-- 3Com Switching Systems FDDI Management Information Base -- Version 1.0.0 -- February 13, 1998 -- 3Com Corporation -- 80 Central Street -- Boxborough, MA 01719 -- (508) 264-1400 ---------------------------------------------------------------------------------------- -- 10/07/98 - tmeiczin moved to new directory/formatted mib -- 08/15/98 - tmeiczin Fixed syntax to compiled with SMICng -- 02/13/98 - iwolf Originally created -- ---------------------------------------------------------------------------------------- A3COM-SWITCHING-SYSTEMS-FDDI-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 FddiTimeNano, FddiSMTStationIdType, fddimibSMTStationId, fddimibSMTCFState, fddimibSMTPeerWrapFlag, fddimibMACDaFlag, fddimibMACUnaDaFlag, fddimibMACFrameErrorFlag, fddimibMACFrameCts, fddimibMACErrorCts, fddimibMACLostCts, fddimibMACSMTAddress, fddimibMACNotCopiedCts, fddimibMACCopiedCts, fddimibMACNotCopiedFlag, fddimibMACOldUpstreamNbr, fddimibMACFrameErrorRatio, fddimibMACUpstreamNbr, fddimibMACNotCopiedRatio, fddimibMACDownstreamNbr, fddimibMACOldDownstreamNbr, fddimibMACCurrentPath, fddimibMACAvailablePaths, fddimibMACRequestedPaths, fddimibPORTLerCutoff, fddimibPORTLerAlarm, fddimibPORTLerEstimate, fddimibPORTLemRejectCts, fddimibPORTLemCts, fddimibPORTLerFlag, fddimibPORTMyType, fddimibPORTConnectState, fddimibPORTNeighborType, fddimibPORTPCWithhold, fddimibPORTAvailablePaths, fddimibPORTCurrentPath, fddimibPORTRequestedPaths FROM FDDI-SMT73-MIB; -- Object identifiers a3Com OBJECT IDENTIFIER ::= { enterprises 43 } switchingSystemsMibs OBJECT IDENTIFIER ::= { a3Com 29 } a3ComSwitchingSystemsFddiMib OBJECT IDENTIFIER ::= { switchingSystemsMibs 10 } -- groups a3ComFddiSMT OBJECT IDENTIFIER ::= { a3ComSwitchingSystemsFddiMib 1 } a3ComFddiMAC OBJECT IDENTIFIER ::= { a3ComSwitchingSystemsFddiMib 2 } a3ComFddiPATH OBJECT IDENTIFIER ::= { a3ComSwitchingSystemsFddiMib 3 } a3ComFddiPORT OBJECT IDENTIFIER ::= { a3ComSwitchingSystemsFddiMib 4 } -- the a3ComFddiSMT group -- the a3ComFddiSMTTable a3ComFddiSMTTable OBJECT-TYPE SYNTAX SEQUENCE OF A3ComFddiSMTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of optional SMT entries. The number of entries shall not exceed the value of snmpFddiSMTNumber." ::= { a3ComFddiSMT 1 } a3ComFddiSMTEntry OBJECT-TYPE SYNTAX A3ComFddiSMTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An optional SMT entry containing information common to a given optional SMT." INDEX { a3ComFddiSMTIndex } ::= { a3ComFddiSMTTable 1 } A3ComFddiSMTEntry ::= SEQUENCE { a3ComFddiSMTIndex INTEGER, a3ComFddiSMTManufacturerOUI OCTET STRING, a3ComFddiSMTManufacturerData OCTET STRING, a3ComFddiSMTHoldState INTEGER, a3ComFddiSMTSetCount INTEGER, a3ComFddiSMTLastSetStationId FddiSMTStationIdType } a3ComFddiSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { a3ComFddiSMTEntry 1 } a3ComFddiSMTManufacturerOUI OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) ACCESS read-only STATUS mandatory DESCRIPTION "The three octets of manufacturer data which make up the manufacturerOUI component." REFERENCE "ANSI { fddiSMT 16 }" ::= { a3ComFddiSMTEntry 2 } a3ComFddiSMTManufacturerData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (29)) ACCESS read-only STATUS mandatory DESCRIPTION "The 29 octets of manufacturer data which make up the manufacturerData component." REFERENCE "ANSI { fddiSMT 16 }" ::= { a3ComFddiSMTEntry 3 } a3ComFddiSMTHoldState OBJECT-TYPE SYNTAX INTEGER { not-implemented(1), -- holding not implemented not-holding(2), holding-prm(3), -- holding