-- -- -- ACMEPACKET-ENVMON-MIB: Acme Packet Environmental Monitor MIB file -- -- February 2004 -- ---------------------------------------------------------------------- ACMEPACKET-ENVMON-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Gauge32, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF acmepacketMgmt FROM ACMEPACKET-SMI ApHardwareModuleFamily, ApRedundancyState, ApPhyPortType, ApPresence FROM ACMEPACKET-TC; apEnvMonModule MODULE-IDENTITY LAST-UPDATED "200611080000Z" ORGANIZATION "Acme Packet, Inc" CONTACT-INFO " Customer Service Postal: Acme Packet, Inc 71 Third Ave Burlington, MA 01803 USA Phone : 1-781-328-4400 E-mail: support@acmepacket.com" DESCRIPTION "The MIB module to describe the status of the Environmental Monitor on the devices." ::= {acmepacketMgmt 3} ApEnvMonState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the state of a device being monitored. Valid values are: initial (1): the environment is at initial state. normal (2) : the environment is good, such as low temperature. minor (3) : the environment is not good, such as: fan speed is more than minor alarm threshold, but less than major alarm threshold. major (4) : the environment is bad, such as: fan speed is more than major alarm threshold, but less than critical alarm threshold. critical(5): the environment is very bad, such as Fan speed is more than critical threshold. shutdown(6): the environment is the worst, the system should be shutdown immediately. notPresent(7): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(8): the environmental monitor does not function properly, such as 1. I2C fail 2. a temperature sensor generates a abnormal data like 1000 C. unknown(9) : can not get the information due to internal error. " SYNTAX INTEGER { initial(1), normal(2), minor(3), major(4), critical(5), shutdown(6), notPresent(7), notFunctioning(8), unknown(9) } apEnvMonObjects OBJECT IDENTIFIER::= {apEnvMonModule 1} apEnvMonI2CState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "the state of environment monitor located in the chassis." ::= {apEnvMonObjects 1} -- Voltage table apEnvMonVoltageObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 2 } apEnvMonVoltageStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ApEnvMonVoltageStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of voltage status maintained by the environmental monitor." ::= { apEnvMonVoltageObjects 1 } apEnvMonVoltageStatusEntry OBJECT-TYPE SYNTAX ApEnvMonVoltageStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the voltage status table, representing the status of the associated testpoint maintained by the environmental monitor." INDEX { apEnvMonVoltageStatusIndex } ::= { apEnvMonVoltageStatusTable 1 } ApEnvMonVoltageStatusEntry ::= SEQUENCE { apEnvMonVoltageStatusIndex Integer32 (1..2147483647), apEnvMonVoltageStatusType INTEGER, apEnvMonVoltageStatusDescr DisplayString, apEnvMonVoltageStatusValue Integer32, apEnvMonVoltageState ApEnvMonState, apEnvMonVoltageSlotID INTEGER, apEnvMonVoltageSlotType ApHardwareModuleFamily } apEnvMonVoltageStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { apEnvMonVoltageStatusEntry 1 } apEnvMonVoltageStatusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), v2p5 (1), v3p3 (2), v5 (3), cpu (4), v1(5), v1p1(6), v1p15(7), v1p2(8), v1p212(9), v1p25(10), v1p3(11), v1p5(12), v1p8(13), v2p6(14) } MAX-ACCESS read-only STATUS current DESCRIPTION "The entity part type from which the voltage value is from v2p5- 2.5V sensor: L3 cache core voltage; micro-processor and co-processoor I/O voltage; FPGA memories I/O voltage. v3p3 - 3.3V sensor: general TTL supply rail; control logic; micro-processor; micro-processor and co-processor; SDRAM v5 - 5V sensor: Fans; micro-processor core voltage regulator. CPU - CPU voltage micro-processor core voltage." ::= { apEnvMonVoltageStatusEntry 2 } apEnvMonVoltageStatusDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the