ALCATEL-IND1-CHASSIS-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, OBJECT-IDENTITY, MODULE-IDENTITY, NOTIFICATION-TYPE, Unsigned32, Counter32 FROM SNMPv2-SMI PhysicalIndex, entPhysicalIndex FROM ENTITY-MIB hardentIND1Physical, chassisTraps, hardentIND1Chassis FROM ALCATEL-IND1-BASE SnmpAdminString FROM SNMP-FRAMEWORK-MIB TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; alcatelIND1ChassisMIB MODULE-IDENTITY LAST-UPDATED "200101301100Z" ORGANIZATION "Alcatel Internetworking, Incorporated" CONTACT-INFO "Please consult with Customer Service to insure the most appropriate version of this document is used with the products in question: Alcatel Internetworking, Incorporated (Division 1, Formerly XYLAN Corporation) 26801 West Agoura Road Agoura Hills, CA 91301-5122 United States Of America Telephone: North America +1 800 995 2696 Latin America +1 877 919 9526 Europe +31 23 556 0100 Asia +65 394 7933 All Other +1 818 878 4507 Electronic Mail: support@ind.alcatel.com World Wide Web: http://www.ind.alcatel.com File Transfer Protocol: ftp://ftp.ind.alcatel.com/pub/products/mibs" DESCRIPTION "This module describes an authoritative enterprise-specific Simple etwork Management Protocol (SNMP) Management Information Base (MIB): For the Birds Of Prey Product Line, this is the Chassis Supervision Chassis MIB for managing physical chassis objects not covered in the IETF Entity MIB (rfc 2737). The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used. Copyright (C) 1995-2002 Alcatel Internetworking, Incorporated ALL RIGHTS RESERVED WORLDWIDE" REVISION "200101301100Z" DESCRIPTION "Addressing discrepancies with Alcatel Standard." ::= { hardentIND1Chassis 1 } alcatelIND1ChassisMIBObjects OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis MIB Subsystem Managed Objects." ::= { alcatelIND1ChassisMIB 1 } alcatelIND1ChassisMIBConformance OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis MIB Subsystem Conformance Information." ::= { alcatelIND1ChassisMIB 2 } alcatelIND1ChassisMIBGroups OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis MIB Subsystem Units Of Conformance." ::= { alcatelIND1ChassisMIBConformance 1 } alcatelIND1ChassisMIBCompliances OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis MIB Subsystem Compliance Statements." ::= { alcatelIND1ChassisMIBConformance 2 } alcatelIND1ChassisPhysMIBObjects OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis Physical MIB Subsystem Managed Objects." ::= { hardentIND1Physical 1 } alcatelIND1ChassisPhysMIBConformance OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis Physical MIB Subsystem Conformance Information." ::= { hardentIND1Physical 2 } alcatelIND1ChassisPhysMIBGroups OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis Physical MIB Subsystem Units Of Conformance." ::= { alcatelIND1ChassisPhysMIBConformance 1 } alcatelIND1ChassisPhysMIBCompliances OBJECT-IDENTITY STATUS current DESCRIPTION "Branch For Chassis Supervision Chassis Physical MIB Subsystem Compliance Statements." ::= { alcatelIND1ChassisPhysMIBConformance 2 } -- CONTROL MODULE TABLE chasControlModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF ChasControlModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row for the primary control module." ::= { alcatelIND1ChassisMIBObjects 1 } chasControlModuleEntry OBJECT-TYPE SYNTAX ChasControlModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the primary control module. This table is an extension of the entity physical table but this class is instanciated only for a the primary control module that has a particular Index." INDEX { entPhysicalIndex } ::= { chasControlModuleTable 1 } ChasControlModuleEntry ::= SEQUENCE { chasControlRunningVersion INTEGER, chasControlActivateTimeout INTEGER, chasControlVersionMngt INTEGER, chasControlDelayedActivateTimer Unsigned32 } chasControlRunningVersion OBJECT-TYPE SYNTAX INTEGER { unknown(1), working(2), certified(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identification of the Running Version (or Running Configuration) for the control module. Note that the Running Version value of (1) unknown, (2) working, or (3) certified is returned." ::= { chasControlModuleEntry 1 } chasControlActivateTimeout OBJECT-TYPE SYNTAX INTEGER (0..900) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is in seconds. It represents how much time before the switch automatically falls back to the certified version. This value is set via the Activate(reload working) cli command. An Activate reboot must be initiated via the primary CMM and that the timeout value can be accessed via user interface to the primary CMM only. After the Activate reboot has been initiated, a timeout will occur (i.e., an Activate Timeout) at the timeout value specified by the user. If a reboot cancel has not been received prior to the timeout expiration, the primary CMM will automatically reboot (i.e., re-reboot) using the certified configuration. This ensures that an automatic backup reboot is available using the certified configuration in the event that the user is unable to interface with primary CMM as a result of the attempted Activate reboot. If the Activate reboot is successful, the user cancels the backup reboot via the normal reboot cancellation process (i.e., a zero value is written for the object chasControlDelayedRebootTimer)." ::= { chasControlModuleEntry 2 } chasControlVersionMngt OBJECT-TYPE SYNTAX INTEGER { notSignificant(1), certifySynchro(2), certifyNoSynchro(3), flashSynchro(4), restore(5), activate(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "For the primary this means: notSignificant - No command applied. certifySynchro - Copy the file from the working to the certified directory and from the primary to the secondary (reboot of the secondary). certifyNoSynchro - Copy the file from the working to the certified directory. flashSynchro - Copy the file from the primary to the secondary (reboot of the secondary). restore - Copy the file from the certified directory to the working directory. activate - reload from the working directory. Activate can be scheduled. " ::= { chasControlModuleEntry 3 } chasControlDelayedActivateTimer OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Timer value in seconds used to initiate a delayed activate of the primary CMM. Writing this object to a non-zero value results in CMM reboot of the working directory following expiration of the specified activate timer delay. Writing this object to zero results in an immediately activate process." ::= { chasControlModuleEntry 4 } -- CONTROL REDUNDANT TABLE chasControlRedundantTable OBJECT-TYPE SYNTAX SEQUENCE OF ChasControlRedundantEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per control module. There is always at least one control module in the system." ::= { alcatelIND1ChassisMIBObjects 2 } chasControlRedundantEntry OBJECT-TYPE SYNTAX ChasControlRedundantEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index." INDEX { entPhysicalIndex } ::= { chasControlRedundantTable 1 } ChasControlRedundantEntry ::= SEQUENCE { chasControlNumberOfTakeover Counter32, chasControlDelayedRebootTimer Unsigned32 } chasControlNumberOfTakeover OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of times the control module has changed from primary to secondary mode as a result of a Takeover. Note that this object can be accessed via user interface to either the primary or secondary CMM. The value returned is the number of times that the interfacing control module (either primary or secondary CMM) has changed from primary to secondary mode. This value does not reflect the total number of CMM Takeovers for the switch. To get the total number of Takeovers for the switch, it is necessary to read this value via user interface to each control module independently." ::= { chasControlRedundantEntry 1 } chasControlDelayedRebootTimer OBJECT-TYPE SYNTAX Unsigned32 (0.. 