on primary holding-sec(4) -- holding on secondary } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the current state of the Hold function. The value 'not-holding' is the default and initial value. The value must be set to 'not-holding' as part of Active_Actions and when the conditions causing 'holding-prm' or 'holding-sec' are no longer true. The value 'holding-prm' must be set when the condition (notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is satisfied in state PC8:ACTIVE for the A Port. The value 'holding-sec' must be set when the condition (notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is satisfied in state PC8:ACTIVE for the B Port." REFERENCE "ANSI { fddiSMT 43 }" ::= { a3ComFddiSMTEntry 4 } a3ComFddiSMTSetCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable is composed of a count incremented in response to a Set operation on the MIB, and the time of the change, however only the count is reported here (refer to ANSI SMT 8.4.1)." REFERENCE "ANSI { fddiSMT 53 }" ::= { a3ComFddiSMTEntry 5 } a3ComFddiSMTLastSetStationId OBJECT-TYPE SYNTAX FddiSMTStationIdType ACCESS read-only STATUS mandatory DESCRIPTION "The Station ID of the station that effected the last change in the FDDI MIB." REFERENCE "ANSI { fddiSMT 54 }" ::= { a3ComFddiSMTEntry 6 } -- the a3ComFddiMAC group -- the a3ComFddiMACBridgeFunctionTable a3ComFddiMACBridgeFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF A3ComFddiMACBridgeFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of MAC bridge function entries." ::= { a3ComFddiMAC 1 } a3ComFddiMACBridgeFunctionEntry OBJECT-TYPE SYNTAX A3ComFddiMACBridgeFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Bridge function information for a given MAC within a given SMT." INDEX { a3ComFddiMACBridgeFunctionSMTIndex, a3ComFddiMACBridgeFunctionMACIndex } ::= { a3ComFddiMACBridgeFunctionTable 1 } A3ComFddiMACBridgeFunctionEntry ::= SEQUENCE { a3ComFddiMACBridgeFunctionSMTIndex INTEGER, a3ComFddiMACBridgeFunctionMACIndex INTEGER, a3ComFddiMACBridgeFunctions INTEGER } a3ComFddiMACBridgeFunctionSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { a3ComFddiMACBridgeFunctionEntry 1 } a3ComFddiMACBridgeFunctionMACIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Index variable for uniquely identifying the MAC object instances." REFERENCE "ANSI { fddiMAC 34 }" ::= { a3ComFddiMACBridgeFunctionEntry 2 } a3ComFddiMACBridgeFunctions OBJECT-TYPE SYNTAX INTEGER (-1..7) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the MAC's optional bridging functions. The Value -1 is used to indicate that bridging is not supported by this MAC. The value is a sum. This value initially takes the value zero, then for each function present, 2 raised to a power is added to the sum. The powers are according to the following table: Function Power tb 0 -- Transparent bridging active sr 1 -- Src routing active srt 2 -- Src routing transparent active " REFERENCE "ANSI { fddiMAC 12 }" ::= { a3ComFddiMACBridgeFunctionEntry 3 } -- the a3ComFddiMACTPriTable a3ComFddiMACTPriTable OBJECT-TYPE SYNTAX SEQUENCE OF A3ComFddiMACTPriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of MAC T-Pri entries." ::= { a3ComFddiMAC 2 } a3ComFddiMACTPriEntry OBJECT-TYPE SYNTAX A3ComFddiMACTPriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of T-Pri information for a given MAC within a given SMT." INDEX { a3ComFddiMACTPriSMTIndex, a3ComFddiMACTPriMACIndex } ::= { a3ComFddiMACTPriTable 1 } A3ComFddiMACTPriEntry ::= SEQUENCE { a3ComFddiMACTPriSMTIndex