-- ***************************************************************** -- ciscoDs3 MIB - The MIB for DS3/E3 Interface -- -- January 1999, Shilpa Kale -- -- February 2000, Subra Hegde -- -- October 2000, Subra Hegde -- -- August 2001, Ramakumara Kariyappa -- -- Copyright (c) 1999-2002 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** CISCO-DS3-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Unsigned32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB ciscoMgmt FROM CISCO-SMI; ciscoDs3MIB MODULE-IDENTITY LAST-UPDATED "200205210000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com" DESCRIPTION "The MIB module to describe DS3 line objects. This is an extension to the standard DS3 MIB(RFC 2496)." REVISION "200205210000Z" DESCRIPTION "1. Added enumeration notApplicable(3) to following objects: cds3LineAIScBitsCheck, cds3LineOOFCriteria. 2. Imported Unsigned32 from SNMPv2-SMI instead of CISCO-TC." REVISION "200108310000Z" DESCRIPTION "Following enumerations are added to cds3LineType object: ds3cbitfrmronly, ds3m23frmronly, e3g832frmronly and e3g751frmronly." REVISION "200010100000Z" DESCRIPTION "Following enumerations are added to cds3LineType object: dsx3M23, dsx3SYNTRAN, dsx3CbitParity, dsx3ClearChannel, e3Framed, e3Plcp." REVISION "200002280000Z" DESCRIPTION "Initial version of this MIB Module." ::= { ciscoMgmt 132 } ciscoDs3MIBObjects OBJECT IDENTIFIER ::= { ciscoDs3MIB 1 } -- Ds3 Config cds3Config OBJECT IDENTIFIER ::= { ciscoDs3MIBObjects 1 } cds3Alarm OBJECT IDENTIFIER ::= { ciscoDs3MIBObjects 2 } cds3Stats OBJECT IDENTIFIER ::= { ciscoDs3MIBObjects 3 } cds3AlarmConfig OBJECT IDENTIFIER ::= { cds3Alarm 1 } -- -------------------------------------------------------------- -- Group ds3Config -- This group contains DS3 line configuration objects. -- -------------------------------------------------------------- cds3ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 Configuration table. The table has objects for configuring a T3/E3 line." ::= { cds3Config 1 } cds3ConfigEntry OBJECT-TYPE SYNTAX Cds3ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table. There is an entry for each available T3/E3 line, with an ifType value of 'ds3'(30). By default, lines are disabled. 'ifAdmin' from ifTable must be used to up the line. The objects in this table can be modified only when the line is up." INDEX { ifIndex } ::= { cds3ConfigTable 1 } Cds3ConfigEntry ::= SEQUENCE { cds3LineType INTEGER, cds3LineAIScBitsCheck INTEGER, cds3LineRcvFEACValidation INTEGER, cds3LineOOFCriteria INTEGER, cds3TraceToTransmit DisplayString, cds3TraceToExpect DisplayString, cds3TraceAlarm INTEGER, cds3InternalEqualizer INTEGER, cds3NearEndLineLoopbackStatus Unsigned32, cds3FarEndLineLoopbackStatus Unsigned32 } cds3LineType OBJECT-TYPE SYNTAX INTEGER { ds3cbitadm(1), ds3cbitplcp(2), e3g832adm(3), e3g751adm(4), e3g751plcp(5), ds3m23adm(6), ds3m23plcp(7), other(8), dsx3M23(9), dsx3SYNTRAN(10), dsx3CbitParity(11), dsx3ClearChannel(12), e3Framed(13), e3Plcp(14), ds3cbitfrmronly(15), ds3m23frmronly(16), e3g832frmronly(17), e3g751frmronly(18) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The values, in sequence, describe: Following values are applicable to DS3 interfaces only. ds3cbitadm : Indicates C-BIT ADM mode ds3cbitplcp : Indicates C-BIT PLCP mode ds3m23adm : Indicates M23 ADM mode ds3m23plcp : Indicates M23 PLCP mode dsx3M23 : Refer ANSI T1.107-1988 [9] dsx3SYNTRAN : Refer ANSI T1.107-1988 [9] dsx3CbitParity : Refer ANSI T1.107-1988 [9] dsx3ClearChannel : Refer ANSI T1.107-1988 [9] ds3cbitfrmronly : Indicates C-BIT FRAMER-ONLY mode ds3m23frmronly : Indicates M23 FRAMER-ONLY mode Following values are applicable to E3 interfaces only. e3g832adm : Indicates G.832 ADM mode e3g751adm : Indicates G.751 ADM mode e3g751plcp : Indicates G.751 PLCP mode e3Framed : Refer CCITT G.751 [12] e3Plcp : Refer ETSI T/NA(91)19 [14] e3g832frmronly : Indicates G.832 FRAMER-ONLY mode e3g751frmronly : Indicates G.751 FRAMER-ONLY mode." REFERENCE "ANSI T1.107, ANSI T1.102, CCITT G.751, ETSI T/NA(91)18" ::= { cds3ConfigEntry 1 } cds3LineAIScBitsCheck OBJECT-TYPE SYNTAX INTEGER { check(1), ignore(2), notApplicable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When check(1) is set, then Alarm Indication Signal (AIS) is declared when '1010...'b is found and C-Bits are all zero. When ignore(2) is set, an AIS condition is declared when the '1010...'b is detected irrespective of the state of the C-Bits. Does not apply to the E3 interface. The value notApplicable(3) is used in case of the interfaces where this object is not applicable. The notApplicable(3) is not allowed in write operation." REFERENCE "RFC2496" ::= { cds3ConfigEntry 2 } cds3LineRcvFEACValidation OBJECT-TYPE SYNTAX INTEGER{ fEACCodes4Of5(1), fEACCodes8Of10(2), disable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the FEAC (Far End Alarm and Control) code validation criteria. If 'fEACCodes4Of5' is specified, then a valid FEAC code is declared if 4 of 5 codes match. When 'fEACCodes8Of10' is specified, then a valid FEAC code is declared when 8 of 10 codes match. If disable(3) is specified, then FEAC code generation and detection is disabled. Does not apply