With the IPHost SNMP tool, you can monitor any SNMP objects of the NCDCHASS-MIB . You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the NCDCHASS-MIB .

OID list for NCDCHASS-MIB

ncdchassType
An authoritative identification of the type of hub-based or standalone ncdchasssis. By convention this value is allocated within the SMI enterprises subtree(1.3.6.1.4.1), and provides an easy and unambiguous means for determining `what kind of box' is be ...
ncdchassPhysicalChanges
The number of physical changes that have occurred in the ncdchasssis since the agent was warm/cold started. This includes additions and removal of modules and entities. Other uses are implementation specific.
ncdchassChasssisSerialNumber
The serial number of the ncdchasssis. If no serial number is available then this object should be the zero length string.
ncdchassModuleTable
This table defines the physical modules within a ncdchasssis. This is done by defining the type physical modules and the physical location where it resides. This table also provides a mapping from between physical modules and their location within the n ...
ncdchassModuleEntry
An entry in this table that describes a physical module that resides at a given physcial location within the ncdchasssis.
ncdchassModuleLocation
An instance of a module is identified by the slot number.
ncdchassModuleType
An authoritative identification of the type of physcial module in this physical location. A value of ncdchassModuleUnknown indicates that the type of physical module is unknown.
ncdchassModuleSwVersion
A textual description of the version/revision level for this module's software. If not realized this value should be set to the zero-length string.
ncdchassModuleHwVersion
A textual description of the version/revision level for this module's firmware. If not realized this value should be set to the zero-length string.
ncdchassModuleSerialNumber
The serial number of the physical module present in this physical location. If the physical location table is implemented as dense and the slot is empty this value will be the zero length string. If no serial number is available for a physical module th ...
ncdchassModuleDescription
A textual description of the physical module plugged that resides in this physical location. If not available this value should be set to a zero length string.
ncdchassModuleLastChangeTime
The value of MIB-II's sysUpTime (in the agent supporting this ncdchasssis MIB) at which a module was last inserted or initialized. If the module has not changed since the last network managment system reinitialized then this object has a zero value.
ncdchassModuleAdminStatus
Provides desired state of the given physical module. Notice that not all values may be supported by the specified physical module. In this case an SNMP error will be returned when the set is attempted. A physical module may be activated by writing a val ...
ncdchassModuleOperStatus
Provides operational status of the module. The following are possible definitions of the values. The exact definition of the values is implementation specific. A value of other(1) implies some undetermined state, possibly as a result of setting ncdchass ...
ncdchassEntityTable
A table that contains information about the 'logical' networking devices (entities) in this ncdchasssis.
ncdchassEntityEntry
Information concerning an entity in the ncdchasssis. Conceptual rows may not be created or deleted with SNMP operations.
ncdchassEntityIndex
A unique index for the entity for which this entry contains information.
ncdchassEntityObjectID
The specific type of entity. The value of this object is analagous to MIB-II's sysObjectId.
ncdchassEntityDescr
A textual description of the entity. The value of this object is analagous to MIB-II's sysDescr.
ncdchassEntityAdminStatus
Provides the administratively desired state of the given entity. An entity is activated by writing a value of enable(2). An entity may be de-activated by writing a value of disable(3). In a disabled state, a entity does exist within the given ncdchasssis ...
ncdchassEntityOperStatus
Provides operational status of the entity. The following are possible definitions of the values. The exact definition of the values is implementation specific. A value of other(1) implies some undetermined state, possibly as a result of setting ncdchass ...
ncdchassEntityTimeStamp
The value of MIB-II's sysUpTime (in the agent supporting this MIB) at which this entity was last (re-)initialized. If the entity has not been initialized then this object has a zero value.
ncdchassEntityViewTable
A table of all MIB views orgainized by entity. Each entity may have a number of MIB views associated with it.
ncdchassEntityViewEntry
Defines a specific MIB view.
ncdchassEntityViewEntityId
The unique entity for which this MIB view is defined. This is an instance of ncdchassEntityIndex within the ncdchassEntityTable.
ncdchassEntityViewIndex
Defines a unique MIB view for this entity.
ncdchassEntityCommunity
The SNMP Community which executes at the address ncdchassEntityIpAddress, and provides access to the detailed management information for this entity. For an entity which is not managed through access to a SNMP Community, the value of this object is the ze ...
ncdchassEntityIpAddress
The address of the SNMP agent which responds to messages for the SNMP Community identified by ncdchassEntityCommunity. When access is via proxy, this variable contains the address of the proxy agent. For an entity which is not managed through access to a ...
ncdchassPowerSupplyTable
A list of power supply entries, one for each power supply in the ncdchasssis.
ncdchassPowerSupplyEntry
Values for a power supply.
ncdchassPowerSupplyIndex
An index value that uniquely identifies a power supply.
ncdchassPowerSupplyDescr
A textual description of the power supply, including the vendor's name and version.
ncdchassPowerSupplyAdminStatus
Desired status of the power supply.
ncdchassPowerSupplyOperStatus
Actual status of the power supply: - unknown(1) - status not known. - empty(2) - no power supply installed in slot - disabled(3) - unable to supply power due to ncdchassPowerSupplyAdminStatus - bad(4) - unable to supply power due to failure - warning(5) - ...
ncdchassPowerSupplyHealthText
A textual description of the power supply's operational status. Agents may use this string to provide detailed information on current failures, including how they were detected, and/or instructions for problem resolution. The contents are agent-specific.
ncdchassPowerSupplyWarnings
The number of times ncdchassPowerSupplyOperStatus has gone to warning(5).
ncdchassPowerSupplyFailures
The number of times ncdchassPowerSupplyOperStatus has gone to bad(4).
ncdchassPowerSupplyLocationType
This defines the instance of a physical location type of the power supply. Location Type together with location index completely defines the location of a power supply.
ncdchassPowerSupplyLocationIndex
Defines a particular instance of a physical location type.
ncdchassEnvironTable
A list of environmental entries, one for each environmental sensor in the ncdchasssis.
ncdchassEnvironEntry
Values for a environmental sensor.
ncdchassEnvironIndex
A unique index for the environment for which this entry contains information.
ncdchassEnvironSensor
The identification of an environmental sensor. Other AutonomousType values may be defined elsewhere, in association with specific protocols.
ncdchassEnvironStatus
Actual status indicated by the sensor. It is an implementation specific matter whether the agent keeps entries with status unknown(1) in the table. If unknown(1), counters are
ncdchassEnvironWarnings
The number of times ncdchassEnvironStatus has gone to warning(3).
ncdchassEnvironFailures
The number of times ncdchassEnvironStatus has gone to bad(2).
ncdchassEnvironLocationType
Defines the actual type of physical location that this environmental sensor occupies.
ncdchassEnvironLocationIndex
This defines the particular instance of a physical location type which this environmental sensor occupies.

You can start network devices monitoring using free 30-day trial version of IPHost Network Monitor right now. Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access. The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.