INTEGER, a3ComFddiMACTPriMACIndex INTEGER, a3ComFddiMACTPri0 FddiTimeNano, a3ComFddiMACTPri1 FddiTimeNano, a3ComFddiMACTPri2 FddiTimeNano, a3ComFddiMACTPri3 FddiTimeNano, a3ComFddiMACTPri4 FddiTimeNano, a3ComFddiMACTPri5 FddiTimeNano, a3ComFddiMACTPri6 FddiTimeNano } a3ComFddiMACTPriSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { a3ComFddiMACTPriEntry 1 } a3ComFddiMACTPriMACIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Index variable for uniquely identifying the MAC object instances." REFERENCE "ANSI { fddiMAC 34 }" ::= { a3ComFddiMACTPriEntry 2 } a3ComFddiMACTPri0 OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units." REFERENCE "ANSI { fddiMAC 56 }" ::= { a3ComFddiMACTPriEntry 3 } a3ComFddiMACTPri1 OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units." REFERENCE "ANSI { fddiMAC 57 }" ::= { a3ComFddiMACTPriEntry 4 } a3ComFddiMACTPri2 OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units." REFERENCE "ANSI { fddiMAC 58 }" ::= { a3ComFddiMACTPriEntry 5 } a3ComFddiMACTPri3 OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units." REFERENCE "ANSI { fddiMAC 59 }" ::= { a3ComFddiMACTPriEntry 6 } a3ComFddiMACTPri4 OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units." REFERENCE "ANSI { fddiMAC 60 }" ::= { a3ComFddiMACTPriEntry 7 } a3ComFddiMACTPri5 OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units." REFERENCE "ANSI { fddiMAC 61 }" ::= { a3ComFddiMACTPriEntry 8 } a3ComFddiMACTPri6 OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-only STATUS mandatory DESCRIPTION "This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units." REFERENCE "ANSI { fddiMAC 62 }" ::= { a3ComFddiMACTPriEntry 9 } -- the a3ComFddiPATH group -- the a3ComFddiPATHRingTable a3ComFddiPATHRingTable OBJECT-TYPE SYNTAX SEQUENCE OF A3ComFddiPATHRingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PATH ring entries." ::= { a3ComFddiPATH 1 } a3ComFddiPATHRingEntry OBJECT-TYPE SYNTAX A3ComFddiPATHRingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Ring latency, trace status, and T-Rmode information for a given PATH within a given SMT." INDEX { a3ComFddiPATHRingSMTIndex, a3ComFddiPATHRingPATHIndex } ::= { a3ComFddiPATHRingTable 1 } A3ComFddiPATHRingEntry ::= SEQUENCE { a3ComFddiPATHRingSMTIndex INTEGER, a3ComFddiPATHRingPATHIndex INTEGER, a3ComFddiPATHRingLatency FddiTimeNano, a3ComFddiPATHTraceStatus INTEGER, a3ComFddiPATHT-Rmode FddiTimeNano } a3ComFddiPATHRingSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { a3ComFddiPATHRingEntry 1 } a3ComFddiPATHRingPATHIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index variable for uniquely identifying the primary, secondary and local PATH object instances. Local PATH object instances are represented with integer values 3 to 255." REFERENCE "ANSI { fddiPATH 11 }" ::= { a3ComFddiPATHRingEntry 2 } a3ComFddiPATHRingLatency OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-write STATUS mandatory DESCRIPTION "Gives the total accumulated latency of the ring associated with this path. May be measured directly by the station or calculated by a management station. Values of this object are reported in 1 ns units." REFERENCE "ANSI { fddiPATH 13 }" ::= { a3ComFddiPATHRingEntry 3 } a3ComFddiPATHTraceStatus OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the current trace status of the path. The value is a sum which represents all of the trace status information which applies. This value initially takes the value zero, then for each condition which applies, 2 raised to a