-- ============================================================================ -- AT-QOS.MIB, Allied Telesis enterprise MIB: Quality Of Service module -- -- Copied from ATR-QOS.MIB of pre 2.9.1 release -- -- Copyright (c) 2006 by Allied Telesis, Inc. -- All rights reserved. -- -- ============================================================================ AT-QOS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Counter64, Integer32, Gauge32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC modules FROM AT-SMI-MIB ; qos MODULE-IDENTITY LAST-UPDATED "200412011525Z" ORGANIZATION "Allied Telesis, Inc" CONTACT-INFO "http://www.alliedtelesis.com" DESCRIPTION "This MIB file contains definitions of managed objects for the handling QoS on Allied Telesis switches. There are a number of tables designed to be generic to all ATR switches supporting QoS in silicon, and well as tables for specific AT switches or switch familes." REVISION "200412011525Z" DESCRIPTION "Initial Revision" ::= { modules 99 } -- ============================================================================ -- ============================================================================ -- QoS Switch group -- ============================================================================ -- ============================================================================ qosSwitch OBJECT IDENTIFIER ::= { qos 1 } -- ================================================= -- QoS Switch Port table -- ================================================= qosSwitchPortTable OBJECT-TYPE SYNTAX SEQUENCE OF QosSwitchPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Generic port configuration for QoS, indexed by port index." ::= { qosSwitch 1 } qosSwitchPortEntry OBJECT-TYPE SYNTAX QosSwitchPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single switch port entry for QoS." INDEX { qosSwitchPortIndex } ::= { qosSwitchPortTable 1 } QosSwitchPortEntry ::= SEQUENCE { qosSwitchPortIndex Integer32, qosSwitchPortPolicyIndex Integer32 } qosSwitchPortIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port index of the port entry. This index is the same port number used in CLI commands, and the same index as appears in other MIB tables related to switch ports." ::= { qosSwitchPortEntry 1 } qosSwitchPortPolicyIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "Policy index of the policy for this port. Policy index numbers for CLI commands start at 0, while SNMP indexes must start at 1. This means that the policy index in this MIB variable is 1 more than the index for the same policy as entered for CLI commands." ::= { qosSwitchPortEntry 2 } -- ============================================================================ -- Policy table -- ============================================================================ qosSwitchPolicyTable OBJECT-TYPE SYNTAX SEQUENCE OF QosSwitchPolicyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "QoS policy configuration, indexed by policy index." ::= { qosSwitch 2 } qosSwitchPolicyEntry OBJECT-TYPE SYNTAX QosSwitchPolicyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A policy entry containing configuration information for a single policy." INDEX { qosSwitchPolicyIndex } ::= { qosSwitchPolicyTable 1 } QosSwitchPolicyEntry ::= SEQUENCE { qosSwitchPolicyIndex Integer32, qosSwitchPolicyDescription OCTET STRING, qosSwitchPolicyDefaultTCDropBWClass3 INTEGER, qosSwitchPolicyDefaultTCIgnoreBWClass INTEGER, qosSwitchPolicyDefaultTCMarkValue Integer32, qosSwitchPolicyDefaultTCMaxBandwidth Integer32, qosSwitchPolicyDefaultTCMaxBurstSize Integer32, qosSwitchPolicyDefaultTCMinBandwidth Integer32, qosSwitchPolicyDefaultTCMinBurstSize Integer32, qosSwitchPolicyDefaultTCPremarking INTEGER, qosSwitchPolicyDefaultTCRemarking INTEGER } qosSwitchPolicyIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of this policy entry. Policy index numbers for CLI commands start at 0, while SNMP indexes must start at 1. This means that the policy index in this MIB variable is 1 more than the index for the same policy as entered for CLI commands." ::= { qosSwitchPolicyEntry 1 } qosSwitchPolicyDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "An optional description for the policy, as entered via the CLI." ::= { qosSwitchPolicyEntry 2 } qosSwitchPolicyDefaultTCDropBWClass3 OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether traffic that exceeds the bandwidth for the default traffic class be dropped or not. The bandwidth limit is the combined total of the variables qosSwitchPolicyDefaultTCMaxBandwidth and qosSwitchPolicyDefaultTCMaxBurstSize. A value of yes(1) indicates that traffic exceeding the bandwidth limit is dropped immediately. A value of no(0) indicates that the excess traffic is marked as bandwidth class 3 and is therefore eligible for dropping by the RED curve settings." ::= { qosSwitchPolicyEntry 3 } qosSwitchPolicyDefaultTCIgnoreBWClass OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether the traffic metering stage acknowledges any