4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Timer value (in seconds) used to initiate a delayed reboot of the primary or secondary CMM using the certified configuration. Writing this object to a non-zero value results in a CMM reboot following expiration of the specified reset timer delay. Writing this object to zero results in cancellation of a pending CMM delayed reboot." ::= { chasControlRedundantEntry 2 } -- CHASSIS TABLE chasChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF ChasChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per chassis. There is always at least one chassis or many like for stackable product." ::= { alcatelIND1ChassisMIBObjects 3 } chasChassisEntry OBJECT-TYPE SYNTAX ChasChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index." INDEX { entPhysicalIndex } ::= { chasChassisTable 1 } ChasChassisEntry ::= SEQUENCE { chasFreeSlots Unsigned32, chasPowerLeft INTEGER, chasNumberOfResets Counter32, chasHardwareBoardTemp INTEGER, chasHardwareCpuTemp INTEGER, chasTempRange INTEGER, chasTempThreshold INTEGER, chasDangerTempThreshold INTEGER, chasPrimaryPhysicalIndex INTEGER } chasFreeSlots OBJECT-TYPE SYNTAX Unsigned32 (0..18) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of free NI front panel slots." ::= { chasChassisEntry 1 } chasPowerLeft OBJECT-TYPE SYNTAX INTEGER (-100000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "The power still available on the chassis in Watts." ::= { chasChassisEntry 2 } chasNumberOfResets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a count of the number of times this station has been reset since a cold-start." ::= { chasChassisEntry 3 } chasHardwareBoardTemp OBJECT-TYPE SYNTAX INTEGER (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for this chassis. This temperature is what is used for comparing to the threshold and determining whether the value is in range." ::= { chasChassisEntry 4 } chasHardwareCpuTemp OBJECT-TYPE SYNTAX INTEGER (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current output of the SPARC Temperature Sensor (degrees Centigrade) for this chassis." ::= { chasChassisEntry 5 } chasTempRange OBJECT-TYPE SYNTAX INTEGER { unknown(1), notPresent(2), underThreshold(3), overFirstThreshold(4), overDangerThreshold(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Temp Range is the value of the temperature sensor for the chassis. The Temp Range value reflects the temperature of the chassis relative to the Temp Threshold value (i.e., over vs. under the threshold)." ::= { chasChassisEntry 6 } chasTempThreshold OBJECT-TYPE SYNTAX INTEGER (30..80) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the threshold temperature in degrees Celsius for the chassis. Temp Threshold is the chassis temperature point at which, when reached due to an ascending or descending temperature transition, a temperature notification is provided to the user. When this threshold is exceeded, we start sending traps and other operator notification." ::= { chasChassisEntry 7 } chasDangerTempThreshold OBJECT-TYPE SYNTAX INTEGER (30..150) MAX-ACCESS read-only STATUS current DESCRIPTION "This Threshold is a second one which is hardcoded. When the Chassis Exceeds this value it starts shutting down NIs. This value will be set by the factory and not changeable." ::= { chasChassisEntry 8 } chasPrimaryPhysicalIndex OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This value holds the Entity Table Physical Index for the Control Module that is currently primary. This is to allow snmp managers to determine which Control Module is currently primary so it knows what entry in the chasControlModuleTable to access for setting the chasControlVersionMngt values for controling the switch." ::= { chasChassisEntry 9 } -- Extension of the Entity physical table chasEntPhysicalTable OBJECT-TYPE SYNTAX SEQUENCE OF ChasEntPhysicalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per physical entity. It is an extension for the entity physical table (rfc 2737) that is instantiated for every physical entity object. The fields are not always significant for every object." ::= { alcatelIND1ChassisPhysMIBObjects 1 } chasEntPhysicalEntry OBJECT-TYPE SYNTAX ChasEntPhysicalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular physical entity." INDEX { entPhysicalIndex } ::= { chasEntPhysicalTable 1 } ChasEntPhysicalEntry ::= SEQUENCE { chasEntPhysAdminStatus INTEGER, chasEntPhysOperStatus INTEGER, chasEntPhysLedStatus BITS, chasEntPhysPower INTEGER, chasEntPhysModuleType SnmpAdminString, chasEntPhysMfgDate SnmpAdminString, chasEntPhysPartNumber SnmpAdminString } chasEntPhysAdminStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), powerOff(2), powerOn(3), reset(4), takeover(5), resetAll(6), standby(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value: powerOn <=> powered up Control Module possible value: powerOn <=> CM up and running reset <=> CM reset takeover <=> Secondary CM takes over resetAll <=> resets the whole switch NI status possible value: powerOn <=> NI is either powered (up or down) or waiting to be powered whenever more power is available. This admin status has not full meaning without chasEntPhysOperStatus powerOff <=> NI down and unpowered and NI will not be powered until user requests it, a failover happens or a reboot happens reset <=> NI reset FABRIC status possible value: powerOn <=> FABRIC is powered powerOff <=> FABRIC is unpowered standby <=> FABRIC is powered and requested to be redundant (inactive) Daughter board status possible value: powerOn <=> DB up and running reset <=> DB reset (TO BE CONFIRMED) Power supply status possible value: powerOn <=> PS up" ::= { chasEntPhysicalEntry 1 } chasEntPhysOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3), unknown(4), secondary(5), notPresent(6), unpowered(7), master(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible value : notPresent <=> NI not present up <=> NI up and running down <=> NI down and powered unpowered <=> NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master <=> up and acting as master up <=> up and acting as slave secondary <=> secondary mode for redundancy Daughter board status possible value : notPresent <=> DB not present up <=> DB up and running down <=> DB down and powered Power supply status possible value : notPresent <=> PS not present up <=> PS up" ::= { chasEntPhysicalEntry 2 } chasEntPhysLedStatus OBJECT-TYPE SYNTAX BITS { ok1GreenLSBit(0), ok1GreenMSBit(1), ok1AmberLSBit(2), ok1AmberMSBit(3), ok2GreenLSBit(4), ok2GreenMSBit(5), ok2AmberLSBit(6), ok2AmberMSBit(7), primary(8), seconadry(9), temperature(10), statusFan(11), fan1LSBit(12), fan1MSBit(13), fan2LSBit(14), fan2MSBit(15), fan3LSBit(16), fan3MSBit(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of each of the LEDs of this module. Falcon CMM: [11] Fan 1=Green (ok) 0=amber (fail) [10] Temperature 1=Green (ok) 0=amber (fail) [9] Secondary CMM 1=amber 0=OFF [8] Primary CMM 1=amber 0=OFF [7:6] OK2 amber 00=off 01=on 10=blink 11=reserved [5:4] OK2 green 00=off 01=on 10=blink 11=reserved [3:2] OK1 amber 00=off 01=on 10=blink 11=reserved [1:0] OK1 green 00=off 01=on 10=blink 11=reserved Eagle CMM: [17:16] Fan 3 (rear) 00=green 01=amber 10=blink 11=reserved [15:14] Fan 2 (top right) 00=green 01=amber 10=blink 11=reserved [13:12] Fan 1 (top left) 00=green 01=amber 10=blink 11=reserved [11] Status 1=Green (ok) 0=amber (fail) [10] Temperature 1=Green (ok) 0=amber (fail) [9] Secondary CMM 1=amber 0=OFF [8] Primary CMM 1=amber 0=OFF [7:6] OK2 amber 00=off 01=on 10=blink 11=reserved [5:4] OK2 green 00=off 01=on 10=blink 11=reserved [3:2] OK1 amber 00=off 01=on 10=blink 11=reserved [1:0] OK1 green 00=off 01=on 10=blink 11=reserved NI: [7:6] OK2 amber 00=off 01=on 10=blink 11=reserved [5:4] OK2 green 00=off 01=on 10=blink 11=reserved [3:2] OK1 amber 00=off 01=on 10=blink 11=reserved [1:0] OK1 green 00=off 01=on 10=blink 11=reserved FABRIC (Eagle Only): [7:6] OK2 Yellow LED 01=on 00=off [5:4] OK2 Green LED 01=on 00=off [3:2] OK1 Yellow LED 01=on 00=off [1:0] OK1 Green LED 01=on 00=off NOTE: Due to European regulation, the LEDs will NEVER be illuminated RED! They in fact will be either green OR amber." ::= { chasEntPhysicalEntry 3 } chasEntPhysPower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is only applicable to the NI, PS and Control Modules. It corresponds to a a static value for the power consumption of an NI module or Control Module. This value is in Watts." ::= { chasEntPhysicalEntry 4 } chasEntPhysModuleType OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the unique Module Type or ID from the entities eeprom. This value is guarrantteed to be unique to each type of Module. This value is only intended for Alcatel internal use." ::= { chasEntPhysicalEntry 5 } chasEntPhysMfgDate OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..11)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the