-- ***************************************************************** -- CISCO-FC-MGMT-MIB: Cisco Fibre Channel Management MIB file -- -- August 2002, Arvind Prabhudev -- -- Copyright (c) 2002 by Cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** CISCO-FC-MGMT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, Counter64 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC ifIndex FROM IF-MIB ciscoExperiment FROM CISCO-SMI SnmpAdminString FROM SNMP-FRAMEWORK-MIB; ciscoFcMgmtMIB MODULE-IDENTITY LAST-UPDATED "200209120000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-dwdm@cisco.com" DESCRIPTION "This module defines management information specific to Fibre Channel-attached devices. This module is an adaptation of IETF's IPS working group's draft, draft-ietf-ips-fcmgmt-mib-02" REVISION "200209120000Z" DESCRIPTION "Initial version of Cisco Fibre Channel Management MIB module." ::= { ciscoExperiment 999999 } cfcmgmtObjects OBJECT IDENTIFIER ::= { ciscoFcMgmtMIB 1 } cfcmgmtNotifications OBJECT IDENTIFIER ::= { ciscoFcMgmtMIB 2 } cfcmgmtNotifPrefix OBJECT IDENTIFIER ::= { cfcmgmtNotifications 0 } cfcmgmtConformance OBJECT IDENTIFIER ::= { ciscoFcMgmtMIB 3 } -- ******************************** -- Textual Conventions -- CfcmFcNameIdOrZero ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The World Wide Name (WWN) associated with a Fibre Channel (FC) entity. WWNs were initially defined as 64-bits in length. The latest definition (for future use) is 128-bits long. The zero-length string value is used in circumstances where the WWN is unassigned/unknown." SYNTAX OCTET STRING (SIZE(0 | 8 | 16)) CfcmFcAddressId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A Fibre Channel Address ID, a 24-bit value unique within the address space of a Fabric." SYNTAX OCTET STRING (SIZE(0 | 3)) CfcmDomainIdOrZero ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The Domain Id (of a FC switch), or zero if no Domain Id has been assigned." SYNTAX INTEGER(0..239) CfcmFcPortType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The type of a Fibre Channel port, being one of the types described below. unknown - Fibre Channel port type is not known. other - the port type is something other than the ones described below. dynamic - the port could be one of the below port types and this varies dynamically. nPort - Any port on a node device, e.g., a disk, PC, etc. that is directly attached to a Fabric port. (Refer FC-PH, FC-FS). nlPort - An 'nPort' that also has arbitrated loop capabilities. (Refer FC-AL-2). fPort - A port on a fibre channel fabric. (Refer FC-PH, FC-FS). flPort - A 'fPort' that also has arbitrated loop capabilities. (Refer FC-AL-2). ePort - A fabric expansion port which attaches to another 'ePort' or 'bPort' to create an Inter-Switch Link. (Refer FC-SW-2). bPort - A bridge port on a device that implements FC-BBW and connects to an E_port on a switch. (Refer FC-BB)." SYNTAX INTEGER { unknown(1), other(2), -- none of the below dynamic(3), -- determined dynamically nPort(4), nlPort(5), fPort(6), flPort(7), ePort(8), bPort(9) } CfcmFcClasses ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A set of Fibre Channel classes of service." REFERENCE "Classes of service are described in FC-FS Section 13." SYNTAX BITS { classF(0), class1(1), class2(2), class3(3), class4(4), class5(5), class6(6) } CfcmFcBbCredit ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The buffer-to-buffer credit of an FC port. i.e., the number of frames a FC device can receive at a time without causing a buffer overrun condition." SYNTAX Integer32 (0..32767) CfcmFcBbCreditModel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The buffer-to-buffer credit model of an Fx_Port." SYNTAX INTEGER { regular(1), alternate (2) } CfcmFcDataFieldSize ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The Receive Data Field Size associated with an FC port." SYNTAX Integer32 (128..2112) CfcmFcUnitFunctions ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A set of functions that a Fibre Channel Interconnect Element or Platform might perform. A value with no bits set, indicates the function(s) are unknown. The individual bits have the following meanings: other - none of the following. hub - a device that interconnects L_Ports, but does not operate as an FL_Port. switch - a fabric element conforming to the Fibre Channel switch fabric set of standards (e.g., FC-SW, FC-SW-2). bridge - a device that encapsulates Fibre Channel frames within another protocol (e.g., FC-BB, FC-BB-2). gateway - a device that converts an FC-4 to another protocol (e.g., FCP to iSCSI). host - a computer system that provides end users services such as computation and storage access. storageSubsys - an integrated collection of storage controllers, storage devices, and necessary software, that provides storage services to one or more hosts. storageAccessDev - a device that provides storage management and access for heterogeneous hosts and heterogeneous devices (e.g., medium changer). nas - a device that connects to a network and provides file access services. wdmux - a device that modulates/demodulates each of several data streams (e.g., Fibre Channel protocol data streams) onto/from a different part of the light spectrum in an optical fiber." SYNTAX BITS { other(0), -- none of the following hub(1), switch(2), bridge(3), gateway(4), host(5), storageSubsys(6), storageAccessDev(7), nas(8), wdmux(9) } CfcmPhysicalIndexOrZero ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The index value for a physical entity's row in the Entity MIB's entPhysicalTable. A zero value indicates that no row in the entPhysicalTable is applicable." REFERENCE "entPhysicalTable is defined in the Entity MIB, RFC 2737." SYNTAX INTEGER (0..2147483647) CfcmHrSWInstalledIndexOrZero ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The index value for a software module's row in the Host Resources MIB's hrSWInstalledTable. A zero value indicates that no row in the hrSWInstalledTable is applicable." REFERENCE "hrSWInstalledTable is defined in the Host Resources MIB, RFC 2790." SYNTAX Integer32 (0..2147483647) CfcmMilliSeconds ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Time units in milliseconds." SYNTAX Unsigned32 CfcmMicroSeconds ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Time units in microseconds." SYNTAX Unsigned32 --******************************** -- MIB object definitions -- cfcmInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the local Fibre Channel management instances." ::= { cfcmgmtObjects 1 } cfcmInstanceEntry OBJECT-TYPE SYNTAX CfcmInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of