-- ***************************************************************** -- CISCO-CAT6K-CROSSBAR-MIB.my -- -- Mar 2001, Padma Pullela -- Nov. 2002, Padma Pullela/Lilian Jiang -- March 2003, Padma Pullela -- June 2004, Padma Pullela -- -- Copyright (c) 2001-2009, 2012-2013 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** CISCO-CAT6K-CROSSBAR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Unsigned32, Gauge32, NOTIFICATION-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION, TruthValue, DisplayString, DateAndTime, TimeStamp FROM SNMPv2-TC entPhysicalName, entPhysicalVendorType, entPhysicalIndex, entPhysicalDescr FROM ENTITY-MIB Percent FROM CISCO-QOS-PIB-MIB ciscoMgmt FROM CISCO-SMI; ciscoCat6kCrossbarMIB MODULE-IDENTITY LAST-UPDATED "201309160000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-cat6000@cisco.com" DESCRIPTION "The Catalyst 6000 Crossbar MIB provides instrumentation for configuration and operation of the crossbar switching fabric module, and additional functionalities for switching bus and internal bus, etc." REVISION "201309160000Z" DESCRIPTION "Added two new enumerations 'pfc4xxl' and 'pfc4lite' in cc6kxbarSysCapPfcOperMode." REVISION "201205310000Z" DESCRIPTION "Added following OBJECT-GROUP - cc6kxbarStatisticsLbusDropGroup Added new compliance - cc6kxbarMIBComplianceVer8. Updated the description for - cc6kxbarStatisticsPeakTmInUtil - cc6kxbarStatisticsPeakTmOutUtil." REVISION "200902150000Z" DESCRIPTION "Added cc6kxbarErrRcvryPersLinkResGroup and cc6kxbarErrRcvryChResyncGroup, cc6kxbarTMSwBusUtilGroup, cc6kxbarTMSwBusUtilNotifControlGroup, cc6kxbarTMSwBusUtilNotifObjectGroup, cc6kxbarTMSwBusUtilNotifGroup, cc6kxbarTMChUtilGroup, cc6kxbarTMChUtilNotifControlGroup, cc6kxbarTMChUtilNotifObjectGroup, cc6kxbarTMChUtilNotifGroup. Added two new enumerations 'pfc4' and 'pfc4xl' in cc6kxbarSysCapPfcOperMode. Added DISPLAY-HINT in TEXTUAL-CONVENTION of ModuleSlotNumber and FabricChannelNumber." REVISION "200712180000Z" DESCRIPTION "Added cc6kxbarSysCapPfcOperModeGroup, cc6kxbarSysCapSwitchResGroup, cc6kxbarChannelUtilGroup1, cc6kxbarSwBusGroup1, cc6kxbarErrorGroup, cc6kxbarErrRcvryThresholdGroup and cc6kxbarErrRcvrySwitchoverGroup." REVISION "200612190000Z" DESCRIPTION "Added cc6kxbarDcefOnlyModeAllowedGroup, cc6kxbarForceBusModeGroup, cc6kxbarFlowCtrlNotifCtrlGroup, cc6kxbarFlowCtrlBusThreshGroup, cc6kxbarFlowCtrlBusThrNotifGroup and cc6kxbarBusOnlyModeOperGroup." REVISION "200411190000Z" DESCRIPTION "Added cc6kxbarIntBusCRCErrGroup." REVISION "200408110000Z" DESCRIPTION "Added cc6kxbarIntBusNotifControlGroup and cc6kxbarIntBusCRCErrNotifGroup." REVISION "200406110000Z" DESCRIPTION "Added cc6kxbarTruncatedModeOper Object and changed the description of cc6kxbarTruncatedModeAllowed and cc6kxbarMinFabricPresent." REVISION "200309290000Z" DESCRIPTION "Changed the description of cc6kxbarTruncatedModeAllowed and cc6kxbarMinFabricPresent. Removed default value for cc6kxbarTruncatedModeAllowed." REVISION "200304020000Z" DESCRIPTION "Changed the SYNTAX and description of cc6kxbarMinFabricPresent and description of cc6kxbarTruncatedModeAllowed." REVISION "200212050000Z" DESCRIPTION "Added cc6kxbarModuleChannelSpeed, cc6kxbarSwBusSwitchingStatus, cc6kxbarSwBusFailureDuration, cc6kxbarSwBusNotifEnable objects and cc6kxbarSwBusStallNotif notification." REVISION "200106250000Z" DESCRIPTION "Initial version of this MIB module." ::= { ciscoMgmt 217 } ciscoCat6kXbarMIBObjects OBJECT IDENTIFIER ::= { ciscoCat6kCrossbarMIB 1 } cc6kxbarConfiguration OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 1 } cc6kxbarStatus OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 2 } cc6kxbarStatistics OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 3 } cc6kxbarSwBusObjects OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 4 } cc6kxbarIntBusObjects OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 5 } cc6kxbarFlowCtrlObjects OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 6 } cc6kxbarSystemCapacityObjects OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 7 } cc6kxbarErrorRecoveryObjects OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 8 } cc6kxbarTrafficMonitorObjects OBJECT IDENTIFIER ::= { ciscoCat6kXbarMIBObjects 9 } cc6kxbarTrafficMonitorSwBusObjects OBJECT IDENTIFIER ::= { cc6kxbarTrafficMonitorObjects 1 } cc6kxbarTrafficMonitorChObjects OBJECT IDENTIFIER ::= { cc6kxbarTrafficMonitorObjects 2 } -- Textual Conventions ModuleSlotNumber ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Slot number of the module." SYNTAX Unsigned32 FabricChannelNumber ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Fabric channel number." SYNTAX Unsigned32 ChannelStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Status of the Channel." SYNTAX INTEGER { ok(1), syncError(2), heartbeatError(3), crcError(4), bufferError(5), timeoutError(6), unused(7) } -- Configuration objects cc6kxbarFallbackMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "cc6kxbarFallbackMode controls system fallback to bus-mode after loss of switching fabric module. 'true' - When the last fabric card is removed system will adjust the supervisor and line cards switching mode automatically without resetting the system. With this feature enabled, the switch might lose traffic while it's changing the switching mode. 'false' - All the ports in the system will be disabled when the last fabric card is removed." DEFVAL { true } ::= { cc6kxbarConfiguration 1 } cc6kxbarBusOnlyModeAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether bus mode is administratively enabled on the device or not." ::= { cc6kxbarConfiguration 2 } cc6kxbarTruncatedModeAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether truncated mode is administratively enabled on the device or not." ::= { cc6kxbarConfiguration 3 } cc6kxbarMinFabricPresent OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the minimum number of switching fabric capable modules to be present in the system, for any switching fabric capable module to be in 'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode, when cc6kxbarTruncatedModeOper is 'false'." ::= { cc6kxbarConfiguration 4 } cc6kxbarLcdBannerTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarLcdBannerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "cc6kxbarLcdBannerTable configures the Lcd banner of the fabric module." ::= { cc6kxbarConfiguration 5 } cc6kxbarLcdBannerEntry OBJECT-TYPE SYNTAX Cc6kxbarLcdBannerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in cc6kxbarLcdBannerTable. Entries are created by the agent based on the size of the lcd banner." INDEX { cc6kxbarLcdBannerIndex } ::= { cc6kxbarLcdBannerTable 1 } Cc6kxbarLcdBannerEntry ::= SEQUENCE { cc6kxbarLcdBannerIndex Unsigned32, cc6kxbarLcdBannerBanner DisplayString, cc6kxbarLcdBannerMaxSize Unsigned32 } cc6kxbarLcdBannerIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Object which specifies a unique entry in the table." ::= { cc6kxbarLcdBannerEntry 1 } cc6kxbarLcdBannerBanner OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Message that would be displayed on the fabric card LCD. The size of cc6kxbarLcdBannerBanner should be less than or equal to the cc6kxbarLcdBannerMaxSize value." ::= { cc6kxbarLcdBannerEntry 2 } cc6kxbarLcdBannerMaxSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum size of the associated cc6kxbarLcdBannerBanner object." ::= { cc6kxbarLcdBannerEntry 3 } cc6kxbarTruncatedModeOper OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the truncated mode is operationally enabled on the device or not. 'true' - With the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for all the fabric capable modules. 'false'- With the cc6kxbarMinFabricPresent fabric capable modules and the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for fabric capable modules." ::= { cc6kxbarConfiguration 6 } cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode." ::= { cc6kxbarConfiguration 7 } cc6kxbarForceBusMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether some affected modules are forced to be in 'busmode' or not. 