bandwidth class assigned to flows processed by the default traffic class. If set to yes(1), previously assigned bandwidth classes will be ignored will be ignored and the bandwidth class of the traffic will be set according to the meter conformance level of the flow." ::= { qosSwitchPolicyEntry 4 } qosSwitchPolicyDefaultTCMarkValue OBJECT-TYPE SYNTAX Integer32 (0..63 | 256) MAX-ACCESS read-only STATUS current DESCRIPTION "When the qosSwitchPolicyDefaultTCPremarking variable is set to usemarkvalue(1), this variable specifies the index into the DSCP MAP table to use for remarking. A value in the range 0 to 63 indicates the DSCP to use, the value 256 indicates that no DSCP value has been defined for the default traffic class for this policy." ::= { qosSwitchPolicyEntry 5 } qosSwitchPolicyDefaultTCMaxBandwidth OBJECT-TYPE SYNTAX Integer32 (0..16000000 | 2147483647) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum bandwidth available to the default traffic class. Traffic under this bandwidth will be designated as bandwidth class 2. The value 2147483647 indicates that there is no limit on the maximum bandwidth for the default traffic class for this policy." ::= { qosSwitchPolicyEntry 6 } qosSwitchPolicyDefaultTCMaxBurstSize OBJECT-TYPE SYNTAX Integer32 (0..16000000) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum bandwidth above the bandwidth specified by qosSwitchPolicyDefaultTCMaxBandwidth before traffic is marked as bandwidth class 3." ::= { qosSwitchPolicyEntry 7 } qosSwitchPolicyDefaultTCMinBandwidth OBJECT-TYPE SYNTAX Integer32 (0..16000000 | 2147483647) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the minimum bandwidth reserved for the default traffic class. Traffic under this bandwidth will be marked as bandwidth class 1. The value 2147483647 indicates that there is no limit on the minimum bandwidth for the default traffic class for this policy." ::= { qosSwitchPolicyEntry 8 } qosSwitchPolicyDefaultTCMinBurstSize OBJECT-TYPE SYNTAX Integer32 (0..16000000) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum amount of data above the bandwidth specified in the variable qosSwitchPolicyDefaultTCMinBandwidth before traffic is marked as bandwidth class 2." ::= { qosSwitchPolicyEntry 9 } qosSwitchPolicyDefaultTCPremarking OBJECT-TYPE SYNTAX INTEGER { none(0), usemarkvalue(1), usedscp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the QoS action to take on traffic in the default traffic class before metering actions are taken. If none(0) is specified, the traffic is passed to the metering stage. If usemarkvalue(1) is specified, the QoS settings are taken from the variable qosSwitchPolicyDefaultTCMarkValue used as an index into the DCSP MAP table. If usedscp(2) is specified, the DSCP value in the data frames is used as an index into the DSCP MAP table." ::= { qosSwitchPolicyEntry 10 } qosSwitchPolicyDefaultTCRemarking OBJECT-TYPE SYNTAX INTEGER { none(0), usedscpmap(1), bwclass(2), priority(3), bwclass_priority(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the action to take after the metering stage for traffic in the default traffic class. The metering stage assigns a temporary value of bandwidth class to the flow which is used to determine its per-hop behaviour. If this variable is set to bwclass(2) or bwclass_priority(4), the temporary bandwidth class becomes the new bandwidth class for the flow. If priority(3) or bwclass_priority(4) is specified, the currently assigned queue for frames in this traffic class is used in conjunction with the temporary bandwidth class to determine the new value of the VLAN Tag User Priority field. If usedscpmap(1) is specified, the temporary value is used (in conjunction with the DSCP of the frame) as an index into the DSCP MAP table, which then assigns the actual, new values for bandwidth class, DSCP, Egress Queue and VLAN Tag User Priority. A value of none(0) for this variable means that no remarking of the packet is done after the metering stage." ::= { qosSwitchPolicyEntry 11 } -- ============================================================================ -- Traffic Class table -- ============================================================================ qosSwitchTrafficClassTable OBJECT-TYPE SYNTAX SEQUENCE OF QosSwitchTrafficClassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Traffic class configuration, indexed by traffic class index." ::= { qosSwitch 3 } qosSwitchTrafficClassEntry OBJECT-TYPE SYNTAX QosSwitchTrafficClassEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A traffic class entry containing configuration information for a single traffic class." INDEX { qosSwitchTrafficClassIndex } ::= { qosSwitchTrafficClassTable 1 } QosSwitchTrafficClassEntry ::= SEQUENCE { qosSwitchTrafficClassIndex Integer32, qosSwitchTrafficClassPolicyNumber Integer32, qosSwitchTrafficClassDescription OCTET STRING, qosSwitchTrafficClassDropBWClass3 INTEGER, qosSwitchTrafficClassIgnoreBWClass INTEGER, qosSwitchTrafficClassMarkValue Integer32, qosSwitchTrafficClassMaxBandwidth