attributes for a particular local Fibre Channel management instance." INDEX { cfcmInstanceIndex } ::= { cfcmInstanceTable 1 } CfcmInstanceEntry ::= SEQUENCE { cfcmInstanceIndex Unsigned32, cfcmInstanceWwn CfcmFcNameIdOrZero, cfcmInstanceFunctions CfcmFcUnitFunctions, cfcmInstancePhysicalIndex CfcmPhysicalIndexOrZero, cfcmInstanceSoftwareIndex CfcmHrSWInstalledIndexOrZero, cfcmInstanceStatus INTEGER, cfcmInstanceTextName SnmpAdminString, cfcmInstanceDescr SnmpAdminString, cfcmInstanceFabricId CfcmFcNameIdOrZero } cfcmInstanceIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer value which uniquely identifies this instance amongst all local Fibre Channel management instances. It is mandatory that this value remain constant between restarts of the agent except, in case of certain re- configurations of the local system where it is natural for it to change. It is desirable that this value remain constant across restarts." ::= { cfcmInstanceEntry 1 } cfcmInstanceWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "If the instance has one (or more) WWN(s), then this object contains that (or one of those) WWN(s). If the instance does not have a WWN associated with it, then this object contains the zero-length string." ::= { cfcmInstanceEntry 2 } cfcmInstanceFunctions OBJECT-TYPE SYNTAX CfcmFcUnitFunctions MAX-ACCESS read-only STATUS current DESCRIPTION "One (or more) Fibre Channel unit functions being performed by this instance." ::= { cfcmInstanceEntry 3 } cfcmInstancePhysicalIndex OBJECT-TYPE SYNTAX CfcmPhysicalIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "If this management instance corresponds to a physical component (or to a hierarchy of physical components), then this object's value is the value of the entPhysicalIndex of that component (or of the component at the root of that hierarchy). If there is no correspondence to a physical component (or no component which has an entPhysicalIndex value), then the value of this object is zero." REFERENCE "entPhysicalIndex is defined in the Entity MIB, RFC 2737." ::= { cfcmInstanceEntry 4 } cfcmInstanceSoftwareIndex OBJECT-TYPE SYNTAX CfcmHrSWInstalledIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "If this management instance corresponds to an installed software module, then this object's value is the value of the hrSWInstalledIndex of that module. If there is no correspondence to an installed software module (or no module which has a hrSWInstalledIndex value), then the value of this object is zero." REFERENCE "hrSWInstalledIndex is defined in the Host Resources MIB, RFC 2790" ::= { cfcmInstanceEntry 5 } cfcmInstanceStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), ok(2), -- able to operate correctly warning(3), -- needs attention failed(4) -- something has failed } MAX-ACCESS read-only STATUS current DESCRIPTION "Overall status of the Fibre Channel entity/entities managed by this management instance. The value should reflect the most serious status of such entities." ::= { cfcmInstanceEntry 6 } cfcmInstanceTextName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..79)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual name for this management instance and the Fibre Channel entity/entities that it is managing." ::= { cfcmInstanceEntry 7 } cfcmInstanceDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "A textual description of this management instance and the Fibre Channel entity/entities that it is managing." ::= { cfcmInstanceEntry 8 } cfcmInstanceFabricId OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The globally unique Fabric Identifier which identifies the fabric to which the Fibre Channel entity/entities managed by this management instance are connected, or, of which they are a part. This is typically the Node WWN of the principal switch of a Fibre Channel fabric. The zero-length string indicates that the fabric identifier is unknown (or not applicable)." ::= { cfcmInstanceEntry 9 } --******************************** -- The Fibre Channel Switch Table -- cfcmSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information about Fibre Channel switches which are managed by Fibre Channel management instances. Each Fibre Channel management instance can manage one or more Fibre Channel switches." ::= { cfcmgmtObjects 2 } cfcmSwitchEntry OBJECT-TYPE SYNTAX CfcmSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular Fibre Channel switch which is managed by the management instance given by cfcmInstanceIndex." INDEX { cfcmInstanceIndex, cfcmSwitchIndex } ::= { cfcmSwitchTable 1 } CfcmSwitchEntry ::= SEQUENCE { cfcmSwitchIndex Unsigned32, cfcmSwitchDomainId CfcmDomainIdOrZero, cfcmSwitchPrincipal TruthValue } cfcmSwitchIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer which uniquely identifies a Fibre Channel switch amongst those managed by one Fibre Channel management instance." ::= { cfcmSwitchEntry 1 } cfcmSwitchDomainId OBJECT-TYPE SYNTAX CfcmDomainIdOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "The Domain Id of this switch. A value of zero indicates that a switch has not (yet) been assigned a Domain Id." ::= { cfcmSwitchEntry 2 } cfcmSwitchPrincipal OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this switch is the principal switch within its fabric." ::= { cfcmSwitchEntry 3 } --******************************** -- The Fibre Channel Port Table -- cfcmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about Fibre Channel ports. Each Fibre Channel port is represented by one entry in the IF-MIB's ifTable." REFERENCE "RFC 2863, The Interfaces Group MIB, June 2000." ::= { cfcmgmtObjects 3 } cfcmPortEntry OBJECT-TYPE SYNTAX CfcmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about a specific port." INDEX { ifIndex } ::= { cfcmPortTable 1 } CfcmPortEntry ::= SEQUENCE { cfcmPortInstanceIndex Unsigned32, cfcmPortWwn CfcmFcNameIdOrZero, cfcmPortNodeWwn CfcmFcNameIdOrZero, cfcmPortAdminType CfcmFcPortType, cfcmPortOperType CfcmFcPortType, cfcmPortFcCapClass CfcmFcClasses, cfcmPortFcOperClass CfcmFcClasses, cfcmPortTransmitterType INTEGER, cfcmPortConnectorType INTEGER, cfcmPortSerialNumber SnmpAdminString, cfcmPortPhysicalNumber Unsigned32, cfcmPortAdminSpeed INTEGER, cfcmPortCapProtocols BITS, cfcmPortOperProtocols BITS } cfcmPortInstanceIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of cfcmInstanceIndex by which the Fibre Channel management instance, which manages this port, is identified in the cfcmInstanceTable." ::= { cfcmPortEntry 1 } cfcmPortWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The World Wide Name of the port, or the zero-length string if the port does not