-- ============================================================================ -- AT-ENVMON.MIB, Allied Telesis enterprise MIB: Environment Monitoring -- -- Copied from ATR-ENVMON.MIB of pre 2.9.1 release -- -- Copyright (c) 2006 by Allied Telesis, Inc. -- All rights reserved. -- -- ============================================================================ AT-ENVMON-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, enterprises FROM SNMPv2-SMI TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC ifIndex FROM IF-MIB DisplayStringUnsized FROM AT-SMI-MIB sysinfo FROM AT-SYSINFO-MIB ; envMon MODULE-IDENTITY LAST-UPDATED "200603070000Z" ORGANIZATION "Allied Telesis, Inc" CONTACT-INFO "http://www.alliedtelesis.com" DESCRIPTION "The AT Environment Monitoring MIB for managing and reporting data relating to voltage rails, fan speeds, temperature sensors and power supply units." REVISION "200603070000Z" DESCRIPTION "Initial Revision" ::= { sysinfo 10 } -- Textual Conventions EnvMonPsbSensorType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the type of a Power Supply Bay Device sensor." SYNTAX INTEGER { psbSensorTypeInvalid (0), fanSpeedDiscrete (1), temperatureDiscrete (2), voltageDiscrete (3) } -- This section of the MIB contains new generic environment monitoring -- data. It relates to temperature, fanspeed, voltage and power supply -- bay device monitors. -- ---------------------------------------------------------- -- -- The Environment Monitoring Fan Table -- ---------------------------------------------------------- -- envMonFanTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvMonFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fans installed in the device that have their fan speeds monitored by environment monitoring hardware." ::= { envMon 1 } envMonFanEntry OBJECT-TYPE SYNTAX EnvMonFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The description, current speed, lower threshold speed and current status of a fan." INDEX { envMonFanBoardIndex, envMonFanIndex } ::= { envMonFanTable 1 } EnvMonFanEntry ::= SEQUENCE { envMonFanBoardIndex Unsigned32, envMonFanIndex Unsigned32, envMonFanDescription DisplayStringUnsized, envMonFanCurrentSpeed Unsigned32, envMonFanLowerThreshold Unsigned32, envMonFanAlarm TruthValue } envMonFanBoardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the board hosting this fan in the board table." ::= { envMonFanEntry 1 } envMonFanIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric identifier of this fan within the context of its host board." ::= { envMonFanEntry 2 } envMonFanDescription OBJECT-TYPE SYNTAX DisplayStringUnsized (SIZE (0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "The text description of this fan." ::= { envMonFanEntry 3 } envMonFanCurrentSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed of this fan in revolutions per minute." ::= { envMonFanEntry 4 } envMonFanLowerThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum acceptable speed of the fan (in revolutions per minute)." ::= { envMonFanEntry 5 } envMonFanAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this fan is currently in an alarm condition. A value of TRUE indicates that its current speed is too low, FALSE indicates that the current speed is acceptable." ::= { envMonFanEntry 6 } -- ---------------------------------------------------------- -- -- The Environment Monitoring Voltage Table -- ---------------------------------------------------------- -- envMonVoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvMonVoltageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of voltage rails in the device that are monitored by environment monitoring hardware." ::= { envMon 2 } envMonVoltageEntry OBJECT-TYPE SYNTAX EnvMonVoltageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The description, current value, upper & lower threshold settings and current status of a voltage rail." INDEX { envMonVoltageBoardIndex, envMonVoltageIndex } ::= { envMonVoltageTable 1 } EnvMonVoltageEntry ::= SEQUENCE { envMonVoltageBoardIndex Unsigned32, envMonVoltageIndex Unsigned32, envMonVoltageDescription DisplayStringUnsized, envMonVoltageCurrent INTEGER, envMonVoltageUpperThreshold INTEGER, envMonVoltageLowerThreshold INTEGER, envMonVoltageAlarm TruthValue } envMonVoltageBoardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the board hosting this voltage sensor in the board table." ::= { envMonVoltageEntry 1 } envMonVoltageIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric identifier of this voltage rail within the context of its host board." ::= { envMonVoltageEntry 2 } envMonVoltageDescription OBJECT-TYPE SYNTAX DisplayStringUnsized (SIZE (0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "The text description of this voltage rail." ::= { envMonVoltageEntry 3 } envMonVoltageCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current reading of this