoGspLinkGroupRev1, ciscoGspNotificationsEnableGroupSup1, ciscoGspNotificationsGroupSup1 } OBJECT cgspCLLICode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilSampleInterval MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilThreshold MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilAbateDelta MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPlanCapacityDefault MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2BundleTimer MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2SendQueueDepth MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstNetworkIndicator MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTFR MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstCongestionsLevels MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstFastRestart MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDistSccpUnseq MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstSummaryRoutingException MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRouteTableName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetSourcePointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAdjacentPointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetInboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetOutboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingMtp3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingGtt MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetActPriority MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsEnable MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsShift MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetProfileName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkifIndex MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkXmitQueueDepthHigh MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkSigLinkTest MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkLocalPeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemotePeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkQosClass MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacityRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacitySent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdSent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddress MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." ::= { ciscoGspMIBCompliances 3 } ciscoGspMIBComplianceRev3 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement the CISCO-ITP-GSP-MIB" MODULE -- this module MANDATORY-GROUPS { ciscoGspScalarsGroup, ciscoGspProfileGroup, ciscoGspInstanceGroup, ciscoGspInstTimerGroup, ciscoGspPointCodeGroup, ciscoGspLinksetGroup, ciscoGspLinksetTimerGroup, ciscoGspLinkTimerGroup, ciscoGspLinkRemoteIpGroup, ciscoGspLinkUtilGroup, ciscoGspNotificationsEnableGroup, ciscoGspNotificationsGroup, ciscoGspLinkGroupRev1, ciscoGspNotificationsEnableGroupSup1, ciscoGspNotificationsGroupSup1, ciscoGspLinkGroupSup1, ciscoGspScalarsGroupSup1, ciscoGspInstUPUGroup, ciscoGspNotificationsInfoGroup, ciscoGspNotificationsEnableGroupSup2, ciscoGspNotificationsGroupSup2 } OBJECT cgspCLLICode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilSampleInterval MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilThreshold MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilAbateDelta MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPlanCapacityDefault MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2BundleTimer MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2SendQueueDepth MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstNetworkIndicator MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTFR MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstCongestionsLevels MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstFastRestart MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDistSccpUnseq MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstSummaryRoutingException MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRouteTableName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetSourcePointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAdjacentPointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetInboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetOutboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingMtp3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingGtt MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetActPriority MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsEnable MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsShift MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetProfileName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkifIndex MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkXmitQueueDepthHigh MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkSigLinkTest MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkLocalPeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemotePeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkQosClass MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacityRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacitySent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdSent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddress MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." ::= { ciscoGspMIBCompliances 4 } ciscoGspMIBComplianceRev4 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement the CISCO-ITP-GSP-MIB" MODULE -- this module MANDATORY-GROUPS { ciscoGspScalarsGroup, ciscoGspProfileGroup, ciscoGspInstanceGroup, ciscoGspInstTimerGroup, ciscoGspPointCodeGroup, ciscoGspLinksetGroup, ciscoGspLinksetTimerGroup, ciscoGspLinkTimerGroup, ciscoGspLinkRemoteIpGroup, ciscoGspLinkUtilGroup, ciscoGspNotificationsEnableGroup, ciscoGspNotificationsGroup, ciscoGspLinkGroupRev1, ciscoGspNotificationsEnableGroupSup1, ciscoGspNotificationsGroupSup1, ciscoGspLinkGroupSup1, ciscoGspScalarsGroupSup1, ciscoGspInstUPUGroup, ciscoGspNotificationsInfoGroup, ciscoGspNotificationsEnableGroupSup2, ciscoGspNotificationsGroupSup2, ciscoGspInstSccpWrrGroup } OBJECT cgspCLLICode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilSampleInterval MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilThreshold MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspUtilAbateDelta MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPlanCapacityDefault MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2BundleTimer MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileMtp2SendQueueDepth MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspProfileTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstNetworkIndicator MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTFR MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstCongestionsLevels MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstFastRestart MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstDistSccpUnseq MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstSummaryRoutingException MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRouteTableName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspInstTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspPointCodeRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetSourcePointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAdjacentPointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetInboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetOutboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingMtp3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingGtt MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetActPriority MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsEnable MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsShift MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetProfileName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkifIndex MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkXmitQueueDepthHigh MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkSigLinkTest MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkLocalPeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemotePeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkQosClass MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacityRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacitySent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdSent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddress MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." ::= { ciscoGspMIBCompliances 5 } ciscoGspMIBComplianceRev5 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the CISCO-ITP-GSP-MIB" MODULE -- this module MANDATORY-GROUPS { ciscoGspScalarsGroup, ciscoGspProfileGroup, ciscoGspInstanceGroup, ciscoGspInstTimerGroup, ciscoGspPointCodeGroup, ciscoGspLinksetGroup, ciscoGspLinksetTimerGroup, ciscoGspLinkTimerGroup, ciscoGspLinkRemoteIpGroup, ciscoGspLinkUtilGroup, ciscoGspNotificationsEnableGroup, ciscoGspNotificationsGroup, ciscoGspLinkGroupRev1, ciscoGspNotificationsEnableGroupSup1, ciscoGspNotificationsGroupSup1, ciscoGspLinkGroupSup1, ciscoGspScalarsGroupSup1, ciscoGspInstUPUGroup, ciscoGspNotificationsInfoGroup, ciscoGspNotificationsEnableGroupSup2, ciscoGspNotificationsGroupSup2, ciscoGspInstSccpWrrGroup, ciscoGspLinkTableEntryGroupSup1, ciscoGspNotificationsGroupSup3 } OBJECT cgspCLLICode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspUtilSampleInterval MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspUtilThreshold MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspUtilAbateDelta MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspPlanCapacityDefault MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspProfileVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspProfileMtp2BundleTimer MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspProfileMtp2SendQueueDepth MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspProfileRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspProfileTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspProfileTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstNetworkIndicator MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstVariant MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstTFR MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstCongestionsLevels MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstFastRestart MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstDistSccpUnseq MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstSummaryRoutingException MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstRouteTableName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspInstTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspPointCodeType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspPointCodeRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required" OBJECT cgspLinksetSourcePointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAdjacentPointCode MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetInboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetOutboundAcl MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingMtp3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetAccountingGtt MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetActPriority MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsEnable MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRotateSlsShift MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetProfileName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinksetDescription MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkifIndex MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkXmitQueueDepthHigh MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionAbate3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset1 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset2 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkCongestionOnset3 MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkSigLinkTest MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkLocalPeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemotePeerPort MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkQosClass MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkDisplayName MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacityRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdRcvd MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkPlanCapacitySent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkUtilThresholdSent MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerValue MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkTimerRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrType MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddress MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRemoteIpAddrRowStatus MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." OBJECT cgspLinkRxCongestionState MIN-ACCESS read-only DESCRIPTION "Create/Write access is not required." ::= { ciscoGspMIBCompliances 6 } -- Units of Conformance ciscoGspScalarsGroup OBJECT-GROUP OBJECTS { cgspCLLICode, cgspUtilSampleInterval, cgspUtilThreshold, cgspUtilAbateDelta, cgspPlanCapacityDefault, cgspEventSequenceNumber } STATUS current DESCRIPTION "Scalars Group for Gateway Signalling Point." ::= { ciscoGspMIBGroups 1 } ciscoGspProfileGroup OBJECT-GROUP OBJECTS { cgspProfileVariant, cgspProfileMtp2BundleTimer, cgspProfileMtp2SendQueueDepth, cgspProfileRowStatus, cgspProfileTimerValue, cgspProfileTimerRowStatus } STATUS