have a WWN." ::= { cfcmPortEntry 2 } cfcmPortNodeWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The World Wide Name of the Node which contains this port, or the zero-length string if the port does not have a node WWN." ::= { cfcmPortEntry 3 } cfcmPortAdminType OBJECT-TYPE SYNTAX CfcmFcPortType MAX-ACCESS read-write STATUS current DESCRIPTION "The administratively desired type of this port. Each port will typically only be able to support a subset of these types." ::= { cfcmPortEntry 4 } cfcmPortOperType OBJECT-TYPE SYNTAX CfcmFcPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational type of this port." ::= { cfcmPortEntry 5 } cfcmPortFcCapClass OBJECT-TYPE SYNTAX CfcmFcClasses MAX-ACCESS read-only STATUS current DESCRIPTION "The classes of service capability of this port." ::= { cfcmPortEntry 6 } cfcmPortFcOperClass OBJECT-TYPE SYNTAX CfcmFcClasses MAX-ACCESS read-only STATUS current DESCRIPTION "The classes of service that are currently operational on this port. For an FL_Port, this is the union of the classes being supported across all attached NL_Ports." ::= { cfcmPortEntry 7 } cfcmPortTransmitterType OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), shortwave850nm(3), longwave1550nm(4), longwave1310nm(5), electrical(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The technology of the port transceiver." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.2.3" ::= { cfcmPortEntry 8 } cfcmPortConnectorType OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), gbic(3), embedded(4), glm(5), gbicSerialId(6), gbicNoSerialId(7), sfpSerialId(8), sfpNoSerialId(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The module type of the port connector. This object refers to the hardware implementation of the port. It will be 'embedded' if the hardware equivalent to Gigabit interface card (GBIC) is part of the line card and is unremovable. It will be 'glm' if it's a gigabit link module (GLM). It will be 'gbicSerialId' if the GBIC serial id can be read, else it will be 'gbicNoSerialId'. It will be 'sfpSerialId', if the small form factor (SFP) pluggable GBICs serial id can be read, else it will be 'sfpNoSerialId'." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.2.4" ::= { cfcmPortEntry 9 } cfcmPortSerialNumber OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number associated with the port (e.g., for a GBIC). If not applicable, the object's value is a zero- length string." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.2.4" ::= { cfcmPortEntry 10 } cfcmPortPhysicalNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the port's 'Physical Port Number' as defined by GS-3." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.2.5" ::= { cfcmPortEntry 11 } cfcmPortAdminSpeed OBJECT-TYPE SYNTAX INTEGER { auto(1), eighthGbs(2), -- 125Mbs quarterGbs(3), -- 250Mbs halfGbs(4), -- 500Mbs oneGbs(5), -- 1Gbs twoGbs(6), -- 2Gbs fourGbs(7), -- 4Gbs tenGbs(8) -- 10Gbs } MAX-ACCESS read-write STATUS current DESCRIPTION "The speed of the interface: 'auto' - auto-negotiation 'tenGbs' - 10Gbs 'fourGbs' - 4Gbs 'twoGbs' - 2Gbs 'oneGbs' - 1Gbs 'halfGbs' - 500Mbs 'quarterGbs' - 250Mbs 'eighthGbs' - 125Mbs" ::= { cfcmPortEntry 12 } cfcmPortCapProtocols OBJECT-TYPE SYNTAX BITS { unknown(0), loop(1), fabric(2), scsi(3), tcpIp(4), vi(5), ficon(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit mask specifying the higher level protocols which are supported on this port. Note that for generic Fx_Ports, E_Ports and B_Ports, this object will indicate all protocols." ::= { cfcmPortEntry 13 } cfcmPortOperProtocols OBJECT-TYPE SYNTAX BITS { unknown(0), loop(1), fabric(2), scsi(3), tcpIp(4), vi(5), ficon(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "A bit mask specifying the higher level protocols which are currently operational on this port. For Fx_Ports, E_Ports and B_Ports, this object will typically have the value 'unknown'." ::= { cfcmPortEntry 14 } --******************************** -- Port Statistics -- cfcmPortStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of statistics for Fibre Channel ports." ::= { cfcmgmtObjects 4 } cfcmPortStatsEntry OBJECT-TYPE SYNTAX CfcmPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing statistics for a Fibre Channel port." AUGMENTS { cfcmPortEntry } ::= { cfcmPortStatsTable 1 } CfcmPortStatsEntry ::= SEQUENCE { cfcmPortBBCreditZeros Counter64, cfcmPortFullInputBuffers Counter64, cfcmPortClass2RxFrames Counter64, cfcmPortClass2RxOctets Counter64, cfcmPortClass2TxFrames Counter64, cfcmPortClass2TxOctets Counter64, cfcmPortClass2Discards Counter64, cfcmPortClass2RxFbsyFrames Counter64, cfcmPortClass2RxPbsyFrames Counter64, cfcmPortClass2RxFrjtFrames Counter64, cfcmPortClass2RxPrjtFrames Counter64, cfcmPortClass2TxFbsyFrames Counter64, cfcmPortClass2TxPbsyFrames Counter64, cfcmPortClass2TxFrjtFrames Counter64, cfcmPortClass2TxPrjtFrames Counter64, cfcmPortClass3RxFrames Counter64, cfcmPortClass3RxOctets Counter64, cfcmPortClass3TxFrames Counter64, cfcmPortClass3TxOctets Counter64, cfcmPortClass3Discards Counter64, cfcmPortClassFRxFrames Counter32, cfcmPortClassFRxOctets Counter32, cfcmPortClassFTxFrames Counter32, cfcmPortClassFTxOctets Counter32, cfcmPortClassFDiscards Counter32 } cfcmPortBBCreditZeros OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transitions in/out of the buffer-to-buffer credit zero state. The other side is not providing any credit." ::= { cfcmPortStatsEntry 1 } cfcmPortFullInputBuffers OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero, i.e., there became no credit to provide to other side." ::= { cfcmPortStatsEntry 2 } cfcmPortClass2RxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames received at this port." ::= { cfcmPortStatsEntry 3 } cfcmPortClass2RxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames received at this port." ::= { cfcmPortStatsEntry 4 } cfcmPortClass2TxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames transmitted out of this port." ::= { cfcmPortStatsEntry 5 } cfcmPortClass2TxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames transmitted out of this port." ::= { cfcmPortStatsEntry 6 } cfcmPortClass2Discards OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames that were discarded upon reception at this port." ::= { cfcmPortStatsEntry 7 } cfcmPortClass2RxFbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when either the fabric or the destination port is temporarily busy. Note that this counter will never increment for an F_Port." ::= { cfcmPortStatsEntry 8 } cfcmPortClass2RxPbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when the destination port is temporarily