to the E3 interface." DEFVAL {fEACCodes4Of5} ::= { cds3ConfigEntry 3 } cds3LineOOFCriteria OBJECT-TYPE SYNTAX INTEGER { bits3Of8(1), bits3Of16(2), notApplicable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry specifies the out of frame(OOF) decision criteria. If 'bits3Of8' is specified then an OOF condition is declared if at least 3 of 8 framing bits are in error. When 'bits3Of16' is specified then OOF is declared if 3 of 16 framing bits are found to be in error. OOF is declared when errors are detected in the framing octets for four consecutive frames. This object does not apply to E3 interface. The value notApplicable(3) is used in case of the interfaces where this object is not applicable. The notApplicable(3) is not allowed in write operation." DEFVAL {bits3Of8} ::= { cds3ConfigEntry 4 } cds3TraceToTransmit OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Transmitted G.832 Trail Trace string." REFERENCE "GR-253-CORE" ::= { cds3ConfigEntry 5 } cds3TraceToExpect OBJECT-TYPE SYNTAX DisplayString (SIZE (1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "G.832 Trail Trace string that is expected to be received from the other end." REFERENCE "GR-253-CORE" ::= { cds3ConfigEntry 6 } cds3TraceAlarm OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), traceFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object is set to traceFailure(2) when DS3 line receives a trace does not match the 'cds3TraceToExpect'." REFERENCE "GR-253-CORE" ::= { cds3ConfigEntry 7 } cds3InternalEqualizer OBJECT-TYPE SYNTAX INTEGER { use(1), byPass(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates whether the internal equalizer is being used or bypassed. Set this value depending on the line equipment to which the receiver is attached. Possible values are : use(1) : Use the internal equalizer byPass(2) : bypass internal equalizer(use external equalizer). This option allows easy interfacing of the device into systems already utilizing the external equalizers." DEFVAL { use } ::= { cds3ConfigEntry 8 } cds3NearEndLineLoopbackStatus OBJECT-TYPE SYNTAX Unsigned32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the loopback status of the near end DS1 on this DS3 when loopback request is indicated. Following table lists the mapping of Bit position to DS1 or DS3 lines and the value. Bit Position Line number value ---------------------------------------- 0 DS3 Line 0 = no loop(loop down) 1 = loop(loop up) 1 DS1 line 1 0 = loop down 1 = loop up 2 DS1 line 2 0 = loop down 1 = loop up 3 DS1 line 3 0 = loop down 1 = loop up ... ... 28 DS1 line 28 0 = loop down 1 = loop up 29 all DS1 lines 0 = loop up 1 = loop down " ::= { cds3ConfigEntry 9 } cds3FarEndLineLoopbackStatus OBJECT-TYPE SYNTAX Unsigned32(0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the loopback status of the far end DS3,DS1 when remote DS1 loopback request is initiated. The remote DS1 loopback is initiated by setting dsx3SendCode object to dsx3SendDS1LoopCode(5). For unchannelized DS3 applications DS1s are unassigned. Following table lists the mapping of Bit position to DS1 or DS3 lines and the value. Bit Position Line number value ---------------------------------------- 0 DS3 Line 0 = line loopback activate 1 = line loopback deactivate 1 DS1 line 1 0 = loop down 1 = loop up 2 DS1 line 2 0 = loop down 1 = loop up 3 DS1 line 3 0 = loop down 1 = loop up ... ... 28 DS1 line 29 0 = loop down 1 = loop up 29 all DS1 lines 0 = loop down 1 = loop up " ::= { cds3ConfigEntry 10 } -- -------------------------------------------------------------- -- -- Group cds3AlarmConfig -- -- -------------------------------------------------------------- cds3AlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3AlarmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 interface alarm configuration table. This table contains the parameters associated with detecting and declaring alarms for the interface. The parameters include severity of alarm, alarm integration parameters and 15 minute and 24 hour thresholds." ::= { cds3AlarmConfig 1 } cds3AlarmConfigEntry OBJECT-TYPE SYNTAX Cds3AlarmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the T3/E3 Alarm Configuration Table. The entries are automatically created for an ifType value of 'ds3'(30), with default values for objects. Thresholds may be configured for: Line Code Violations(LCV), LineErrored Seconds(LES), Line Severely Errored Seconds(LSES), P-bit Coding Violations(PCV), P-bit Errored Seconds(PES), P-bit Severely Errored Seconds(PSES), Severely Errored Seconds(SES), Severely Errored Framing Seconds(SEFS), Unavailable Seconds(UAS), C-bit coding violations(CCV), C-bit errored seconds(CES), C-bit errored seconds(CSES). Once these thresholds are exceeded, minor or major alarms are raised. Please refer to RFC2496 for descriptions of these errors." INDEX { ifIndex } ::= { cds3AlarmConfigTable 1 } Cds3AlarmConfigEntry ::= SEQUENCE { cds3NEAlarmUpCount Unsigned32, cds3NEAlarmDownCount Unsigned32, cds3NEAlarmThreshold Unsigned32, cds3FEAlarmUpCount Unsigned32, cds3FEAlarmDownCount Unsigned32, cds3FEAlarmThreshold Unsigned32, cds3StatisticalAlarmSeverity INTEGER, cds3LCV15MinThreshold Unsigned32, cds3LCV24HrThreshold