power is added to the sum. the powers are according to the following table: TraceStatus Power traceinitiated 0 tracepropragated 1 traceterminated 2 tracetimeout 3" REFERENCE "ANSI { fddiPATH 14 }" ::= { a3ComFddiPATHRingEntry 4 } a3ComFddiPATHT-Rmode OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-write STATUS mandatory DESCRIPTION "Used by RMT to limit the duration of restricted dialogs on a path. This object is reported in 1 ns units." REFERENCE "ANSI { fddiPATH 19 }" ::= { a3ComFddiPATHRingEntry 5 } -- the a3ComFddiPATHSbaTable a3ComFddiPATHSbaTable OBJECT-TYPE SYNTAX SEQUENCE OF A3ComFddiPATHSbaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PATH Sba entries." ::= { a3ComFddiPATH 2 } a3ComFddiPATHSbaEntry OBJECT-TYPE SYNTAX A3ComFddiPATHSbaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sba information for a given PATH within a given SMT." INDEX { a3ComFddiPATHSbaSMTIndex, a3ComFddiPATHSbaPATHIndex } ::= { a3ComFddiPATHSbaTable 1 } A3ComFddiPATHSbaEntry ::= SEQUENCE { a3ComFddiPATHSbaSMTIndex INTEGER, a3ComFddiPATHSbaPATHIndex INTEGER, a3ComFddiPATHSbaPayload INTEGER, a3ComFddiPATHSbaOverhead INTEGER, a3ComFddiPATHSbaAvailable INTEGER } a3ComFddiPATHSbaSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { a3ComFddiPATHSbaEntry 1 } a3ComFddiPATHSbaPATHIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Index variable for uniquely identifying the primary, secondary and local PATH object instances. Local PATH object instances are represented with integer values 3 to 255." REFERENCE "ANSI { fddiPATH 11 }" ::= { a3ComFddiPATHSbaEntry 2 } a3ComFddiPATHSbaPayload OBJECT-TYPE SYNTAX INTEGER (0..1562) ACCESS read-write STATUS mandatory DESCRIPTION "The payload portion of the Synchronous Bandwidth Allocation for thi path. This value represents the maximum number of bytes of data allocated for transmission per 125 microseconds." REFERENCE "ANSI { fddiPATH 15 }" ::= { a3ComFddiPATHSbaEntry 3 } a3ComFddiPATHSbaOverhead OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The overhead portion of the Synchronous Bandwith Allocation for this path. This value repersents the maximum number of bytes overhead (token capture, frame header, etc.) used pre negotiated Target Token Rotation Time (T_neg)." REFERENCE "ANSI { fddiPATH 16 }" ::= { a3ComFddiPATHSbaEntry 4 } a3ComFddiPATHSbaAvailable OBJECT-TYPE SYNTAX INTEGER (0..12500000) ACCESS read-write STATUS mandatory DESCRIPTION "This value is the maximum Synchronous Bandwith available for a path in bytes per second." REFERENCE "ANSI { fddiPATH 20 }" ::= { a3ComFddiPATHSbaEntry 5 } -- the a3ComFddiPORT group -- the a3ComFddiPORTTable a3ComFddiPORTTable OBJECT-TYPE SYNTAX SEQUENCE OF A3ComFddiPORTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of optional PORT entries." ::= { a3ComFddiPORT 1 } a3ComFddiPORTEntry OBJECT-TYPE SYNTAX A3ComFddiPORTEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC loop time and EB error count information for a given PORT within a given SMT." INDEX { a3ComFddiPORTSMTIndex, a3ComFddiPORTIndex } ::= { a3ComFddiPORTTable 1 } A3ComFddiPORTEntry ::= SEQUENCE { a3ComFddiPORTSMTIndex INTEGER, a3ComFddiPORTIndex INTEGER, a3ComFddiPORTMACLoopTime FddiTimeNano, a3ComFddiPORTEBErrorCt Counter } a3ComFddiPORTSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { a3ComFddiPORTEntry 1 } a3ComFddiPORTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Index variable for uniquely identifying the PORT object instances." REFERENCE "ANSI { fddiPORT 29 }" ::= { a3ComFddiPORTEntry 2 } a3ComFddiPORTMACLoopTime OBJECT-TYPE SYNTAX FddiTimeNano ACCESS read-write STATUS mandatory DESCRIPTION "This attribute controls the value used for T_Next(9) (see 9.4.4.2.3). This object is reported in 1 ns units." REFERENCE "ANSI { fddiPORT 21 }" ::= { a3ComFddiPORTEntry 3 } a3ComFddiPORTEBErrorCt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count that should as closely as possible match the times an Elasticity Buffer Error has occurred while in active line state." REFERENCE "ANSI { fddiPORT 41 }" ::= { a3ComFddiPORTEntry 4 } -- the a3ComFddiPORTLSTable a3ComFddiPORTLSTable OBJECT-TYPE SYNTAX SEQUENCE OF A3ComFddiPORTLSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of optional PORT line state entries." ::= { a3ComFddiPORT 2 } a3ComFddiPORTLSEntry OBJECT-TYPE SYNTAX A3ComFddiPORTLSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Maintenance line state and PC line state information for a given PORT within a given SMT." INDEX { a3ComFddiPORTLSSMTIndex, a3ComFddiPORTLSPORTIndex } ::= { a3ComFddiPORTLSTable 1 } A3ComFddiPORTLSEntry ::= SEQUENCE { a3ComFddiPORTLSSMTIndex INTEGER, a3ComFddiPORTLSPORTIndex INTEGER, a3ComFddiPORTMaintLS INTEGER, a3ComFddiPORTPCLS INTEGER } a3ComFddiPORTLSSMTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization." ::= { a3ComFddiPORTLSEntry 1 } a3ComFddiPORTLSPORTIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Index variable for uniquely identifying the PORT object instances." REFERENCE "ANSI { fddiPORT 29 }" ::= { a3ComFddiPORTLSEntry 2 } a3ComFddiPORTMaintLS OBJECT-TYPE SYNTAX INTEGER { quiet(1), idle(2), master(3), halt(4), receive-active(5), receive-unknown(6), receive-noise(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The PORT Maintenance Line State specifies the line state (Maint_LS) to be transmitted when the PCM state machine for the port is in state PC9 Maint." REFERENCE "ANSI { fddiPORT 31 }" ::= { a3ComFddiPORTLSEntry 3 } a3ComFddiPORTPCLS OBJECT-TYPE SYNTAX INTEGER { quiet(1), idle(2), master(3), halt(4), receive-active(5), receive-unknown(6), receive-noise(7) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the line state (PC_LS) received by the port." REFERENCE "ANSI { fddiPORT 34 }" ::= { a3ComFddiPORTLSEntry 4 } -- traps -- SMT events a3ComFddiSMTHoldCondition TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, a3ComFddiSMTHoldState } DESCRIPTION "Generated when fddiSMTHoldState (fddimibSMTHoldState) assumes the state holding-prm or holding-sec. This notification is a Condition in the Status Report Protocol (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiSMT 71 }" ::= 1 a3ComFddiSMTPeerWrapCondition TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibSMTCFState, fddimibSMTPeerWrapFlag } DESCRIPTION "This condition is active when fddiSMTPeerWrapFlag (fddimibSMTPeerWrapFlag) is set. This notification is a Condition in the Status Report Protocol (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiSMT 72 }" ::= 2 -- MAC events a3ComFddiMACDuplicateAddressCondition TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibMACSMTAddress, fddimibMACUpstreamNbr, fddimibMACDaFlag, fddimibMACUnaDaFlag } DESCRIPTION "This condition is active when either fddiMACDA-Flag (fddimibMACDaFlag) or fddiMACUNDA-Flag (fddimibMACUnaDaFlag) is set. This event is handled as a Condition in the Status Report Protocol (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiMAC 140 }" ::= 3 a3ComFddiMACFrameErrorCondition TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibMACFrameErrorFlag, fddimibMACFrameCts, fddimibMACErrorCts, fddimibMACLostCts, fddimibMACFrameErrorRatio } DESCRIPTION "Generated when the fddiMACFrameErrorRatio (fddimibMACFrameErrorRatio) is greater than or equal to fddiMACFrameErrorThreshold (fddimibMACFrameErrorThreshold). This event is handled as a Condition in the Status Report Protocol (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiMAC 141 }" ::= 4 a3ComFddiMACNotCopiedCondition TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibMACNotCopiedCts, fddimibMACCopiedCts, fddimibMACNotCopiedRatio, fddimibMACNotCopiedFlag } DESCRIPTION "Generated when the fddiMACNotCopiedRatio (fddimibMACNotCopiedRatio) is greater than or equal to the fddiMACNotCopiedThreshold (a3ComFddiMACNotCopiedThreshold). This event is handled as a Condition in the Status Report Protocol (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiMAC 142 }" ::= 5 a3ComFddiMACNeighborChangeEvent TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibMACUpstreamNbr, fddimibMACOldUpstreamNbr, fddimibMACDownstreamNbr, fddimibMACOldDownstreamNbr, fddimibMACCurrentPath, fddimibMACSMTAddress } DESCRIPTION "Generated when a change in a MAC's upstream neighbor address or downstream neighbor address is detected. (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiMAC 143 }" ::= 6 a3ComFddiMACPathChangeEvent TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibMACAvailablePaths, fddimibMACCurrentPath, fddimibMACRequestedPaths } DESCRIPTION "This event is generated when the value of the fddiMACCurrentPath (fddimibMACCurrentPath) changes. This event shall be supressed if the value changes from isolated to local or local to isolated (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiMAC 144 }" ::= 7 -- PORT events a3ComFddiPORTLerCondition TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibPORTLerCutoff, fddimibPORTLerAlarm, fddimibPORTLerEstimate, fddimibPORTLemRejectCts, fddimibPORTLemCts, fddimibPORTLerFlag } DESCRIPTION "This condition becomes active when the value of fddiPORTLer-Estimate (fddimibPORTLerEstimate) is less than or equal to fddiPORTLer-Alarm (fddimibPORTLerAlarm). This will be reported with the Status Report Frames (SRF) (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiPORT 80 }" ::= 8 a3ComFddiPORTUndesiredConnAttemptEvent TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibPORTMyType, fddimibPORTConnectState, fddimibPORTNeighborType, fddimibPORTPCWithhold } DESCRIPTION "Generated when an undesired connection attempt has been made (see 5.2.4, 7.2.7, and 8.3)." REFERENCE "ANSI { fddiPORT 81 }" ::= 9 a3ComFddiPORTEBErrorCondition TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, a3ComFddiPORTEBErrorCt } DESCRIPTION "Generated when the Elasticity Buffer Error-Ct (a3ComFddiPORTEBErrorCt) increments. This is handled as a condition in the Status Report Protocol. It is generated when an increment occurs in the station's sampling period (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiPORT 82 }" ::= 10 a3ComFddiPORTPathChangeEvent TRAP-TYPE ENTERPRISE a3ComSwitchingSystemsFddiMib VARIABLES { fddimibSMTStationId, fddimibPORTAvailablePaths, fddimibPORTCurrentPath, fddimibPORTRequestedPaths, fddimibPORTMyType, fddimibPORTNeighborType } DESCRIPTION "This event is generated when the value of the fddiPORTCurrentPath (a3ComFddiPORTCurrentPath) changes. This event shall be surpressed if the value changes from isolated to local or local to isolated (see 7.2.7 and 8.3)." REFERENCE "ANSI { fddiPORT 83 }" ::= 11 END