Integer32, qosSwitchTrafficClassMaxBurstSize Integer32, qosSwitchTrafficClassMinBandwidth Integer32, qosSwitchTrafficClassMinBurstSize Integer32, qosSwitchTrafficClassPremarking INTEGER, qosSwitchTrafficClassRemarking INTEGER } qosSwitchTrafficClassIndex OBJECT-TYPE SYNTAX Integer32 (1..1024) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of this traffic class entry. Traffic class index numbers for CLI commands start at 0, while SNMP indexes must start at 1. This means that the traffic class index in this MIB variable is 1 more than the index for the same traffic class as entered for CLI commands." ::= { qosSwitchTrafficClassEntry 1 } qosSwitchTrafficClassPolicyNumber OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-only STATUS current DESCRIPTION "Policy index of the policy to which this traffic class belongs. Policy index numbers for CLI commands start at 0, while SNMP indexes must start at 1. This means that the policy index in this MIB variable is 1 more than the index for the same policy as entered for CLI commands. A value of 0 for this variable means that the traffic class has not been added to a policy yet." ::= { qosSwitchTrafficClassEntry 2 } qosSwitchTrafficClassDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "An optional description for this traffic class." ::= { qosSwitchTrafficClassEntry 3 } qosSwitchTrafficClassDropBWClass3 OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether traffic that exceeds the bandwidth for this traffic class be dropped or not. The bandwidth limit is the combined total of the variables qosSwitchTrafficClassMaxBandwidth and qosSwitchTrafficClassMaxBurstSize A value of yes(1) indicates that traffic exceeding the bandwidth limit is dropped immediately. A value of no(0) indicates that the excess traffic is marked as bandwidth class 3 and is therefore eligible for dropping by the RED curve settings." ::= { qosSwitchTrafficClassEntry 4 } qosSwitchTrafficClassIgnoreBWClass OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether the traffic metering stage acknowledges any bandwidth class assigned to flows processed by this traffic class. If set to yes(1), previously assigned bandwidth classes will be ignored will be ignored and the bandwidth class of the traffic will be set according to the meter conformance level of the flow." ::= { qosSwitchTrafficClassEntry 5 } qosSwitchTrafficClassMarkValue OBJECT-TYPE SYNTAX Integer32 (0..63 | 256) MAX-ACCESS read-only STATUS current DESCRIPTION "When the qosSwitchTrafficClassPremarking variable is set to usemarkvalue(1), this variable specifies the index into the DSCP MAP table to use for remarking. A value in the range 0 to 63 indicates the DSCP to use, the value 256 indicates that no DSCP value has been defined for this traffic class." ::= { qosSwitchTrafficClassEntry 6 } qosSwitchTrafficClassMaxBandwidth OBJECT-TYPE SYNTAX Integer32 (0..16000000 | 2147483647) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum bandwidth available to this traffic class. Traffic under this bandwidth will be designated as bandwidth class 2. The value 2147483647 indicates that there is no limit on the maximum bandwidth for this traffic class." ::= { qosSwitchTrafficClassEntry 7 } qosSwitchTrafficClassMaxBurstSize OBJECT-TYPE SYNTAX Integer32 (0..16000000) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum bandwidth above the bandwidth specified by qosSwitchTrafficClassMaxBandwidth before traffic is marked as bandwidth class 3." ::= { qosSwitchTrafficClassEntry 8 } qosSwitchTrafficClassMinBandwidth OBJECT-TYPE SYNTAX Integer32 (0..16000000 | 2147483647) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the minimum bandwidth reserved for this traffic class. Traffic under this bandwidth will be marked as bandwidth class 1. The value 2147483647 indicates that there is no limit on the minimum bandwidth for this traffic class." ::= { qosSwitchTrafficClassEntry 9 } qosSwitchTrafficClassMinBurstSize OBJECT-TYPE SYNTAX Integer32 (0..16000000) UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum amount of data above the bandwidth specified in the variable qosSwitchTrafficClassMinBandwidth before traffic is marked as bandwidth class 2." ::= { qosSwitchTrafficClassEntry 10 } qosSwitchTrafficClassPremarking OBJECT-TYPE SYNTAX INTEGER { none(0), usemarkvalue(1), usedscp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the QoS action to take on traffic in this traffic class before metering actions are taken. If none(0) is specified, the traffic is passed to the metering stage. If usemarkvalue(1) is specified, the QoS settings are taken from the variable qosSwitchTrafficClassMarkValue used as an index into the DCSP MAP table. If usedscp(2) is specified, the DSCP value in the data frames is used as an index into the DSCP MAP table." ::= { qosSwitchTrafficClassEntry 11 } qosSwitchTrafficClassRemarking OBJECT-TYPE SYNTAX INTEGER { none(0), usedscpmap(1), bwclass(2), priority(3), bwclass_priority(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the