current DESCRIPTION "Profile Group for Gateway Signalling Point." ::= { ciscoGspMIBGroups 2 } ciscoGspInstanceGroup OBJECT-GROUP OBJECTS { cgspInstNetworkIndicator, cgspInstVariant, cgspInstDisplayName, cgspInstDescription, cgspInstTFR, cgspInstCongestionsLevels, cgspInstFastRestart, cgspInstDistSccpUnseq, cgspInstSummaryRoutingException, cgspInstNumber, cgspInstRouteTableName, cgspInstRowStatus } STATUS current DESCRIPTION "Instance of Signalling Point." ::= { ciscoGspMIBGroups 3 } ciscoGspInstTimerGroup OBJECT-GROUP OBJECTS { cgspInstTimerValue, cgspInstTimerRowStatus } STATUS current DESCRIPTION "Timers defined for each Instance of Signalling Point." ::= { ciscoGspMIBGroups 4 } ciscoGspPointCodeGroup OBJECT-GROUP OBJECTS { cgspPointCodeType, cgspPointCodeDisplay, cgspPointCodeRowStatus } STATUS current DESCRIPTION "Pointcode defined for each Instance of Signalling Point." ::= { ciscoGspMIBGroups 5 } ciscoGspLinksetGroup OBJECT-GROUP OBJECTS { cgspLinksetSourcePointCode, cgspLinksetSourceDisplayPC, cgspLinksetAdjacentPointCode, cgspLinksetAdjacentDisplayPC, cgspLinksetState, cgspLinksetInboundAcl, cgspLinksetOutboundAcl, cgspLinksetAccountingMtp3, cgspLinksetAccountingGtt, cgspLinksetNumLinks, cgspLinksetDurationInService, cgspLinksetDurationOutService, cgspLinksetActPriority, cgspLinksetDisplayName, cgspLinksetDescription, cgspLinksetRotateSlsEnable, cgspLinksetRotateSlsShift, cgspLinksetProfileName, cgspLinksetAdjacentInst, cgspLinksetRowStatus } STATUS current DESCRIPTION "linkset objects ." ::= { ciscoGspMIBGroups 6 } ciscoGspLinksetTimerGroup OBJECT-GROUP OBJECTS { cgspLinksetTimerValue, cgspLinksetTimerRowStatus } STATUS current DESCRIPTION "Timers defined for each Linkset." ::= { ciscoGspMIBGroups 7 } ciscoGspLinkGroup OBJECT-GROUP OBJECTS { cgspLinkDescription, cgspLinkState, cgspLinkReason, cgspLinkType, cgspLinkifIndex, cgspLinkSctpAssociation, cgspLinkXmitQueueDepth, cgspLinkXmitQueueDepthHigh, cgspLinkXmitQueueDepthHighRT, cgspLinkCongestionState, cgspLinkCongestionAbate1, cgspLinkCongestionAbate2, cgspLinkCongestionAbate3, cgspLinkCongestionOnset1, cgspLinkCongestionOnset2, cgspLinkCongestionOnset3, cgspLinkSigLinkTest, cgspLinkQ752T1E1, cgspLinkQ752T1E2, cgspLinkQ752T1E3, cgspLinkQ752T1E5, cgspLinkQ752T1E7, cgspLinkQ752T1E8, cgspLinkQ752T1E9, cgspLinkQ752T1E10, cgspLinkQ752T1E11, cgspLinkQ752T2E1, cgspLinkQ752T2E5, cgspLinkQ752T2E6, cgspLinkQ752T2E7, cgspLinkQ752T2E9, cgspLinkQ752T2E10, cgspLinkQ752T2E15, cgspLinkQ752T2E16, cgspLinkQ752T2E18, cgspLinkQ752T3E1, cgspLinkQ752T3E2Packets, cgspLinkQ752T3E2Bytes, cgspLinkQ752T3E3, cgspLinkQ752T3E4, cgspLinkQ752T3E5, cgspLinkQ752T3E6, cgspLinkQ752T3E7, cgspLinkQ752T3E10L1, cgspLinkQ752T3E10L2, cgspLinkQ752T3E10L3, cgspLinkQ752T3E11L1, cgspLinkQ752T3E11L2, cgspLinkQ752T3E11L3, cgspLinkLocalPeerPort, cgspLinkRemotePeerPort, cgspLinkQosClass, cgspLinkDisplayName, cgspLinkDroppedPkts, cgspLinkTransmittedLSSUs, cgspLinkReceivedLSSUs, cgspLinkProtocolDetails, cgspLinkLsacState, cgspLinkTsrcState, cgspLinkTcocState, cgspLinkTcocLocalBSNT, cgspLinkTcocRemoteBSNT, cgspLinkTcbcState, cgspLinkReceivedSIBs, cgspLinkTransmittedSIBs, cgspLinkMtp2T01Counts, cgspLinkMtp2T02Counts, cgspLinkMtp2T03Counts, cgspLinkMtp2T04Counts, cgspLinkMtp2T05Counts, cgspLinkMtp2T06Counts, cgspLinkMtp2T07Counts, cgspLinkOMAERMCounts, cgspLinkOMAERMFailCounts, cgspLinkOMSURMCounts, cgspLinkOMSURMFailCounts, cgspLinkPlanCapacityRcvd, cgspLinkUtilThresholdRcvd, cgspLinkUtilizationRcvd, cgspLinkUtilStateRcvd, cgspLinkL2BytesRcvd, cgspLinkPlanCapacitySent, cgspLinkUtilThresholdSent, cgspLinkUtilizationSent, cgspLinkUtilStateSent, cgspLinkL2BytesSent, cgspLinkTestResult, cgspLinkRowStatus } STATUS deprecated DESCRIPTION "SP link objects." ::= { ciscoGspMIBGroups 8 } ciscoGspLinkTimerGroup OBJECT-GROUP OBJECTS { cgspLinkTimerValue, cgspLinkTimerRowStatus } STATUS current DESCRIPTION "Timers defined for each Link." ::= { ciscoGspMIBGroups 9 } ciscoGspLinkRemoteIpGroup OBJECT-GROUP OBJECTS { cgspLinkRemoteIpAddrType, cgspLinkRemoteIpAddress, cgspLinkRemoteIpAddrRowStatus } STATUS current DESCRIPTION "Remote IP addresses for each Link." ::= { ciscoGspMIBGroups 10 } ciscoGspLinkUtilGroup OBJECT-GROUP OBJECTS { cgspLinkUtilRcvd, cgspLinkUtilSent, cgspLinkUtilEndTimestamp } STATUS current DESCRIPTION "Utilization history for each Link." ::= { ciscoGspMIBGroups 11 } ciscoGspNotificationsEnableGroup OBJECT-GROUP OBJECTS { cgspLsStateChangeNotifEnabled, cgspLnkStateChangeNotifEnabled, cgspCongestionNotifEnabled, cgspLinkUtilNotifEnabled } STATUS current DESCRIPTION "SP enable notification objects." ::= { ciscoGspMIBGroups 12 } ciscoGspNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { ciscoGspLinksetStateChange, ciscoGspLinkStateChange, ciscoGspCongestionChange, ciscoGspLinkRcvdUtilChange, ciscoGspLinkSentUtilChange } STATUS current DESCRIPTION "SP notifications." ::= { ciscoGspMIBGroups 13 } ciscoGspLinkGroupRev1 OBJECT-GROUP OBJECTS { cgspLinkDescription, cgspLinkState, cgspLinkReason, cgspLinkType, cgspLinkifIndex, cgspLinkXmitQueueDepth, cgspLinkXmitQueueDepthHigh, cgspLinkXmitQueueDepthHighRT, cgspLinkCongestionState, cgspLinkCongestionAbate1, cgspLinkCongestionAbate2, cgspLinkCongestionAbate3, cgspLinkCongestionOnset1, cgspLinkCongestionOnset2, cgspLinkCongestionOnset3, cgspLinkSigLinkTest, cgspLinkQ752T1E1, cgspLinkQ752T1E2, cgspLinkQ752T1E3, cgspLinkQ752T1E5, cgspLinkQ752T1E7, cgspLinkQ752T1E8, cgspLinkQ752T1E9, cgspLinkQ752T1E10, cgspLinkQ752T1E11, cgspLinkQ752T2E1, cgspLinkQ752T2E5, cgspLinkQ752T2E6, cgspLinkQ752T2E7, cgspLinkQ752T2E9, cgspLinkQ752T2E10, cgspLinkQ752T2E15, cgspLinkQ752T2E16, cgspLinkQ752T2E18, cgspLinkQ752T3E1, cgspLinkQ752T3E2Packets, cgspLinkQ752T3E2Bytes, cgspLinkQ752T3E3, cgspLinkQ752T3E4, cgspLinkQ752T3E5, cgspLinkQ752T3E6, cgspLinkQ752T3E7, cgspLinkQ752T3E10L1, cgspLinkQ752T3E10L2, cgspLinkQ752T3E10L3, cgspLinkQ752T3E11L1, cgspLinkQ752T3E11L2, cgspLinkQ752T3E11L3, cgspLinkLocalPeerPort, cgspLinkRemotePeerPort, cgspLinkQosClass, cgspLinkDisplayName, cgspLinkDroppedPkts, cgspLinkTransmittedLSSUs, cgspLinkReceivedLSSUs, cgspLinkProtocolDetails, cgspLinkLsacState, cgspLinkTsrcState, cgspLinkTcocState, cgspLinkTcocLocalBSNT, cgspLinkTcocRemoteBSNT, cgspLinkTcbcState, cgspLinkReceivedSIBs, cgspLinkTransmittedSIBs, cgspLinkMtp2T01Counts, cgspLinkMtp2T02Counts, cgspLinkMtp2T03Counts, cgspLinkMtp2T04Counts, cgspLinkMtp2T05Counts, cgspLinkMtp2T06Counts, cgspLinkMtp2T07Counts, cgspLinkOMAERMCounts, cgspLinkOMAERMFailCounts, cgspLinkOMSURMCounts, cgspLinkOMSURMFailCounts, cgspLinkPlanCapacityRcvd, cgspLinkUtilThresholdRcvd, cgspLinkUtilizationRcvd, cgspLinkUtilStateRcvd, cgspLinkL2BytesRcvd, cgspLinkPlanCapacitySent, cgspLinkUtilThresholdSent, cgspLinkUtilizationSent, cgspLinkUtilStateSent, cgspLinkL2BytesSent, cgspLinkTestResult, cgspLinkRowStatus, cgspLinkSctpAssociationId } STATUS current DESCRIPTION "SP link objects." ::= { ciscoGspMIBGroups 14 } ciscoGspNotificationsEnableGroupSup1 OBJECT-GROUP OBJECTS { cgspIsolationNotifEnabled } STATUS current DESCRIPTION "Isolation notification enable." ::= { ciscoGspMIBGroups 15 } ciscoGspNotificationsGroupSup1 NOTIFICATION-GROUP NOTIFICATIONS { ciscoGspIsolation } STATUS current DESCRIPTION "Isolation notification." ::= { ciscoGspMIBGroups 16 } ciscoGspLinkGroupSup1 OBJECT-GROUP OBJECTS { cgspLinkQ752T1E12, cgspLinkQ752T1E12Errors, cgspLinkQ752T2E11, cgspLinkQ752T2E17, cgspLinkQ752T2E19 } STATUS current DESCRIPTION "Additional Link statistics." ::= { ciscoGspMIBGroups 17 } ciscoGspScalarsGroupSup1 OBJECT-GROUP OBJECTS { cgspUPUNotifWindowTime } STATUS current DESCRIPTION "Scalar Group supplements." ::= { ciscoGspMIBGroups 18 } ciscoGspInstUPUGroup OBJECT-GROUP OBJECTS { cgspInstSIUPUReceived, cgspInstSIUPUTransmitted, cgspInstUserPartDisplay } STATUS current DESCRIPTION "SS7 Destination and Service Indicator group." ::= { ciscoGspMIBGroups 20 } ciscoGspNotificationsInfoGroup OBJECT-GROUP OBJECTS { cgspUPUIntervalDuration, cgspIntervalUPUs } STATUS current DESCRIPTION "Notifications Info Group." ::= { ciscoGspMIBGroups 21 } ciscoGspNotificationsEnableGroupSup2 OBJECT-GROUP OBJECTS { cgspUPUNotifEnabled } STATUS current DESCRIPTION "UPU notifications enable." ::= { ciscoGspMIBGroups 22 } ciscoGspNotificationsGroupSup2 NOTIFICATION-GROUP NOTIFICATIONS { ciscoGspUPUReceived, ciscoGspUPUTransmitted } STATUS current DESCRIPTION "Adjacent SP accessibility notification, UPU sent and received notifications." ::= { ciscoGspMIBGroups 23 } ciscoGspInstSccpWrrGroup OBJECT-GROUP OBJECTS { cgspInstSccpWrrOpcShift, cgspInstSccpWrrOption } STATUS current DESCRIPTION "SCCP GTT weighted loadshare group." ::= { ciscoGspMIBGroups 24 } ciscoGspLinkTableEntryGroupSup1 OBJECT-GROUP OBJECTS { cgspLinkRxCongestionState } STATUS current DESCRIPTION "cgspLinkRxCongestionstate object for Received side congestion" ::= { ciscoGspMIBGroups 25 } ciscoGspNotificationsGroupSup3 NOTIFICATION-GROUP NOTIFICATIONS { ciscoGspRxCongestionChange } STATUS current DESCRIPTION "Link Receive side congestion notication." ::= { ciscoGspMIBGroups 26 } END