manufacturing date of the entity. Its format is mmm dd yyyy : NOV 27 2001." ::= { chasEntPhysicalEntry 6 } chasEntPhysPartNumber OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the Alcatel Part Number for the entity. This value is used to identify what is needed when placing orders with Alcatel." ::= { chasEntPhysicalEntry 7 } -- --Chassis traps mib : chassisTraps -- --chassisTraps OBJECT IDENTIFIER ::= { notificationIND1Traps 4 } --Chassis traps definition chassisTrapsDesc OBJECT IDENTIFIER ::= { chassisTraps 1 } chassisTrapsObj OBJECT IDENTIFIER ::= { chassisTraps 2 } -- --textual conventions -- ChassisTrapsStrLevel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "enumerated value which provide the urgency level of the STR." SYNTAX INTEGER { strNotFatal (1), --recorverable strApplicationFatal (2), --not recorverable for the application strFatal (3) --not recorverable for the board } ChassisTrapsStrAppID ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Application Identification number" SYNTAX INTEGER (0..255) ChassisTrapsStrSnapID ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Subapplication Identification number. we can have multiple snapIDs per Subapplication (task) but only one is to be used to send STRs." SYNTAX INTEGER (0..255) ChassisTrapsStrfileName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Name of the source file where the fault was detected. This is given by the C ANSI macro __FILE__. The path shouldn't appear." SYNTAX SnmpAdminString(SIZE(0..19)) ChassisTrapsStrfileLineNb ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Line number in the source file where the fault was detected. This is given by the C ANSI macro __LINE__." SYNTAX INTEGER (1..65535) ChassisTrapsStrErrorNb ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Fault identifier. The error number identifies the kind the detected fault and allows a mapping of the data contained in chassisTrapsdataInfo." SYNTAX INTEGER (0..65535) ChassisTrapsStrcomments ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "comment text explaning the fault." SYNTAX SnmpAdminString(SIZE(0..63)) ChassisTrapsStrdataInfo ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Additional data provided to help to find out the origine of the fault. The contain and the significant portion are varying in accordance with chassisTrapsStrErrorNb. The lenght of this field is expressed in bytes." SYNTAX OCTET STRING (SIZE (0..63)) ChassisTrapsObjectType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An enumerated value which provides the object type involved in the alert trap." SYNTAX INTEGER { chassis (1), ni (2), powerSuply (3), fan (4), cmm (5), fabric (6), gbic (7) } ChassisTrapsObjectNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A number defining the order of the object in the set. EX: The number of the considered fan or power supply. This intend to clarify as much as possible the location of the failure or alert. An instance of the appearance of the trap could be: failure on a module. Power supply 3. " SYNTAX INTEGER (0..255) ChassisTrapsAlertNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "this number identify the alert among all the possible chassis alert causes." SYNTAX INTEGER { runningWorking (1), -- The working version is used runningCertified (2), -- The certified version is used certifyStarted (3), -- CERTIFY process started certifyFlashSyncStarted (4), -- CERTIFY w/FLASH SYNCHRO process started certifyCompleted (5), -- CERTIFY process completed successfully certifyFailed (6), -- CERTIFY process failed synchroStarted (7), -- Flash Synchronization process started synchroCompleted (8), -- Flash Synchronization completed successfully synchroFailed (9), -- Flash Synchronization failed restoreStarted (10), -- RESTORE process started restoreCompleted (11), -- RESTORE process completed successfully restoreFailed (12), -- RESTORE process failed takeoverStarted (13), -- CMM take-over being processed takeoverDeferred (14), -- CMM take-over deferred takeoverCompleted (15), -- CMM take-over completed macAllocFailed (16), -- CMS MAC allocation failed macRangeFailed (17), -- CMS MAC range addition failed