Unsigned32, cds3LES15MinThreshold Unsigned32, cds3LES24HrThreshold Unsigned32, cds3PCV15MinThreshold Unsigned32, cds3PCV24HrThreshold Unsigned32, cds3PES15MinThreshold Unsigned32, cds3PES24HrThreshold Unsigned32, cds3PSES15MinThreshold Unsigned32, cds3PSES24HrThreshold Unsigned32, cds3SEFS15MinThreshold Unsigned32, cds3SEFS24HrThreshold Unsigned32, cds3UAS15MinThreshold Unsigned32, cds3UAS24HrThreshold Unsigned32, cds3CCV15MinThreshold Unsigned32, cds3CCV24HrThreshold Unsigned32, cds3CES15MinThreshold Unsigned32, cds3CES24HrThreshold Unsigned32, cds3CSES15MinThreshold Unsigned32, cds3CSES24HrThreshold Unsigned32, cds3LSES15MinThreshold Unsigned32, cds3LSES24HrThreshold Unsigned32, cds3LineStatisticalAlarmState Unsigned32 } cds3NEAlarmUpCount OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared." DEFVAL {6} ::= { cds3AlarmConfigEntry 1 } cds3NEAlarmDownCount OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The Default value is 1 and the integration counter is decremented by this value every 10 ms while no alarm persists. The counter is incremented by the value of cds3NEAlarmUpCount while there is no alarm (the counter does not decrement below zero). When the integration counter reaches zero any Alarm previously declared is removed." DEFVAL {1} ::= { cds3AlarmConfigEntry 2 } cds3NEAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value that the alarm integration counter must reach for an near end alarm to be declared. If the up count is 6, and the threshold 150, an Alarm is integrated in 2.5 seconds. If the down count is 1, then alarm will be cleared in 15 seconds." DEFVAL {150} ::= { cds3AlarmConfigEntry 3 } cds3FEAlarmUpCount OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the increment to the Far End alarm integration counters. The alarms are Remote Alarm Indication (RAI) and Alarm Indication Signal(AIS). The integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by this value while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds cds3FEAlarmThreshold an Alarm of the severity specified for the particular far end alarm is declared." DEFVAL {6} ::= { cds3AlarmConfigEntry 4 } cds3FEAlarmDownCount OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the decrement to the Far End alarm integration counters. The alarms are Alarm Indication Signal (AIS) and Remote Alarm Indication (RAI). The integration counter is decremented by this value every 10 ms (till zero), while no alarm persists. The counter is incremented by this value while there is no alarm. When the integration counter decrements to zero any previously declared Alarm is removed." DEFVAL {1} ::= { cds3AlarmConfigEntry 5 } cds3FEAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value that the alarm integration counter must reach for an far end Alarm to be declared. If the up count is 6, the down count is 1 and the threshold 150, an Alarm is integrated in 2.5 sec and removed in 15 seconds." DEFVAL {150} ::= { cds3AlarmConfigEntry 6 } cds3StatisticalAlarmSeverity OBJECT-TYPE SYNTAX INTEGER { minor(1), major(2), none(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to setup the severity of any of the Statistical alarms. So when a Statistical Counter exceeds its specified threshold the system will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised." DEFVAL { none } ::= { cds3AlarmConfigEntry 7 } cds3LCV15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 8 } cds3LCV24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 9 } cds3LES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes which when exceeded in a 15 minute window causes a statistical alarm to be declared." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 10 } cds3LES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 11 } cds3PCV15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 12 } cds3PCV24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 13 } cds3PES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 14 } cds3PES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 15 } cds3PSES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 16 } cds3PSES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 17 } cds3SEFS15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 18 } cds3SEFS24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval" REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 19 } cds3UAS15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 20 } cds3UAS24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval" REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 21 } cds3CCV15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 22 } cds3CCV24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 23 } cds3CES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 24 } cds3CES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 25 } cds3CSES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 26 } cds3CSES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3." REFERENCE "RFC2496" ::= { cds3AlarmConfigEntry 27 } cds3LSES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to set the 15 minute threshold for LSES(Line Severely Errored Seconds). The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." REFERENCE "Bellcore TR-TSV-000773" ::= { cds3AlarmConfigEntry 28 } cds3LSES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared." REFERENCE "Bellcore TR-TSV-000773" ::= { cds3AlarmConfigEntry 29 } cds3LineStatisticalAlarmState OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a bitmap of the DS3 Line Statistical alarms. It is represented as a sum where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. Zero indicates no alarms. Itemized below are the individual alarm bits: BitPosition Alarm ----------- ----- 1 PES current 15 minute threshold exceeded 2 PES 24 hour threshold exceeded 3 PSES current 15 minute threshold exceeded 4 PSES 24 hour threshold exceeded 5 SEFS current 15 minute threshold exceeded 6 SEFS 24 hour threshold exceeded 7 UAS current 15 minute threshold exceeded 8 UAS 24 hour threshold exceeded 9 LCV current 15 minute threshold exceeded 10 LCV 24 hour threshold exceeded 11 PCV current 15 minute threshold exceeded 12 PCV 24 hour threshold exceeded 13 LES current 15 minute threshold exceeded 14 LES 24 hour threshold exceeded 15 CCV current 15 minute threshold exceeded 16 CCV 24 hour threshold exceeded 17 CES current 15 minute threshold exceeded 18 CES 24 hour threshold exceeded 19 CSES current 15 minute threshold exceeded 20 CSES 24 hour threshold exceeded 21 LSES current 15 minute threshold exceeded 22 LSES 24 hour threshold exceeded" DEFVAL {0} ::= { cds3AlarmConfigEntry 30 } -- -------------------------------------------------------------- -- -- Group cds3Stats -- -- -------------------------------------------------------------- cds3StatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3StatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "T3/E3 Statistics table. This table maintains the number of times the line encountered Loss of Signal(LOS), out of frame(LOF), Alarm Indication signals(AIS), Remote alarm indications(RAI), C-bit coding violations(CCV), Framing Errors(FE), from the time it is up. Line fails and goes down as a result of failures. When the line is brought back up again by the user the error statistics are cleared." ::= { cds3Stats 1 } cds3StatsEntry OBJECT-TYPE SYNTAX Cds3StatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the T3/E3 Statistics table. Statistics are gathered for each existing T3/E3 line. An entry is created automatically for each T3/E3 line that is activated." INDEX { ifIndex } ::= { cds3StatsTable 1 } Cds3StatsEntry ::= SEQUENCE { cds3RcvLOSCount Counter32, cds3RcvOOFCount Counter32, cds3RAICount Counter32, cds3CCVCount Counter32, cds3FECount Counter32, cds3EXZSCount Counter32, cds3LCVCount Counter32, cds3PCVCount Counter32, cds3CPECount Counter32, cds3FEBECount Counter32, cds3RcvAISCount Counter32 } cds3RcvLOSCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times Loss of Signal was detected with or without integrating to LOS alarm." ::= { cds3StatsEntry 1 } cds3RcvOOFCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times Out of Frame was detected with or without integrating to OOF alarm." ::= { cds3StatsEntry 2 } cds3RAICount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of timesRemote Alarm Indication was detected with or without integrating to RAI alarm." ::= { cds3StatsEntry 3 } cds3CCVCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of C-Bit Coding Violations encountered by a T3/E3 interface." ::= { cds3StatsEntry 4 } cds3FECount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Framing Errors encountered by a T3/E3 interface." ::= { cds3StatsEntry 5 } cds3EXZSCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Excessive Zeros(EXZ) by a T3/E3 interface. An EXZ is the occurrence of any string of zeros having length equal to or greater than 3 for B3ZS, or any string of zeros having length greater than 4 for HDB3." REFERENCE "RFC2496 Section 2.4.1." ::= { cds3StatsEntry 6 } cds3LCVCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of both BPVs(Bipolar Violations) and EXZs(Excessive Zeros) encountered by a T3/E3 interface.An EXZ increments the LCV by one regardless of the length of the zero string." REFERENCE "RFC2496 Section 2.4.1." ::= { cds3StatsEntry 7 } cds3PCVCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the count of P-bit Coding Violation(PCV) error event encountered by DS3 interface. For all DS3 applications, a coding violation error event is a P-bit Parity Error(PERR) event. The parity errors occur when the calculated parity in the information bits of the DS3 frame does not match up with an expected parity value." REFERENCE "RFC2496 Section 2.4.1." ::= { cds3StatsEntry 8 } cds3CPECount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of C-bit parity errors(CPERR) on a DS3 interface. This value is calculated over noninformation bits in the DS3 frame." ::= { cds3StatsEntry 9 } cds3FEBECount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Block Errors(FEBE) encountered by a T3/E3 interface.These include frame alignment errors, multiframe alignment errors, and C-bit parity errors. These errors are generated by the transmitter at the far end, and indicate that the transmitter,cabling or the upstream node is faulty." ::= { cds3StatsEntry 10 } cds3RcvAISCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times Alarm Indication Signals(AIS) were detected. The AIS indicates that an upstream failure has been detected by the far end." REFERENCE "RFC2496 Section 2.4.3." ::= { cds3StatsEntry 11 } -- -------------------------------------------------------------- -- -- Group cds3PlcpAlarmConfig -- -- -------------------------------------------------------------- cds3AlarmConfigPlcpTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3AlarmConfigPlcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ATM interface PLCP alarm configuration table. PLCP is a sublayer over the DS3 interface, that carries ATM cells." ::= { cds3AlarmConfig 2 } cds3AlarmConfigPlcpEntry OBJECT-TYPE SYNTAX Cds3AlarmConfigPlcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 PLCP Alarm Configuration table. The entries contain parameters to configure DS3 PLCP error statistics thresholds, so that an alarm is raised whenever any threshold is exceeded. The entries are automatically created for active DS3 interfaces with Plcp framing enabled, with default values for objects." INDEX { ifIndex } ::= { cds3AlarmConfigPlcpTable 1 } Cds3AlarmConfigPlcpEntry ::= SEQUENCE { cds3PlcpStatisticalAlarmSeverity INTEGER, cds3PlcpBip8CV15MinThreshold Unsigned32, cds3PlcpBip8CV24HrThreshold Unsigned32, cds3PlcpBip8ES15MinThreshold Unsigned32, cds3PlcpBip8ES24HrThreshold Unsigned32, cds3PlcpBip8SES15MinThreshold Unsigned32, cds3PlcpBip8SES24HrThreshold Unsigned32, cds3PlcpSEFS15MinThreshold Unsigned32, cds3PlcpSEFS24HrThreshold Unsigned32, cds3PlcpUAS15MinThreshold Unsigned32, cds3PlcpUAS24HrThreshold Unsigned32 } cds3PlcpStatisticalAlarmSeverity OBJECT-TYPE SYNTAX INTEGER { minor(1), major(2), none(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable sets up the severity of PLCP Statistical alarm. So when PLCP Statistical alarm is detected the module will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised." DEFVAL { none } ::= { cds3AlarmConfigPlcpEntry 1 } cds3PlcpBip8CV15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." ::= { cds3AlarmConfigPlcpEntry 2 } cds3PlcpBip8CV24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval." ::= { cds3AlarmConfigPlcpEntry 3 } cds3PlcpBip8ES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." ::= { cds3AlarmConfigPlcpEntry 4 } cds3PlcpBip8ES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval." ::= { cds3AlarmConfigPlcpEntry 5 } cds3PlcpBip8SES15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." ::= { cds3AlarmConfigPlcpEntry 6 } cds3PlcpBip8SES24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval." ::= { cds3AlarmConfigPlcpEntry 7 } cds3PlcpSEFS15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." ::= { cds3AlarmConfigPlcpEntry 8 } cds3PlcpSEFS24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval." ::= { cds3AlarmConfigPlcpEntry 9 } cds3PlcpUAS15MinThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared." ::= { cds3AlarmConfigPlcpEntry 10 } cds3PlcpUAS24HrThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval." ::= { cds3AlarmConfigPlcpEntry 11 } -- -------------------------------------------------------------- -- -- Group cds3PlcpAlarm group -- -- -------------------------------------------------------------- cds3AlarmPlcpTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3AlarmPlcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Plcp interface alarm table. This table maintains the CV,ES,SES, SEFS and UAS for DS3 line with Plcp framing selected. Please refer to RFC2496 for description of these various error statistics." ::= { cds3Alarm 2 } cds3AlarmPlcpEntry OBJECT-TYPE SYNTAX Cds3AlarmPlcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS3 Plcp Alarm table. Bucket statistics(15 minute and 24 hour interval statistics) are gathered for each existing DS3 line with PLCP frame format selected. An entry is created automatically and is indexed by the DS3 line number. " INDEX { ifIndex } ::= { cds3AlarmPlcpTable 1 } Cds3AlarmPlcpEntry ::= SEQUENCE { cds3PlcpLineAlarmState Unsigned32, cds3PlcpLineStatisticalAlarmState Unsigned32, cds3PlcpBip8CVCurrent Counter32, cds3PlcpBip8CV24HrBucket Counter32, cds3PlcpBip8ESCurrent Counter32, cds3PlcpBip8ES24HrBucket Counter32, cds3PlcpBip8SESCurrent Counter32, cds3PlcpBip8SES24HrBucket Counter32, cds3PlcpSEFSCurrent Counter32, cds3PlcpSEFS24HrBucket Counter32, cds3PlcpUASCurrent Counter32, cds3PlcpUAS24HrBucket Counter32 } cds3PlcpLineAlarmState OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is a bitmap of the DS3 Line ALarms. It is represented as sum where value 2^(N-1) is added to the sum if alarm corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are the individual bits: BitPosition Alarm ----------- ----- 1 Receiving RAI 2 Transmitting RAI 3 Receiving OOF 4 Near End Local Loopback in effect 5 Near End Remote Loopback in effect " ::= { cds3AlarmPlcpEntry 1 } cds3PlcpLineStatisticalAlarmState OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is a bitmap of the DS3 Plcp Line Statictical Alarms. It is represented as a sum, where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are the individual alarm bits: BitPosition Alarm ----------- ----- 1 