action to take after the metering stage for traffic in this traffic class. The metering stage assigns a temporary value of bandwidth class to the flow which is used to determine its per-hop behaviour. If this variable is set to bwclass(2) or bwclass_priority(3), the temporary bandwidth class becomes the new bandwidth class for the flow. If priority(3) or bwclass_priority(4) is specified, the currently assigned queue for frames in this traffic class is used in conjunction with the temporary bandwidth class to determine the new value of the VLAN Tag User Priority field. If usedscpmap(1) is specified, the temporary value is used (in conjunction with the DSCP of the frame) as an index into the DSCP MAP table, which then assigns the actual, new values for bandwidth class, DSCP, Egress Queue and VLAN Tag User Priority. A value of none(0) for this variable means that no remarking of the packet is done after the metering stage." ::= { qosSwitchTrafficClassEntry 12 } -- ============================================================================ -- ============================================================================ -- 8948 specific stuff. The tables in this section are specific to the 8948 -- switch, because they relate directly to the hardware used in this switch. -- Other switches that use the same hardware will also support this MIB table. -- ============================================================================ -- ============================================================================ qosSwitch8948 OBJECT IDENTIFIER ::= { qosSwitch 4 } -- ============================================================================ -- 8948 port table - 8948 specific extensions to the qosSwitchPortTable -- ============================================================================ qosSwitch8948PortTable OBJECT-TYPE SYNTAX SEQUENCE OF QosSwitch8948PortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port configuration, indexed by port index." ::= { qosSwitch8948 1 } qosSwitch8948PortEntry OBJECT-TYPE SYNTAX QosSwitch8948PortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single switch port entry." AUGMENTS { qosSwitchPortEntry } ::= { qosSwitch8948PortTable 1 } QosSwitch8948PortEntry ::= SEQUENCE { qosSwitch8948PortDefaultTCCountersAggregateBytes Counter64, qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes Counter64, qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes Counter64, qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes Counter64, qosSwitch8948PortDefaultTCCountersDroppedBytes Counter64, qosSwitch8948PortQueueLength Gauge32, qosSwitch8948PortQueue0Length Gauge32, qosSwitch8948PortQueue1Length Gauge32, qosSwitch8948PortQueue2Length Gauge32, qosSwitch8948PortQueue3Length Gauge32, qosSwitch8948PortQueue4Length Gauge32, qosSwitch8948PortQueue5Length Gauge32, qosSwitch8948PortQueue6Length Gauge32, qosSwitch8948PortQueue7Length Gauge32 } qosSwitch8948PortDefaultTCCountersAggregateBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes classified by the default traffic class on this port." ::= { qosSwitch8948PortEntry 1 } qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes classified by the default traffic class on this port conforming to bandwidth class 1." ::= { qosSwitch8948PortEntry 2 } qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes classified by the default traffic class on this port conforming to bandwidth class 2." ::= { qosSwitch8948PortEntry 3 } qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes classified by the default traffic class on this port conforming to bandwidth class 3." ::= { qosSwitch8948PortEntry 4 } qosSwitch8948PortDefaultTCCountersDroppedBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes dropped by the default traffic class on this port." ::= { qosSwitch8948PortEntry 5 } qosSwitch8948PortQueueLength OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets currently queued for transmission on this port." ::= { qosSwitch8948PortEntry 6 } qosSwitch8948PortQueue0Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 0. The numbering of queues indicates the priority of handling the traffic in that queue, with the higher queue number getting higher priority. The priority values in packets are mapped to queues via a priority to queue mapping. The default priority to queue mapping is as follows: Priority Queue value number 7 7 6 6 5 5 4 4 3 3 2 1 1 0 0 2 This mapping allows the default priority value of 0 to map to a queue which is not the lowest priority queue, allowing traffic classes to be assigned a lower priority queue than the default." ::= { qosSwitch8948PortEntry 7 } qosSwitch8948PortQueue1Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 1. See the description for qosSwitch8948PortQueue0Length to understand the meaning of queue numbers." ::= { qosSwitch8948PortEntry 8 } qosSwitch8948PortQueue2Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 2. See the description for qosSwitch8948PortQueue0Length to understand