voltage being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= { apEnvMonVoltageStatusEntry 3 } apEnvMonVoltageStatusValue OBJECT-TYPE SYNTAX Integer32 UNITS "millivolts" MAX-ACCESS read-only STATUS current DESCRIPTION "The current measurement of voltage if avaiable. The value is expressed as the integer in millivolts unit." ::= { apEnvMonVoltageStatusEntry 4 } apEnvMonVoltageState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the testpoint being instrumented." ::= { apEnvMonVoltageStatusEntry 5 } apEnvMonVoltageSlotID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The slot this voltage is found on." ::= { apEnvMonVoltageStatusEntry 6 } apEnvMonVoltageSlotType OBJECT-TYPE SYNTAX ApHardwareModuleFamily MAX-ACCESS read-only STATUS current DESCRIPTION "The type of module found in this slot." ::= { apEnvMonVoltageStatusEntry 7 } -- Temperature Table apEnvMonTemperatureObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 3 } apEnvMonTemperatureStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ApEnvMonTemperatureStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of ambient temperature status maintained by the environmental monitor." ::= { apEnvMonTemperatureObjects 1 } apEnvMonTemperatureStatusEntry OBJECT-TYPE SYNTAX ApEnvMonTemperatureStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ambient temperature status table, representing the status of the associated testpoint maintained by the environmental monitor." INDEX { apEnvMonTemperatureStatusIndex } ::= { apEnvMonTemperatureStatusTable 1 } ApEnvMonTemperatureStatusEntry ::= SEQUENCE { apEnvMonTemperatureStatusIndex Integer32 (1..2147483647), apEnvMonTemperatureStatusType INTEGER, apEnvMonTemperatureStatusDescr DisplayString, apEnvMonTemperatureStatusValue Integer32, apEnvMonTemperatureState ApEnvMonState, apEnvMonTemperatureSlotID INTEGER, apEnvMonTemperatureSlotType ApHardwareModuleFamily } apEnvMonTemperatureStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { apEnvMonTemperatureStatusEntry 1 } apEnvMonTemperatureStatusType OBJECT-TYPE SYNTAX INTEGER { ds1624sMain(1), ds1624sCPU(2), lm84(3), lm75(4), lm75Main(5), lm75Cpu(6), lm75Phy(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The entity part type from which the temperature value is from" ::= { apEnvMonTemperatureStatusEntry 2 } apEnvMonTemperatureStatusDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the temperature being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= { apEnvMonTemperatureStatusEntry 3 } apEnvMonTemperatureStatusValue OBJECT-TYPE SYNTAX Integer32 UNITS "degrees Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "The current measurement of the testpoint being instrumented." ::= { apEnvMonTemperatureStatusEntry 4 } apEnvMonTemperatureState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the testpoint being instrumented." ::= { apEnvMonTemperatureStatusEntry 5 } apEnvMonTemperatureSlotID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The slot this temperature is found on." ::= { apEnvMonTemperatureStatusEntry 6 } apEnvMonTemperatureSlotType OBJECT-TYPE SYNTAX ApHardwareModuleFamily MAX-ACCESS read-only STATUS current DESCRIPTION "The type of module found in this slot." ::= { apEnvMonTemperatureStatusEntry 7 } -- Fan table apEnvMonFanObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 4 } apEnvMonFanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ApEnvMonFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of fan status maintained by the environmental monitor." ::= { apEnvMonFanObjects 1 } apEnvMonFanStatusEntry OBJECT-TYPE SYNTAX ApEnvMonFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the fan status table, representing the status of the associated fan maintained by the environmental monitor." INDEX { apEnvMonFanStatusIndex } ::= { apEnvMonFanStatusTable 1 } ApEnvMonFanStatusEntry ::= SEQUENCE { apEnvMonFanStatusIndex Integer32 (1..2147483647), apEnvMonFanStatusType