Bip8CV 15 minute threshold exceeded 2 Bip8CV 24 hour threshold exceeded 3 Bip8ES 15 minute threshold exceeded 4 Bip8ES 24 hour threshold exceeded 5 Bip8SES 15 minute threshold exceeded 6 Bip8SES 24 hour threshold exceeded 7 Plcp SEFS 15 minute threshold exceeded 8 Plcp SEFS 24 hour threshold exceeded 9 Plcp UAS 15 minute threshold exceeded 10 Plcp UAS 24 hour threshold exceeded" ::= { cds3AlarmPlcpEntry 2 } cds3PlcpBip8CVCurrent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 code violations (CV) encountered by the line in the current 15 minute period." ::= { cds3AlarmPlcpEntry 3 } cds3PlcpBip8CV24HrBucket OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 CVs encountered by the line in the last 24 hours." ::= { cds3AlarmPlcpEntry 4 } cds3PlcpBip8ESCurrent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 Errored Seconds(ES) encountered by the line in the current 15 minute period." ::= { cds3AlarmPlcpEntry 5 } cds3PlcpBip8ES24HrBucket OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 ES encountered by the line in the last 24 hour." ::= { cds3AlarmPlcpEntry 6 } cds3PlcpBip8SESCurrent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 Severely Errored Seconds(ES) encountered by the line in the current 15 minute period." ::= { cds3AlarmPlcpEntry 7 } cds3PlcpBip8SES24HrBucket OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 SES encountered by the line in the last 24 hour." ::= { cds3AlarmPlcpEntry 8 } cds3PlcpSEFSCurrent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 Severely Errored Framing Seconds(SEFS) encountered by the line in the current 15-minute period." ::= { cds3AlarmPlcpEntry 9 } cds3PlcpSEFS24HrBucket OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 SEFS encountered by the line in the last 24 hour." ::= { cds3AlarmPlcpEntry 10 } cds3PlcpUASCurrent OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds(UAS) encountered by the line in the current 15-minute period." ::= { cds3AlarmPlcpEntry 11 } cds3PlcpUAS24HrBucket OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BIP-8 UAS encountered by the line in the last 24 hour." ::= { cds3AlarmPlcpEntry 12} -- -------------------------------------------------------------- -- -- Group ds3PlcpStats -- -- -------------------------------------------------------------- cds3PlcpStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3PlcpStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "T3 Plcp Statistics table. This table maintains the errors encountered by the T3 line with Plcp frame format selected, from the time the line is up.Line fails and goes down as a result of failures. When the line is brought back up again by the user after eliminating the error conditions, the statistics are cleared." ::= { cds3Stats 2 } cds3PlcpStatsEntry OBJECT-TYPE SYNTAX Cds3PlcpStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the T3 Plcp Stats table. Statistics are gathered for each existing T3 line with PLCP frame format selected. An entry is created automatically and is indexed by the T3 line number." INDEX { ifIndex } ::= { cds3PlcpStatsTable 1 } Cds3PlcpStatsEntry ::= SEQUENCE { cds3PlcpRcvBip8Count Counter32, cds3PlcpRcvOOFCount Counter32, cds3PlcpRcvRAICount Counter32, cds3PlcpFECount Counter32, cds3PlcpFESecCount Counter32, cds3PlcpSEFSecCount Counter32, cds3PlcpFEBECount Counter32, cds3PlcpFEBESecCount Counter32, cds3PlcpSEFEBESecCount Counter32 } cds3PlcpRcvBip8Count OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of of BIP-8 errors encountered by the line." ::= { cds3PlcpStatsEntry 1 } cds3PlcpRcvOOFCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times Out of Frame(OOF) was detected with or without integrating to OOF alarm." ::= { cds3PlcpStatsEntry 2 } cds3PlcpRcvRAICount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times Remote Alarm Indication(RAI) was detected with or without integrating to RAI alarm." ::= { cds3PlcpStatsEntry 3 } cds3PlcpFECount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Framing Errors detected." ::= { cds3PlcpStatsEntry 4 } cds3PlcpFESecCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Framing Error errored seconds." ::= { cds3PlcpStatsEntry 5 } cds3PlcpSEFSecCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely errored Framing error seconds." ::= { cds3PlcpStatsEntry 6 } cds3PlcpFEBECount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The count of Far End Block Errors (FEBE) detected." ::= { cds3PlcpStatsEntry 7 } cds3PlcpFEBESecCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FEBE errored seconds." ::= { cds3PlcpStatsEntry 8 } cds3PlcpSEFEBESecCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely errored FEBE seconds." ::= { cds3PlcpStatsEntry 9 } -- -------------------------------------------------------------- -- -- DS3 Interval table -- -- -------------------------------------------------------------- cds3IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 interface interval table." ::= { cds3Stats 4 } cds3IntervalEntry OBJECT-TYPE SYNTAX Cds3IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the T3/E3 current interval table." INDEX { ifIndex, cds3IntervalNumber } ::= { cds3IntervalTable 1 } Cds3IntervalEntry ::= SEQUENCE { cds3IntervalNumber INTEGER, cds3IntervalLSESs Counter32 } cds3IntervalNumber OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 0 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minute interval completed 23 hours and 45 minutes prior to interval number 1. Interval number 0 refers to the current 15 minute data." ::= { cds3IntervalEntry 1 } cds3IntervalLSESs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LSESs encountered by the line in 15 minute interval." ::= { cds3IntervalEntry 2 } -- -------------------------------------------------------------- -- -- Current 24 hour interval -- -- -------------------------------------------------------------- cds3Current24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3Current24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 interface current 24 hour table. This table contains counters for current 24 hour interval. Threshold on this counters are configured through cds3AlarmConfigTable table. 24 hour interval is aligned to wall clock." ::= { cds3Stats 5 } cds3Current24HrEntry OBJECT-TYPE SYNTAX Cds3Current24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of 'ds3'(30), when interface is made active." INDEX { ifIndex } ::= { cds3Current24HrTable 1 } Cds3Current24HrEntry ::= SEQUENCE { cds3LCVCurrent24Hr Counter32, cds3LESCurrent24Hr Counter32, cds3PCVCurrent24Hr Counter32, cds3PESCurrent24Hr Counter32, cds3PSESCurrent24Hr Counter32, cds3SEFSCurrent24Hr Counter32, cds3UASCurrent24Hr Counter32, cds3CCVCurrent24Hr Counter32, cds3CESCurrent24Hr Counter32, cds3CSESCurrent24Hr Counter32, cds3LSESCurrent24Hr Counter32 } cds3LCVCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LCVs encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 1 } cds3LESCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number LESs encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 2 } cds3PCVCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number PCVs encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 3 } cds3PESCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PESs encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 4 } cds3PSESCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PSESs encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 5 } cds3SEFSCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SEFSs encountered by the line since the start of the current 24 hour period." ::= { cds3Current24HrEntry 6 } cds3UASCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of UASs encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 7 } cds3CCVCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number CCVs encounterd by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 8 } cds3CESCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of CESs encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 9 } cds3CSESCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of CSESs encountered by the line since th start of current 24 hour period." ::= { cds3Current24HrEntry 10 } cds3LSESCurrent24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LSESs (Line severedly errored seconds) encountered by the line since the start of current 24 hour period." ::= { cds3Current24HrEntry 11 } -- -------------------------------------------------------------- -- -- Previous 24 hour interval data -- -- -------------------------------------------------------------- cds3Previous24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF Cds3Previous24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS3 interface previous 24 hour table. This table contains counters for previous 24 hour interval. Implementation of this table is optional." ::= { cds3Stats 6 } cds3Previous24HrEntry OBJECT-TYPE SYNTAX Cds3Previous24HrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of ds3(30), when interface is made active." INDEX { ifIndex } ::= { cds3Previous24HrTable 1 } Cds3Previous24HrEntry ::= SEQUENCE { cds3LCVPrevious24Hr Counter32, cds3LESPrevious24Hr Counter32, cds3PCVPrevious24Hr Counter32, cds3PESPrevious24Hr Counter32, cds3PSESPrevious24Hr Counter32, cds3SEFSPrevious24Hr Counter32, cds3UASPrevious24Hr Counter32, cds3CCVPrevious24Hr Counter32, cds3CESPrevious24Hr Counter32, cds3CSESPrevious24Hr Counter32, cds3LSESPrevious24Hr Counter32 } cds3LCVPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LCVs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 1 } cds3LESPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number LESs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 2 } cds3PCVPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number PCVs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 3 } cds3PESPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PESs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 4 } cds3PSESPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PSESs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 5 } cds3SEFSPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SEFSs encountered by the line in the start of the current 24 hour period." ::= { cds3Previous24HrEntry 6 } cds3UASPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of UASs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 