the meaning of queue numbers." ::= { qosSwitch8948PortEntry 9 } qosSwitch8948PortQueue3Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 3. See the description for qosSwitch8948PortQueue0Length to understand the meaning of queue numbers." ::= { qosSwitch8948PortEntry 10 } qosSwitch8948PortQueue4Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 4. See the description for qosSwitch8948PortQueue0Length to understand the meaning of queue numbers." ::= { qosSwitch8948PortEntry 11 } qosSwitch8948PortQueue5Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 5. See the description for qosSwitch8948PortQueue0Length to understand the meaning of queue numbers." ::= { qosSwitch8948PortEntry 12 } qosSwitch8948PortQueue6Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 6. See the description for qosSwitch8948PortQueue0Length to understand the meaning of queue numbers." ::= { qosSwitch8948PortEntry 13 } qosSwitch8948PortQueue7Length OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets currently queued for transmission on this port in queue 7. See the description for qosSwitch8948PortQueue0Length to understand the meaning of queue numbers." ::= { qosSwitch8948PortEntry 14 } -- ============================================================================ -- Traffic Class counters table -- ============================================================================ qosSwitch8948TrafficClassCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF QosSwitch8948TrafficClassCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Traffic class counters indexed by port, policy and traffic class." ::= { qosSwitch8948 2 } qosSwitch8948TrafficClassCountersEntry OBJECT-TYPE SYNTAX QosSwitch8948TrafficClassCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A traffic class counters entry containing QOS counters for a particular port, policy and traffic class." INDEX { qosSwitch8948TCCountersPortIndex, qosSwitch8948TCCountersPolicyIndex, qosSwitch8948TCCountersTrafficClassIndex } ::= { qosSwitch8948TrafficClassCountersTable 1 } QosSwitch8948TrafficClassCountersEntry ::= SEQUENCE { qosSwitch8948TCCountersPortIndex Integer32, qosSwitch8948TCCountersPolicyIndex Integer32, qosSwitch8948TCCountersTrafficClassIndex Integer32, qosSwitch8948TCCountersAggregateBytes Counter32, qosSwitch8948TCCountersBwConformanceClass1Bytes Counter32, qosSwitch8948TCCountersBwConformanceClass2Bytes Counter32, qosSwitch8948TCCountersBwConformanceClass3Bytes Counter32, qosSwitch8948TCCountersDroppedBytes Counter32 } qosSwitch8948TCCountersPortIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the port for this entry in the traffic class counter table. This index is the same as the port index in the port table and is the same as the port number of the port in user commands." ::= { qosSwitch8948TrafficClassCountersEntry 1 } qosSwitch8948TCCountersPolicyIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the policy for this entry in the traffic class counter table. Each port can only have one policy assigned at a time. Policy index numbers for CLI commands start at 0, while SNMP indexes must start at 1. This means that the policy index in this MIB variable is 1 more than the index for the same policy as entered for CLI commands." ::= { qosSwitch8948TrafficClassCountersEntry 2 } qosSwitch8948TCCountersTrafficClassIndex OBJECT-TYPE SYNTAX Integer32 (1..1024) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the traffic class for this entry in the traffic class counter table. The index is one of the indices defined for traffic classes for this port and policy. Traffic class indices for CLI commands start at 0, while SNMP indices must start at 1. This means that the traffic class index in this MIB variable is 1 more than the index for the same traffic class as entered for CLI commands." ::= { qosSwitch8948TrafficClassCountersEntry 3 } qosSwitch8948TCCountersAggregateBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes classified by this traffic class for this policy on this port." ::= { qosSwitch8948TrafficClassCountersEntry 4 } qosSwitch8948TCCountersBwConformanceClass1Bytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes classified by this traffic class for this policy on this port conforming to bandwidth class 1." ::= { qosSwitch8948TrafficClassCountersEntry 5 } qosSwitch8948TCCountersBwConformanceClass2Bytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes classified by this traffic class for this policy on this port conforming to bandwidth class 2." ::= { qosSwitch8948TrafficClassCountersEntry 6 } qosSwitch8948TCCountersBwConformanceClass3Bytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes classified by this traffic class for this policy on this port conforming to bandwidth class 3." ::= { qosSwitch8948TrafficClassCountersEntry 7 } qosSwitch8948TCCountersDroppedBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes dropped by this traffic class for this policy on this port." ::= { qosSwitch8948TrafficClassCountersEntry 8 } END