fanFailed (18), -- One or more of the fans is inoperable fanOk (19), -- Fan is operable fansOk (20), -- All fans are operable tempOverThreshold (21), -- CMM temperature over the threshold tempUnderThreshold (22), -- CMM temperature under the threshold tempOverDangerThreshold (23), -- CMM temperature over danger threshold powerMissing (24), -- Not enough power available psNotOperational (25), -- Power Supply is not operational psOperational (26), -- Power supply is operational psAllOperational (27), -- All power supplies are operational redundancyNotSupported (28), -- Hello protocol disabled, Redundancy not supported redundancyDisabledCertifyNeeded (29), -- Hello protocol disabled, Certify needed cmmStartingAsPrimary (30), -- CMM started as primary cmmStartingAsSecondary (31), -- CMM started as secondary cmmStartupCompleted (32), -- end of CMM start up cmmAPlugged (33), -- cmm a plugged cmmBPlugged (34), -- cmm b plugged cmmAUnPlugged (35), -- cmm a unplugged cmmBUnPlugged (36), -- cmm b unplugged lowNvramBattery (37), -- NV RAM battery is low notEnoughFabricsOperational (38), -- Not enough Fabric boards operational simplexNoSynchro (39), -- Only simplex CMM no flash synchro done secAutoActivate (40), -- secondary CMM autoactivating secAutoCertifyStarted (41), -- secondary CMM autocertifying secAutoCertifyCompleted (42), -- secondary CMM autocertify end secInactiveReset (43), -- cmm b unplugged activateScheduled (44), -- ACTIVATE process scheduled activateStarted (45) -- secondary CMM reset because of inactivity } ChassisTrapsAlertDescr ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "description of the alert maching ChassisTrapsAlertNumber" SYNTAX SnmpAdminString(SIZE(0..127)) -- --object i.e. trap description -- chassisTrapsStr NOTIFICATION-TYPE OBJECTS { chassisTrapsStrLevel , chassisTrapsStrAppID , chassisTrapsStrSnapID , chassisTrapsStrfileName , chassisTrapsStrfileLineNb , chassisTrapsStrErrorNb , chassisTrapsStrcomments , chassisTrapsStrdataInfo } STATUS current DESCRIPTION "A Software Trouble report is sent by whatever application encountering a problem during its execution and would want to aware the user of for maintenance purpose. " ::= { chassisTrapsDesc 0 1 } chassisTrapsAlert NOTIFICATION-TYPE OBJECTS { physicalIndex, chassisTrapsObjectType , chassisTrapsObjectNumber , chassisTrapsAlertNumber , chassisTrapsAlertDescr } STATUS current DESCRIPTION "generic trap notifying something changed in the chassis whatever it's a failure or not " ::= { chassisTrapsDesc 0 2 } chassisTrapsStateChange NOTIFICATION-TYPE OBJECTS { physicalIndex, chassisTrapsObjectType , chassisTrapsObjectNumber , chasEntPhysOperStatus } STATUS current DESCRIPTION "A status change was detected" ::= { chassisTrapsDesc 0 3 } -- -- objects used in the traps. -- chassisTrapsStrLevel OBJECT-TYPE SYNTAX ChassisTrapsStrLevel MAX-ACCESS read-only STATUS current DESCRIPTION "An enumerated value which provides the urgency level of the STR." ::= {chassisTrapsObj 1} chassisTrapsStrAppID OBJECT-TYPE SYNTAX ChassisTrapsStrAppID MAX-ACCESS read-only STATUS current DESCRIPTION "Application Identification number" ::= {chassisTrapsObj 2} chassisTrapsStrSnapID OBJECT-TYPE SYNTAX ChassisTrapsStrSnapID MAX-ACCESS read-only STATUS current DESCRIPTION "Subapplication Identification number. we can have multiple snapIDs per Subapplication (task) but only one is to be used to send STRs." ::= {chassisTrapsObj 3} chassisTrapsStrfileName OBJECT-TYPE SYNTAX ChassisTrapsStrfileName MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the source file where the fault was detected. This is given by the C ANSI macro __FILE__. The path shouldn't appear." ::= {chassisTrapsObj 4} chassisTrapsStrfileLineNb OBJECT-TYPE SYNTAX ChassisTrapsStrfileLineNb MAX-ACCESS read-only STATUS current DESCRIPTION "Line number in the source file where the fault was detected. This is given by the C ANSI macro __LINE__." ::= {chassisTrapsObj 5} chassisTrapsStrErrorNb OBJECT-TYPE SYNTAX ChassisTrapsStrErrorNb MAX-ACCESS read-only STATUS current DESCRIPTION "Fault identificator. The error number identify the kind the detected fault and allow a mapping of the data contained in