busy." ::= { cfcmPortStatsEntry 9 } cfcmPortClass2RxFrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was returned to this port as a result of a Class 2 frame that was rejected by the fabric. Note that this counter will never increment for an F_Port." ::= { cfcmPortStatsEntry 10 } cfcmPortClass2RxPrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was returned to this port as a result of a Class 2 frame that was rejected at the destination N_Port." ::= { cfcmPortStatsEntry 11 } cfcmPortClass2TxFbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because either the Fabric or the destination port was temporarily busy. Note that this counter will never increment for an N_Port." ::= { cfcmPortStatsEntry 12 } cfcmPortClass2TxPbsyFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because the destination port was temporarily busy. Note that this counter will never increment for an F_Port." ::= { cfcmPortStatsEntry 13 } cfcmPortClass2TxFrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was generated by this port as a result of a Class 2 frame being rejected by the fabric. Note that this counter will never increment for an N_Port." ::= { cfcmPortStatsEntry 14 } cfcmPortClass2TxPrjtFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was generated by this port as a result of a Class 2 frame being rejected at the destination N_Port. Note that this counter will never increment for an F_Port." ::= { cfcmPortStatsEntry 15 } cfcmPortClass3RxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames received at this port." ::= { cfcmPortStatsEntry 16 } cfcmPortClass3RxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames received at this port." ::= { cfcmPortStatsEntry 17 } cfcmPortClass3TxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames transmitted out of this port." ::= { cfcmPortStatsEntry 18 } cfcmPortClass3TxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames transmitted out of this port." ::= { cfcmPortStatsEntry 19 } cfcmPortClass3Discards OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames that were discarded upon reception at this port." ::= { cfcmPortStatsEntry 20 } cfcmPortClassFRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class F frames received at this port." ::= { cfcmPortStatsEntry 21 } cfcmPortClassFRxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class F frames received at this port." ::= { cfcmPortStatsEntry 22 } cfcmPortClassFTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class F frames transmitted out of this port." ::= { cfcmPortStatsEntry 23 } cfcmPortClassFTxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class F frames transmitted out of this port." ::= { cfcmPortStatsEntry 24 } cfcmPortClassFDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class F frames that were discarded upon reception at this port." ::= { cfcmPortStatsEntry 25 } --******************************** -- Port Low-capacity Statistics -- -- these are Counter32 "low-capacity" counters for systems -- which do not support Counter64's cfcmPortLcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmPortLcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Counter32-based statistics which are a shadow of the Counter64 statistics in the cfcmPortStatsTable, for systems which do not support Counter64." ::= { cfcmgmtObjects 5 } cfcmPortLcStatsEntry OBJECT-TYPE SYNTAX CfcmPortLcStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing low-capacity (i.e., based on Counter32) statistics for a Fibre Channel port." AUGMENTS { cfcmPortEntry } ::= { cfcmPortLcStatsTable 1 } CfcmPortLcStatsEntry ::= SEQUENCE { cfcmPortLcBBCreditZeros Counter32, cfcmPortLcFullInputBuffers Counter32, cfcmPortLcClass2RxFrames Counter32, cfcmPortLcClass2RxOctets Counter32, cfcmPortLcClass2TxFrames Counter32, cfcmPortLcClass2TxOctets Counter32, cfcmPortLcClass2Discards Counter32, cfcmPortLcClass2RxFbsyFrames Counter32, cfcmPortLcClass2RxPbsyFrames Counter32, cfcmPortLcClass2RxFrjtFrames Counter32, cfcmPortLcClass2RxPrjtFrames Counter32, cfcmPortLcClass2TxFbsyFrames Counter32, cfcmPortLcClass2TxPbsyFrames Counter32, cfcmPortLcClass2TxFrjtFrames Counter32, cfcmPortLcClass2TxPrjtFrames Counter32, cfcmPortLcClass3RxFrames Counter32, cfcmPortLcClass3RxOctets Counter32, cfcmPortLcClass3TxFrames Counter32, cfcmPortLcClass3TxOctets Counter32, cfcmPortLcClass3Discards Counter32 } cfcmPortLcBBCreditZeros OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transitions in/out of the buffer-to-buffer credit zero state. The other side is not providing any credit." ::= { cfcmPortLcStatsEntry 1 } cfcmPortLcFullInputBuffers OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero, i.e., there became no credit to provide to other side." ::= { cfcmPortLcStatsEntry 2 } cfcmPortLcClass2RxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames received at this port." ::= { cfcmPortLcStatsEntry 3 } cfcmPortLcClass2RxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames received at this port." ::= { cfcmPortLcStatsEntry 4 } cfcmPortLcClass2TxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames transmitted out of this port." ::= { cfcmPortLcStatsEntry 5 } cfcmPortLcClass2TxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 2 frames transmitted out of this port." ::= { cfcmPortLcStatsEntry 6 } cfcmPortLcClass2Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 2 frames that were discarded upon reception at this port." ::= { cfcmPortLcStatsEntry 7 } cfcmPortLcClass2RxFbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when either the fabric or the destination port is temporarily busy. Note that this counter will never increment for an F_Port." ::= { cfcmPortLcStatsEntry 8 } cfcmPortLcClass2RxPbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when the destination port is temporarily busy." ::= { cfcmPortLcStatsEntry 9 } cfcmPortLcClass2RxFrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was returned to this port as a result of a Class 2 frame that was rejected by the fabric. Note that this counter will never increment for an F_Port." ::= { cfcmPortLcStatsEntry 10 } cfcmPortLcClass2RxPrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was returned to this port as a result of a Class 2 frame that was rejected at the destination N_Port." ::= { cfcmPortLcStatsEntry 11 } cfcmPortLcClass2TxFbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because either the Fabric or the destination port was temporarily busy. Note that this counter will never increment for an N_Port." ::= { cfcmPortLcStatsEntry 12 } cfcmPortLcClass2TxPbsyFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because the destination