INTEGER, apEnvMonFanStatusDescr DisplayString, apEnvMonFanStatusValue Gauge32, apEnvMonFanState ApEnvMonState, apEnvMonFanSlotID INTEGER } apEnvMonFanStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique index for the fan being instrumented. This index is for SNMP purposes only." ::= { apEnvMonFanStatusEntry 1 } apEnvMonFanStatusType OBJECT-TYPE SYNTAX INTEGER { left (0), middle (1), right (2), slot (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The entity part type from which the fan value is from. The left and right at the base when one faces the front of the SD. Next-generation products contain replaceable fans contained in chassis slots." ::= { apEnvMonFanStatusEntry 2 } apEnvMonFanStatusDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= { apEnvMonFanStatusEntry 3 } apEnvMonFanStatusValue OBJECT-TYPE SYNTAX Gauge32 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "The current percentage measurement of the fan speed." ::= { apEnvMonFanStatusEntry 4 } apEnvMonFanState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the fan being instrumented." ::= { apEnvMonFanStatusEntry 5 } apEnvMonFanSlotID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The slot this van is found in. zero is returned if this fan is not of apEnvMonFanStatusType slot(3)." ::= { apEnvMonFanStatusEntry 6 } -- Power supply table -- Now no power info can be got, except the power is presented or not apEnvMonPowerSupplyObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 5 } apEnvMonPowerSupplyStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ApEnvMonPowerSupplyStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of power supply status maintained by the environmental monitor card." ::= { apEnvMonPowerSupplyObjects 1 } apEnvMonPowerSupplyStatusEntry OBJECT-TYPE SYNTAX ApEnvMonPowerSupplyStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the power supply status table, representing the status of the associated power supply maintained by the environmental monitor card." INDEX { apEnvMonPowerSupplyStatusIndex } ::= { apEnvMonPowerSupplyStatusTable 1 } ApEnvMonPowerSupplyStatusEntry ::= SEQUENCE { apEnvMonPowerSupplyStatusIndex Integer32 (1..2147483647), apEnvMonPowerSupplyStatusType INTEGER, apEnvMonPowerSupplyStatusDescr DisplayString, apEnvMonPowerSupplyState ApEnvMonState } apEnvMonPowerSupplyStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique index for the power supply being instrumented. This index is for SNMP purposes only." ::= { apEnvMonPowerSupplyStatusEntry 1 } apEnvMonPowerSupplyStatusType OBJECT-TYPE SYNTAX INTEGER { left (0), right (1), slot (3) -- slot enum is 3 to make all slot -- enums align } MAX-ACCESS read-only STATUS current DESCRIPTION "The entity part type from which the power status is from. 0=left:power supply A, 1=right:power supply B. 3=slot: power supply is contained in the slot corresponding to apEnvMonPowerSowerSupplyStatusIndex" ::= { apEnvMonPowerSupplyStatusEntry 2 } apEnvMonPowerSupplyStatusDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= { apEnvMonPowerSupplyStatusEntry 3 } apEnvMonPowerSupplyState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the power supply being instrumented: normal or notPresent" ::= { apEnvMonPowerSupplyStatusEntry 4 } -- Phy table apEnvMonPhyCardObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 6 } apEnvMonPhyCardStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ApEnvMonPhyCardStatusEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "THIS TABLE IS BEING DEPRECATED IN FAVOR OF THE MORE GENERIC apEnvMonCardTable. Please Note: in the generic card table, a phy card is referred to as an 'niu' (network interfacing unit). The table of phy card status maintained by the environmental monitor." ::= { apEnvMonPhyCardObjects 1 } apEnvMonPhyCardStatusEntry OBJECT-TYPE SYNTAX ApEnvMonPhyCardStatusEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry in the phy status table, representing