chassisTrapsdataInfo." ::= {chassisTrapsObj 6} chassisTrapsStrcomments OBJECT-TYPE SYNTAX ChassisTrapsStrcomments MAX-ACCESS read-only STATUS current DESCRIPTION "comment text explaning the fault." ::= {chassisTrapsObj 7} chassisTrapsStrdataInfo OBJECT-TYPE SYNTAX ChassisTrapsStrdataInfo MAX-ACCESS read-only STATUS current DESCRIPTION "Additional data provided to help to find out the origine of the fault. The contain and the significant portion are varying in accordance with chassisTrapsStrErrorNb. The lenght of this field is expressed in bytes." ::= {chassisTrapsObj 8} chassisTrapsObjectType OBJECT-TYPE SYNTAX ChassisTrapsObjectType MAX-ACCESS read-only STATUS current DESCRIPTION "enumerated value which provide the object type involved in the alert trap." ::= {chassisTrapsObj 9} chassisTrapsObjectNumber OBJECT-TYPE SYNTAX ChassisTrapsObjectNumber MAX-ACCESS read-only STATUS current DESCRIPTION "number defining the order of the object in the set. EX: number of the considered fan or power supply. This intend to clarify as much as possible the location of the failure or alert. A instance of the appearance of the trap could be: failure on a module. Power supply 3. " ::= {chassisTrapsObj 10} chassisTrapsAlertNumber OBJECT-TYPE SYNTAX ChassisTrapsAlertNumber MAX-ACCESS read-only STATUS current DESCRIPTION "this number identify the alert among all the possible chassis alert causes." ::= {chassisTrapsObj 11} chassisTrapsAlertDescr OBJECT-TYPE SYNTAX ChassisTrapsAlertDescr MAX-ACCESS read-only STATUS current DESCRIPTION "description of the alert maching chassisTrapsAlertNumber" ::= {chassisTrapsObj 12} physicalIndex OBJECT-TYPE SYNTAX PhysicalIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The Physical index of the involved object." ::= { chassisTrapsObj 13 } -- END Trap Objects -- xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx -- COMPLIANCE -- xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx alcatelIND1ChassisMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for Chassis Supervision." MODULE MANDATORY-GROUPS { chasControlModuleGroup , chasControlRedundantGroup , chasChassisGroup , chassisNotificationGroup } ::= { alcatelIND1ChassisMIBCompliances 1 } alcatelIND1ChassisPhysMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for Chassis Supervision Physical." MODULE MANDATORY-GROUPS { chasEntPhysicalGroup , chassisPhysNotificationGroup } ::= { alcatelIND1ChassisPhysMIBCompliances 1 } -- xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx -- UNITS OF CONFORMANCE -- xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx chasControlModuleGroup OBJECT-GROUP OBJECTS { chasControlRunningVersion , chasControlActivateTimeout , chasControlVersionMngt , chasControlDelayedActivateTimer } STATUS current DESCRIPTION "Chassis Supervision Control Modules (CMM) Group." ::= { alcatelIND1ChassisMIBGroups 1 } chasControlRedundantGroup OBJECT-GROUP OBJECTS { chasControlNumberOfTakeover , chasControlDelayedRebootTimer } STATUS current DESCRIPTION "Chassis Supervision Redundant Control Modules (CMM) Group." ::= { alcatelIND1ChassisMIBGroups 2 } chasChassisGroup OBJECT-GROUP OBJECTS { chasFreeSlots , chasPowerLeft , chasNumberOfResets , chasHardwareBoardTemp , chasHardwareCpuTemp , chasTempRange , chasTempThreshold , chasDangerTempThreshold , chasPrimaryPhysicalIndex } STATUS current DESCRIPTION "Chassis Supervision Chassis Group." ::= { alcatelIND1ChassisMIBGroups 3 } chassisNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { chassisTrapsStr , chassisTrapsAlert } STATUS current DESCRIPTION "Chassis Supervision Notification Group." ::= { alcatelIND1ChassisMIBGroups 4 } chasEntPhysicalGroup OBJECT-GROUP OBJECTS { chasEntPhysAdminStatus , chasEntPhysOperStatus , chasEntPhysLedStatus , chasEntPhysPower , chasEntPhysModuleType , chasEntPhysMfgDate , chasEntPhysPartNumber } STATUS current DESCRIPTION "Chassis (inclosure) Entity Physical Group." ::= { alcatelIND1ChassisPhysMIBGroups 1 } chassisPhysNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { chassisTrapsStr , chassisTrapsAlert , chassisTrapsStateChange } STATUS current DESCRIPTION "Chassis Supervision Physical Notification Group." ::= { alcatelIND1ChassisPhysMIBGroups 2 } END