port was temporarily busy. Note that this counter will never increment for an F_Port." ::= { cfcmPortLcStatsEntry 13 } cfcmPortLcClass2TxFrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that F_RJT was generated by this port as a result of a Class 2 frame being rejected by the fabric. Note that this counter will never increment for an N_Port." ::= { cfcmPortLcStatsEntry 14 } cfcmPortLcClass2TxPrjtFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times that P_RJT was generated by this port as a result of a Class 2 frame being rejected at the destination N_Port. Note that this counter will never increment for an F_Port." ::= { cfcmPortLcStatsEntry 15 } cfcmPortLcClass3RxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames received at this port." ::= { cfcmPortLcStatsEntry 16 } cfcmPortLcClass3RxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames received at this port." ::= { cfcmPortLcStatsEntry 17 } cfcmPortLcClass3TxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames transmitted out of this port." ::= { cfcmPortLcStatsEntry 18 } cfcmPortLcClass3TxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets contained in Class 3 frames transmitted out of this port." ::= { cfcmPortLcStatsEntry 19 } cfcmPortLcClass3Discards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Class 3 frames that were discarded upon reception at this port." ::= { cfcmPortLcStatsEntry 20 } --******************************** -- Port Error Counters -- cfcmPortErrorsTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmPortErrorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Error counters for Fibre Channel ports." ::= { cfcmgmtObjects 6 } cfcmPortErrorsEntry OBJECT-TYPE SYNTAX CfcmPortErrorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Error counters for a Fibre Channel port." AUGMENTS { cfcmPortEntry } ::= { cfcmPortErrorsTable 1 } CfcmPortErrorsEntry ::= SEQUENCE { cfcmPortRxLinkResets Counter32, cfcmPortTxLinkResets Counter32, cfcmPortLinkResets Counter32, cfcmPortRxOfflineSequences Counter32, cfcmPortTxOfflineSequences Counter32, cfcmPortLinkFailures Counter32, cfcmPortLossofSynchs Counter32, cfcmPortLossofSignals Counter32, cfcmPortPrimSeqProtocolErrors Counter32, cfcmPortInvalidTxWords Counter32, cfcmPortInvalidCRCs Counter32, cfcmPortInvalidOrderedSets Counter32, cfcmPortFrameTooLongs Counter32, cfcmPortTruncatedFrames Counter32, cfcmPortAddressErrors Counter32, cfcmPortDelimiterErrors Counter32, cfcmPortEncodingDisparityErrors Counter32, cfcmPortOtherErrors Counter32 } cfcmPortRxLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link resets (LR primitives) received." ::= { cfcmPortErrorsEntry 1 } cfcmPortTxLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Link resets (LRs primitive) transmitted." ::= { cfcmPortErrorsEntry 2 } cfcmPortLinkResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the reset link protocol was initiated on this port. This includes the number of Loop Initialization Primitive (LIP) events on an arbitrated loop port." ::= { cfcmPortErrorsEntry 3 } cfcmPortRxOfflineSequences OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline Primitive OLS received at this port." ::= { cfcmPortErrorsEntry 4 } cfcmPortTxOfflineSequences OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Offline Primitive OLS transmitted by this port." ::= { cfcmPortErrorsEntry 5 } cfcmPortLinkFailures OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of link failures. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { cfcmPortErrorsEntry 6 } cfcmPortLossofSynchs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of instances of synchronization loss detected at this port. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { cfcmPortErrorsEntry 7 } cfcmPortLossofSignals OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of instances of signal loss detected at this port. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { cfcmPortErrorsEntry 8 } cfcmPortPrimSeqProtocolErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of primitive sequence protocol errors detected at this port. This count is part of CFC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { cfcmPortErrorsEntry 9 } cfcmPortInvalidTxWords OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid transmission words received at this port. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { cfcmPortErrorsEntry 10 } cfcmPortInvalidCRCs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received with invalid CRC. This count is part of FC-PH's Link Error Status Block (LESB)." REFERENCE "FC-PH, rev 4.3, 1 June 1994, section 29.8." ::= { cfcmPortErrorsEntry 11 } cfcmPortInvalidOrderedSets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid ordered sets received at this port." ::= { cfcmPortErrorsEntry 12 } cfcmPortFrameTooLongs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received at this port where the frame length was greater than what was agreed to in FLOGI/PLOGI. This could be caused by losing the end of frame delimiter." ::= { cfcmPortErrorsEntry 13 } cfcmPortTruncatedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received at this port where the frame length was less than the minimum indicated by the frame header - normally 24 bytes, but it could be more if the DFCTL field indicates an optional header should have been present." ::= { cfcmPortErrorsEntry 14 } cfcmPortAddressErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received with unknown addressing. e.x. unknown SID or DID. the SID or DID is not known to the routing algorithm." ::= { cfcmPortErrorsEntry 15 } cfcmPortDelimiterErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of invalid frame delimiters received at this port. An example is a frame with a class 2 start and a class 3 at the end." ::= { cfcmPortErrorsEntry 16 } cfcmPortEncodingDisparityErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of encoding disparity errors received at this port." ::= { cfcmPortErrorsEntry 17 } cfcmPortOtherErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of errors which were detected on this port but which were not counted by any other error counter in this row." ::= { cfcmPortErrorsEntry 18 } --******************************** -- The Fibre Channel Fx_Port Table -- cfcmFxPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmFxPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Additional information about Fibre Channel ports which is specific to Fx_Ports. This table will contain one entry for each cfcmPortTable entry which represents an Fx_Port." ::= { cfcmgmtObjects 7 } cfcmFxPortEntry OBJECT-TYPE SYNTAX CfcmFxPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about FC protocol related timer values of a specific Fx_Port and information about buffer capacity, maximum data field size of frames handled by this port and other capability information." INDEX { ifIndex } ::= { cfcmFxPortTable 1 } CfcmFxPortEntry ::= SEQUENCE { cfcmFxPortRatov CfcmMilliSeconds, cfcmFxPortEdtov CfcmMilliSeconds, cfcmFxPortRttov CfcmMilliSeconds, cfcmFxPortHoldTime CfcmMicroSeconds, cfcmFxPortCapBbCreditMax CfcmFcBbCredit, cfcmFxPortCapBbCreditMin CfcmFcBbCredit, cfcmFxPortCapDataFieldSizeMax CfcmFcDataFieldSize, cfcmFxPortCapDataFieldSizeMin CfcmFcDataFieldSize, cfcmFxPortCapClass2SeqDeliv TruthValue, cfcmFxPortCapClass3SeqDeliv TruthValue, cfcmFxPortCapHoldTimeMax CfcmMicroSeconds, cfcmFxPortCapHoldTimeMin CfcmMicroSeconds } cfcmFxPortRatov OBJECT-TYPE SYNTAX CfcmMilliSeconds UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The Resource_Allocation_Timeout Value configured for this Fx_Port. This is used as the timeout value for determining when to reuse an Nx_Port resource such as a Recovery_Qualifier. It represents the Error_Detect_Timeout value (see cfcmFxPortEdtov) plus twice the maximum time that a frame may be delayed within the Fabric and still be delivered." ::= { cfcmFxPortEntry 1 } cfcmFxPortEdtov OBJECT-TYPE SYNTAX CfcmMilliSeconds UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The Error_Detect_Timeout value configured for this Fx_Port. This is used as the timeout value for detecting an error condition." ::= { cfcmFxPortEntry 2 } cfcmFxPortRttov OBJECT-TYPE SYNTAX CfcmMilliSeconds UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The Receiver_Transmitter_Timeout value of this Fx_Port. This is used by the receiver logic to detect Loss of Synchronization." ::= { cfcmFxPortEntry 3 } cfcmFxPortHoldTime OBJECT-TYPE SYNTAX CfcmMicroSeconds UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum time that this Fx_Port shall hold a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that this Fx_Port does not support this parameter." ::= { cfcmFxPortEntry 4 } cfcmFxPortCapBbCreditMax OBJECT-TYPE SYNTAX CfcmFcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of receive buffers which this port is capable of making available for holding frames from attached Nx_Port(s)." ::= { cfcmFxPortEntry 5 } cfcmFxPortCapBbCreditMin OBJECT-TYPE SYNTAX CfcmFcBbCredit UNITS "buffers" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum number of receive buffers which this port is capable of making available for holding frames from attached Nx_Port(s)." ::= { cfcmFxPortEntry 6 } cfcmFxPortCapDataFieldSizeMax OBJECT-TYPE SYNTAX CfcmFcDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size in bytes of the Data Field in a frame that this Fx_Port is capable of receiving from an attached Nx_Port." ::= { cfcmFxPortEntry 7 } cfcmFxPortCapDataFieldSizeMin OBJECT-TYPE SYNTAX CfcmFcDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum size in bytes of the Data Field in a frame that this Fx_Port is capable of receiving from an attached Nx_Port." ::= { cfcmFxPortEntry 8 } cfcmFxPortCapClass2SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this Fx_Port is capable of supporting Class 2 Sequential Delivery." ::= { cfcmFxPortEntry 9 } cfcmFxPortCapClass3SeqDeliv OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this Fx_Port is capable of supporting Class 3 Sequential Delivery." ::= { cfcmFxPortEntry 10 } cfcmFxPortCapHoldTimeMax OBJECT-TYPE SYNTAX CfcmMicroSeconds UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum holding time that this Fx_Port is capable of supporting." ::= { cfcmFxPortEntry 11 } cfcmFxPortCapHoldTimeMin OBJECT-TYPE SYNTAX CfcmMicroSeconds UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum holding time that this Fx_Port is capable of supporting." ::= { cfcmFxPortEntry 12 } --******************************** -- The Fibre Channel Inter-Switch Port Table -- cfcmISPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmISPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Additional information about E_Ports, B_Ports, and any other type of Fibre Channel port to which inter-switch links can be connected. This table will contain one entry for each cfcmPortTable entry which represents such a port." ::= { cfcmgmtObjects 8 } cfcmISPortEntry OBJECT-TYPE SYNTAX CfcmISPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about a specific port connected to an inter-switch link." INDEX { ifIndex } ::= { cfcmISPortTable 1 } CfcmISPortEntry ::= SEQUENCE { cfcmISPortClassFCredit CfcmFcBbCredit, cfcmISPortClassFDataFieldSize CfcmFcDataFieldSize } cfcmISPortClassFCredit OBJECT-TYPE SYNTAX CfcmFcBbCredit MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of Class F data frames which can be transmitted by the inter-switch port without receipt of ACK or Link_Response frames." ::= { cfcmISPortEntry 1 } cfcmISPortClassFDataFieldSize OBJECT-TYPE SYNTAX CfcmFcDataFieldSize UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The Receive Data Field Size which the inter-switch port has agreed to support for Class F frames to/from this port. The size specifies the largest Data Field Size for an FT_1 frame." ::= { cfcmISPortEntry 2 } --******************************** -- The Fabric Login table -- -- This table contains the information held by FC switches -- about the Nx_Ports which are logged-in/attached to their -- Fx_Ports cfcmFLoginTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmFLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains one entry for each Nx_Port logged- in/attached to a particular Fx_Port in the switch. Each entry contains the services parameters established during the most recent Fabric Login, explicit or implicit. Note that an Fx_Port may have one or more Nx_Ports attached to it." ::= { cfcmgmtObjects 9 } cfcmFLoginEntry OBJECT-TYPE SYNTAX CfcmFLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing service parameters established from a successful Fabric Login." INDEX { ifIndex, cfcmFLoginNxPortIndex } ::= { cfcmFLoginTable 1 } CfcmFLoginEntry ::= SEQUENCE { cfcmFLoginNxPortIndex Unsigned32, cfcmFLoginPortWwn CfcmFcNameIdOrZero, cfcmFLoginNodeWwn CfcmFcNameIdOrZero, cfcmFLoginBbCreditModel CfcmFcBbCreditModel, cfcmFLoginBbCredit CfcmFcBbCredit, cfcmFLoginClassesAgreed CfcmFcClasses, cfcmFLoginClass2SeqDelivAgreed TruthValue, cfcmFLoginClass2DataFieldSize CfcmFcDataFieldSize, cfcmFLoginClass3SeqDelivAgreed TruthValue, cfcmFLoginClass3DataFieldSize CfcmFcDataFieldSize } cfcmFLoginNxPortIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer which uniquely identifies an Nx_Port amongst all those attached to the Fx_Port