the status of the associated phy maintained by the environmental monitor." INDEX { apEnvMonPhyCardStatusIndex } ::= { apEnvMonPhyCardStatusTable 1 } ApEnvMonPhyCardStatusEntry ::= SEQUENCE { apEnvMonPhyCardStatusIndex Integer32 (1..2147483647), apEnvMonPhyCardStatusType INTEGER, apEnvMonPhyCardStatusDescr DisplayString, apEnvMonPhyCardState ApEnvMonState } apEnvMonPhyCardStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Unique index for the phy being instrumented. This index is for SNMP purposes only." ::= { apEnvMonPhyCardStatusEntry 1 } apEnvMonPhyCardStatusType OBJECT-TYPE SYNTAX INTEGER { left (0), right (1), slot (3) -- slot enum is 3 to make -- all slot enums align } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The entity part type from which the phy card is from. 0=left:card A, 1=right:card B, 3=only card. 3=slot: phyCard is contained in the slot corresponding to apEnvMonPhyCardStatusIndex" ::= { apEnvMonPhyCardStatusEntry 2 } apEnvMonPhyCardStatusDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Textual description of the phy being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= { apEnvMonPhyCardStatusEntry 3 } apEnvMonPhyCardState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current state of the phy being instrumented: normal or notPresent" ::= { apEnvMonPhyCardStatusEntry 4 } apEnvMonCardObjects OBJECT IDENTIFIER ::= { apEnvMonObjects 7 } --------------------------------------- -- Card Table --------------------------------------- apEnvMonCardTable OBJECT-TYPE SYNTAX SEQUENCE OF ApEnvMonCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of Cards in the chassis" ::= { apEnvMonCardObjects 1 } apEnvMonCardEntry OBJECT-TYPE SYNTAX ApEnvMonCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single card in the chassis" INDEX { apEnvMonCardSlot } ::= { apEnvMonCardTable 1 } ApEnvMonCardEntry ::= SEQUENCE { apEnvMonCardSlot INTEGER, apEnvMonCardType ApHardwareModuleFamily, apEnvMonCardDescr DisplayString, apEnvMonCardHealthScore INTEGER, apEnvMonCardState ApEnvMonState, apEnvMonCardRedundancy ApRedundancyState } apEnvMonCardSlot OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number of this card. Please note that the slot number is zero-based, i.e. they are numbered 0-n." ::= { apEnvMonCardEntry 1 } apEnvMonCardType OBJECT-TYPE SYNTAX ApHardwareModuleFamily MAX-ACCESS read-only STATUS current DESCRIPTION "The card type" ::= { apEnvMonCardEntry 2 } apEnvMonCardDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A text description of this card" ::= { apEnvMonCardEntry 3 } apEnvMonCardHealthScore OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The health score of this card" ::= { apEnvMonCardEntry 4 } apEnvMonCardState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS read-only STATUS current DESCRIPTION "the current state of this card" ::= { apEnvMonCardEntry 5 } apEnvMonCardRedundancy OBJECT-TYPE SYNTAX ApRedundancyState MAX-ACCESS read-only STATUS current DESCRIPTION "Redundancy state of the card" ::= { apEnvMonCardEntry 6 } --------------------------------------- -- CPU Core Table --------------------------------------- apEnvMonCpuCoreTable OBJECT-TYPE SYNTAX SEQUENCE OF ApEnvMonCpuCoreEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of cores per CPU in the chassis" ::= { apEnvMonCardObjects 2 } apEnvMonCpuCoreEntry OBJECT-TYPE SYNTAX ApEnvMonCpuCoreEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single CPU core in the chassis" INDEX { apEnvMonCardSlot, apEnvMonCpuCoreIndex } ::= { apEnvMonCpuCoreTable 1 } ApEnvMonCpuCoreEntry ::= SEQUENCE { apEnvMonCpuCoreIndex INTEGER, apEnvMonCpuCoreDescr DisplayString, apEnvMonCpuCoreUsage Gauge32, apEnvMonCpuCoreState INTEGER, apEnvMonCpuCoreRamDescr DisplayString, apEnvMonCpuCoreRamUsage Gauge32 } apEnvMonCpuCoreIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the core index on the CPU" ::= { apEnvMonCpuCoreEntry 1 } apEnvMonCpuCoreDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "the cpu core descriptor" ::= { apEnvMonCpuCoreEntry 2 } apEnvMonCpuCoreUsage OBJECT-TYPE SYNTAX Gauge32 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "The current percentage of use for the CPU core." ::= { apEnvMonCpuCoreEntry 3 } apEnvMonCpuCoreState OBJECT-TYPE SYNTAX INTEGER { unknown(0), present(1), booting(2), registered(3), readywait(4), ready(5), bootTimeout(6), registerTimeout(7), manifestTimeout(8), readyTimeout(9), healthWait(101), healthRcvd(102), becomingActive(201), becomingStandby(202), becomingOOS(203), active(204), standby(205), oos(206), activeTimeout(207), standbyTimeout(208), oosTimeout(209), resetting(401), reset(402), resetTimeout(403), shuttingDown(404), shutOff(405), shutdownTimeout(406) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of this CPU core." ::= { apEnvMonCpuCoreEntry 4 } apEnvMonCpuCoreRamDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The cpu core RAM descriptor" ::= { apEnvMonCpuCoreEntry 5 } apEnvMonCpuCoreRamUsage OBJECT-TYPE SYNTAX Gauge32 UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "The current percentage of use for the CPU core RAM." ::= { apEnvMonCpuCoreEntry 6 } apEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { apEnvMonModule 2 } apEnvMonEnableStatChangeNotif OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates whether the system produces any of the traps generated by this mib. A false value will prevent them from being generated by this system." -- DEFVAL { false } ::= { apEnvMonMIBNotificationEnables 1 } -- Notification MIBs apEnvMonNotificationObjects OBJECT IDENTIFIER ::= { apEnvMonModule 3 } apEnvMonTrapInstance OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The object ID of the item which value is exceeds its monitoring threshold. If the item is within a table, this OID is the instance of this item's index within its table. For exmple, 1. if the state of 2.5v voltage changes, the trap OID is the instance of index OID, which is 1.3.6.1.4.1.9148.3.3.1.2.4.1.1.1 2. if the state of mainboard temperature changes, the trap OID is, 1.3.6.1.4.1.9148.3.3.1.3.4.1.1.1 3. if the state of left fan changes, the trap OID is 1.3.6.1.4.1.9148.3.3.1.4.4.1.1.1 If the item is scalar, the OID is the instance is of this item, For example, If the I2C state changes, the OID is 1.3.6.1.4.1.9148.3.3.1.4.4.1.1.0" ::= { apEnvMonNotificationObjects 1 } apEnvMonTrapPreviousState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The previous state of the object." ::= { apEnvMonNotificationObjects 2 } apEnvMonTrapCurrentState OBJECT-TYPE SYNTAX ApEnvMonState MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The current state of the object which causes the trap to occur." ::= { apEnvMonNotificationObjects 3 } apEnvMonTrapSlotID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The slotID which causes the trap to occur." ::= { apEnvMonNotificationObjects 4 } apEnvMonTrapSlotType OBJECT-TYPE SYNTAX ApHardwareModuleFamily MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The slot type which causes the trap to occur." ::= { apEnvMonNotificationObjects 5 } apEnvMonTrapPortType OBJECT-TYPE SYNTAX ApPhyPortType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The port type which causes the trap to occur." ::= { apEnvMonNotificationObjects 6 } apEnvMonTrapPresence OBJECT-TYPE SYNTAX ApPresence MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The state which causes the trap to occur." ::= { apEnvMonNotificationObjects 7 } apEnvMonTrapPortID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The ID of the port which causes the trap to occur." ::= { apEnvMonNotificationObjects 8 } -- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications -- that are backward compatible with SNMPv1 Traps. apEnvMonMIBNotificationPrefix OBJECT IDENTIFIER ::= { apEnvMonModule 4 } apEnvMonMIBNotifications OBJECT IDENTIFIER ::= { apEnvMonMIBNotificationPrefix 