'true' - Setting cc6kxbarForceBusMode to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to 'busmode'. Changing the cc6kxbarForceBusMode to 'true' will make all the affected modules reloaded and booted up as non fabric capable modules. 'false'- Setting cc6kxbarForceBusMode to 'false' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to the default value. Changing cc6kxbarForceBusMode to 'false' will make all the affected modules reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode." ::= { cc6kxbarConfiguration 8 } cc6kxbarBusOnlyModeOper OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the bus mode is operationally enabled on the device or not. 'true' - Modules are allowed to run in 'busmode'. 'false' - None of the modules are allowed to run in 'busmode' i.e., All the non-fabric capable modules will be powered off. Absence of fabric module results in all the fabric capable modules being powered off." ::= { cc6kxbarConfiguration 9 } -- Status objects cc6kxbarFabricActiveSlot OBJECT-TYPE SYNTAX ModuleSlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "cc6kxbarFabricActiveSlot indicates the slot number of the active switching fabric module. A value of zero indicates that the active switching fabric module is either powered down or not present in the chassis." ::= { cc6kxbarStatus 1 } cc6kxbarFabricBackupSlot OBJECT-TYPE SYNTAX ModuleSlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "cc6kxbarFabricBackupSlot indicates the slot number of the backup switching fabric module. A value of zero indicates that the backup switching fabric module is either powered down or not present in the chassis." ::= { cc6kxbarStatus 2 } cc6kxbarModuleModeTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarModuleModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "cc6kxbarModuleModeTable indicates the switching mode of each module in the system." ::= { cc6kxbarStatus 3 } cc6kxbarModuleModeEntry OBJECT-TYPE SYNTAX Cc6kxbarModuleModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in cc6kxbarModuleModeTable. The agent creates an entry when a non switching fabric module is inserted in the chassis. The agent destroys an entry when a non switching fabric module is power down or reset or removed from the chassis." INDEX { cc6kxbarModuleModeModule } ::= { cc6kxbarModuleModeTable 1 } Cc6kxbarModuleModeEntry ::= SEQUENCE { cc6kxbarModuleModeModule ModuleSlotNumber, cc6kxbarModuleModeSwitchingMode INTEGER } cc6kxbarModuleModeModule OBJECT-TYPE SYNTAX ModuleSlotNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module slot number." ::= { cc6kxbarModuleModeEntry 1 } cc6kxbarModuleModeSwitchingMode OBJECT-TYPE SYNTAX INTEGER { busmode(1), crossbarmode(2), dcefmode(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "cc6kxbarModuleModeSwitchingMode indicates switching mode of the cc6kxbarModuleModeModule. 'busmode' - Modules in this mode don't use fabric. Backplane is used for both lookup and data forwarding. 'crossbarmode' - Modules in this mode use backplane for forwarding decision and fabric for data forwarding 'dcefmode' - Modules in this mode use fabric for data forwarding and local forwarding is enabled." ::= { cc6kxbarModuleModeEntry 2 } cc6kxbarModuleChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarModuleChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "cc6kxbarModuleChannelTable shows the operational status of fabric channels. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero." ::= { cc6kxbarStatus 4 } cc6kxbarModuleChannelEntry OBJECT-TYPE SYNTAX Cc6kxbarModuleChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in cc6kxbarModuleChannelTable." INDEX { cc6kxbarModuleChannelModule, cc6kxbarModuleChannelChannel } ::= { cc6kxbarModuleChannelTable 1 } Cc6kxbarModuleChannelEntry ::= SEQUENCE { cc6kxbarModuleChannelModule ModuleSlotNumber, cc6kxbarModuleChannelChannel FabricChannelNumber, cc6kxbarModuleChannelModStatus ChannelStatus, cc6kxbarModuleChannelFabStatus ChannelStatus, cc6kxbarModuleChannelSpeed Gauge32 } cc6kxbarModuleChannelModule OBJECT-TYPE SYNTAX ModuleSlotNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module slot number." ::= { cc6kxbarModuleChannelEntry 1 } cc6kxbarModuleChannelChannel OBJECT-TYPE SYNTAX FabricChannelNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fabric channel number of the cc6kxbarModuleChannelModule." ::= { cc6kxbarModuleChannelEntry 2 } cc6kxbarModuleChannelModStatus OBJECT-TYPE SYNTAX ChannelStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the fabric channel at the cc6kxbarModuleChannelModule." ::= { cc6kxbarModuleChannelEntry 3 } cc6kxbarModuleChannelFabStatus OBJECT-TYPE SYNTAX ChannelStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the fabric channel at the cc6kxbarFabricActiveSlot." ::= { cc6kxbarModuleChannelEntry 4 } cc6kxbarModuleChannelSpeed OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The speed in mega bits per second of the cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule." ::= { cc6kxbarModuleChannelEntry 5 } -- Statistics Objects cc6kxbarStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "cc6kxbarStatisticsTable gives the fabric channel counters and utilization information. This table will be instantiated when cc6kxbarFabricActiveSlot has a valid value other than zero." ::= { cc6kxbarStatistics 1 } cc6kxbarStatisticsEntry OBJECT-TYPE SYNTAX Cc6kxbarStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in cc6kxbarStatisticsTable." INDEX { cc6kxbarStatisticsModule, cc6kxbarStatisticsChannel } ::= { cc6kxbarStatisticsTable 1 } Cc6kxbarStatisticsEntry ::= SEQUENCE { cc6kxbarStatisticsModule ModuleSlotNumber, cc6kxbarStatisticsChannel FabricChannelNumber, cc6kxbarStatisticsInErrors Counter32, cc6kxbarStatisticsOutErrors Counter32, cc6kxbarStatisticsOutDropped Counter32, cc6kxbarStatisticsInUtil Percent, cc6kxbarStatisticsOutUtil Percent, cc6kxbarStatisticsPeakInUtil Percent, cc6kxbarStatisticsPeakTmInUtil DateAndTime, cc6kxbarStatisticsPeakOutUtil Percent, cc6kxbarStatisticsPeakTmOutUtil DateAndTime, cc6kxbarStatisticsLbusDrops Counter32 } cc6kxbarStatisticsModule OBJECT-TYPE SYNTAX ModuleSlotNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module slot number." ::= { cc6kxbarStatisticsEntry 1 } cc6kxbarStatisticsChannel OBJECT-TYPE SYNTAX FabricChannelNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fabric channel number associated with the cc6kxbarStatisticsModule." ::= { cc6kxbarStatisticsEntry 2 } cc6kxbarStatisticsInErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of error packets received on cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized." ::= { cc6kxbarStatisticsEntry 3 } cc6kxbarStatisticsOutErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of error packets transmitted on cc6kxbarStatisticsModule through the cc6kxbarStatisticsChannel since this entry was last initialized." ::= { cc6kxbarStatisticsEntry 4 } cc6kxbarStatisticsOutDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of dropped packets transmitted on the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized." ::= { cc6kxbarStatisticsEntry 5 } cc6kxbarStatisticsInUtil OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "Input utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule." ::= { cc6kxbarStatisticsEntry 6 } cc6kxbarStatisticsOutUtil OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "Output utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule." ::= { cc6kxbarStatisticsEntry 7 } cc6kxbarStatisticsPeakInUtil OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the peak value of cc6kxbarStatisticsInUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule." ::= { cc6kxbarStatisticsEntry 8 } cc6kxbarStatisticsPeakTmInUtil OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakInUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakInUtil is '0'." ::= { cc6kxbarStatisticsEntry 9 } cc6kxbarStatisticsPeakOutUtil OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the peak value of cc6kxbarStatisticsOutUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule." ::= { cc6kxbarStatisticsEntry 10 } cc6kxbarStatisticsPeakTmOutUtil OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakOutUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakOutUtil is '0'." ::= { cc6kxbarStatisticsEntry 11 } cc6kxbarStatisticsLbusDrops OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of packets that have been deterministically dropped due to the threshold on the local bus FIFO, errors and exception conditions." ::= { cc6kxbarStatisticsEntry 12 } cc6kxbarErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "cc6kxbarErrorTable provides the fabric channel error information. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero." ::= { cc6kxbarStatistics 2 } cc6kxbarErrorEntry OBJECT-TYPE SYNTAX Cc6kxbarErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in cc6kxbarErrorTable for a specific fabric channel on a specific module." INDEX { cc6kxbarErrorModule, cc6kxbarErrorChannel } ::= { cc6kxbarErrorTable 1 } Cc6kxbarErrorEntry ::= SEQUENCE { cc6kxbarErrorModule ModuleSlotNumber, cc6kxbarErrorChannel FabricChannelNumber, cc6kxbarErrorModuleCrc Gauge32, cc6kxbarErrorModuleHbeat Gauge32, cc6kxbarErrorModuleSync Gauge32, cc6kxbarErrorModuleDDRSync Gauge32, cc6kxbarErrorChannelSync Gauge32, cc6kxbarErrorChannelBuffer Gauge32, cc6kxbarErrorChannelTimeout Gauge32 } cc6kxbarErrorModule OBJECT-TYPE SYNTAX ModuleSlotNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module slot number." ::= { cc6kxbarErrorEntry 1 } cc6kxbarErrorChannel OBJECT-TYPE SYNTAX FabricChannelNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fabric channel number associated with the cc6kxbarErrorModule." ::= { cc6kxbarErrorEntry 2 } cc6kxbarErrorModuleCrc OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of CRC error packets for the cc6kxbarErrorChannel of the cc6kxbarErrorModule." ::= { cc6kxbarErrorEntry 3 } cc6kxbarErrorModuleHbeat OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of heartbeat misses detected for the cc6kxbarErrorChannel of the cc6kxbarErrorModule." ::= { cc6kxbarErrorEntry 4 } cc6kxbarErrorModuleSync OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of times cc6kxbarErrorModule could not sync to the active switching fabric module." ::= { cc6kxbarErrorEntry 5 } cc6kxbarErrorModuleDDRSync OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of DDR(Double Data Rate) channel sync errors for the cc6kxbarErrorChannel of the cc6kxbarErrorModule." ::= { cc6kxbarErrorEntry 6 } cc6kxbarErrorChannelSync OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of sync errors received at cc6kxbarErrorChannel." ::= { cc6kxbarErrorEntry 7 } cc6kxbarErrorChannelBuffer OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of times the memory buffer for cc6kxbarErrorChannel of the cc6kxbarErrorModule is full." ::= { cc6kxbarErrorEntry 8 } cc6kxbarErrorChannelTimeout OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the total number of timeouts for input from the cc6kxbarErrorChannel of the cc6kxbarErrorModule." ::= { cc6kxbarErrorEntry 9 } -- Switching Bus Objects cc6kxbarSwBusSwitchingStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), stalled(2), isolated(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current switching status of the switching bus on the system. normal -- the switching bus is under normal packet switching operation. stalled -- the switching bus has stopped packet switching but is still attached to the system, i.e., the switching bus is stalled. isolated -- the switching bus has stopped packet switching and is detached from the system, i.e., the switching bus is isolated. The object is only instantiated on systems which support switching bus switching detection feature." ::= { cc6kxbarSwBusObjects 1 } cc6kxbarSwBusFailureDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the failure duration of the switching bus since the switching bus has transitioned out of the normal(1) state as monitored by cc6kxbarSwBusSwitchingStatus. If the object value of cc6kxbarSwBusSwitchingStatus is normal(1), then the object value of cc6kxbarSwBusFailureDuration should be zero. The object is only instantiated on systems which support switching bus switching detection feature." ::= { cc6kxbarSwBusObjects 2 } cc6kxbarSwBusNotifEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether or not the notification cc6kxbarSwBusStatusChangeNotif should be generated when there is change in the switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus. The object is only instantiated on systems which support switching bus switching detection feature." ::= { cc6kxbarSwBusObjects 3 } cc6kxbarSwBusUtilization OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the percentage of bandwidth utilization of the switching bus." ::= { cc6kxbarSwBusObjects 4 } cc6kxbarSwBusPeakUtilization OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the peak percentage value of bandwidth utilization of the switching bus since the system started." ::= { cc6kxbarSwBusObjects 5 } cc6kxbarSwBusPeakTimeUtil OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time at which the peak percentage value of bandwidth utilization of the switching bus value occurred." ::= { cc6kxbarSwBusObjects 6 } -- Internal Bus Objects cc6kxbarIntBusNotifEnable OBJECT-TYPE SYNTAX BITS { intBusCRCErrExcd(0), intBusCRCErrRcvrd(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the generation of a specified notification for internal bus is enabled or not. If a bit corresponding to a notification is set to 1, then that notification can be generated. intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif notification. intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif notification." ::= { cc6kxbarIntBusObjects 1 } cc6kxbarIntBusCRCErrTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarIntBusCRCErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing internal bus CRC error information on a list of physical entities (such as modules)." ::= { cc6kxbarIntBusObjects 2 } cc6kxbarIntBusCRCErrEntry OBJECT-TYPE SYNTAX Cc6kxbarIntBusCRCErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing internal bus CRC error information on a physical entity (such as a module)." INDEX { entPhysicalIndex } ::= { cc6kxbarIntBusCRCErrTable 1 } Cc6kxbarIntBusCRCErrEntry ::= SEQUENCE { cc6kxbarIntBusCRCErrExcdStatus TruthValue, cc6kxbarIntBusCRCErrExcdCount Unsigned32 } cc6kxbarIntBusCRCErrExcdStatus OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the internal bus CRC error on a physical entity is currently exceeding the fatal threshold or not." ::= { cc6kxbarIntBusCRCErrEntry 1 } cc6kxbarIntBusCRCErrExcdCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of times the internal bus CRC error on a physical entity has exceeded the fatal threshold." ::= { cc6kxbarIntBusCRCErrEntry 2 } -- Flow Control Objects cc6kxbarFlowCtrlNotifEnable OBJECT-TYPE SYNTAX BITS { busThreshExcd(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the generation of a specified notification for flow control feature is enabled or not. If a bit corresponding to a notification is set to one, then that notification can be generated. busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif notification." ::= { cc6kxbarFlowCtrlObjects 1 } cc6kxbarFlowCtrlBusFIFOThrMode OBJECT-TYPE SYNTAX INTEGER { off(1), on(2), auto(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the mode configuration of the system bus flow control FIFO threshold. off -- the flow control FIFO threshold is set to the original value defined by the system. on -- the flow control FIFO threshold is set to the lower value defined by the system. auto -- the system starts monitoring the system bus flow control FIFO threshold and will change the flow control FIFO threshold from the original value to the lower value when the system detects the first occurrence of the threshold exceeding on a physical entity (such as a module) over the system allowed limit." ::= { cc6kxbarFlowCtrlObjects 2 } cc6kxbarFlowCtrlBusFIFOThrValue OBJECT-TYPE SYNTAX INTEGER { original(1), lower(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current value of the system bus flow control FIFO threshold, whether it is the original value or the lower value." ::= { cc6kxbarFlowCtrlObjects 3 } cc6kxbarFlowCtrlBusFIFOTransTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value of sysUpTime at the time that the system bus flow control FIFO threshold is transitioned to lower value when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This object will take on the value of zero when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'original'." ::= { cc6kxbarFlowCtrlObjects 4 } -- System Capacity Objects cc6kxbarSysCapPfcOperMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), pfc3a(2), pfc3b(3), pfc3bxl(4), pfc3cst1(5), pfc3cxlst1(6), pfc3c(7), pfc3cxl(8), pfc4(9), pfc4xl(10), pfc4xxl(11), pfc4lite(12) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the operating mode of the policy feature card (PFC). unknown -- unknown. pfc3a -- Policy feature card 3A. pfc3b -- Policy feature card 3B. pfc3bxl -- Policy feature card 3B XL. pfc3cst1 -- Policy feature card 3C ST1. pfc3cxlst1 -- Policy feature card 3C XL ST1. pfc3c -- Policy feature card 3C. pfc3cxl -- Policy feature card 3C XL. pfc4 -- Policy feature card 4. pfc4xl -- Policy feature card 4 XL. pfc4xxl -- Policy feature card 4 XXL. pfc4lite -- Policy feature card 4 Lite." ::= { cc6kxbarSystemCapacityObjects 1 } cc6kxbarSysCapSwitchResTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarSysCapSwitchResEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A cc6kxbarSysCapSwitchResTable entry lists the capacity information of the switching resources for ENTITY-MIB entPhysicalTable entries of manageable components with type entPhysicalClass module(9)." ::= { cc6kxbarSystemCapacityObjects 2 } cc6kxbarSysCapSwitchResEntry OBJECT-TYPE SYNTAX Cc6kxbarSysCapSwitchResEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A cc6kxbarSysCapSwitchResEntry entry lists the capacity information of the switching resources for ENTITY-MIB entPhysicalTable entries of manageable components with type entPhysicalClass module(9). Entries are created by the agent at the system power-up or module insertion. Entries are deleted by the agent upon module removal." INDEX { entPhysicalIndex } ::= { cc6kxbarSysCapSwitchResTable 1 } Cc6kxbarSysCapSwitchResEntry ::= SEQUENCE { cc6kxbarSysCapSwitchResSeries INTEGER, cc6kxbarSysCapSwitchResCefMode INTEGER } cc6kxbarSysCapSwitchResSeries OBJECT-TYPE SYNTAX INTEGER { unknown(1), supervisor(2), classic(3), fabric(4), dcef720(5), cef720(6), dcef256(7), cef256(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the module series for traffic forwarding options. unknown -- unknown. supervisor -- supervisor module. classic -- classic module. fabric -- fabric module. dcef720 -- dCEF720 module. cef720 -- CEF720 module. dcef256 -- dCEF256 module. cef256 -- CEF256 module." ::= { cc6kxbarSysCapSwitchResEntry 1 } cc6kxbarSysCapSwitchResCefMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), dcef(2), cef(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Cisco Express Forwarding (CEF) mode of the module. notApplicable -- not applicable for this module. dcef -- distributed CEF. cef -- CEF." ::= { cc6kxbarSysCapSwitchResEntry 2 } -- Fabric Error Recovery Objects cc6kxbarErrRcvryThreshLink OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the threshold on fabric link errors occurring in a channel for the fabric error recovery feature." ::= { cc6kxbarErrorRecoveryObjects 1 } cc6kxbarErrRcvryThreshPersLink OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the threshold on persistent fabric link errors occurring in a channel for the fabric error recovery feature." ::= { cc6kxbarErrorRecoveryObjects 2 } cc6kxbarErrRcvrySwitchoverEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the switchover to the standby fabric module is enabled or not on the detection of excessive fabric link errors occurring in a channel for the fabric error recovery feature." ::= { cc6kxbarErrorRecoveryObjects 3 } cc6kxbarErrRcvryPersLinkResync OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the system will resync the channel or not on the detection of excessive persistent fabric link errors in a channel for the fabric error recovery feature." ::= { cc6kxbarErrorRecoveryObjects 4 } cc6kxbarErrRcvryChResyncCount OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the consecutive number of times of channel resync within the time interval as specified by cc6kxbarErrRcvryChResyncInterval, over which the channel resync is considered as failure for the fabric error recovery feature." ::= { cc6kxbarErrorRecoveryObjects 5 } cc6kxbarErrRcvryChResyncInterval OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the time interval for the consecutive counting of channel resync for the fabric error recovery feature." ::= { cc6kxbarErrorRecoveryObjects 6 } -- Traffic Monitor Objects cc6kxbarTMSwBusUtilEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the traffic monitor feature is enabled on the switching bus or not." ::= { cc6kxbarTrafficMonitorSwBusObjects 1 } cc6kxbarTMSwBusUtilInterval OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the interval at the end of which the switching bus traffic utilization is compared against cc6kxbarTMSwBusUtilThreshold." ::= { cc6kxbarTrafficMonitorSwBusObjects 2 } cc6kxbarTMSwBusUtilThreshold OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the threshold of the switching bus traffic utilization." ::= { cc6kxbarTrafficMonitorSwBusObjects 3 } cc6kxbarTMSwBusUtilLogCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of times the following events are logged for the switching bus: 1. the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). 2. the switching bus traffic utilization has fallen below the configured threshold." ::= { cc6kxbarTrafficMonitorSwBusObjects 4 } cc6kxbarTMSwBusUtilLastLogTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the last logging time of the events as counted in cc6kxbarTMSwBusUtilLogCount. This object will contain 0-1-1,00:00:00.0 when the value of cc6kxbarTMSwBusUtilLogCount is zero." ::= { cc6kxbarTrafficMonitorSwBusObjects 5 } cc6kxbarTMSwBusUtilLogInterval OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logging interval if the switching bus traffic utilization keeps staying above the cc6kxbarTMSwBusUtilThreshold." ::= { cc6kxbarTrafficMonitorSwBusObjects 6 } cc6kxbarTMSwBusUtilUtilization OBJECT-TYPE SYNTAX Percent MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The switching bus traffic utilization included in the notification currently being sent." ::= { cc6kxbarTrafficMonitorSwBusObjects 7 } cc6kxbarTMSwBusUtilNotifEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the generation of c6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is disabled." ::= { cc6kxbarTrafficMonitorSwBusObjects 8 } cc6kxbarTMChUtilTable OBJECT-TYPE SYNTAX SEQUENCE OF Cc6kxbarTMChUtilEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "cc6kxbarTrafficMntrChUtilTable provides the information on the traffic utilization of each fabric channel associated with each module slot for a given traffic direction in the chassis." ::= { cc6kxbarTrafficMonitorChObjects 1 } cc6kxbarTMChUtilEntry OBJECT-TYPE SYNTAX Cc6kxbarTMChUtilEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in cc6kxbarTMChUtilTable. Each traffic direction for each fabric channel associated with each module slot in the chassis will have an entry in this