indicated by ifIndex." ::= { cfcmFLoginEntry 1 } cfcmFLoginPortWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The port name of the attached Nx_Port, or the zero-length string if unknown." ::= { cfcmFLoginEntry 2 } cfcmFLoginNodeWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The node name of the attached Nx_Port, or the zero-length string if unknown." ::= { cfcmFLoginEntry 3 } cfcmFLoginBbCreditModel OBJECT-TYPE SYNTAX CfcmFcBbCreditModel MAX-ACCESS read-only STATUS current DESCRIPTION "The buffer-to-buffer credit model in use by the Fx_Port." ::= { cfcmFLoginEntry 4 } cfcmFLoginBbCredit OBJECT-TYPE SYNTAX CfcmFcBbCredit MAX-ACCESS read-only STATUS current DESCRIPTION "The number of buffers available for holding frames to be transmitted to the attached Nx_Port. These buffers are for buffer-to-buffer flow control in the direction from Fx_Port to Nx_Port." ::= { cfcmFLoginEntry 5 } cfcmFLoginClassesAgreed OBJECT-TYPE SYNTAX CfcmFcClasses MAX-ACCESS read-only STATUS current DESCRIPTION "The Classes of Service which the Fx_Port has agreed to support for this Nx_Port." ::= { cfcmFLoginEntry 6 } cfcmFLoginClass2SeqDelivAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether the Fx_Port has agreed to support Class 2 sequential delivery for this Nx_Port. This is only meaningful if Class 2 service has been agreed." ::= { cfcmFLoginEntry 7 } cfcmFLoginClass2DataFieldSize OBJECT-TYPE SYNTAX CfcmFcDataFieldSize MAX-ACCESS read-only STATUS current DESCRIPTION "The Receive Data Field Size which the Fx_Port has agreed to support for Class 2 frames to/from this Nx_Port. The size specifies the largest Data Field Size for an FT_1 frame. This is only meaningful if Class 2 service has been agreed." ::= { cfcmFLoginEntry 8 } cfcmFLoginClass3SeqDelivAgreed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether the Fx_Port has agreed to support Class 3 sequential delivery for this Nx_Port. This is only meaningful if Class 3 service has been agreed." ::= { cfcmFLoginEntry 9 } cfcmFLoginClass3DataFieldSize OBJECT-TYPE SYNTAX CfcmFcDataFieldSize MAX-ACCESS read-only STATUS current DESCRIPTION "The Receive Data Field Size which the Fx_Port has agreed to support for Class 3 frames to/from this Nx_Port. The size specifies the largest Data Field Size for an FT_1 frame. This is only meaningful if Class 3 service has been agreed." ::= { cfcmFLoginEntry 10 } --******************************** -- The Link table -- -- This table is intended to assist management applications -- in determining the topology of the network. The table -- contains any recent information which the agent knows -- about Fibre Channel links, both those which terminate at -- a local port, as well as any others for which information -- is known. cfcmLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF CfcmLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing any Fibre Channel link information which is known to local Fibre Channel managed instances. One end of such a link is typically at a local port, but the table can also contain information on links for which neither end is a local port. If one end of a link terminates locally, then that end is termed 'end1'; the other end is termed 'end2'." ::= { cfcmgmtObjects 10 } cfcmLinkEntry OBJECT-TYPE SYNTAX CfcmLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information which a particular Fibre Channel managed instance has about a Fibre Channel link. The two ends of the link are called 'end1' and 'end2'." INDEX { cfcmInstanceIndex, cfcmLinkIndex } ::= { cfcmLinkTable 1 } CfcmLinkEntry ::= SEQUENCE { cfcmLinkIndex Unsigned32, cfcmLinkEnd1NodeWwn CfcmFcNameIdOrZero, cfcmLinkEnd1PhysPortNumber Unsigned32, cfcmLinkEnd1PortWwn CfcmFcNameIdOrZero, cfcmLinkEnd2NodeWwn CfcmFcNameIdOrZero, cfcmLinkEnd2PhysPortNumber Unsigned32, cfcmLinkEnd2PortWwn CfcmFcNameIdOrZero, cfcmLinkEnd2AgentAddress SnmpAdminString, cfcmLinkEnd2PortType CfcmFcPortType, cfcmLinkEnd2UnitType CfcmFcUnitFunctions, cfcmLinkEnd2FcAddressId CfcmFcAddressId } cfcmLinkIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer which uniquely identifies one link within the set of links about which a particular managed instance has information." ::= { cfcmLinkEntry 1 } cfcmLinkEnd1NodeWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The node name of end1, or the zero-length string if unknown." ::= { cfcmLinkEntry 2 } cfcmLinkEnd1PhysPortNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The physical port number of end1, or zero if unknown." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.2.5" ::= { cfcmLinkEntry 3 } cfcmLinkEnd1PortWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The port WWN of end1, or the zero-length string if unknown. ('end1' is local if this value is equal to the value of cfcmPortWwn in one of the rows of the cfcmPortTable.)" ::= { cfcmLinkEntry 4 } cfcmLinkEnd2NodeWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The node name of end2, or the zero-length string if unknown." ::= { cfcmLinkEntry 5 } cfcmLinkEnd2PhysPortNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The physical port number of end2, or zero if unknown." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.2.5" ::= { cfcmLinkEntry 6 } cfcmLinkEnd2PortWwn OBJECT-TYPE SYNTAX CfcmFcNameIdOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "The port WWN of end2, or the zero-length string if unknown." ::= { cfcmLinkEntry 7 } cfcmLinkEnd2AgentAddress OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The address of the SNMP agent for the Fibre Channel Interconnect Element or Platform of which end2 is a part. If the address is unknown, the value of this object is the zero-length string." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.1.7" ::= { cfcmLinkEntry 8 } cfcmLinkEnd2PortType OBJECT-TYPE SYNTAX CfcmFcPortType MAX-ACCESS read-only STATUS current DESCRIPTION "The port type of end2." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sect 6.1.2.2.2" ::= { cfcmLinkEntry 9 } cfcmLinkEnd2UnitType OBJECT-TYPE SYNTAX CfcmFcUnitFunctions MAX-ACCESS read-only STATUS current DESCRIPTION "The type of/function(s) performed by the Fibre Channel Interconnect Element or Platform of which end2 is a part." REFERENCE "FC-GS-3 Rev 7.01, 28 Nov 2000, sections 6.1.2.1.2 and 6.1.2.3.2" ::= { cfcmLinkEntry 10 } cfcmLinkEnd2FcAddressId OBJECT-TYPE SYNTAX CfcmFcAddressId MAX-ACCESS read-only STATUS current DESCRIPTION "The Fibre Channel Address ID of end2, or the zero-length string if unknown." ::= { cfcmLinkEntry 11 } --******************************** -- Conformance Section -- cfcmgmtCompliances OBJECT IDENTIFIER ::= { cfcmgmtConformance 1 } cfcmgmtGroups OBJECT IDENTIFIER ::= { cfcmgmtConformance 2 } cfcmgmtCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Describes the requirements for compliance to this Fibre Channel Management MIB." MODULE -- this module MANDATORY-GROUPS { cfcmInstanceBasicGroup, cfcmPortBasicGroup, cfcmPortStatsGroup, cfcmPortErrorsGroup } GROUP cfcmPortClass23StatsGroup DESCRIPTION "This group is mandatory only for systems which keep class-specific traffic statistics on Class 2 on Class 3 traffic." GROUP cfcmPortClassFStatsGroup DESCRIPTION "This group is mandatory only for FC switches which keep statistics on Class F traffic." GROUP cfcmPortLcStatsGroup DESCRIPTION "This group is mandatory only for agents which do not provide Counter64 counters." GROUP cfcmSwitchBasicGroup DESCRIPTION "This group is mandatory only for Fibre Channel managed instances which manage Fibre Channel switches." GROUP cfcmSwitchPortGroup DESCRIPTION "This group is mandatory only for Fibre Channel managed instances which manage Fibre Channel switches." GROUP cfcmSwitchLoginGroup DESCRIPTION "This group is mandatory only for Fibre Channel managed instances which manage Fibre Channel switches." OBJECT cfcmInstancePhysicalIndex SYNTAX INTEGER (0) DESCRIPTION "Implementation of a non-zero value is not required." OBJECT cfcmInstanceSoftwareIndex SYNTAX Integer32 (0) DESCRIPTION "Implementation of a non-zero value is not required." OBJECT cfcmInstanceTextName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT cfcmInstanceDescr MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT cfcmPortAdminType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT cfcmPortAdminSpeed MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT cfcmSwitchDomainId MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT cfcmISPortClassFCredit MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { cfcmgmtCompliances 1 } --******************************** -- Object Groups -- cfcmInstanceBasicGroup OBJECT-GROUP OBJECTS { cfcmInstanceWwn, cfcmInstanceFunctions, cfcmInstancePhysicalIndex, cfcmInstanceSoftwareIndex, cfcmInstanceStatus, cfcmInstanceTextName, cfcmInstanceDescr, cfcmInstanceFabricId } STATUS current DESCRIPTION "Basic information about Fibre Channel managed instances." ::= { cfcmgmtGroups 1 } cfcmSwitchBasicGroup OBJECT-GROUP OBJECTS { cfcmSwitchDomainId, cfcmSwitchPrincipal } STATUS current DESCRIPTION "Basic information about Fibre Channel switches." ::= { cfcmgmtGroups 2 } cfcmPortBasicGroup OBJECT-GROUP OBJECTS { cfcmPortInstanceIndex, cfcmPortWwn, cfcmPortNodeWwn, cfcmPortAdminType, cfcmPortOperType, cfcmPortFcCapClass, cfcmPortFcOperClass, cfcmPortTransmitterType, cfcmPortConnectorType, cfcmPortSerialNumber, cfcmPortPhysicalNumber, cfcmPortAdminSpeed, cfcmPortCapProtocols, cfcmPortOperProtocols } STATUS current DESCRIPTION "Basic information about Fibre Channel ports." ::= { cfcmgmtGroups 3 } cfcmPortStatsGroup OBJECT-GROUP OBJECTS { cfcmPortBBCreditZeros, cfcmPortFullInputBuffers } STATUS current DESCRIPTION "Traffic statistics, which are not specific to any one class of service, for Fibre Channel ports." ::= { cfcmgmtGroups 4 } cfcmPortClass23StatsGroup OBJECT-GROUP OBJECTS { cfcmPortClass2RxFrames, cfcmPortClass2RxOctets, cfcmPortClass2TxFrames, cfcmPortClass2TxOctets, cfcmPortClass2Discards, cfcmPortClass2RxFbsyFrames, cfcmPortClass2RxPbsyFrames, cfcmPortClass2RxFrjtFrames, cfcmPortClass2RxPrjtFrames, cfcmPortClass2TxFbsyFrames, cfcmPortClass2TxPbsyFrames, cfcmPortClass2TxFrjtFrames, cfcmPortClass2TxPrjtFrames, cfcmPortClass3RxFrames, cfcmPortClass3RxOctets, cfcmPortClass3TxFrames, cfcmPortClass3TxOctets, cfcmPortClass3Discards } STATUS current DESCRIPTION "Traffic statistics for Class 2 and Class 3 traffic on Fibre Channel ports." ::= { cfcmgmtGroups 5 } cfcmPortClassFStatsGroup OBJECT-GROUP OBJECTS { cfcmPortClassFRxFrames, cfcmPortClassFRxOctets, cfcmPortClassFTxFrames, cfcmPortClassFTxOctets, cfcmPortClassFDiscards } STATUS current DESCRIPTION "Traffic statistics for Class F traffic on Fibre Channel ports." ::= { cfcmgmtGroups 6 } cfcmPortLcStatsGroup OBJECT-GROUP OBJECTS { cfcmPortLcBBCreditZeros, cfcmPortLcFullInputBuffers, cfcmPortLcClass2RxFrames, cfcmPortLcClass2RxOctets, cfcmPortLcClass2TxFrames, cfcmPortLcClass2TxOctets, cfcmPortLcClass2Discards, cfcmPortLcClass3Discards, cfcmPortLcClass3RxFrames, cfcmPortLcClass3RxOctets, cfcmPortLcClass3TxFrames, cfcmPortLcClass3TxOctets, cfcmPortLcClass2RxFbsyFrames, cfcmPortLcClass2RxPbsyFrames, cfcmPortLcClass2RxFrjtFrames, cfcmPortLcClass2RxPrjtFrames, cfcmPortLcClass2TxFbsyFrames, cfcmPortLcClass2TxPbsyFrames, cfcmPortLcClass2TxFrjtFrames, cfcmPortLcClass2TxPrjtFrames } STATUS current DESCRIPTION "Low-capacity (32-bit) statistics for Fibre Channel ports." ::= { cfcmgmtGroups 7 } cfcmPortErrorsGroup OBJECT-GROUP OBJECTS { cfcmPortRxLinkResets, cfcmPortTxLinkResets, cfcmPortLinkResets, cfcmPortRxOfflineSequences, cfcmPortTxOfflineSequences, cfcmPortLinkFailures, cfcmPortLossofSynchs, cfcmPortLossofSignals, cfcmPortPrimSeqProtocolErrors, cfcmPortInvalidTxWords, cfcmPortInvalidCRCs, cfcmPortInvalidOrderedSets, cfcmPortFrameTooLongs, cfcmPortTruncatedFrames, cfcmPortAddressErrors, cfcmPortDelimiterErrors, cfcmPortEncodingDisparityErrors, cfcmPortOtherErrors } STATUS current DESCRIPTION "Error statistics for Fibre Channel ports." ::= { cfcmgmtGroups 8 } cfcmSwitchPortGroup OBJECT-GROUP OBJECTS { cfcmFxPortRatov, cfcmFxPortEdtov, cfcmFxPortRttov, cfcmFxPortHoldTime, cfcmFxPortCapBbCreditMax, cfcmFxPortCapBbCreditMin, cfcmFxPortCapDataFieldSizeMax, cfcmFxPortCapDataFieldSizeMin, cfcmFxPortCapClass2SeqDeliv, cfcmFxPortCapClass3SeqDeliv, cfcmFxPortCapHoldTimeMax, cfcmFxPortCapHoldTimeMin, cfcmISPortClassFCredit, cfcmISPortClassFDataFieldSize } STATUS current DESCRIPTION "Information about ports on a Fibre Channel switch." ::= { cfcmgmtGroups 9 } cfcmSwitchLoginGroup OBJECT-GROUP OBJECTS { cfcmFLoginPortWwn, cfcmFLoginNodeWwn, cfcmFLoginBbCreditModel, cfcmFLoginBbCredit, cfcmFLoginClassesAgreed, cfcmFLoginClass2SeqDelivAgreed, cfcmFLoginClass2DataFieldSize, cfcmFLoginClass3SeqDelivAgreed, cfcmFLoginClass3DataFieldSize } STATUS current DESCRIPTION "Information known to a Fibre Channel switch about attached/logged-in Nx_Ports." ::= { cfcmgmtGroups 10 } cfcmLinkBasicGroup OBJECT-GROUP OBJECTS { cfcmLinkEnd1NodeWwn , cfcmLinkEnd1PhysPortNumber, cfcmLinkEnd1PortWwn, cfcmLinkEnd2NodeWwn , cfcmLinkEnd2PhysPortNumber, cfcmLinkEnd2PortWwn, cfcmLinkEnd2AgentAddress, cfcmLinkEnd2PortType, cfcmLinkEnd2UnitType, cfcmLinkEnd2FcAddressId } STATUS current DESCRIPTION "Information about Fibre Channel links." ::= { cfcmgmtGroups 11 } END