7 } cds3CCVPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number CCVs encounterd by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 8 } cds3CESPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of CESs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 9 } cds3CSESPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of CSESs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 10 } cds3LSESPrevious24Hr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LSESs encountered by the line in the previous 24 hour period." ::= { cds3Previous24HrEntry 11 } -- conformance information ciscoDs3MIBConformance OBJECT IDENTIFIER ::= { ciscoDs3MIB 8 } ciscoDs3MIBCompliances OBJECT IDENTIFIER ::= { ciscoDs3MIBConformance 1 } ciscoDs3MIBGroups OBJECT IDENTIFIER ::= { ciscoDs3MIBConformance 2 } ciscoDs3MIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The Compliance statement for ciscoDs3 management group." MODULE -- this module MANDATORY-GROUPS { ciscoDs3ConfMIBGroup } GROUP cds3StatsMIBGroup DESCRIPTION "Implementation of this group is optional." GROUP ciscoDs3AlarmMIBGroup DESCRIPTION "Implementation of this group is optional." GROUP ciscoPlcpCounterMIBGroup DESCRIPTION "Implementation of this group is optional." GROUP ciscoDs3Previous24HrGroup DESCRIPTION "Implementation of this group is optional. ciscoDs3AlarmMIBGroup needs to be implemented for this group to be implemented." OBJECT cds3NearEndLineLoopbackStatus MIN-ACCESS not-accessible DESCRIPTION "Read access is not required for agents which can not provide the status of the near end loopback." OBJECT cds3FarEndLineLoopbackStatus MIN-ACCESS not-accessible DESCRIPTION "Read access is not required for agents which can not provide the status of the far end loopback." ::= { ciscoDs3MIBCompliances 1 } -- units of conformance ciscoDs3ConfMIBGroup OBJECT-GROUP OBJECTS { cds3LineType, cds3LineAIScBitsCheck, cds3LineRcvFEACValidation, cds3LineOOFCriteria, cds3TraceToTransmit, cds3TraceToExpect, cds3TraceAlarm, cds3InternalEqualizer, cds3NearEndLineLoopbackStatus, cds3FarEndLineLoopbackStatus } STATUS current DESCRIPTION "Collection of DS3/E3 line related configuration parameters." ::= { ciscoDs3MIBGroups 1} cds3StatsMIBGroup OBJECT-GROUP OBJECTS { cds3RcvLOSCount, cds3RcvOOFCount, cds3RAICount, cds3CCVCount, cds3FECount, cds3EXZSCount, cds3LCVCount, cds3PCVCount, cds3CPECount, cds3FEBECount, cds3RcvAISCount } STATUS current DESCRIPTION "Collection of DS3/E3 line related real time counters." ::= { ciscoDs3MIBGroups 2 } ciscoDs3AlarmMIBGroup OBJECT-GROUP OBJECTS { cds3NEAlarmUpCount, cds3NEAlarmDownCount, cds3NEAlarmThreshold, cds3FEAlarmUpCount, cds3FEAlarmDownCount, cds3FEAlarmThreshold, cds3StatisticalAlarmSeverity , cds3LCV15MinThreshold, cds3LCV24HrThreshold , cds3LES15MinThreshold, cds3LES24HrThreshold , cds3PCV15MinThreshold, cds3PCV24HrThreshold, cds3PES15MinThreshold, cds3PES24HrThreshold, cds3PSES15MinThreshold, cds3PSES24HrThreshold , cds3SEFS15MinThreshold, cds3SEFS24HrThreshold, cds3UAS15MinThreshold, cds3UAS24HrThreshold , cds3CCV15MinThreshold, cds3CCV24HrThreshold , cds3CES15MinThreshold, cds3CES24HrThreshold , cds3CSES15MinThreshold, cds3CSES24HrThreshold, cds3LSES15MinThreshold, cds3LSES24HrThreshold, cds3LineStatisticalAlarmState, cds3IntervalNumber, cds3IntervalLSESs, cds3LCVCurrent24Hr, cds3LESCurrent24Hr, cds3PCVCurrent24Hr, cds3PESCurrent24Hr, cds3PSESCurrent24Hr, cds3SEFSCurrent24Hr, cds3UASCurrent24Hr, cds3CCVCurrent24Hr, cds3CESCurrent24Hr, cds3CSESCurrent24Hr, cds3LSESCurrent24Hr } STATUS current DESCRIPTION "Collection of DS3/E3 related interval counters and threshold parameters." ::= { ciscoDs3MIBGroups 3 } ciscoPlcpCounterMIBGroup OBJECT-GROUP OBJECTS { cds3PlcpRcvBip8Count, cds3PlcpRcvOOFCount, cds3PlcpRcvRAICount, cds3PlcpFECount, cds3PlcpFESecCount, cds3PlcpSEFSecCount, cds3PlcpFEBECount, cds3PlcpFEBESecCount, cds3PlcpSEFEBESecCount } STATUS current DESCRIPTION "Collection of PLCP related real time counters." ::= { ciscoDs3MIBGroups 4 } ciscoPlcpAlarmMIBGroup OBJECT-GROUP OBJECTS { cds3PlcpStatisticalAlarmSeverity, cds3PlcpBip8CV15MinThreshold, cds3PlcpBip8CV24HrThreshold, cds3PlcpBip8ES15MinThreshold, cds3PlcpBip8ES24HrThreshold, cds3PlcpBip8SES15MinThreshold, cds3PlcpBip8SES24HrThreshold, cds3PlcpSEFS15MinThreshold, cds3PlcpSEFS24HrThreshold, cds3PlcpUAS15MinThreshold, cds3PlcpUAS24HrThreshold , cds3PlcpLineAlarmState , cds3PlcpLineStatisticalAlarmState, cds3PlcpBip8CVCurrent, cds3PlcpBip8CV24HrBucket, cds3PlcpBip8ESCurrent, cds3PlcpBip8ES24HrBucket, cds3PlcpBip8SESCurrent, cds3PlcpBip8SES24HrBucket, cds3PlcpSEFSCurrent, cds3PlcpSEFS24HrBucket, cds3PlcpUASCurrent, cds3PlcpUAS24HrBucket } STATUS current DESCRIPTION "Collection of PLCP related interval counters and threshold parameters." ::= { ciscoDs3MIBGroups 5 } ciscoDs3Previous24HrGroup OBJECT-GROUP OBJECTS { cds3LCVPrevious24Hr, cds3LESPrevious24Hr, cds3PCVPrevious24Hr, cds3PESPrevious24Hr, cds3PSESPrevious24Hr, cds3SEFSPrevious24Hr, cds3UASPrevious24Hr, cds3CCVPrevious24Hr, cds3CESPrevious24Hr, cds3CSESPrevious24Hr, cds3LSESPrevious24Hr } STATUS current DESCRIPTION "A collection DS3/E3 related previous 24 hour counters." ::= { ciscoDs3MIBGroups 6 } END