table." INDEX { cc6kxbarTMChUtilModule, cc6kxbarTMChUtilChannel, cc6kxbarTMChUtilDirection } ::= { cc6kxbarTMChUtilTable 1 } Cc6kxbarTMChUtilEntry ::= SEQUENCE { cc6kxbarTMChUtilModule ModuleSlotNumber, cc6kxbarTMChUtilChannel FabricChannelNumber, cc6kxbarTMChUtilDirection INTEGER, cc6kxbarTMChUtilEnable TruthValue, cc6kxbarTMChUtilInterval Unsigned32, cc6kxbarTMChUtilThreshold Percent, cc6kxbarTMChUtilLogCount Counter32, cc6kxbarTMChUtilLastLogTime DateAndTime } cc6kxbarTMChUtilModule OBJECT-TYPE SYNTAX ModuleSlotNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the module slot number in the chassis." ::= { cc6kxbarTMChUtilEntry 1 } cc6kxbarTMChUtilChannel OBJECT-TYPE SYNTAX FabricChannelNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the fabric channel number associated with the corresponding cc6kxbarTMChUtilModule." ::= { cc6kxbarTMChUtilEntry 2 } cc6kxbarTMChUtilDirection OBJECT-TYPE SYNTAX INTEGER { ingress(1), egress(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the direction of traffic to be monitored." ::= { cc6kxbarTMChUtilEntry 3 } cc6kxbarTMChUtilEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the traffic monitor feature is enabled on a fabric channel for a given traffic direction or not." ::= { cc6kxbarTMChUtilEntry 4 } cc6kxbarTMChUtilInterval OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the interval at the end of which the traffic utilization on a fabric channel for a given traffic direction is compared against its corresponding cc6kxbarTMChUtilThreshold." ::= { cc6kxbarTMChUtilEntry 5 } cc6kxbarTMChUtilThreshold OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the threshold of the traffic utilization on a fabric channel for a given traffic direction." ::= { cc6kxbarTMChUtilEntry 6 } cc6kxbarTMChUtilLogCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of times the following events are logged on a fabric channel for a given direction. 1. the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). 2. the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold." ::= { cc6kxbarTMChUtilEntry 7 } cc6kxbarTMChUtilLastLogTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the last logging time of the events as counted in the corresponding cc6kxbarTMChUtilLogCount on a fabric channel for a given traffic direction. This object will contain 0-1-1,00:00:00.0 when the corresponding cc6kxbarTMChUtilLogCount is zero." ::= { cc6kxbarTMChUtilEntry 8 } cc6kxbarTMChUtilLogInterval OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the logging interval if the traffic utilization for a fabric channel on a given traffic direction keeps staying above its corresponding cc6kxbarTMChUtilThreshold." ::= { cc6kxbarTrafficMonitorChObjects 2 } cc6kxbarTMChUtilUtilization OBJECT-TYPE SYNTAX Percent MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The traffic utilization on a fabric channel for a given traffic direction included in the notification currently being sent." ::= { cc6kxbarTrafficMonitorChObjects 3 } cc6kxbarTMChUtilNotifEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies whether the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is disabled." ::= { cc6kxbarTrafficMonitorChObjects 4 } -- Notifications ciscoCat6kXbarMIBNotifs OBJECT IDENTIFIER ::= { ciscoCat6kCrossbarMIB 0 } cc6kxbarSwBusStatusChangeNotif NOTIFICATION-TYPE OBJECTS { cc6kxbarSwBusSwitchingStatus, cc6kxbarSwBusFailureDuration } STATUS current DESCRIPTION "A cc6kxbarSwBusStatusChangeNotif notification is sent by the device when there is change in switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus." ::= { ciscoCat6kXbarMIBNotifs 1 } cc6kxbarIntBusCRCErrExcdNotif NOTIFICATION-TYPE OBJECTS { entPhysicalName, entPhysicalVendorType } STATUS current DESCRIPTION "A cc6kxbarIntBusCRCThreshExcdNotif notification is sent by the system when the system has detected that the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has exceeded the fatal threshold." ::= { ciscoCat6kXbarMIBNotifs 2 } cc6kxbarIntBusCRCErrRcvrdNotif NOTIFICATION-TYPE OBJECTS { entPhysicalName, entPhysicalVendorType } STATUS current DESCRIPTION "A cc6kxbarIntBusCRCErrRcvrdNotif notification is sent by the system when the system has recovered as the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has fallen below the normal threshold." ::= { ciscoCat6kXbarMIBNotifs 3 } cc6kxbarFlowCtrlBusThrExcdNotif NOTIFICATION-TYPE OBJECTS { entPhysicalName, entPhysicalVendorType } STATUS current DESCRIPTION "A cc6kxbarFlowCtrlBusThrExcdNotif notification is sent by the system when the system detects the first occurrence of the system bus flow control FIFO threshold exceeding on a physical entity (such as a module) over the system allowed limit when the object value of cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'." ::= { ciscoCat6kXbarMIBNotifs 4 } cc6kxbarTMSwBusUtilAboveNotif NOTIFICATION-TYPE OBJECTS { cc6kxbarTMSwBusUtilUtilization, cc6kxbarTMSwBusUtilThreshold, cc6kxbarTMSwBusUtilInterval, entPhysicalDescr } STATUS current DESCRIPTION "This notification is sent when the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilAboveNotif is sent." ::= { ciscoCat6kXbarMIBNotifs 5 } cc6kxbarTMSwBusUtilBelowNotif NOTIFICATION-TYPE OBJECTS { cc6kxbarTMSwBusUtilUtilization, cc6kxbarTMSwBusUtilThreshold, cc6kxbarTMSwBusUtilInterval, entPhysicalDescr } STATUS current DESCRIPTION "This notification is sent when the switching bus traffic utilization has fallen below the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilBelowNotif is sent." ::= { ciscoCat6kXbarMIBNotifs 6 } cc6kxbarTMChUtilAboveNotif NOTIFICATION-TYPE OBJECTS { cc6kxbarTMChUtilUtilization, cc6kxbarTMChUtilThreshold, cc6kxbarTMChUtilInterval, entPhysicalDescr } STATUS current DESCRIPTION "This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilAboveNotif is sent." ::= { ciscoCat6kXbarMIBNotifs 7 } cc6kxbarTMChUtilBelowNotif NOTIFICATION-TYPE OBJECTS { cc6kxbarTMChUtilUtilization, cc6kxbarTMChUtilThreshold, cc6kxbarTMChUtilInterval, entPhysicalDescr } STATUS current DESCRIPTION "This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilBelowNotif is sent." ::= { ciscoCat6kXbarMIBNotifs 8 } -- Conformance and Compliance cc6kxbarMIBConformance OBJECT IDENTIFIER ::= { ciscoCat6kCrossbarMIB 3 } cc6kxbarMIBCompliances OBJECT IDENTIFIER ::= { cc6kxbarMIBConformance 1 } cc6kxbarMIBGroups OBJECT IDENTIFIER ::= { cc6kxbarMIBConformance 2 } -- Conformance cc6kxbarMIBCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroup, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroup } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support busonly mode feature." ::= { cc6kxbarMIBCompliances 2 } cc6kxbarMIBComplianceVer1 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." ::= { cc6kxbarMIBCompliances 3 } cc6kxbarMIBComplianceVer2 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." GROUP cc6kxbarTruncatedOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational truncated mode." ::= { cc6kxbarMIBCompliances 4 } cc6kxbarMIBComplianceVer3 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." GROUP cc6kxbarTruncatedOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational truncated mode." GROUP cc6kxbarIntBusNotifControlGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus notifications." GROUP cc6kxbarIntBusCRCErrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error notifications." ::= { cc6kxbarMIBCompliances 5 } cc6kxbarMIBComplianceVer4 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." GROUP cc6kxbarTruncatedOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational truncated mode." GROUP cc6kxbarIntBusNotifControlGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus notifications." GROUP cc6kxbarIntBusCRCErrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error notifications." GROUP cc6kxbarIntBusCRCErrGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error status." ::= { cc6kxbarMIBCompliances 