voltage rail in millivolts." ::= { envMonVoltageEntry 4 } envMonVoltageUpperThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum acceptable reading of this voltage rail in millivolts." ::= { envMonVoltageEntry 5 } envMonVoltageLowerThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum acceptable reading of this voltage rail in millivolts." ::= { envMonVoltageEntry 6 } envMonVoltageAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this voltage rail is currently in an alarm condition. A value of TRUE indicates that its current reading is outside its threshold range, FALSE indicates that the current reading is acceptable." ::= { envMonVoltageEntry 7 } -- ---------------------------------------------------------- -- -- The Environment Monitoring Temperature Table -- ---------------------------------------------------------- -- envMonTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvMonTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of temperature sensors in the device that are monitored by environment monitoring hardware." ::= { envMon 3 } envMonTemperatureEntry OBJECT-TYPE SYNTAX EnvMonTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The description, current value, upper threshold setting and current status of a temperature sensor." INDEX { envMonTemperatureBoardIndex, envMonTemperatureIndex } ::= { envMonTemperatureTable 1 } EnvMonTemperatureEntry ::= SEQUENCE { envMonTemperatureBoardIndex Unsigned32, envMonTemperatureIndex Unsigned32, envMonTemperatureDescription DisplayStringUnsized, envMonTemperatureCurrent INTEGER, envMonTemperatureUpperThreshold INTEGER, envMonTemperatureAlarm TruthValue } envMonTemperatureBoardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the board hosting this temperature sensor in the board table." ::= { envMonTemperatureEntry 1 } envMonTemperatureIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric identifier of this temperature sensor within the context of its host board." ::= { envMonTemperatureEntry 2 } envMonTemperatureDescription OBJECT-TYPE SYNTAX DisplayStringUnsized (SIZE (0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "The text description of this temperature sensor." ::= { envMonTemperatureEntry 3 } envMonTemperatureCurrent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current reading of this temperature sensor in tenths of a degree Celcius." ::= { envMonTemperatureEntry 4 } envMonTemperatureUpperThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum acceptable reading of this temperature sensor in tenths of a degree Celcius." ::= { envMonTemperatureEntry 5 } envMonTemperatureAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this temperature sensor is currently in an alarm condition. A value of TRUE indicates that its current reading is outside its threshold range, FALSE indicates that the current reading is acceptable." ::= { envMonTemperatureEntry 6 } -- ---------------------------------------------------------- -- -- The Environment Monitoring Power Supply Bay Device Table -- ---------------------------------------------------------- -- envMonPsbObjects OBJECT IDENTIFIER ::= { envMon 4 } envMonPsbTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvMonPsbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table showing power supply bays in the system and info on any devices that are present." ::= { envMonPsbObjects 1 } envMonPsbEntry OBJECT-TYPE SYNTAX EnvMonPsbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The description and current status of a power supply bay device." INDEX { envMonPsbHostBoardIndex, envMonPsbHostSlotIndex } ::= { envMonPsbTable 1 } EnvMonPsbEntry ::= SEQUENCE { envMonPsbHostBoardIndex Unsigned32, envMonPsbHostSlotIndex Unsigned32, envMonPsbHeldBoardIndex Unsigned32, envMonPsbHeldBoardId OBJECT IDENTIFIER, envMonPsbDescription DisplayStringUnsized } envMonPsbHostBoardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the board hosting this PSB in the board table." ::= { envMonPsbEntry 1 } envMonPsbHostSlotIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this PSB slot within the context of its host board. This index is fixed for each slot, on each type of board." ::= { envMonPsbEntry 2 } envMonPsbHeldBoardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of a board installed in this power supply bay. This value corresponds to envMonPsbSensorBoardIndex for each sensor on this board. A value of 0 indicates that a board is is either not present or not supported." ::= { envMonPsbEntry 3 } envMonPsbHeldBoardId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of board installed in this power supply bay. The values of this object are taken from the pprXxx object IDs under the boards sub-tree in the parent MIB. A value of 0 indicates that a board is is either not present or not supported." ::= { envMonPsbEntry 4 } envMonPsbDescription OBJECT-TYPE SYNTAX DisplayStringUnsized (SIZE (0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "The text description of this power supply bay." ::= { envMonPsbEntry 5 } envMonPsbSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvMonPsbSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of environment monitoring sensors on installed power supply bay devices." ::= { envMonPsbObjects 2 } envMonPsbSensorEntry OBJECT-TYPE SYNTAX EnvMonPsbSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The description and current status of a power supply bay device." INDEX { envMonPsbSensorBoardIndex, envMonPsbSensorIndex } ::= { envMonPsbSensorTable 1 } EnvMonPsbSensorEntry ::= SEQUENCE { envMonPsbSensorBoardIndex Unsigned32, envMonPsbSensorIndex Unsigned32, envMonPsbSensorType EnvMonPsbSensorType, envMonPsbSensorDescription DisplayStringUnsized, envMonPsbSensorAlarm TruthValue } envMonPsbSensorBoardIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the board hosting this sensor in the board table." ::= { envMonPsbSensorEntry 1 } envMonPsbSensorIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of this power supply bay environmental sensor, within the context of its host board." ::= { envMonPsbSensorEntry 2 } envMonPsbSensorType OBJECT-TYPE SYNTAX EnvMonPsbSensorType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of environmental variable this sensor detects." ::= { envMonPsbSensorEntry 3 } envMonPsbSensorDescription OBJECT-TYPE SYNTAX DisplayStringUnsized (SIZE (0..30)) MAX-ACCESS read-only STATUS current DESCRIPTION "The text description of this power supply bay environmental sensor." ::= { envMonPsbSensorEntry 4 } envMonPsbSensorAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of whether this environmental sensor is currently in an alarm condition. A value of TRUE indicates that the device is in a failure condition, FALSE indicates that the device is functioning normally." ::= { envMonPsbSensorEntry 5 } -- ---------------------------------------------------------- -- -- The Environment Monitoring SNMP Trap Objects -- ---------------------------------------------------------- -- envMonTraps OBJECT IDENTIFIER ::= { envMon 5 } envMonFanAlarmSetEvent NOTIFICATION-TYPE OBJECTS { envMonFanBoardIndex, envMonFanIndex, envMonFanDescription, envMonFanLowerThreshold, envMonFanCurrentSpeed } STATUS current DESCRIPTION "Triggered when the monitored speed of a fan drops below its lower threshold." ::= { envMonTraps 1 } envMonFanAlarmClearedEvent NOTIFICATION-TYPE OBJECTS { envMonFanBoardIndex, envMonFanIndex, envMonFanDescription, envMonFanLowerThreshold, envMonFanCurrentSpeed } STATUS current DESCRIPTION "Triggered when the monitored speed of a fan returns to an acceptable value, the fan having previously been in an alarm condition." ::= { envMonTraps 2 } envMonVoltAlarmSetEvent NOTIFICATION-TYPE OBJECTS { envMonVoltageBoardIndex, envMonVoltageIndex, envMonVoltageDescription, envMonVoltageUpperThreshold, envMonVoltageLowerThreshold, envMonVoltageCurrent } STATUS current DESCRIPTION "Triggered when the voltage of a monitored voltage rail, goes out of tolerance by either dropping below its lower threshold, or exceeding its upper threshold." ::= { envMonTraps 3 } envMonVoltAlarmClearedEvent NOTIFICATION-TYPE OBJECTS { envMonVoltageBoardIndex, envMonVoltageIndex, envMonVoltageDescription, envMonVoltageUpperThreshold, envMonVoltageLowerThreshold, envMonVoltageCurrent } STATUS current DESCRIPTION "Triggered when the voltage of a monitored voltage rail returns to an acceptable value, having previously been in an alarm condition." ::= { envMonTraps 4 } envMonTempAlarmSetEvent NOTIFICATION-TYPE OBJECTS { envMonTemperatureBoardIndex, envMonTemperatureIndex, envMonTemperatureDescription, envMonTemperatureUpperThreshold, envMonTemperatureCurrent } STATUS current DESCRIPTION "Triggered when a monitored temperature exceeds its upper threshold." ::= { envMonTraps 5 } envMonTempAlarmClearedEvent NOTIFICATION-TYPE OBJECTS { envMonTemperatureBoardIndex, envMonTemperatureIndex, envMonTemperatureDescription, envMonTemperatureUpperThreshold, envMonTemperatureCurrent } STATUS current DESCRIPTION "Triggered when a monitored temperature returns to an acceptable value, having previously been in an alarm condition." ::= { envMonTraps 6 } envMonPsbAlarmSetEvent NOTIFICATION-TYPE OBJECTS { envMonPsbSensorBoardIndex, envMonPsbSensorIndex, envMonPsbSensorType, envMonPsbSensorDescription } STATUS current DESCRIPTION "Triggered when a monitored parameter of a power supply bay device goes out of tolerance." ::= { envMonTraps 7 } envMonPsbAlarmClearedEvent NOTIFICATION-TYPE OBJECTS { envMonPsbSensorBoardIndex, envMonPsbSensorIndex, envMonPsbSensorType, envMonPsbSensorDescription } STATUS current DESCRIPTION "Triggered when a monitored parameter of a power supply bay device returns to an acceptable value, having previously been in an alarm condition." ::= { envMonTraps 8 } END