-- ***************************************************************** -- CISCO-INTERFACE-XCVR-MONITOR-MIB.my -- -- Copyright (c) 2009 by cisco Systems Inc. -- All rights reserved. -- -- ***************************************************************** CISCO-INTERFACE-XCVR-MONITOR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF ifName FROM IF-MIB TEXTUAL-CONVENTION FROM SNMPv2-TC ciscoMgmt FROM CISCO-SMI; ciscoInterfaceXcvrMonitorMIB MODULE-IDENTITY LAST-UPDATED "200910090000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: sanos-pm@cisco.com" DESCRIPTION "A MIB module that provides monitoring information about the transceivers plugged into interface on a system." REVISION "200910090000Z" DESCRIPTION "Initial version of this MIB module." ::= { ciscoMgmt 706 } -- Textual Conventions CiscoInterfaceXcvrMonitorStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention defines the status of the monitoring parameter for a given sensor type in transceiver digital diagnostics on an interface. The value of the monitoring parameter for a given sensor lies are bounded within maximum (high) and minimum (low) limits. If the current value is over the high limit, this status is set to 'highSet'. Upon the value of the sensor coming back into the normal range (between high and low values), this status is set to 'highClear'. Similarly, if the current value is below the low limit, this status is set to 'lowSet'. Upon the value the sensor coming back into normal range subsequently, this status is set to 'lowClear'. If the current value is stays within the high and low limits, this status is set to 'normal'. Also, subsequently after the status had been either 'highClear' or 'lowClear', if the value is within the high and low limits, this status is set to 'normal'." SYNTAX INTEGER { highSet(1), lowSet(2), highClear(3), lowClear(4), normal(5) } ciscoInterfaceXcvrMonMIBNotifs OBJECT IDENTIFIER ::= { ciscoInterfaceXcvrMonitorMIB 0 } ciscoInterfaceXcvrMonMIBObjects OBJECT IDENTIFIER ::= { ciscoInterfaceXcvrMonitorMIB 1 } ciscoInterfaceXcvrMonMIBConform OBJECT IDENTIFIER ::= { ciscoInterfaceXcvrMonitorMIB 2 } -- Cisco Interface Transceiver Digital Diagnostics -- Monitoring Information cIfXcvrMonDigitalDiagTempAlarm OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of temperature alarm flag on the temperature sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 1 } cIfXcvrMonDigitalDiagTempWarning OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of temperature warning flag on the temperature sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 2 } cIfXcvrMonDigitalDiagVoltAlarm OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of voltage alarm flag on the voltage sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 3 } cIfXcvrMonDigitalDiagVoltWarning OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of voltage warning flag on the voltage sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 4 } cIfXcvrMonDigitalDiagCurrAlarm OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of current alarm flag on the current sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 5 } cIfXcvrMonDigitalDiagCurrWarning OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of current warning flag on the current sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 6 } cIfXcvrMonDigitalDiagRxPwrAlarm OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of Rx power alarm flag on the Rx power sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 7 } cIfXcvrMonDigitalDiagRxPwrWarning OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of Rx power warning flag on the Rx power sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 8 } cIfXcvrMonDigitalDiagTxPwrAlarm OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of Tx power alarm flag on the Tx power sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 9 } cIfXcvrMonDigitalDiagTxPwrWarning OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of Tx power warning flag on the Tx power sensor of the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 10 } cIfXcvrMonDigitalDiagTxFaultAlarm OBJECT-TYPE SYNTAX CiscoInterfaceXcvrMonitorStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current status of Tx fault count flag on the transceiver in the interface." ::= { ciscoInterfaceXcvrMonMIBObjects 11 } cIfXcvrMonStatusChangeNotifEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether cIfXcvrMonStatusChangeNotif should be generated." ::= { ciscoInterfaceXcvrMonMIBObjects 12 } cIfXcvrMonStatusChangeNotif NOTIFICATION-TYPE OBJECTS { ifName, cIfXcvrMonDigitalDiagTempAlarm, cIfXcvrMonDigitalDiagTempWarning, cIfXcvrMonDigitalDiagVoltAlarm, cIfXcvrMonDigitalDiagVoltWarning, cIfXcvrMonDigitalDiagCurrAlarm, cIfXcvrMonDigitalDiagCurrWarning, cIfXcvrMonDigitalDiagRxPwrAlarm, cIfXcvrMonDigitalDiagRxPwrWarning, cIfXcvrMonDigitalDiagTxPwrAlarm, cIfXcvrMonDigitalDiagTxPwrWarning, cIfXcvrMonDigitalDiagTxFaultAlarm } STATUS current DESCRIPTION "This notification trap indicates the current status of the alarm and warning monitoring parameters for all the sensors based on the digital diagnostic monitoring information. This notification is generated whenever there is a change in the status of atleast one of the monitoring parameters of the sensors on the transceiver in an interface." ::= { ciscoInterfaceXcvrMonMIBNotifs 1 } ciscoInterfaceXcvrMonMIBCompliances OBJECT IDENTIFIER ::= { ciscoInterfaceXcvrMonMIBConform 1 } ciscoInterfaceXcvrMonMIBGroups OBJECT IDENTIFIER ::= { ciscoInterfaceXcvrMonMIBConform 2 } cIfXcvrMonMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This is a default module-compliance containing default object groups." MODULE -- this module MANDATORY-GROUPS { cIfXcvrDigitalDiagMonStatusGroup, cIfXcvrMonStatusChangeNotifGroup } OBJECT cIfXcvrMonStatusChangeNotifEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { ciscoInterfaceXcvrMonMIBCompliances 1 } -- Units of Conformance cIfXcvrDigitalDiagMonStatusGroup OBJECT-GROUP OBJECTS { cIfXcvrMonDigitalDiagTempAlarm, cIfXcvrMonDigitalDiagTempWarning, cIfXcvrMonDigitalDiagVoltAlarm, cIfXcvrMonDigitalDiagVoltWarning, cIfXcvrMonDigitalDiagCurrAlarm, cIfXcvrMonDigitalDiagCurrWarning, cIfXcvrMonDigitalDiagRxPwrAlarm, cIfXcvrMonDigitalDiagRxPwrWarning, cIfXcvrMonDigitalDiagTxPwrAlarm, cIfXcvrMonDigitalDiagTxPwrWarning, cIfXcvrMonDigitalDiagTxFaultAlarm, cIfXcvrMonStatusChangeNotifEnable } STATUS current DESCRIPTION "A collection of Cisco specific Digital Diagnostics monitoring status information." ::= { ciscoInterfaceXcvrMonMIBGroups 1 } cIfXcvrMonStatusChangeNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { cIfXcvrMonStatusChangeNotif } STATUS current DESCRIPTION "A collection of Cisco specific Digital Diagnostics monitoring notifications." ::= { ciscoInterfaceXcvrMonMIBGroups 2 } END