6 } cc6kxbarMIBComplianceVer5 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." GROUP cc6kxbarTruncatedOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational truncated mode." GROUP cc6kxbarIntBusNotifControlGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus notifications." GROUP cc6kxbarIntBusCRCErrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error notifications." GROUP cc6kxbarIntBusCRCErrGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error status." GROUP cc6kxbarDcefOnlyModeAllowedGroup DESCRIPTION "This group is mandatory only for platforms which support dcef only mode feature." GROUP cc6kxbarForceBusModeGroup DESCRIPTION "This group is mandatory only for platforms which support force bus mode feature." GROUP cc6kxbarFlowCtrlNotifCtrlGroup DESCRIPTION "This group is mandatory only for platforms which support the system flow control notification control." GROUP cc6kxbarFlowCtrlBusThreshGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold configuration." GROUP cc6kxbarFlowCtrlBusThrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold exceeding notification." GROUP cc6kxbarBusOnlyModeOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational bus mode." ::= { cc6kxbarMIBCompliances 7 } cc6kxbarMIBComplianceVer6 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." GROUP cc6kxbarTruncatedOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational truncated mode." GROUP cc6kxbarIntBusNotifControlGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus notifications." GROUP cc6kxbarIntBusCRCErrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error notifications." GROUP cc6kxbarIntBusCRCErrGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error status." GROUP cc6kxbarDcefOnlyModeAllowedGroup DESCRIPTION "This group is mandatory only for platforms which support dcef only mode feature." GROUP cc6kxbarForceBusModeGroup DESCRIPTION "This group is mandatory only for platforms which support force bus mode feature." GROUP cc6kxbarFlowCtrlNotifCtrlGroup DESCRIPTION "This group is mandatory only for platforms which support the system flow control notification control." GROUP cc6kxbarFlowCtrlBusThreshGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold configuration." GROUP cc6kxbarFlowCtrlBusThrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold exceeding notification." GROUP cc6kxbarBusOnlyModeOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational bus mode." GROUP cc6kxbarSysCapPfcOperModeGroup DESCRIPTION "This group is mandatory only for platforms which support the system information of PFC operational mode." GROUP cc6kxbarSysCapSwitchResGroup DESCRIPTION "This group is mandatory only for platforms which support the capacity information of switching resources in the system." GROUP cc6kxbarChannelUtilGroup1 DESCRIPTION "This group is mandatory only for those platforms which support peak input and output traffic utilization on the fabric channel." GROUP cc6kxbarSwBusGroup1 DESCRIPTION "This group is mandatory only for platforms which support switching bus utilization." GROUP cc6kxbarErrorGroup DESCRIPTION "This group is mandatory only for those platforms which support error statistics on the fabric channel." GROUP cc6kxbarErrRcvryThresholdGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of thresholds on fabric link errors for the fabric error recovery feature." GROUP cc6kxbarErrRcvrySwitchoverGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of fabric switchover on excessive fabric link errors for the fabric error recovery feature." ::= { cc6kxbarMIBCompliances 8 } cc6kxbarMIBComplianceVer7 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." GROUP cc6kxbarTruncatedOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational truncated mode." GROUP cc6kxbarIntBusNotifControlGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus notifications." GROUP cc6kxbarIntBusCRCErrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error notifications." GROUP cc6kxbarIntBusCRCErrGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error status." GROUP cc6kxbarDcefOnlyModeAllowedGroup DESCRIPTION "This group is mandatory only for platforms which support dcef only mode feature." GROUP cc6kxbarForceBusModeGroup DESCRIPTION "This group is mandatory only for platforms which support force bus mode feature." GROUP cc6kxbarFlowCtrlNotifCtrlGroup DESCRIPTION "This group is mandatory only for platforms which support the system flow control notification control." GROUP cc6kxbarFlowCtrlBusThreshGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold configuration." GROUP cc6kxbarFlowCtrlBusThrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold exceeding notification." GROUP cc6kxbarBusOnlyModeOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational bus mode." GROUP cc6kxbarSysCapPfcOperModeGroup DESCRIPTION "This group is mandatory only for platforms which support the system information of PFC operational mode." GROUP cc6kxbarSysCapSwitchResGroup DESCRIPTION "This group is mandatory only for platforms which support the capacity information of switching resources in the system." GROUP cc6kxbarChannelUtilGroup1 DESCRIPTION "This group is mandatory only for those platforms which support peak input and output traffic utilization on the fabric channel." GROUP cc6kxbarSwBusGroup1 DESCRIPTION "This group is mandatory only for platforms which support switching bus utilization." GROUP cc6kxbarErrorGroup DESCRIPTION "This group is mandatory only for those platforms which support error statistics on the fabric channel." GROUP cc6kxbarErrRcvryThresholdGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of thresholds on fabric link errors for the fabric error recovery feature." GROUP cc6kxbarErrRcvrySwitchoverGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of fabric switchover on excessive fabric link errors for the fabric error recovery feature." GROUP cc6kxbarErrRcvryPersLinkResGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of channel resync on excessive persistent fabric link errors for the fabric error recovery feature." GROUP cc6kxbarErrRcvryChResyncGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of channel resync threshold for the fabric error recovery feature." GROUP cc6kxbarTMSwBusUtilGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration for traffic monitor feature on the switching bus." GROUP cc6kxbarTMSwBusUtilNotifControlGroup DESCRIPTION "This group is mandatory for platforms which provide the notification control for traffic monitor notifications on the switching bus." GROUP cc6kxbarTMSwBusUtilNotifObjectGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on the switching bus." GROUP cc6kxbarTMSwBusUtilNotifGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on the switching bus." GROUP cc6kxbarTMChUtilGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration for traffic monitor feature on fabric channels." GROUP cc6kxbarTMChUtilNotifControlGroup DESCRIPTION "This group is mandatory for platforms which provide the notification control for traffic monitor notifications on fabric channels." GROUP cc6kxbarTMChUtilNotifObjectGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on fabric channels." GROUP cc6kxbarTMChUtilNotifGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on fabric channels." ::= { cc6kxbarMIBCompliances 9 } cc6kxbarMIBComplianceVer8 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for the CISCO-CAT6K-CROSSBAR-MIB." MODULE -- this module MANDATORY-GROUPS { cc6kxbarModuleStatusGroupVer1, cc6kxbarChannelStatusGroup, cc6kxbarChannelStatisticsGroupVer1 } GROUP cc6kxbarFallbackGroup DESCRIPTION "This group is mandatory only for those platforms which support fallback mode feature." GROUP cc6kxbarBusOnlyAllowedGroup DESCRIPTION "This group is mandatory only for those platforms which support bus only mode feature." GROUP cc6kxbarLcdBannerGroup