0 } apEnvMonI2CFailNotification NOTIFICATION-TYPE -- no OBJECTS STATUS current DESCRIPTION "A notification of I2C state turns from normal(1) to notFunctioning(7)" ::= { apEnvMonMIBNotifications 1 } apEnvMonStatusChangeNotification NOTIFICATION-TYPE OBJECTS { apEnvMonTrapInstance, apEnvMonTrapPreviousState, apEnvMonTrapCurrentState } STATUS current DESCRIPTION "A apEnvStatusChangeNotification is sent if any entry of above table change in the state of a device being monitored" ::= { apEnvMonMIBNotifications 2 } apEnvMonTempChangeNotification NOTIFICATION-TYPE OBJECTS { apEnvMonTrapSlotID, apEnvMonTrapSlotType, apEnvMonTrapPreviousState, apEnvMonTrapCurrentState } STATUS current DESCRIPTION "A notification is sent if any of the units cross a temperature threshold" ::= { apEnvMonMIBNotifications 3 } apEnvMonVoltageChangeNotification NOTIFICATION-TYPE OBJECTS { apEnvMonTrapSlotID, apEnvMonTrapSlotType, apEnvMonTrapPreviousState, apEnvMonTrapCurrentState } STATUS current DESCRIPTION "A notification is sent if any of the units cross a voltage threshold" ::= { apEnvMonMIBNotifications 4 } apEnvMonPortChangeNotification NOTIFICATION-TYPE OBJECTS { apEnvMonTrapPortType, apEnvMonTrapPresence, apEnvMonTrapSlotID, apEnvMonTrapPortID } STATUS current DESCRIPTION " The trap will be generated if a physical port is inserted/present or removed/not present. " ::= { apEnvMonMIBNotifications 5 } -- conformance information apEnvMonMIBConformance OBJECT IDENTIFIER ::= { apEnvMonModule 5 } apEnvMonMIBCompliances OBJECT IDENTIFIER ::= { apEnvMonMIBConformance 1 } apEnvMonMIBGroups OBJECT IDENTIFIER ::= { apEnvMonMIBConformance 2 } -- compliance statements -- units of conformance apEnvMonGroup OBJECT-GROUP OBJECTS { apEnvMonI2CState, apEnvMonVoltageStatusType, apEnvMonVoltageStatusDescr, apEnvMonVoltageStatusValue, apEnvMonVoltageState, apEnvMonTemperatureStatusType, apEnvMonTemperatureStatusDescr, apEnvMonTemperatureStatusValue, apEnvMonTemperatureState, apEnvMonFanStatusType, apEnvMonFanStatusDescr, apEnvMonFanStatusValue, apEnvMonFanState, apEnvMonPowerSupplyStatusType, apEnvMonPowerSupplyStatusDescr, apEnvMonPowerSupplyState, apEnvMonPhyCardStatusType, apEnvMonPhyCardStatusDescr, apEnvMonPhyCardState, apEnvMonEnableStatChangeNotif } STATUS current DESCRIPTION "A collection of objects providing environmental monitoring capability to an Acme Packet chassis." ::= { apEnvMonMIBGroups 1 } apEnvMonNotifyGroup NOTIFICATION-GROUP NOTIFICATIONS { apEnvMonStatusChangeNotification, apEnvMonI2CFailNotification } STATUS current DESCRIPTION "A collection of notifications providing the status change for environmental monitoring." ::= { apEnvMonMIBGroups 3 } apEnvMonExtGroup OBJECT-GROUP OBJECTS { apEnvMonVoltageSlotID, apEnvMonVoltageSlotType, apEnvMonTemperatureSlotID, apEnvMonTemperatureSlotType, apEnvMonFanSlotID } STATUS current DESCRIPTION "Additional objects providing environmental monitoring capability to an Acme Packet chassis." ::= { apEnvMonMIBGroups 4 } apEnvMonCardGroup OBJECT-GROUP OBJECTS { apEnvMonCardSlot, apEnvMonCardType, apEnvMonCardDescr, apEnvMonCardHealthScore, apEnvMonCardState, apEnvMonCardRedundancy, apEnvMonCpuCoreIndex, apEnvMonCpuCoreDescr, apEnvMonCpuCoreUsage, apEnvMonCpuCoreState, apEnvMonCpuCoreRamDescr, apEnvMonCpuCoreRamUsage } STATUS current DESCRIPTION "A collection of objects providing environmental monitoring capability to card-based Acme Packet products." ::= { apEnvMonMIBGroups 5 } apEnvMonExtNotifyGroup NOTIFICATION-GROUP NOTIFICATIONS { apEnvMonTempChangeNotification, apEnvMonVoltageChangeNotification } STATUS current DESCRIPTION "Additional collection of notifications providing the status change for environmental monitoring." ::= { apEnvMonMIBGroups 6 } apEnvMonPortNotifyGroup NOTIFICATION-GROUP NOTIFICATIONS { apEnvMonPortChangeNotification } STATUS current DESCRIPTION "Notifications to indicate physical port changes." ::= { apEnvMonMIBGroups 7 } END