DESCRIPTION "This group is mandatory only for those platforms which support lcd banner feature." GROUP cc6kxbarChannelUtilGroup DESCRIPTION "This group is mandatory only for those platforms which support Input and Output traffic utilization on the fabric channel." GROUP cc6kxbarChannelSpeedGroup DESCRIPTION "This group is mandatory only for those platforms which support fabric channel speed feature." GROUP cc6kxbarSwBusGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection feature." GROUP cc6kxbarSwBusNotifGroup DESCRIPTION "This group is mandatory only for platforms which support switching bus switching detection notification feature." GROUP cc6kxbarTruncatedOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational truncated mode." GROUP cc6kxbarIntBusNotifControlGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus notifications." GROUP cc6kxbarIntBusCRCErrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error notifications." GROUP cc6kxbarIntBusCRCErrGroup DESCRIPTION "This group is mandatory only for platforms which support internal bus CRC error status." GROUP cc6kxbarDcefOnlyModeAllowedGroup DESCRIPTION "This group is mandatory only for platforms which support dcef only mode feature." GROUP cc6kxbarForceBusModeGroup DESCRIPTION "This group is mandatory only for platforms which support force bus mode feature." GROUP cc6kxbarFlowCtrlNotifCtrlGroup DESCRIPTION "This group is mandatory only for platforms which support the system flow control notification control." GROUP cc6kxbarFlowCtrlBusThreshGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold configuration." GROUP cc6kxbarFlowCtrlBusThrNotifGroup DESCRIPTION "This group is mandatory only for platforms which support the system bus flow control FIFO threshold exceeding notification." GROUP cc6kxbarBusOnlyModeOperGroup DESCRIPTION "This group is mandatory only for platforms which support operational bus mode." GROUP cc6kxbarSysCapPfcOperModeGroup DESCRIPTION "This group is mandatory only for platforms which support the system information of PFC operational mode." GROUP cc6kxbarSysCapSwitchResGroup DESCRIPTION "This group is mandatory only for platforms which support the capacity information of switching resources in the system." GROUP cc6kxbarChannelUtilGroup1 DESCRIPTION "This group is mandatory only for those platforms which support peak input and output traffic utilization on the fabric channel." GROUP cc6kxbarSwBusGroup1 DESCRIPTION "This group is mandatory only for platforms which support switching bus utilization." GROUP cc6kxbarErrorGroup DESCRIPTION "This group is mandatory only for those platforms which support error statistics on the fabric channel." GROUP cc6kxbarErrRcvryThresholdGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of thresholds on fabric link errors for the fabric error recovery feature." GROUP cc6kxbarErrRcvrySwitchoverGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of fabric switchover on excessive fabric link errors for the fabric error recovery feature." GROUP cc6kxbarErrRcvryPersLinkResGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of channel resync on excessive persistent fabric link errors for the fabric error recovery feature." GROUP cc6kxbarErrRcvryChResyncGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration of channel resync threshold for the fabric error recovery feature." GROUP cc6kxbarTMSwBusUtilGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration for traffic monitor feature on the switching bus." GROUP cc6kxbarTMSwBusUtilNotifControlGroup DESCRIPTION "This group is mandatory for platforms which provide the notification control for traffic monitor notifications on the switching bus." GROUP cc6kxbarTMSwBusUtilNotifObjectGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on the switching bus." GROUP cc6kxbarTMSwBusUtilNotifGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on the switching bus." GROUP cc6kxbarTMChUtilGroup DESCRIPTION "This group is mandatory for platforms which provide the configuration for traffic monitor feature on fabric channels." GROUP cc6kxbarTMChUtilNotifControlGroup DESCRIPTION "This group is mandatory for platforms which provide the notification control for traffic monitor notifications on fabric channels." GROUP cc6kxbarTMChUtilNotifObjectGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on fabric channels." GROUP cc6kxbarTMChUtilNotifGroup DESCRIPTION "This group is mandatory for platforms which support traffic monitor notifications on fabric channels." GROUP cc6kxbarStatisticsLbusDropGroup DESCRIPTION "This group is mandatory for platforms which support local bus packet drop statistics on fabric channels." ::= { cc6kxbarMIBCompliances 10 } -- Units of Conformance cc6kxbarModuleStatusGroup OBJECT-GROUP OBJECTS { cc6kxbarLcdBannerMaxSize, cc6kxbarLcdBannerBanner, cc6kxbarTruncatedModeAllowed, cc6kxbarMinFabricPresent, cc6kxbarFabricActiveSlot, cc6kxbarFabricBackupSlot, cc6kxbarModuleModeSwitchingMode } STATUS deprecated DESCRIPTION "A collection of objects providing configuration and operation of the crossbar switching fabric module and switching capable module. cc6kxbarModuleStatusGroup object is superseded by cc6kxbarModuleStatusGroupVer1." ::= { cc6kxbarMIBGroups 1 } cc6kxbarChannelStatusGroup OBJECT-GROUP OBJECTS { cc6kxbarModuleChannelModStatus, cc6kxbarModuleChannelFabStatus } STATUS current DESCRIPTION "A collection of objects providing status and configuration of the fabric channel." ::= { cc6kxbarMIBGroups 2 } cc6kxbarChannelStatisticsGroup OBJECT-GROUP OBJECTS { cc6kxbarStatisticsInErrors, cc6kxbarStatisticsOutErrors, cc6kxbarStatisticsOutDropped, cc6kxbarStatisticsInUtil, cc6kxbarStatisticsOutUtil } STATUS deprecated DESCRIPTION "A collection of objects providing statistics for the fabric channel. cc6kxbarChannelStatisticsGroup object is superseded by cc6kxbarChannelStatisticsGroupVer1." ::= { cc6kxbarMIBGroups 3 } cc6kxbarFallbackGroup OBJECT-GROUP OBJECTS { cc6kxbarFallbackMode } STATUS current DESCRIPTION "This object controls system fallback to bus-mode after loss of switching fabric module." ::= { cc6kxbarMIBGroups 4 } cc6kxbarBusOnlyAllowedGroup OBJECT-GROUP OBJECTS { cc6kxbarBusOnlyModeAllowed } STATUS current DESCRIPTION "This object determines the value of cc6kxbarModuleModeSwitchingMode of each module." ::= { cc6kxbarMIBGroups 5 } cc6kxbarModuleStatusGroupVer1 OBJECT-GROUP OBJECTS { cc6kxbarTruncatedModeAllowed, cc6kxbarMinFabricPresent, cc6kxbarFabricActiveSlot, cc6kxbarFabricBackupSlot, cc6kxbarModuleModeSwitchingMode } STATUS current DESCRIPTION "A collection of objects providing configuration and operation of the crossbar switching fabric module and switching capable module." ::= { cc6kxbarMIBGroups 6 } cc6kxbarChannelStatisticsGroupVer1 OBJECT-GROUP OBJECTS { cc6kxbarStatisticsInErrors, cc6kxbarStatisticsOutErrors, cc6kxbarStatisticsOutDropped } STATUS current DESCRIPTION "A collection of objects providing statistics for the fabric channel." ::= { cc6kxbarMIBGroups 7 } cc6kxbarLcdBannerGroup OBJECT-GROUP OBJECTS { cc6kxbarLcdBannerMaxSize, cc6kxbarLcdBannerBanner } STATUS current DESCRIPTION "A collection of objects providing configuration of the lcd Banner of the fabric module." ::= { cc6kxbarMIBGroups 8 } cc6kxbarChannelUtilGroup OBJECT-GROUP OBJECTS { cc6kxbarStatisticsInUtil, cc6kxbarStatisticsOutUtil } STATUS current DESCRIPTION "These object determines Input and Output Utilization of the fabric channel." ::= { cc6kxbarMIBGroups 9 } cc6kxbarChannelSpeedGroup OBJECT-GROUP OBJECTS { cc6kxbarModuleChannelSpeed } STATUS current DESCRIPTION "A collection of objects providing the speed of the fabric channel." ::= { cc6kxbarMIBGroups 10 } cc6kxbarSwBusGroup OBJECT-GROUP OBJECTS { cc6kxbarSwBusSwitchingStatus, cc6kxbarSwBusFailureDuration, cc6kxbarSwBusNotifEnable } STATUS current DESCRIPTION "A collection of objects for the switching bus switching detection feature." ::= { cc6kxbarMIBGroups 11 } cc6kxbarSwBusNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { cc6kxbarSwBusStatusChangeNotif } STATUS current DESCRIPTION "A collection of notifications for the switching bus switching detection feature." ::= { cc6kxbarMIBGroups 12 } cc6kxbarTruncatedOperGroup OBJECT-GROUP OBJECTS { cc6kxbarTruncatedModeOper } STATUS current DESCRIPTION "A collection of objects providing the operational truncated mode." ::= { cc6kxbarMIBGroups 13 } cc6kxbarIntBusNotifControlGroup OBJECT-GROUP OBJECTS { cc6kxbarIntBusNotifEnable } STATUS current DESCRIPTION "A collection of objects to control the notification generation for internal bus." ::= { cc6kxbarMIBGroups 14 } cc6kxbarIntBusCRCErrNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { cc6kxbarIntBusCRCErrExcdNotif, cc6kxbarIntBusCRCErrRcvrdNotif } STATUS current DESCRIPTION "A collection of notifications for the internal bus CRC error." ::= { cc6kxbarMIBGroups 15 } cc6kxbarIntBusCRCErrGroup OBJECT-GROUP OBJECTS { cc6kxbarIntBusCRCErrExcdStatus, cc6kxbarIntBusCRCErrExcdCount } STATUS current DESCRIPTION "A collection of objects to indicate the internal bus CRC error information on a physical entity." ::= { cc6kxbarMIBGroups 16 } cc6kxbarDcefOnlyModeAllowedGroup OBJECT-GROUP OBJECTS { cc6kxbarDcefOnlyModeAllowed } STATUS current DESCRIPTION "A collection of objects providing the configuration and information about the dcef only mode feature." ::= { cc6kxbarMIBGroups 17 } cc6kxbarForceBusModeGroup OBJECT-GROUP OBJECTS { cc6kxbarForceBusMode } STATUS current DESCRIPTION "A collection of objects providing the configuration and information about the force bus mode feature." ::= { cc6kxbarMIBGroups 18 } cc6kxbarFlowCtrlNotifCtrlGroup OBJECT-GROUP OBJECTS { cc6kxbarFlowCtrlNotifEnable } STATUS current DESCRIPTION "A collection of objects to control the notification generation for the system flow control feature." ::= { cc6kxbarMIBGroups 19 } cc6kxbarFlowCtrlBusThreshGroup OBJECT-GROUP OBJECTS { cc6kxbarFlowCtrlBusFIFOThrMode, cc6kxbarFlowCtrlBusFIFOThrValue, cc6kxbarFlowCtrlBusFIFOTransTime } STATUS current DESCRIPTION "A collection of objects providing configuration information about the system bus flow control FIFO threshold." ::= { cc6kxbarMIBGroups 20 } cc6kxbarFlowCtrlBusThrNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { cc6kxbarFlowCtrlBusThrExcdNotif } STATUS current DESCRIPTION "A collection of notifications for the system bus flow control FIFO threshold exceeding." ::= { cc6kxbarMIBGroups 21 } cc6kxbarBusOnlyModeOperGroup OBJECT-GROUP OBJECTS { cc6kxbarBusOnlyModeOper } STATUS current DESCRIPTION "A collection of objects providing the operational bus mode." ::= { cc6kxbarMIBGroups 22 } cc6kxbarSysCapPfcOperModeGroup OBJECT-GROUP OBJECTS { cc6kxbarSysCapPfcOperMode } STATUS current DESCRIPTION "A collection of objects providing the system information of PFC operational mode." ::= { cc6kxbarMIBGroups 23 } cc6kxbarSysCapSwitchResGroup OBJECT-GROUP OBJECTS { cc6kxbarSysCapSwitchResSeries, cc6kxbarSysCapSwitchResCefMode } STATUS current DESCRIPTION "A collection of objects providing the capacity information of switching resources in the system." ::= { cc6kxbarMIBGroups 24 } cc6kxbarChannelUtilGroup1 OBJECT-GROUP OBJECTS { cc6kxbarStatisticsPeakInUtil, cc6kxbarStatisticsPeakTmInUtil, cc6kxbarStatisticsPeakOutUtil, cc6kxbarStatisticsPeakTmOutUtil } STATUS current DESCRIPTION "A collection of objects providing the information about peak input and output utilization of a specific fabric channel on a specific module." ::= { cc6kxbarMIBGroups 25 } cc6kxbarSwBusGroup1 OBJECT-GROUP OBJECTS { cc6kxbarSwBusUtilization, cc6kxbarSwBusPeakUtilization, cc6kxbarSwBusPeakTimeUtil } STATUS current DESCRIPTION "A collection of objects providing the information about switching bus utilization." ::= { cc6kxbarMIBGroups 26 } cc6kxbarErrorGroup OBJECT-GROUP OBJECTS { cc6kxbarErrorModuleCrc, cc6kxbarErrorModuleHbeat, cc6kxbarErrorModuleSync, cc6kxbarErrorModuleDDRSync, cc6kxbarErrorChannelSync, cc6kxbarErrorChannelBuffer, cc6kxbarErrorChannelTimeout } STATUS current DESCRIPTION "A collection of objects providing error statistics for a specific fabric channel on a specific module." ::= { cc6kxbarMIBGroups 27 } cc6kxbarErrRcvryThresholdGroup OBJECT-GROUP OBJECTS { cc6kxbarErrRcvryThreshLink, cc6kxbarErrRcvryThreshPersLink } STATUS current DESCRIPTION "A collection of objects providing the configuration of thresholds on fabric link errors for the fabric error recovery feature." ::= { cc6kxbarMIBGroups 28 } cc6kxbarErrRcvrySwitchoverGroup OBJECT-GROUP OBJECTS { cc6kxbarErrRcvrySwitchoverEnable } STATUS current DESCRIPTION "A collection of objects providing the configuration of fabric switchover on excessive fabric link errors for the fabric error recovery feature." ::= { cc6kxbarMIBGroups 29 } cc6kxbarErrRcvryPersLinkResGroup OBJECT-GROUP OBJECTS { cc6kxbarErrRcvryPersLinkResync } STATUS current DESCRIPTION "A collection of objects providing the configuration of channel resync on excessive persistent fabric link errors for the fabric error recovery feature." ::= { cc6kxbarMIBGroups 30 } cc6kxbarErrRcvryChResyncGroup OBJECT-GROUP OBJECTS { cc6kxbarErrRcvryChResyncCount, cc6kxbarErrRcvryChResyncInterval } STATUS current DESCRIPTION "A collection of objects providing the configuration for channel resync threshold for the fabric error recovery feature." ::= { cc6kxbarMIBGroups 31 } cc6kxbarTMSwBusUtilGroup OBJECT-GROUP OBJECTS { cc6kxbarTMSwBusUtilEnable, cc6kxbarTMSwBusUtilInterval, cc6kxbarTMSwBusUtilThreshold, cc6kxbarTMSwBusUtilLogCount, cc6kxbarTMSwBusUtilLastLogTime, cc6kxbarTMSwBusUtilLogInterval } STATUS current DESCRIPTION "A collection of objects providing configuration information for traffic monitor feature on the switching bus." ::= { cc6kxbarMIBGroups 32 } cc6kxbarTMSwBusUtilNotifControlGroup OBJECT-GROUP OBJECTS { cc6kxbarTMSwBusUtilNotifEnable } STATUS current DESCRIPTION "A collection of objects to control the traffic monitor notification generation on the switching bus." ::= { cc6kxbarMIBGroups 33 } cc6kxbarTMSwBusUtilNotifObjectGroup OBJECT-GROUP OBJECTS { cc6kxbarTMSwBusUtilUtilization } STATUS current DESCRIPTION "A collection of objects included in the traffic monitor notifications on the switching bus." ::= { cc6kxbarMIBGroups 34 } cc6kxbarTMSwBusUtilNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { cc6kxbarTMSwBusUtilAboveNotif, cc6kxbarTMSwBusUtilBelowNotif } STATUS current DESCRIPTION "A collection of traffic monitor notifications on the switching bus." ::= { cc6kxbarMIBGroups 35 } cc6kxbarTMChUtilGroup OBJECT-GROUP OBJECTS { cc6kxbarTMChUtilEnable, cc6kxbarTMChUtilInterval, cc6kxbarTMChUtilThreshold, cc6kxbarTMChUtilLogCount, cc6kxbarTMChUtilLastLogTime, cc6kxbarTMChUtilLogInterval } STATUS current DESCRIPTION "A collection of objects providing the configuration information for traffic monitor feature on fabric channels." ::= { cc6kxbarMIBGroups 36 } cc6kxbarTMChUtilNotifControlGroup OBJECT-GROUP OBJECTS { cc6kxbarTMChUtilNotifEnable } STATUS current DESCRIPTION "A collection of objects to control the traffic monitor notification generation on fabric channels." ::= { cc6kxbarMIBGroups 37 } cc6kxbarTMChUtilNotifObjectGroup OBJECT-GROUP OBJECTS { cc6kxbarTMChUtilUtilization } STATUS current DESCRIPTION "A collection of objects included in the traffic monitor notifications on fabric channels." ::= { cc6kxbarMIBGroups 38 } cc6kxbarTMChUtilNotifGroup NOTIFICATION-GROUP NOTIFICATIONS { cc6kxbarTMChUtilAboveNotif, cc6kxbarTMChUtilBelowNotif } STATUS current DESCRIPTION "A collection of traffic monitor notifications on fabric channels." ::= { cc6kxbarMIBGroups 39 } cc6kxbarStatisticsLbusDropGroup OBJECT-GROUP OBJECTS { cc6kxbarStatisticsLbusDrops } STATUS current DESCRIPTION "A collection of objects providing information for local bus drop packets statistics." ::= { cc6kxbarMIBGroups 40 } END